HomeMy WebLinkAboutZ-3599-A Staff AnalysisMarch 10, 1981 0 SUBDIVISIONS Item No. 5-A - SITE PLAN REVIEW NAME: Jerry Lee Carter - Office Building LOCATION: Southeast corner of Napa Valley at Hinson Road APPLICANT: Brooks & Curry Engineering nDnnnenr 1. To construct a one story clinic building of approximately 9,000 square feet of 4 acres +. 2. The structure complies with basic bulk and area requirements which are: _ Required Provided Front Yard 25' 76' Side Yard 25' 961/98' Rear Yard 25' Over 300' Height 45' One story Lot Coverage Max 40% .06% USES PROPOSED , Single user medical clinic. SPECIAL REQUIREMENT 1. A 25' green strip parallel to boundary streets (minimum Zoning Ordinance). 2. A 25' buffer/green strip (minimum Subdivision Ordinance) along east and south property line plus a six foot fence. 3. Detailed landscape plan. STAFF ANALYSIS 1. Effect on Environs, Health, Public and Safety No adverse effects should be experienced from this development due to the arterial street relationship and double front lots to the north. A hill mass physically obstructs any view to the south and residential areas. n March 10, 1981 Item No. 5-A - Continued' 2. Conformance to Ordinance The only design element which is deficient is the landscaped 25' strip along the boundary as indicated on the illustrations. A five foot to 25' variable dimension is not permitted. STAFF RECOMMENDATION Approval as submitted subject to submission of a detailed landscape lighting and sign plan review. SUBDIVISION COMMITTEE RECOMMENDATION The Committee made a motion to approve the site plan1subject the staff's recommendation. The motion was passed by a vote of 4 ayes, 0 noes, 1 absent. PLANNING COMMISSION ACTION The Planning Commission made and passed a motion in agreement with the Subdivision Committee's recommendation of approval as filed with the Subdivision Committee subject to subdivision detailed landscape lighting and sign plan review. The vote: 8 ayes, 0 noes, 3 absent.