Loading...
HomeMy WebLinkAboutZ-3836-G Map 12SAWCUT AND MATCH EXISTING 0 C.T.K. SCHOOL FFE.: 496.90 PROPOSED GONC. SIDEWALK - ' ,; = ---�- - } ------ N SAWCUT, REMOVE AND N REPLACE EXISTING A z CONCRETE. SEE UTILITY PROPOSED A m m PLAN OFFICE BUILDING m FFE.: 496.90 EXISTING CONC. m N PAD TO REMAIN PROPOSED 8'x15' CONC. z TRANSFORMER PAD MATCH EXISTING (SEE ELEC. PLANS) MATCH EXISTING CONCRETE PAD o CONCRETE PAD m I . • .. I • s EXISTING WA ER LINE \� PROPOSED CONC. SIDEWALK EXISTING 4" SANITARY SEWER CHRIST THE KING CHURCH FFE.: 497.00 EXISTING 4" SANITARY SEWER MATCH EXISTING SIDEWALK EXISTING SIDEWALK ---- I` BLOCK RETAINING. , 0 WALL ' PROPOSED CONC. PAVEMENT PROPOSED 5.5' HC RAMP i ------------1--� CONC. EXISTING 1/2" GAS LINE I 0 SIDEWALK MATCH EXISTINGSIDEWALK MODULAR BLOCKRETAINING WALLTO MATCH EXISTINGMATCH __�EXISTINGJGT --- T— — ° SIDEWALK rHA SED MP TILE PANEL ASPH LT 0 c m SAWCUT AND MATCH EXISTING ASPHALT -PROPOSED STRIPING HC HC SIGN (TYP.) AISLE (TYP.) PROPOSED HC PARKING z MATCH EXISTING Z� CURB AND GUTTER EXISTING SEGMENTAL BLOCK RETAINING WALL TO REMAIN --------- ----- EXISTING ASPHALT PAVEMENT J CONC. SIDEWALK MATCH EXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER MATCH EXISTING CURB AND GUTTER SAWCUT AND MATCH EXISTING ASPHALT GRAPHIC SCALE IN FEET 20' 20' EXISTING CHAIN LINK TO REMAIN MATCH EXISTING SIDEWALK MATCH EXISTING CURB AND GUTTER PROPOSED HC RAMP W/TACTILE PANEL RELOCATE EXISTING GATE. ADD 8' HANGED GATE EXTENSION SAWCUT AND MATCH EXISTING CONCRETE APRON EXISTING GATE TO I REMAIN. ADD 8' HANGED GATE m EXTENSION r , � I � 1 o I 10825 Financial Center Parkway, Suite 300 Little Rock, Arkansas 72211 Crafton Tull ® engineering I surveying 501.664.3245 t 501.664.6704 f www,craftontull.com CTA PROJECT # 12807600 'OP O� CRAFTON, TULL 8 D ASSOCIATES, INC. No. 102 . O; J $ gFKgNSAS ENOS���,p DRAWINGS, WRITTEN MATERIAL, AND DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN WHOLE OR PART IN ANY FORM WITHOUT PRIOR CONSENT OF ROARK PERKINS PERRY YELVINGTON ARCHITECTS. DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS ONLY. IF NOT SHOWN, VERIFY DIMENSIONS WITH THE ARCHITECT. CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE. Z /I� N W N Z V_ (n O Q W LU No J cr C7 am W 0 Z ¢ U Z 0 Z Jir a o 4 � LXLJ � Z Z >" Z F-• 1— v� 2 LJ■�� > iS1 J N Q n �.O wU J a 0 ® U, W U = E- Q z Q CL Q LL J Ir J Z ® �J Z H W '0 L _ 1..1_ U g'CATE OF ARKWAS REGISTERED PROFESSIONAL ENGINEER * * * No 321 A I REVISIONS I DATE SITE PLAN ENLARGEMENT SHT.2 1387 DATE FJOB NO. C1.2 SHEET OF