HomeMy WebLinkAboutZ-8813 Staff AnalysisNOVEMBER 26, 2012
File No.: Z-8813
Owner: Ruth Anne Cooper
Applicant: Terry Choat
Address: 5726 Stonewall Road
Description: Lot 128, Forest Heights Plan Addition
Zoned: R-2
Variance Requested: Variances are requested from the area provisions of -Section 36-
156 to allow reconstruction of a carport/garage structure with reduced side setback and
separation from principal structure.
Justification: The applicant's justification is presented in an attached letter.
Present Use of Property: Single Family Residential
Proposed Use of Property: Single Family Residential
STAFF REPORT
A. Public Works Issues:
No Comment.
B. Building Codes Comments:
The required fire separation distance (building to property line) prescribed by the
building code terminates at five (5) feet. Buildings are allowed to be closer than
five (5) feet if they have properly constructed fire walls which provide the requisite
one (1) hour fire resistance rating. When buildings are five (5) feet or more from
the property line, the requirement no longer applies to the wall itself, only the
projections such as eaves or overhangs.
Openings such as doors and windows are limited when the exterior wall is three (3)
feet from the property line, and are prohibited when the exterior wall is less than
three (3) feet from the line. There is no restriction on openings when the exterior
wall is more than three (3) feet from the property line.
Contact the City of Little Rock Building Codes at 371-4832 for additional details.
NOVEMBER 26, 2012
M NO.: 2 (CON'T.
C. Staff Analysis:
The R-2 zoned property at 5726 Stonewall Road is occupied by a one-story frame
single family residence. There is a one -car wide driveway from Stonewall Road at
the southeast corner of the property. The drive leads to a one-story carport/garage
structure at the northeast corner of the residence. The existing carport/garage
structure is 1.2 to 1.5 feet back from the east side property line and 67 feet back
from the front (south) property line. There is three (3) feet to five (5) feet of
separation between the carport/garage structure and the house.
Because of existing drainage problems associated with the existing carport/garage
structure, the applicant proposes to remove the existing structure and replace it
with a new similar structure. The new accessory carport/garage structure will be
constructed on the existing improved foundation and pulled in slightly to have a
side setback of 1.5 feet to the structure's overhang and approximately 1.84 feet to
the exterior wall of the garage. The carport portion will be unenclosed on its south,
east and west sides. The carport will have a small covered walkway between it
and aside door.
Section 36-156(a)(2)f. of the City's Zoning Ordinance requires a minimum side
setback of three (3) feet for accessory structures in residential zones. Section 36-
156(a)(2)b. requires that accessory structures be separated from principal
structures by at least six (6) feet. Therefore, the applicant is requesting to re -build
the existing carport/garage structure with a reduced side setback and separation
from the house.
Staff is supportive of the requested variance. Staff views the request as
reasonable. The applicant is proposing to re -build an accessory structure which
has existed on the property for a number of years. The existing structure appears
to have had no negative impact on the adjacent properties. The applicant is
proposing to slightly improve the existing side setback encroachment. The
proposed re -constructed accessory building will not be out of character with other
similar structures throughout this neighborhood. Adequate separation will exist
between the proposed accessory structure and the existing house to the east.
Staff believes the requested re -construction of the existing accessory structure will
have no adverse impact on the adjacent properties or the general area.
D. Staff Recommendation:
Staff recommends approval of the requested variances, subject to the following
conditions:
1. Compliance with the Building Codes requirements as noted in paragraph
B. of the staff report.
2. The accessory structure must be constructed to match the existing
residence.
3. Guttering must be provided to prevent water run-off onto the adjacent
property to the east.
NOVEMBER 26, 2012
ITEM NO.: 2 (CON'T.)
BOARD OF ADJUSTMENT: (November 26, 2012)
The applicant was present. There were no objectors present. Staff presented the application
with a recommendation of approval, with conditions.
The item was placed on the Consent Agenda and approved, as recommended by staff with a
vote of 4 ayes, 0 nays and 1 absent.