HomeMy WebLinkAboutResponse to Staff Comments 050922 5800 Evergreen Drive | Little Rock, AR 72205 | Phone 501.663.8800 | Facsimile 501.588.0123 www.harborenv.com Environmental | Safety | Engineering March 9, 2022 Department of Planning and Development 723 West Markham Little Rock, Arkansas 72201 RE: Z-5298, RESPONSE TO CITY COMMENTS AIRPORT HOTEL AND TRAVEL PLAZA 4600 E ROOSEVELT ROAD APPLICATION FOR CONDITIONAL USE PERMIT Dear Mr. Thrower: This letter is in response to the comments received from the City regarding the above referenced project. Please find the responses as follows: Development Staff Comments 1. Provide current survey of the property. Attached, please find the current survey of the property. 2. Provide copy of the Bill of Assurance for the property. If one does not exist, provide note to that effect. Attached, please find the current survey that provides a note stating the Bill of Assurance does not exist. 3. Show phasing plan on the site plan (e.g. hotel – phase I, travel plaza – phase II?) Attached, please find the site plan that shows the phasing of the development, with Phase I being the hotel and Phase II being the travel plaza. 4. Provide number of rooms for the hotel. Attached, please find the site plan showing the number of rooms for the hotel to be 90. 5. Provide days/hours of operation for the travel plaza. The travel plaza is to be in operation 365 days a year and 24 hours a day. 6. Minimum parking required for the hotel is one (1) per guestroom plus 10 percent for employees. Parking required for the travel plaza is four (4) spaces plus one (1) space per 300 square feet of gross floor area. Spaces at gas pumps can be counted in the parking total. The number of parking spaces for the hotel will be 116 spaces total, 4 of which are to be ADA with 1 ADA van space. The number of spaces for the travel plaza will be 69, 4 of which are to be ADA with 1 ADA van space. Mr. Torrence Thrower Response to Comments City of Little Rock Z-5298 – Airport Hotel and Travel Plaza May 9, 2022 Application for Conditional Use Permit Page 2 7. Note dimensions of buildings and dimensions from buildings to property lines on the site plan. Minimum building setbacks from property line are as follows: a. Front – 50 feet b. Sides – 15 feet c. Rear – 25 feet Attached, please find the site plan showing 50’ building setbacks from all assumed rights-of way. 8. Note height of all buildings on the site plan. Maximum building height in I-2 zoning is 75 feet. Also, note that proposed building heights will conform with federal requirements. Attached, please find the site plan showing the building height to be 54’-4”. 9. All dumpster areas must be screened as per Section 36-523 of the code. Attached, please find the site plan and architectural plans showing the proposed dumpster. We will comply with Section 36-523 of the code. 10. Any signs must comply with Section 36-554 of the code (signs allowed in industrial zones). All signs will comply with Section 36-554 of the code. 11. Provide information on site lighting. Attached, please find the site plan that shows the locations of the proposed site lighting. Also find attached data sheets on the proposed site lighting. Maintain Access Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. We will comply. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. If the grade exceeds 10 percent, approval will be denied and the applicant must submit request to be reviewed by Fire Chief for Approval. We will comply. Mr. Torrence Thrower Response to Comments City of Little Rock Z-5298 – Airport Hotel and Travel Plaza May 9, 2022 Application for Conditional Use Permit Page 3 Loading Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. We will comply. Commercial and Industrial Developments – 2 means of access. - Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 We will comply. Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30 feet or three stories in height shall have at least two means of fire apparatus access for each structure. Two means of fire apparatus access are provided for the hotel. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross building area of more than 62,000 square feet shall be provide with two separate and approved fire apparatus access roads. Exception: Projects having a gross building area of up to 124,000 square feet that have a single approved fire apparatus access road when all building are equipped throughout with approved automatic sprinkler systems. Two means of fire apparatus access are provided for the hotel. D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses. We will comply. 30’ Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1 – D105.4 We will comply. D105.1 Where Required. Where the vertical distance between the grade plane and the highest roof surface exceed 30’, approved aerial fire apparatus access roads shall be provided. For the purposes of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater. We will comply. Mr. Torrence Thrower Response to Comments City of Little Rock Z-5298 – Airport Hotel and Travel Plaza May 9, 2022 Application for Conditional Use Permit Page 4 D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of 26’, exclusive of shoulders, in the immediate vicinity of the building or portion thereof. We will comply. D105.3 Proximity to building. At least one of the required access routes meeting this condition shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official. We will comply. D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire apparatus access road or between the aerial fire apparatus road and the building. Other obstructions shall be permitted to be places with the approval of the fire code official. We will comply. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 – C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N Ingram 501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1. We will comply. Buffer and Landscape Requirements 1. Any new site development must comply with the City’s minimal landscape and buffer ordinance requirements. The development will comply with the City’s minimal landscape and buffer ordinance requirements adjusted to comply with the U.S Department of Transportation Federal Aviation Administration guidelines and advisories per memorandum of August 29, 2008 “Landscaping on Airport Property”. 2. Street buffers will be required at six (6) percent of the average depth of the lot. The minimum dimension shall be one-half (½) the full width requirement but in no case be less than nine (9) feet. We will comply. 3. Screening requirements will need to be met for the vehicular use areas adjacent to street rights-of-way. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet. Mr. Torrence Thrower Response to Comments City of Little Rock Z-5298 – Airport Hotel and Travel Plaza May 9, 2022 Application for Conditional Use Permit Page 5 Screening requirements will be met adjusted to comply with the U.S Department of Transportation Federal Aviation Administration guidelines and advisories per memorandum of August 29, 2008 “Landscaping on Airport Property”. 4. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property, or the right-of-way of any street. This strip shall be at least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting strip. A perimeter planting strip will be provided as required adjusted to comply with the U.S Department of Transportation Federal Aviation Administration guidelines and advisories per memorandum of August 29, 2008 “Landscaping on Airport Property”. 5. Building landscape areas shall be provided at the rate equivalent to planter strip three (3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be planted in the building landscape areas for each forty (40) linear feet of vehicular use area abutting the building. Building landscape areas shall be provided as required adjusted adjusted to comply with the U.S Department of Transportation Federal Aviation Administration guidelines and advisories per memorandum of August 29, 2008 “Landscaping on Airport Property”. 6. Eight percent (8%) of the vehicular use area must be designated for green space; this green space needs to be evenly distributed throughout the parking area(s). For developments with more than one hundred fifty (150) parking spaces the minimum size of an interior landscape area shall be three hundred (300) square feet. Interior islands must be a minimum of seven and one half (7 1/2) feet in width. Trees shall be included in the interior landscape areas at the rate of one (1) tree for e very twelve (12) parking spaces. Green space requirements will be met adjusted adjusted to comply with the U.S Department of Transportation Federal Aviation Administration guidelines and advisories per memorandum of August 29, 2008 “Landscaping on Airport Property”. 7. An automatic irrigation system to water landscaped areas shall be required for developments of one (1) acre or larger. Two automatic irrigation systems to water landscaped areas shall be installed, one for for the hotel and one for the travel plaza. 8. The development of two (2) acres or more requires the landscape plan to be stamped with the seal of a Registered Landscape Architect. The landscape plan will be stamped with the seal of a Registered Landscape Architect. Mr. Torrence Thrower Response to Comments City of Little Rock Z-5298 – Airport Hotel and Travel Plaza May 9, 2022 Application for Conditional Use Permit Page 6 9. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. We will comply. Building Code Comments Project is subject to full commercial plan review and approval prior to issuance of a building permit. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; crichey@littlerock.gov or Steve Crain at 501-371-4875; scrain@littlerock.gov. We will comply. Thank you for your continued review of this Conditional Use Permit application. If further information is needed, please let me know. Andrew Rike, P.E. Enc. Sheet V1 Property Survey Sheet C101 Site Plan Sheet AS-1.01 Site Plan (Hotel) SheetAS-1.02 Site Details Holophane Lighting Data Sheets Memorandum of August 29, 2008 “Landscaping on Airport Property” USDA Review of Little Rock Airport Landscaping Plans THISSITEDate:5-06-22REVISION DESCRIPTION DATENO V1Harbor5800 Evergreen DriveLittle Rock, AR 72205Ph (501) 663-8800Fax (501) 588-0123www.harborenv.comX XX-XX-XXXX Scale:NOTEDProject Number:WDDA-22208Drawn By:JRTChecked By:AHRCLINTON NATIONAL AIRPORT PROPERTY SURVEY HOTEL AND TRAVEL PLAZA SCALE: 1" = 50'50'50'0'25'PROPERTY LINEUTILITY EASEMENTOVERHEAD ELECTRICCHAIN LINK FENCERIGHT OF WAYPOLE MOUNTED LIGHTFIRE HYDRANTELECTRICAL BOXTELEPHONE RISERBUILDING SETBACK LINEHATCH (NO PARKING)HATCH (CONCRETE)SANITARY SEWERSANITARY SEWER MANHOLESANITARY CLEANOUTWATER METERWATER VALVEPOWER POLEPOWER POLE W/ TRANSFORMERGAS METERGAS VALVESTORMWATER SURFACE INLETHANDICAP PARKINGSIGNGAS LINEWATER LINEOVERHEAD WIRE MISCLANDSCAPE LIGHTFIBER OPTIC VAULTWOOD FENCERAILINGDIRECTION OF TRAFFICSTORM DRAINSTORMWATER MANHOLECONTOUR (MAJOR)CONTOUR (MINOR)LEGENDBARBED WIRE FENCELOT LINESOIL PIPELINEPROPERTY LINE ADJACENTUNDERGROUND ELECTRICGUY WIREIRON PIN FOUND(IPF)(IPS)IRON PIN SET - REBARW/CAP (R.L.S. 1203)POWER POLE W/ LIGHT & TRANSR = 600.00'L =186.37'CB = N78°44'26"WCD = 185.62'R = 150.00'L = 128.84'CB = N26°04'41"ECD = 124.92'R = 473.00'L = 172.27'CB = N40°08'58"ECD = 171.32'R = 140.87'L = 133.01'CB = S28°47'09"ECD = 127.07'Point of CommencementNE Corner Lot 2, Carole's AdditionNE1/4 Sec. 18T-1-N, R-11-W, Pulaski Co., ARN 141343.35, E 1244085.35Point of BeginningN 141343.35, E 1244085.35NOT TO SCALE50.0' 45.0'30.0'50.0'30.0'50.0' 1 0 1 1 1 0 1 2 7 7 1 2 PA T IO SMOK ERS F I R E P I T 9 1 7 1 0 1 1FUTURECURB CUT1AS1.02STORMWATERDETEN T IONE. ROOSEVELT ROAD (HALF STREET IMPROVEMENTS AS REQ'D)GAS ISLANDTRAVELPLAZAH Y D X FM R Date:5-06-22REVISION DESCRIPTION DATENO C101Harbor5800 Evergreen DriveLittle Rock, AR 72205Ph (501) 663-8800Fax (501) 588-0123www.harborenv.comX XX-XX-XXXX Scale:NOTEDProject Number:WDDA-22208Drawn By:AHRChecked By:CJMCLINTON NATIONAL AIRPORT SITE PLAN HOTEL AND TRAVEL PLAZA SCALE: 1" = 50'50'50'0'25'PROPERTY LINEUTILITY EASEMENTOVERHEAD ELECTRICCHAIN LINK FENCERIGHT OF WAYPOLE MOUNTED LIGHTFIRE HYDRANTELECTRICAL BOXTELEPHONE RISERBUILDING SETBACK LINEHATCH (NO PARKING)HATCH (CONCRETE)SANITARY SEWERSANITARY SEWER MANHOLESANITARY CLEANOUTWATER METERWATER VALVEPOWER POLEPOWER POLE W/ TRANSFORMERGAS METERGAS VALVESTORMWATER SURFACE INLETHANDICAP PARKINGSIGNGAS LINEWATER LINEOVERHEAD WIRE MISCLANDSCAPE LIGHTFIBER OPTIC VAULTWOOD FENCERAILINGDIRECTION OF TRAFFICSTORM DRAINSTORMWATER MANHOLECONTOUR (MAJOR)CONTOUR (MINOR)LEGENDBARBED WIRE FENCELOT LINESOIL PIPELINEPROPERTY LINE ADJACENTUNDERGROUND ELECTRICGUY WIREIRON PIN FOUND(IPF)(IPS)IRON PIN SET - REBARW/CAP (R.L.S. 1203)POWER POLE W/ LIGHT & TRANSR = 600.00'L =186.37'CB = N78°44'26"WCD = 185.62'R = 150.00'L = 128.84'CB = N26°04'41"ECD = 124.92'R = 473.00'L = 172.27'CB = N40°08'58"ECD = 171.32'R = 140.87'L = 133.01'CB = S28°47'09"ECD = 127.07'Point of CommencementNE Corner Lot 2, Carole's AdditionNE1/4 Sec. 18T-1-N, R-11-W, Pulaski Co., ARN 141343.35, E 1244085.35Point of BeginningN 141343.35, E 1244085.3550.0' 45.0'30.0'50.0'30.0'50.0'LARGE VEHICLE/OVERFLOW PARKING5 4 ' - 4 " B LDG . H T . 9 0 ROOM HO T E L 3 . 8 AC . LO T 1 6 5 , 2 0 1 SQ F T .FIREHYDRANTSITELIGHTING -TYP.SITELIGHTING -TYP. P A T I OS MO K E R S FI R E P I TFUTURECURB CUTSTORMWATERDETENTIONDAVID GRUNDFEST JR. DRIVE (HALF STREET IMPROVEMENTS AS REQ'D)OLD GRUNDFEST DRIVE (TO BE IMPROVED)X F M R THE DRAWINGS, DESIGN, ANDTECHNICAL DATA CONTAINEDHEREIN ARE EXCLUSIVEPROPERTY OF:JIMMY HUDSPETH/ARCHITECT, P.A.UNAUTHORIZED REPRODUCTIONAND/OR REUSE IS PROHIBITEDAND MAY BE PROSECUTED INACCORDANCE WITH THECOPYRIGHT AND PATENT LAWS.Jimmy Hudspeth/ Architect Architecture Crossville, Tennessee550'-0"419'-6" PLAN - EXTERIOR REFUSE RECEPTACLE / STORAGEAS1.02ELEVATION- EXTERIOR REFUSE RECEPTACLE / STORAGEAS1.02SECTION- EXTERIOR REFUSE RECEPTACLE / STORAGEAS1.021AS1.023AS1.022AS1.02SECTION DETAILAS1.02SECTION DETAILAS1.026AS1.02SECTION DETAILAS1.025AS1.024AS1.02THE DRAWINGS, DESIGN, ANDTECHNICAL DATA CONTAINEDHEREIN ARE EXCLUSIVEPROPERTY OF:JIMMY HUDSPETH/ARCHITECT, P.A.UNAUTHORIZED REPRODUCTIONAND/OR REUSE IS PROHIBITEDAND MAY BE PROSECUTED INACCORDANCE WITH THECOPYRIGHT AND PATENT LAWS.Jimmy Hudspeth/ Architect Architecture Crossville, Tennessee 1 0 F I R E P I T 1 7FUTURECURB CUTDAVID GRUNDFEST JR . DR IVE (HALF STREET IMPROVEMENTS AS REQ 'D )OLD GRUNDFEST DRIVE (TO BE IMPROVED)H Y D NEW 90 ROOM HOTEL FOR LITTLE ROCK, ARKANSAS THE DRAWINGS, DESIGN, ANDTECHNICAL DATA CONTAINEDHEREIN ARE EXCLUSIVEPROPERTY OF:JIMMY HUDSPETH/ARCHITECT, P.A.UNAUTHORIZED REPRODUCTIONAND/OR REUSE IS PROHIBITEDAND MAY BE PROSECUTED INACCORDANCE WITH THECOPYRIGHT AND PATENT LAWS.Jimmy Hudspeth/ Architect Architecture Crossville, Tennessee CONWAY HOSPITALITY PH. (731) 479-2115ENGINEERING, INC.DW COLLIERSUITE 100SOUTH FULTON, TN 38257720 BROADWAY STREETDWCEI PROJECT NO. 22-012www.dwcolliereng.comCOLLIERDW COLLIERENGINEERING, INC.No. 1174FC ERTIFIC A ET OAUTNOHORIZATIARKANSASENGI N E ER-ELECTRICAL SITE PLAN6'-0"3'-0"2'-0"ELECTRICAL SITE PLAN SCALE: 1/16" = 1' - 0"1POLE BASE DETAIL SCALE: NONE2 Holophane | 3825 Columbus Rd., Granville, OH 43023 | Phone: 866-HOLOPHANE | www.holophane.com © 2019-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/28/22 Specifications are subject to change without notice. MGLEDM Page 1 of 11 MGLEDM Mongoose Medium LED Catalog Number Notes Type The Mongoose Medium LED offset roadway and area lighting product provides significant energy and maintenance savings vs. HID luminaires. It offers the ultimate in application flexibility with a uniquely designed advanced optical system and attractive appearance. This combined with multiple lighting distributions, mounting options and the ability to tilt the fixture offers unequalled performance in a diverse set of applications ranging from interstates and parking lots. Mechanical • Rugged grade A360 diecast aluminum (<1% copper) • Tool-less access with stainless steel latches • Terminal block in arm • Rigorous 5-stage pretreatment polyester topcoat to ensure maximum durability that achieves a scribe creepage rating of 8 after 5,000 hours of salt spray • Removable “power tray” facilitates maintenance • Corrosion resistant stainless-steel latches ensure secure closure over the long fixture life • Horizontal mast arms or vertical tenon (VH) and universal mounting to round and square poles (UN) options • Universal mount mates to all major manufacturer’s hole patterns • All Mountings are 3G vibration rated per ANSI C136.31 • Adjustable fixture tilt from 0-45 degrees provides flexibility to optimize lighting performance Electrical • Standard surge protection is 20kV/10kA “Extreme Level” per ANSI C136.2 • LED light engines are rated > 100,000 at 25°C, L70 • Electronic driver has an expected life of > 100,000 hours at 25°C • Rated for -40°C / (-40°F) minimum ambient • Programmable electronic driver with 0-10V control leads • Driver voltage options: 120-277V 50/60 Hz and 347 50/60 Hz and 480V 50/60 Hz • Luminaire ships with a 0-10v dimmable driver. Luminaire is continuous and step dimming capable via AO option or controls installed on P7 photocontrol receptacle option. Optical • Performance is comparable to 150-400 watt HPS or 175- 1,000 watt MH • IP66 rated borosilicate glass optics ensure longevity and minimize dirt depreciation • IP66 rated optics • Molded Silicone optics: Area (Type 5) (AR), Forward Throw (FT), Medium Roadway (MR), Narrow Roadway (NR) and Wide Roadway (WR) • Borosilicate glass refractor optics: Area (AG), Forward Throw (FG), Medium Roadway (MG), Narrow Roadway (NG) and Wide Roadway (WG) • 3000K, 4000K and 5000K CCT, 70 CRI • Optional Uplight Skirt (US) when used with refractor ensures zero uplight above 90° • House side shield (HSS), light trespass shield and option available • Wire guard kit option available Controls • 7 pin NEMA photocontrol receptacle • Premium solid-state locking-style photocontrol (PCSS) – 10 year rated life • Extreme long life solid state locking-style photocontrol (PCLL) – 20 year rated life • Field adjustable output • nLight Air motion and daylight sensor • Programmable motion and daylight sensor Certification & Standards • CSA Certified to US and Canadian standards • Suitable for operation in an ambient temperature up to 40°C / 104°F for standard product • Designlights Consortium® (DLC) qualified product. Not all versions of this product may be DLC qualified. Please check the DLC Qualified Products List at www.designlights.org/ QPL to confirm which versions are qualified. BUY AMERICAN This product is assembled in the USA and meets the Buy America(n) government procurement requirements under FAR, DFARS and DOT. Please refer to www.acuitybrands.com/ resources/buyamerican for additional information. Warranty 5-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and- conditions Note: Actual performance may differ as a result of end-user environment and application.All values are design or typical values, measured under laboratory conditions at 25°C DIMENSIONAL DATA Mounting/Optic Tilt Weight EPA VH 0°35 lbs.1.64 sq. ft.VH with Refractor & US 44 lbs. VH 45°35 lbs.2.85 sq. ft.VH with Refractor & US 44 lbs. UN 0°31 lbs.1.64 sq. ft.UN with Refractor & US 38 lbs. (158mm)6.2in (481mm)18.9in (1003mm)39.5in (623mm)24.5in (734mm)28.9in (972mm)38.25in (481mm)18.9in (214mm)8.4in (888mm) 34.97in (857mm) 33.75in (792mm)31.2in (563mm)22.2in (972mm) 38.25in Holophane | 3825 Columbus Rd., Granville, OH 43023 | Phone: 866-HOLOPHANE | www.holophane.com © 2019-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/28/22 Specifications are subject to change without notice. MGLEDM Page 2 of 11 MGLEDM Mongoose Medium LED Series LED performance package Color temperature Voltage Optics MGLEDM Mongoose Medium P1 15,400 Lumens P2 19,000 Lumens P3 22,400 Lumens P4 25,800 Lumens P5 28,900 Lumens P6 31,900 Lumens P7 35,100 Lumens P8 38,000 Lumens 30K 3,000 K CCT 40K 4,000 K CCT 50K 5,000 K CCT MVOLT Auto-sensing voltage (120 thru 277) 347 347 Volt 480 480 Volt AG Area with Refractor AR Area FG Forward Throw with Refractor FT Forward Throw MG Medium Roadway with Refractor MR Medium Roadway NG Narrow Roadway with Refractor NR Narrow Roadway WG Wide Roadway with Refractor WR Wide Roadway Mounting Super Durable Paint Options VH Vertical Tenon/ Horizontal Arm UN Universal (Rd. & Sq) GRSD Vitracoat Gray GHSD Vitracoat Graphite BKSD Vitracoat Black GNSD Vitracoat Green WHSD Vitracoat White BZSD Vitracoat Bronze Adjustable/Programmable Options AO Field Adjustable Output Control Options PCLL DTL Extreme Long Life Twistlock Photocontrol for Solid State (20 year rated life) PCSS DSS Premium Twistlock Photocontrol for Solid State (10 year rated life) POC2 1 Programmable occ. and daylight sensor, for mounting applications up to 20' POC4 1 Programmable occ. and daylight sensor, for mounting applications between 20' & 40' RSDGR nLight Air Occ. and daylight sensor NEMA Label Options NL2 NEMA LABEL NEMA Receptacle Options PR7 7-pin Photocontrol Receptacle Shielding Options US Uplight Skirt HSS House Side Shield Shorting Cap Option SH SHORTING CAP ORDERING INFORMATION Example: MGLEDM P2 40K MVOLT FT UN GRSD Accessories: Order as separate catalog number. Wire Guard Kit MGLEDM WG Mongoose Medium Wire Guard Kit Light Trespass Shield MGLEDM LTS Mongoose Medium Light Trespass Shield Uplight Skirt MGLEDM US GRSD Mongoose Medium Uplight Skirt, Vitracoat Gray MGLEDM US GHSD Mongoose Medium Uplight Skirt, Vitracoat Graphite MGLEDM US BKSD Mongoose Medium Uplight Skirt, Vitracoat Black MGLEDM US GNSD Mongoose Medium Uplight Skirt, Vitracoat Green MGLEDM US WHSD Mongoose Medium Uplight Skirt, Vitracoat White MGLEDM US BZSD Mongoose Medium Uplight Skirt, Vitracoat Bronze House Side Shield MGLEDM HSS Mongoose Medium House Side Shield MOUNTING OPTIONS Vertical Tenon/Horizontal Arm Mount – VH Attaches to 2" vertical tenon or horizontal mast arm (2 3/8" O.D.) Universal Mount – UN Attaches to square or 3" minimum round pole Notes 1 For custom programming of the sensor, a wireless handheld configuration tool, Part No. FSIR-100 should be purchased, either from Legrand, or from Acuity (by special request). 2 NL not available with POC2, POC4 or RSDGR. Holophane | 3825 Columbus Rd., Granville, OH 43023 | Phone: 866-HOLOPHANE | www.holophane.com © 2019-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/28/22 Specifications are subject to change without notice. MGLEDM Page 3 of 11 MGLEDM Mongoose Medium LED LUMEN AMBIENT TEMPERATURE (LAT) MULTIPLIERS Use these factors to determine relative lumen output for average ambient temperatures from 0-40°C (32-104°F). OPTIONS MATRIX Temperature Ambient Temperature (°C) Lumen Multiplier °C °F P1 P2 P3 P4 P5 P6 P7 P8 0 32 1.03 1.03 1.03 1.03 1.04 1.04 1.04 1.05 5 41 1.02 1.02 1.03 1.03 1.03 1.03 1.03 1.04 10 50 1.02 1.02 1.02 1.02 1.02 1.02 1.03 1.03 15 59 1.01 1.01 1.01 1.01 1.02 1.02 1.02 1.02 20 68 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 25 77 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Mounting SELECTED OPTION (start here) AO PR7 PCLL PCSS POC2 POC4 RSDGR SH Controls AO Y Y Y N N N Y PR7 Y Y Y N N N Y PCLL Y Y N N N N N PCSS Y Y N N N N N POC2 N N N N N N N POC4 N N N N N N N RSDGR N N N N N N N SH Y Y N N N N N Voltage MVOLT Y Y Y Y Y Y Y Y 347 Y Y Y N Y Y Y Y 480 Y Y Y N Y Y Y Y Performance Packages P1 Y Y Y Y Y Y Y Y P2 Y Y Y Y Y Y Y Y P3 Y Y Y Y Y Y Y Y P4 Y Y Y Y Y Y Y Y P5 Y Y Y Y Y Y Y Y P6 Y Y Y Y Y Y Y Y P7 Y Y Y Y Y Y Y Y P8 Y Y Y Y Y Y Y Y Y = Valid Option Combination N = Combination Not available Holophane | 3825 Columbus Rd., Granville, OH 43023 | Phone: 866-HOLOPHANE | www.holophane.com © 2019-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/28/22 Specifications are subject to change without notice. MGLEDM Page 4 of 11 MGLEDM Mongoose Medium LED PERFORMANCE DATA Performance Package Distribution Input Watts 30K (3000K CCT, 70 CRI)40K (4000K CCT, 70 CRI)50K (5000K CCT, 70 CRI)LLD @ 25ºC Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G 50k Hours 75k Hours 100k Hours P1 AG 105 15,680 149 4 2 2 16,129 154 4 2 2 16,329 156 4 2 2 0.97 0.97 0.96 AR 16,915 161 4 0 2 17,400 166 4 0 2 17,616 168 4 0 2 FG 14,519 138 2 3 3 14,935 142 2 3 3 15,120 144 3 3 3 FT 15,763 150 2 0 3 16,215 154 2 0 3 16,416 156 2 0 3 MG 15,064 143 2 2 2 15,496 148 2 2 2 15,687 149 3 2 2 MR 16,193 154 2 0 2 16,657 159 3 0 3 16,863 161 3 0 3 NG 15,292 146 3 2 2 15,731 150 3 2 2 15,925 152 3 2 2 NR 16,326 155 3 0 2 16,794 160 3 0 2 17,002 162 3 0 2 WG 14,577 139 3 2 3 14,994 143 3 2 3 15,180 145 3 2 3 WR 15,746 150 3 0 3 16,198 154 3 0 3 16,398 156 3 0 3 P2 AG 126 19,225 153 4 2 2 19,776 157 4 2 2 20,021 159 4 3 2 0.97 0.97 0.96 AR 20,740 165 4 0 2 21,335 169 4 0 2 21,599 171 4 0 2 FG 17,802 141 3 3 3 18,313 145 3 3 4 18,539 147 3 3 4 FT 19,328 153 3 0 4 19,882 158 3 0 4 20,128 160 3 0 4 MG 18,470 147 3 2 3 19,000 151 3 2 3 19,235 153 3 2 3 MR 19,854 158 3 0 3 20,423 162 3 0 3 20,676 164 3 0 3 NG 18,750 149 3 2 2 19,288 153 3 2 2 19,527 155 3 2 3 NR 20,018 159 3 0 2 20,592 163 3 0 2 20,847 165 3 0 2 WG 17,873 142 3 3 3 18,385 146 3 3 3 18,613 148 3 3 3 WR 19,307 153 3 0 3 19,860 158 3 0 3 20,106 160 3 0 3 P3 AG 155 22,726 147 4 3 2 23,377 151 4 3 2 23,667 153 4 3 2 0.97 0.96 0.96 AR 24,517 158 4 0 2 25,219 163 5 0 3 25,532 165 5 0 3 FG 21,044 136 3 3 4 21,647 140 3 3 4 21,915 141 3 3 4 FT 22,847 147 3 0 4 23,502 152 3 0 4 23,793 154 3 0 4 MG 21,833 141 3 3 3 22,459 145 3 3 3 22,737 147 3 3 3 MR 23,469 151 3 0 3 24,142 156 3 0 3 24,441 158 3 0 3 NG 22,164 143 3 2 3 22,799 147 3 2 3 23,082 149 3 2 3 NR 23,663 153 3 0 3 24,341 157 3 0 3 24,643 159 3 0 3 WG 21,127 136 3 3 3 21,732 140 3 3 3 22,001 142 3 3 3 WR 22,822 147 3 0 3 23,476 151 3 0 3 23,767 153 3 0 3 P4 AG 180 26,107 145 4 3 2 26,855 149 4 3 2 27,188 151 4 3 2 0.97 0.96 0.95 AR 28,164 156 5 0 3 28,972 161 5 0 3 29,330 163 5 0 3 FG 24,175 134 3 3 4 24,868 138 3 3 4 25,176 140 3 3 4 FT 26,246 146 3 0 5 26,998 150 3 0 5 27,333 152 3 0 5 MG 25,082 139 3 3 3 25,800 143 3 3 3 26,120 145 3 3 3 MR 26,961 150 3 0 3 27,734 154 3 0 3 28,077 156 3 0 3 NG 25,462 141 3 3 3 26,192 146 3 3 3 26,516 147 3 3 3 NR 27,184 151 3 0 3 27,963 155 3 0 3 28,309 157 3 0 3 WG 24,270 135 3 3 3 24,966 139 3 3 3 25,275 140 3 3 3 WR 26,218 146 3 0 3 26,969 150 3 0 3 27,303 152 3 0 3 Holophane | 3825 Columbus Rd., Granville, OH 43023 | Phone: 866-HOLOPHANE | www.holophane.com © 2019-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/28/22 Specifications are subject to change without notice. MGLEDM Page 5 of 11 MGLEDM Mongoose Medium LED PERFORMANCE DATA (continued) Performance Package Distribution Input Watts 30K (3000K CCT, 70 CRI)40K (4000K CCT, 70 CRI)50K (5000K CCT, 70 CRI)LLD @ 25ºC Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G 50k Hours 75k Hours 100k Hours P5 AG 206 29,340 142 4 3 2 30,181 147 5 3 3 30,555 148 5 3 3 0.96 0.96 0.95 AR 31,653 154 5 0 3 32,560 158 5 0 3 32,963 160 5 0 3 FG 27,169 132 3 3 5 27,947 136 3 3 5 28,294 137 3 3 5 FT 29,497 143 3 0 5 30,342 147 3 0 5 30,718 149 3 0 5 MG 28,188 137 3 3 3 28,996 141 3 3 3 29,355 143 3 3 3 MR 30,300 147 3 0 3 31,169 151 3 0 3 31,555 153 3 0 3 NG 28,615 139 4 3 3 29,436 143 4 3 3 29,800 145 4 3 3 NR 30,550 148 4 0 3 31,426 153 4 0 3 31,815 154 4 0 3 WG 27,276 132 3 3 3 28,058 136 3 3 3 28,405 138 3 3 3 WR 29,465 143 3 0 3 30,309 147 3 0 3 30,685 149 3 0 3 P6 AG 230 32,375 141 5 3 3 33,303 145 5 3 3 33,715 147 5 3 3 0.96 0.95 0.94 AR 34,926 152 5 0 3 35,927 156 5 0 3 36,372 158 5 0 3 FG 29,978 130 3 3 5 30,838 134 3 3 5 31,220 136 3 3 5 FT 32,547 142 3 0 5 33,480 146 3 0 5 33,894 147 3 0 5 MG 31,103 135 3 3 3 31,995 139 3 3 3 32,391 141 3 3 3 MR 33,434 145 3 0 4 34,392 150 3 0 4 34,818 151 3 0 4 NG 31,575 137 4 3 3 32,480 141 4 3 3 32,882 143 4 3 3 NR 33,710 147 4 0 3 34,676 151 4 0 3 35,105 153 4 0 3 WG 30,097 131 4 3 4 30,960 135 4 3 4 31,343 136 4 3 4 WR 32,512 141 3 0 4 33,444 145 3 0 4 33,858 147 4 0 4 P7 AG 255 35,515 139 5 3 3 36,533 143 5 3 3 36,986 145 5 3 3 0.96 0.95 0.93 AR 38,314 150 5 0 4 39,412 155 5 0 4 39,900 156 5 0 4 FG 32,886 129 3 3 5 33,829 133 4 3 5 34,248 134 4 3 5 FT 35,704 140 3 0 5 36,728 144 4 0 5 37,183 146 4 0 5 MG 34,120 134 3 3 3 35,098 138 3 3 3 35,533 139 4 3 3 MR 36,677 144 3 0 4 37,728 148 3 0 4 38,195 150 3 0 4 NG 34,638 136 4 3 3 35,630 140 4 3 3 36,072 141 4 3 3 NR 36,980 145 4 0 3 38,040 149 4 0 3 38,511 151 4 0 3 WG 33,017 129 4 3 4 33,963 133 4 3 4 34,383 135 4 3 4 WR 35,666 140 4 0 4 36,688 144 4 0 4 37,142 146 4 0 4 P8 AG 280 38,510 138 5 3 3 39,614 141 5 3 3 40,104 143 5 3 3 0.95 0.93 0.92 AR 41,545 148 5 0 4 42,735 153 5 0 4 43,265 155 5 0 4 FG 35,659 127 4 3 5 36,681 131 4 3 5 37,136 133 4 3 5 FT 38,715 138 4 0 5 39,824 142 4 0 5 40,318 144 4 0 5 MG 36,997 132 4 3 3 38,058 136 4 3 3 38,529 138 4 3 3 MR 39,770 142 4 0 4 40,909 146 4 0 4 41,416 148 4 0 4 NG 37,558 134 4 3 3 38,635 138 4 3 3 39,113 140 4 3 3 NR 40,098 143 4 0 3 41,247 147 4 0 3 41,758 149 4 0 3 WG 35,800 128 4 3 4 36,827 132 4 3 4 37,283 133 4 3 4 WR 38,673 138 4 0 4 39,782 142 4 0 4 40,274 144 4 0 4 Holophane | 3825 Columbus Rd., Granville, OH 43023 | Phone: 866-HOLOPHANE | www.holophane.com © 2019-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/28/22 Specifications are subject to change without notice. MGLEDM Page 6 of 11 MGLEDM Mongoose Medium LED PERFORMANCE DATA — SKIRT OPTION Performance Package Distribution Input Watts 30K (3000K CCT, 70 CRI)40K (4000K CCT, 70 CRI)50K (5000K CCT, 70 CRI)LLD @ 25ºC Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G 50k Hours 75k Hours 100k Hours P1 AG 105 14,813 141 3 0 2 15,237 145 3 0 2 15,426 147 3 0 2 0.97 0.97 0.96 AR 16,041 153 4 0 2 16,500 157 4 0 2 16,705 159 4 0 2 FG 13,647 130 3 0 2 14,038 134 3 0 2 14,212 135 3 0 2 FT 14,662 140 2 0 2 15,082 144 2 0 2 15,269 145 2 0 2 MG 14,623 139 2 0 2 15,042 143 3 0 2 15,228 145 3 0 2 MR 15,485 147 2 0 2 15,928 152 2 0 2 16,126 154 2 0 2 NG 14,965 143 3 0 2 15,394 147 3 0 2 15,585 148 3 0 2 NR 15,868 151 3 0 2 16,323 155 3 0 2 16,525 157 3 0 2 WG 13,943 133 3 0 2 14,343 137 3 0 2 14,521 138 3 0 2 WR 14,571 139 3 0 2 14,989 143 3 0 2 15,174 145 3 0 2 P2 AG 126 18,162 144 4 0 2 18,683 148 4 0 2 18,914 150 4 0 2 0.97 0.97 0.96 AR 19,668 156 4 0 2 20,232 161 4 0 2 20,482 163 4 0 2 FG 16,733 133 3 0 2 17,212 137 3 0 2 17,426 138 3 0 2 FT 17,978 143 3 0 3 18,493 147 3 0 3 18,722 149 3 0 3 MG 17,929 142 3 0 2 18,443 146 3 0 2 18,672 148 3 0 2 MR 18,986 151 3 0 2 19,530 155 3 0 3 19,772 157 3 0 3 NG 18,349 146 3 0 2 18,875 150 3 0 2 19,109 152 3 0 2 NR 19,456 154 3 0 2 20,014 159 3 0 2 20,262 161 3 0 2 WG 17,097 136 3 0 3 17,587 140 3 0 3 17,804 141 3 0 3 WR 17,866 142 3 0 2 18,378 146 3 0 3 18,606 148 3 0 3 P3 AG 155 21,469 139 4 0 2 22,084 142 4 0 2 22,358 144 4 0 2 0.97 0.96 0.96 AR 23,249 150 4 0 2 23,915 154 4 0 2 24,211 156 4 0 2 FG 19,779 128 3 0 2 20,346 131 3 0 3 20,598 133 3 0 3 FT 21,251 137 3 0 3 21,860 141 3 0 3 22,131 143 3 0 3 MG 21,194 137 3 0 3 21,801 141 3 0 3 22,071 142 3 0 3 MR 22,443 145 3 0 3 23,086 149 3 0 3 23,372 151 3 0 3 NG 21,690 140 3 0 2 22,312 144 3 0 2 22,588 146 3 0 2 NR 22,999 148 3 0 2 23,658 153 3 0 2 23,951 155 3 0 2 WG 20,209 130 3 0 3 20,788 134 3 0 3 21,046 136 3 0 3 WR 21,119 136 3 0 3 21,724 140 3 0 3 21,993 142 3 0 3 P4 AG 180 24,663 137 4 0 2 25,370 141 4 0 2 25,685 143 4 0 2 0.97 0.96 0.95 AR 26,708 148 4 0 2 27,474 153 4 0 2 27,814 155 4 0 2 FG 22,722 126 3 0 3 23,374 130 3 0 3 23,663 131 3 0 3 FT 24,413 136 3 0 3 25,113 140 3 0 3 25,424 141 3 0 3 MG 24,347 135 3 0 3 25,045 139 3 0 3 25,355 141 3 0 3 MR 25,782 143 3 0 3 26,521 147 3 0 3 26,850 149 3 0 3 NG 24,917 138 3 0 2 25,631 142 3 0 2 25,949 144 4 0 2 NR 26,421 147 3 0 2 27,178 151 3 0 2 27,515 153 3 0 2 WG 23,216 129 3 0 3 23,882 133 3 0 3 24,177 134 3 0 3 WR 24,261 135 3 0 3 24,957 139 3 0 3 25,266 140 3 0 3 Holophane | 3825 Columbus Rd., Granville, OH 43023 | Phone: 866-HOLOPHANE | www.holophane.com © 2019-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/28/22 Specifications are subject to change without notice. MGLEDM Page 7 of 11 MGLEDM Mongoose Medium LED PERFORMANCE DATA — UPLIGHT SKIRT OPTION (continued) Performance Package Distribution Input Watts 30K (3000K CCT, 70 CRI)40K (4000K CCT, 70 CRI)50K (5000K CCT, 70 CRI)LLD @ 25ºC Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G 50k Hours 75k Hours 100k Hours P5 AG 206 27,718 135 4 0 2 28,513 138 4 0 2 28,866 140 4 0 2 0.96 0.96 0.95 AR 30,016 146 5 0 3 30,876 150 5 0 3 31,259 152 5 0 3 FG 25,536 124 3 0 3 26,268 128 3 0 3 26,594 129 3 0 3 FT 27,437 133 3 0 4 28,223 137 3 0 4 28,572 139 3 0 4 MG 27,362 133 3 0 3 28,147 137 3 0 3 28,495 138 3 0 3 MR 28,975 141 3 0 3 29,806 145 3 0 3 30,175 146 3 0 3 NG 28,003 136 4 0 2 28,806 140 4 0 2 29,163 142 4 0 2 NR 29,693 144 4 0 2 30,544 148 4 0 2 30,922 150 4 0 2 WG 26,091 127 3 0 3 26,839 130 3 0 3 27,172 132 3 0 3 WR 27,266 132 3 0 3 28,048 136 3 0 3 28,395 138 3 0 3 P6 AG 230 30,585 133 5 0 2 31,461 137 5 0 2 31,851 138 5 0 2 0.96 0.95 0.94 AR 33,120 144 5 0 3 34,069 148 5 0 3 34,491 150 5 0 3 FG 28,177 123 3 0 3 28,985 126 3 0 3 29,344 128 3 0 3 FT 30,274 132 3 0 4 31,142 135 3 0 4 31,527 137 3 0 4 MG 30,192 131 3 0 3 31,058 135 3 0 3 31,442 137 3 0 3 MR 31,972 139 3 0 3 32,888 143 3 0 3 33,296 145 3 0 3 NG 30,899 134 4 0 2 31,785 138 4 0 2 32,178 140 4 0 2 NR 32,764 142 4 0 2 33,703 147 4 0 3 34,120 148 4 0 3 WG 28,790 125 4 0 3 29,615 129 4 0 3 29,982 130 4 0 3 WR 30,086 131 3 0 3 30,948 135 3 0 3 31,331 136 4 0 3 P7 AG 255 33,551 132 5 0 3 34,513 135 5 0 3 34,941 137 5 0 3 0.96 0.95 0.93 AR 36,333 142 5 0 3 37,374 147 5 0 3 37,837 148 5 0 3 FG 30,911 121 4 0 4 31,797 125 4 0 4 32,190 126 4 0 4 FT 33,211 130 4 0 4 34,163 134 4 0 4 34,586 136 4 0 4 MG 33,121 130 4 0 3 34,070 134 4 0 3 34,492 135 4 0 3 MR 35,073 138 3 0 3 36,079 141 4 0 3 36,526 143 4 0 3 NG 33,897 133 4 0 2 34,868 137 4 0 3 35,300 138 4 0 3 NR 35,942 141 4 0 3 36,972 145 4 0 3 37,430 147 4 0 3 WG 31,582 124 4 0 3 32,488 127 4 0 3 32,890 129 4 0 3 WR 33,004 129 4 0 3 33,950 133 4 0 3 34,371 135 4 0 3 P8 AG 280 36,380 130 5 0 3 37,423 134 5 0 3 37,887 135 5 0 3 0.95 0.93 0.92 AR 39,396 141 5 0 3 40,526 145 5 0 3 41,027 147 5 0 3 FG 33,517 120 4 0 4 34,478 123 4 0 4 34,905 125 4 0 4 FT 36,011 129 4 0 4 37,043 132 4 0 4 37,502 134 4 0 4 MG 35,914 128 4 0 3 36,943 132 4 0 3 37,401 134 4 0 3 MR 38,031 136 4 0 4 39,121 140 4 0 4 39,605 141 4 0 4 NG 36,755 131 4 0 3 37,808 135 4 0 3 38,276 137 4 0 3 NR 38,972 139 4 0 3 40,089 143 4 0 3 40,586 145 4 0 3 WG 34,245 122 4 0 3 35,227 126 4 0 3 35,663 127 4 0 3 WR 35,787 128 4 0 4 36,813 131 4 0 4 37,269 133 4 0 4 Holophane | 3825 Columbus Rd., Granville, OH 43023 | Phone: 866-HOLOPHANE | www.holophane.com © 2019-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/28/22 Specifications are subject to change without notice. MGLEDM Page 8 of 11 MGLEDM Mongoose Medium LED PERFORMANCE DATA — HOUSE SIDE SHIELD OPTION Performance Package Distribution Input Watts 30K (3000K CCT, 70 CRI)40K (4000K CCT, 70 CRI)50K (5000K CCT, 70 CRI)LLD @ 25ºC Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G 50k Hours 75k Hours 100k Hours P1 AG 105 6,999 67 1 2 2 7,199 69 1 2 2 7,288 69 1 2 2 0.97 0.97 0.96 AR 9,980 95 1 2 2 10,266 98 1 2 2 10,393 99 1 2 2 FG 9,965 95 1 2 3 10,251 98 1 2 3 10,378 99 1 2 3 FT 11,584 110 1 2 3 11,916 113 1 2 3 12,064 115 1 2 3 MG 11,335 108 1 2 2 11,660 111 1 2 2 11,804 112 1 2 2 MR 12,900 123 1 2 2 13,270 126 1 2 2 13,435 128 1 2 2 NG 13,205 126 1 2 2 13,584 129 1 2 2 13,752 131 1 2 2 NR 13,221 126 1 2 2 13,599 130 1 2 2 13,768 131 1 2 2 WG 10,624 101 1 2 2 10,928 104 1 2 2 11,064 105 1 2 2 WR 12,269 117 2 2 3 12,621 120 2 2 3 12,777 122 2 2 3 P2 AG 126 8,581 68 1 2 2 8,827 70 1 2 2 8,937 71 1 2 2 0.97 0.97 0.96 AR 12,237 97 1 2 2 12,588 100 1 2 2 12,743 101 1 2 2 FG 12,219 97 1 3 3 12,569 100 1 3 3 12,725 101 1 3 3 FT 14,204 113 1 2 3 14,611 116 1 3 3 14,792 117 1 3 3 MG 13,898 110 1 2 2 14,297 113 1 2 2 14,474 115 1 2 2 MR 15,818 126 2 2 2 16,271 129 2 2 2 16,473 131 2 2 2 NG 16,191 129 1 2 3 16,655 132 1 2 3 16,861 134 1 2 3 NR 16,210 129 1 2 3 16,675 132 1 2 3 16,881 134 1 2 3 WG 13,026 103 1 2 3 13,400 106 2 2 3 13,566 108 2 2 3 WR 15,043 119 2 2 3 15,475 123 2 2 3 15,666 124 2 2 3 P3 AG 155 10,144 65 1 2 2 10,434 67 1 2 2 10,564 68 1 2 2 0.97 0.96 0.96 AR 14,465 93 1 2 3 14,879 96 1 2 3 15,064 97 1 2 3 FG 14,443 93 1 3 3 14,857 96 1 3 3 15,041 97 1 3 3 FT 16,790 108 1 3 3 17,271 111 1 3 3 17,485 113 1 3 3 MG 16,429 106 2 2 2 16,900 109 2 2 3 17,109 110 2 2 3 MR 18,698 121 2 2 3 19,233 124 2 2 3 19,472 126 2 2 3 NG 19,139 123 2 2 3 19,688 127 2 3 3 19,931 129 2 3 3 NR 19,161 124 1 2 3 19,711 127 1 2 3 19,955 129 1 2 3 WG 15,398 99 2 2 3 15,839 102 2 3 3 16,035 103 2 3 3 WR 17,782 115 2 2 3 18,292 118 2 2 3 18,518 119 2 2 3 P4 AG 180 11,653 65 1 2 2 11,987 67 1 2 2 12,135 67 1 2 2 0.97 0.96 0.95 AR 16,617 92 1 2 3 17,093 95 1 2 3 17,305 96 1 2 3 FG 16,592 92 1 3 3 17,068 95 1 3 3 17,279 96 1 3 3 FT 19,288 107 1 3 4 19,841 110 1 3 4 20,086 112 1 3 4 MG 18,873 105 2 3 3 19,414 108 2 3 3 19,655 109 2 3 3 MR 21,480 119 2 2 3 22,095 123 2 2 3 22,369 124 2 2 3 NG 21,987 122 2 3 3 22,617 126 2 3 3 22,897 127 2 3 3 NR 22,012 122 2 2 3 22,643 126 2 2 3 22,924 127 2 2 3 WG 17,689 98 2 3 3 18,196 101 2 3 3 18,421 102 2 3 3 WR 20,428 113 2 2 3 21,014 117 2 2 3 21,274 118 2 2 3 MEMORANDUM TO: Charles Jones, Operations Director Little Rock National Airport FROM: Tony Bozynski, Director of Planning and Development Dana Carney, Zoning and Subdivision Manager SUBJECT: Landscaping on Airport Property DATE: August 29, 2008 This letter is to confirm the implementation of a policy concerning the application of the City’s Landscape Ordinance to Little Rock National Airport properties. Landscaping requirements for projects on Airport property will be adjusted to comply with U.S. Department of Transportation Federal Aviation Administration guidelines and advisories. To secure the public health, welfare and safety, plant varieties which are attractive to hazardous wildlife will not be required to be planted on Airport property. Specifically, trees, which provide roosting and nesting ground for birds, will not be required on airport property. USDA March 27, 2009 United States Department of Agriculture Animal and Plant Health Inspection Service Wildlife Services 2967 HWY 130 E Almyra, AR 72003 870-673-1 121 870-672-7391 FAX Mr. Charles Jones Operations Director Adams Field-Little Rock Airport Number 1 Airport Drive Little Rock, AR 72202 Dear Mr. Jones: I have reviewed the landscaping plans for Supermarine of Little Rock, LLC. as requested. Ornamental vegetation around Supermarine of Little Rock, LLC. hangers may improve the appearance of the airport, but can attract birds and mammals. On all three hangers ornamental trees, such as Brodie Juniper and Holmstrup Eastern Arborvitae, should be avoided. These types of trees could serve as an attractant to birds for nesting and roosting cover. Ornamental trees should be low growing, sparsely branched and non-fruiting and should be limited to areas immediately adjacent to buildings and planted no less than 10 m (30ft) apart (Sliwinski 1995). Ornamental shrubs, such as crepe myrtle, should also be avoided due to thick vegetation growth they provide. Shrubs should be planted far enough apart or thinned so thick growth does not occur. Hedge rows should be narrow and maintained at a low height to reduce wildlife usage. Furthermore, ornamental trees and shrubs may require pruning or removal, if planted, to eliminate wildlife use. Hopefully, this information on vegetation planting is beneficial to you in your efforts to maintain safety at Little Rock National Airport. As conditions change within the airport grounds, USDAlAPHlSNVildlife Services will be happy to assist you with further evaluations. If you have questions, please call me. Sincerely, fid///& Micheal . Kearby, USDA~APH~SNV~I~I~~~ Services Biological Science Technician .cc: Bruce Kirkendoll, FAA, Forth Worth AMIS Safeguarding American Agriculture APHIS is an agency of USDA's Marketing and Regulatory Programs An Equal Opportunity Provider and Employer Holophane | 3825 Columbus Rd., Granville, OH 43023 | Phone: 866-HOLOPHANE | www.holophane.com © 2019-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/28/22 Specifications are subject to change without notice. MGLEDM Page 9 of 11 MGLEDM Mongoose Medium LED PERFORMANCE DATA — HOUSE SIDE SHIELD OPTION (continued) Performance Package Distribution Input Watts 30K (3000K CCT, 70 CRI)40K (4000K CCT, 70 CRI)50K (5000K CCT, 70 CRI)LLD @ 25ºC Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G 50k Hours 75k Hours 100k Hours P5 AG 206 13,096 64 1 2 2 13,472 65 1 2 2 13,638 66 1 2 2 0.96 0.96 0.95 AR 18,675 91 1 3 3 19,210 93 1 3 3 19,448 94 1 3 3 FG 18,647 91 1 3 4 19,182 93 1 3 4 19,419 94 1 3 4 FT 21,677 105 1 3 4 22,298 108 1 3 4 22,574 110 1 3 4 MG 21,211 103 2 3 3 21,819 106 2 3 3 22,089 107 2 3 3 MR 24,140 117 2 2 3 24,832 121 2 2 3 25,139 122 2 2 3 NG 24,710 120 2 3 3 25,418 123 2 3 3 25,733 125 2 3 3 NR 24,739 120 2 3 3 25,448 124 2 3 3 25,763 125 2 3 3 WG 19,880 97 2 3 3 20,450 99 2 3 3 20,703 101 2 3 3 WR 22,958 111 2 2 3 23,616 115 2 2 3 23,909 116 3 2 3 P6 AG 230 14,451 63 1 3 3 14,865 65 1 3 3 15,049 65 1 3 3 0.96 0.95 0.94 AR 20,606 90 1 3 3 21,197 92 1 3 3 21,459 93 1 3 4 FG 20,576 89 1 3 4 21,165 92 1 3 4 21,428 93 1 3 4 FT 23,918 104 1 3 4 24,604 107 1 3 4 24,909 108 1 3 4 MG 23,404 102 2 3 3 24,075 105 2 3 3 24,373 106 2 3 3 MR 26,636 116 2 2 3 27,400 119 2 2 3 27,739 121 2 2 4 NG 27,265 119 2 3 3 28,047 122 2 3 3 28,394 123 2 3 3 NR 27,297 119 2 3 3 28,079 122 2 3 3 28,427 124 2 3 3 WG 21,936 95 2 3 3 22,564 98 2 3 3 22,844 99 2 3 3 WR 25,332 110 3 2 3 26,058 113 3 2 3 26,381 115 3 2 4 P7 AG 255 15,852 62 1 3 3 16,307 64 1 3 3 16,509 65 1 3 3 0.96 0.95 0.93 AR 22,605 89 1 3 4 23,253 91 1 3 4 23,541 92 1 3 4 FG 22,572 89 2 3 4 23,219 91 2 3 4 23,506 92 2 3 4 FT 26,239 103 1 3 4 26,991 106 1 3 4 27,325 107 2 3 4 MG 25,675 101 2 3 3 26,411 104 2 3 3 26,738 105 2 3 3 MR 29,220 115 2 3 4 30,058 118 3 3 4 30,430 119 3 3 4 NG 29,910 117 2 3 3 30,767 121 2 3 3 31,148 122 2 3 3 NR 29,945 117 2 3 3 30,803 121 2 3 3 31,185 122 2 3 3 WG 24,063 94 2 3 3 24,753 97 2 3 3 25,060 98 2 3 3 WR 27,790 109 3 3 4 28,586 112 3 3 4 28,940 113 3 3 4 P8 AG 280 17,189 61 1 3 3 17,682 63 1 3 3 17,901 64 1 3 3 0.95 0.93 0.92 AR 24,511 88 1 3 4 25,214 90 1 3 4 25,526 91 1 3 4 FG 24,475 87 2 3 4 25,176 90 2 3 4 25,488 91 2 3 4 FT 28,451 102 2 3 4 29,266 105 2 3 4 29,629 106 2 3 4 MG 27,840 99 2 3 3 28,638 102 2 3 3 28,992 104 2 3 3 MR 31,684 113 3 3 4 32,592 116 3 3 4 32,996 118 3 3 4 NG 32,432 116 2 3 3 33,362 119 2 3 4 33,775 121 2 3 4 NR 32,470 116 2 3 3 33,401 119 2 3 3 33,814 121 2 3 3 WG 26,092 93 2 3 3 26,840 96 3 3 4 27,173 97 3 3 4 WR 30,133 108 3 3 4 30,996 111 3 3 4 31,380 112 3 3 4 Holophane | 3825 Columbus Rd., Granville, OH 43023 | Phone: 866-HOLOPHANE | www.holophane.com © 2019-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/28/22 Specifications are subject to change without notice. MGLEDM Page 10 of 11 MGLEDM Mongoose Medium LED PERFORMANCE DATA — UPLIGHT SKIRT + HOUSE SIDE SHIELD OPTION Performance Package Distribution Input Watts 30K (3000K CCT, 70 CRI)40K (4000K CCT, 70 CRI)50K (5000K CCT, 70 CRI)LLD @ 25ºC Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G 50k Hours 75k Hours 100k Hours P1 AG 105 8,036 77 1 0 2 8,266 79 1 0 2 8,368 80 1 0 2 0.97 0.97 0.96 AR 9,275 88 1 0 2 9,541 91 1 0 2 9,659 92 1 0 2 FG 8,948 85 1 0 2 9,204 88 1 0 2 9,318 89 1 0 2 FT 10,422 99 1 0 2 10,720 102 1 0 2 10,853 103 1 0 2 MG 10,580 101 1 0 2 10,884 104 1 0 2 11,018 105 1 0 2 MR 12,257 117 1 0 2 12,609 120 1 0 2 12,765 122 1 0 2 NG 11,030 105 1 0 2 11,347 108 1 0 2 11,487 109 1 0 2 NR 12,554 120 1 0 2 12,914 123 1 0 2 13,074 125 1 0 2 WG 9,525 91 1 0 2 9,798 93 1 0 2 9,919 94 1 0 2 WR 10,983 105 1 0 2 11,298 108 1 0 2 11,438 109 1 0 2 P2 AG 126 9,853 78 1 0 2 10,135 80 1 0 2 10,261 81 1 0 2 0.97 0.97 0.96 AR 11,373 90 1 0 2 11,699 93 1 0 2 11,844 94 1 0 2 FG 10,971 87 1 0 2 11,286 90 1 0 2 11,425 91 1 0 2 FT 12,778 101 1 0 2 13,145 104 1 0 2 13,307 106 1 0 2 MG 12,973 103 1 0 2 13,345 106 1 0 2 13,510 107 1 0 2 MR 15,029 119 1 0 2 15,460 123 1 0 2 15,651 124 1 0 2 NG 13,525 107 1 0 2 13,912 110 1 0 2 14,085 112 1 0 2 NR 15,393 122 1 0 2 15,835 126 1 0 2 16,031 127 1 0 2 WG 11,678 93 1 0 2 12,013 95 1 0 2 12,162 97 1 0 2 WR 13,467 107 2 0 2 13,853 110 2 0 2 14,024 111 2 0 2 P3 AG 155 11,647 75 1 0 2 11,981 77 1 0 2 12,129 78 1 0 2 0.97 0.96 0.96 AR 13,444 87 1 0 2 13,829 89 1 0 2 14,000 90 1 0 2 FG 12,969 84 1 0 2 13,340 86 1 0 2 13,506 87 1 0 2 FT 15,105 97 1 0 3 15,538 100 1 0 3 15,730 101 1 0 3 MG 15,335 99 1 0 2 15,774 102 1 0 2 15,970 103 2 0 2 MR 17,765 115 2 0 2 18,275 118 2 0 2 18,501 119 2 0 2 NG 15,987 103 1 0 2 16,445 106 1 0 2 16,649 107 1 0 2 NR 18,196 117 1 0 2 18,718 121 1 0 2 18,949 122 1 0 2 WG 13,805 89 2 0 2 14,200 92 2 0 2 14,376 93 2 0 2 WR 15,918 103 2 0 2 16,375 106 2 0 2 16,577 107 2 0 2 P4 AG 180 13,380 74 1 0 2 13,452 75 1 0 2 13,934 77 1 0 2 0.97 0.96 0.95 AR 15,444 86 1 0 3 15,457 86 1 0 3 16,083 89 1 0 3 FG 14,898 83 1 0 2 15,253 85 1 0 2 15,515 86 1 0 2 FT 17,352 96 1 0 3 17,705 98 1 0 3 18,071 100 1 0 3 MG 17,617 98 2 0 2 17,937 100 2 0 2 18,346 102 2 0 2 MR 20,409 113 2 0 3 20,784 115 2 0 3 21,254 118 2 0 3 NG 18,366 102 2 0 2 18,649 104 2 0 2 19,126 106 2 0 2 NR 20,903 116 2 0 2 21,201 118 2 0 2 21,769 121 2 0 2 WG 15,859 88 2 0 2 16,313 91 2 0 2 16,515 92 2 0 2 WR 18,287 102 2 0 2 18,617 103 2 0 2 19,044 106 2 0 2 Holophane | 3825 Columbus Rd., Granville, OH 43023 | Phone: 866-HOLOPHANE | www.holophane.com © 2019-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/28/22 Specifications are subject to change without notice. MGLEDM Page 11 of 11 MGLEDM Mongoose Medium LED PERFORMANCE DATA — UPLIGHT SKIRT + HOUSE SIDE SHIELD OPTION (continued) Performance Package Distribution Input Watts 30K (3000K CCT, 70 CRI)40K (4000K CCT, 70 CRI)50K (5000K CCT, 70 CRI)LLD @ 25ºC Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G 50k Hours 75k Hours 100k Hours P5 AG 206 15,037 73 1 0 2 15,468 75 1 0 2 15,659 76 1 0 2 0.96 0.96 0.95 AR 17,356 84 1 0 3 17,854 87 1 0 3 18,075 88 1 0 3 FG 16,743 81 2 0 3 17,223 84 2 0 3 17,437 85 2 0 3 FT 19,501 95 1 0 3 20,060 97 2 0 3 20,309 99 2 0 3 MG 19,798 96 2 0 2 20,366 99 2 0 2 20,618 100 2 0 2 MR 22,936 111 2 0 3 23,594 115 2 0 3 23,886 116 2 0 3 NG 20,641 100 2 0 2 21,232 103 2 0 2 21,495 104 2 0 2 NR 23,492 114 2 0 2 24,166 117 2 0 2 24,465 119 2 0 2 WG 17,823 87 2 0 2 18,333 89 2 0 2 18,561 90 2 0 2 WR 20,552 100 2 0 2 21,141 103 2 0 3 21,403 104 2 0 3 P6 AG 230 16,592 72 1 0 2 17,067 74 1 0 2 17,279 75 1 0 2 0.96 0.95 0.94 AR 19,151 83 1 0 3 19,700 86 1 0 3 19,944 87 1 0 3 FG 18,475 80 2 0 3 19,005 83 2 0 3 19,240 84 2 0 3 FT 21,518 94 2 0 4 22,135 96 2 0 4 22,409 97 2 0 4 MG 21,846 95 2 0 2 22,472 98 2 0 2 22,750 99 2 0 2 MR 25,308 110 2 0 3 26,034 113 2 0 3 26,356 115 2 0 3 NG 22,775 99 2 0 2 23,428 102 2 0 2 23,718 103 2 0 2 NR 25,922 113 2 0 2 26,665 116 2 0 3 26,995 117 2 0 3 WG 19,666 86 2 0 2 20,229 88 2 0 2 20,480 89 2 0 2 WR 22,677 99 2 0 3 23,327 101 2 0 3 23,616 103 2 0 3 P7 AG 255 18,201 71 1 0 3 18,723 73 2 0 3 18,955 74 2 0 3 0.96 0.95 0.93 AR 21,009 82 1 0 3 21,611 85 1 0 3 21,879 86 1 0 3 FG 20,267 79 2 0 3 20,848 82 2 0 3 21,106 83 2 0 3 FT 23,606 93 2 0 4 24,282 95 2 0 4 24,583 96 2 0 4 MG 23,965 94 2 0 3 24,652 97 2 0 3 24,957 98 2 0 3 MR 27,763 109 2 0 3 28,559 112 2 0 3 28,913 113 2 0 3 NG 24,984 98 2 0 2 25,701 101 2 0 2 26,019 102 2 0 2 NR 28,436 112 2 0 3 29,251 115 2 0 3 29,614 116 2 0 3 WG 21,573 85 2 0 2 22,192 87 2 0 2 22,467 88 2 0 2 WR 24,877 98 2 0 3 25,590 100 2 0 3 25,907 102 2 0 3 P8 AG 280 19,736 70 2 0 3 20,302 73 2 0 3 20,553 73 2 0 3 0.95 0.93 0.92 AR 22,781 81 2 0 3 23,434 84 2 0 4 23,724 85 2 0 4 FG 21,976 78 2 0 3 22,606 81 2 0 3 22,886 82 2 0 3 FT 25,596 91 2 0 4 26,330 94 2 0 4 26,656 95 2 0 4 MG 25,986 93 2 0 3 26,730 95 2 0 3 27,062 97 2 0 3 MR 30,104 108 2 0 3 30,967 111 2 0 4 31,351 112 3 0 4 NG 27,091 97 2 0 2 27,868 100 2 0 2 28,213 101 2 0 2 NR 30,834 110 2 0 3 31,718 113 2 0 3 32,111 115 2 0 3 WG 23,393 84 2 0 2 24,063 86 2 0 3 24,361 87 2 0 3 WR 26,975 96 3 0 3 27,748 99 3 0 3 28,091 100 3 0 3