HomeMy WebLinkAboutZ-3637-F Map 3NOTES: 1. THE SIZE, HEIGHT AND DIRECTION OF THE ANTENNA SHALL BE ADJUSTED TO MEET SYSTEM REQUIREMENTS. 2. CONTRACTOR SHALL VERIFY HEIGHT OF ANTENNA WITH T -MOBILE PM. 3. ALL ANTENNA AZIMUTH ARE TO BE FROM TRUE NORTH. 4. ALL DISTURBED AREAS WILL BE REPLACED TO ORIGINAL CONDITION. 00 doe 1000 000 240°AZ. (VERIFY IN FIELD) NOTE: MINIMUM SPACING OF 10'-0" BETWEEN EACH ANTENNA AT EACH SECTOR ROOSEVELT NEW 11 '_51. X 18'-O" T -MOBILE LEASE . r1 . NEW T -MOBILE PANEL ANTENNAS MOUNTED TO EXTERIOR GARAGE WALL. SEE 2/5-1 - OeAZ (VERIFY IN FIELD) OVERALL SITE PLAN -..(1200AZ. SCALE: I"=40' -O" 1 (VERIFY IN FIELD) NEW T -MOBILE PANEL ANTENNAS MOUNTED TO EXTERIOR GARAGE WALL. SEE 2/5-1 EXISTING TRANSFORMER TO BE UTILIZED (120D 4 11506) ,,�-NEW UNDERGROUND - TELCO 2-2" CONDUIT (ONE FOR FUTURE) NEW 1-2" POWER RUN 2" CONDUIT TO EXISTING TRANSFORMER (1200 4 11506) EXISTING PARKING GARAGE 5TAIRWELL NEW CONDUIT RUN DOWN EXTERIOR WALL FOR ELECTRIC AND TELCO GENERAL NOTES I. EQUIPMENT PLATFORM AND ANTENNAS ARE DE51ONED TO MEET LOCAL BUILDING CODES, AND AN5VEIA/TIA-222-F STRUCTURAL 5TANDARD5 FOR STEEL ANTENNA SUPPORTING STRUCTURES. THE DE51ON WIND SPEED IS GO MPH. 2. ALL STRUCTURAL STEEL SHALL BE HOT -DIPPED GALVANIZED AFTER FABRICATION. 3. EXISTING VEGETATION WILL BE REMOVED INSIDE LEASED AREA AND ACCESS DRIVE. 4. ALL STRUCTURAL STEEL SHALL BE DE5I6NED, FABRICATED, AND ERECTED IN ACCORDANCE WITH A15C SPECIFICATION (LATEST EDITION). 5. ALL CAST IN PLACE CONCRETE SHALL BE MIXED AND PLACED IN ACCORDANCE WITH AGI 318 AND AGI 301. 6. FACILITY 15 UNMANNED AND NOT FOR HUMAN HABITATION (HANDICAPPED ACCESS NOT REQUIRED). 1. THERE WILL BE NO OUTDOOR LIGHTING WITH THE EXCEPTION OF EMERGENCY CONDITIONS. 8. FACILITY HAS NO PLUMBING. 9. FACILITY WILL BE INDEPENDENTLY POWERED WITH SEPARATE METER. 10. ANTENNA PLATFORM AND ANTENNA INSTALLATION SHALL BE CONDUCTED BY FIELD CREW5 EXPERIENCED IN THE A55EMBLY AND ERECTION OF RADIO ANTENNAS, TRANSMISSION LINES, AND SUPPORT STRUCTURES. 11. CONTRACT COMPANIES AND THEIR EMPLOYEES SHALL OBSERVE AND PRACTICE ALL 0.5.H.A. SAFETY GUIDELINE5 WHILE PERFORMING SERVICE FOR T -MOBILE. 12, WHERE A TOWER DOES NOT HAVE A PERMANENT FALL PROTECTION SYSTEM, THE CONTRACT COMPANY 15 RESPONSIBLE FOR PROVIDING A SUITABLE SYSTEM FOR ITS EMPLOYEES. 13. CONTRACTOR SHALL PERFORM A SAFETY INSPECTION PRIOR TO COMMENGING ALL WORK ACTIVITIES AT A T -MOBILE. LEASED OR OWNED SITE. OWNER SHOULD BE IMMEDIATELY NOTIFIED OF SAFETY HAZARDS) FOUND DURING THE INSPECTION THAT COULD CAUSE BODILY HARM OR ENDANGERMENT TO LIFE OR THAT COULD CAUSE DAMAGE TO PROPERTY. ALL WORK SHALL BE HALTED UNTIL SUCH TIME THE REPORTED SAFETY HAZARD CORRECTED. THE SAFETY HAZARD, IF POSSIBLE, SHOULD BE CORRECTED BY THE CONTRACTOR WHILE ON SITE, AFTER THE CONTRACTOR HAS NOTIFIED OWNER OF THE HAZARD AND HAS RECEIVED APPROVAL FROM OWNER TO PERFORM THE CORRECTION. INITIALS PROPERTY OWNER/REP. U J J a O w O z O U) W 0 z O 1= Q U z 0 U F_ m rk W -T COMMUNICATION DESIGN GROUP, LLC 39 E. SCULLY DRIVE SCHAUMBURG, ILLINOIS 60193 ph. (847) 895-3640 fax. 88471 895-9985 T • •Mobile 12120 COLONEL GLENN ROAD SUITE 1000 LITTLE ROCK, AR 72210 2 10-23-02 FOR CONSTRUCTION 1 10-03-02 TFOR CLIENT REVIEW A R 1006. B SECURITY PARKING GARAGE 4405 E. ROOSEVELT RD. LITTLE ROCK, AR 72206 PULASKI COUNTY SIGMA DATE: 5I N T E O,c AR"SAS* SAS REGISTERED PROFESSIONAL ENGINEER 5� 10966 �,� r l? TR �Q _ 12/31/02 SITE PLAN DATE: 10-03-02 SCALE: AS NOTED DRAWN: MJR W -T # T02397 SHEET C-2