HomeMy WebLinkAboutOther Departments 120121Civil Engineering Review Comments
☐Board of Adjustment ☒Planning Commission
Agenda Date: 01/13/2022
G File Number G-23-482
Alley Right-of-Way Abandonment 700 and 800 Blocks of Atkins Street
1. All neighbors are in agreement for the abandonment?
Z File Number Z-9646
Berryhill Bed and Breakfast-SUP 38 Point West Circle
1. No parking on sidewalk is allow. How will the additional traffic be able to be parked?
2. See City code for parking on streets
• Sec: 32-310.- Obstructing Traffic
i. No person shall stop, stand or park any vehicle upon a street, other than an
alley, in such a manner or under such conditions as to leave available less
than ten (10) feet of the width of the roadway for free movement of
vehicular traffic, except that a driver may stop temporarily during the
actual loading or unloading of passengers or when necessary, in obedience
to traffic regulations or traffic signs, or signals of a police officer. (Ord.
No. 19,921, § 1, 2-19-08)
Z File Number Z-8066-A
Little Maumelle Water Reclamation Facility-Revised CUP North of Cantrell/Divided Parkway Intersection
1. No comment
Z File Number Z-9648
Eagle Point Church SW Corner Mabelvale Pike and Sibley Hole Rd.
1. Right of way not shown please depict. Mabelvale Pike is shown as a Minor Arterial
with a right of way of 80 feet.
2. Right of way not shown please depict. Sibley Hole Rd. is shown as a Collector with a
right of way of 60 feet.
3. Boundary street improvements are required for both Mabelvale Pike and Sibley Hole
Rd.
4. Provide width of south drive.
5. Provide Sketch Grading and Drainage Plans.
6. Provide drainage calculations for the 24hr 25yr and 24hr 100yr storm events as well
as stage storage for the detention pond.
7. Provide full Civil Drawing Set.
8. Any work involving one (1) or more acres of disturbed area requires a State of
Arkansas NPDES permit. Contact the Arkansas Department of Environmental
Quality, NPDES branch at 501-682-0744 for applications and information about
General Stormwater Discharge Construction Permit #ARR150000.
9. A grading permit must be obtained prior to initiation of work. Grading permits are
issued by the Planning and Development Dept. at 723 West Markham Street after
approval of sediment and erosion control plans and soil loss calculations. Contact
Planning and Development Dept., Civil Engineering Private Development at 501-
371-4817 or at 501-918-5348 or Permits@littlerock.gov to schedule an appointment
for issuance or to answer any questions. Permit cost is based on total project area at
$100.00 for the less than ½ acre, $200.00 for ½ to 1 acre, and $200.00 for the first
acre and $100.00 for each additional acre for project greater than 1 acre.
Z File Number Z-5097-L
Chenal Valley Commercial Lot 1R-PCD SE corner of Hwy 10 and Chenal Parkway
1. Revise plans to take out both one-way drives on the east and west side. Widen center
drive for two-way traffic.
2. Reduce 2 entrances to 1.
Sec. 31-210. - General access and circulation.
(3)Other commercial streets. Minor commercial streets, commercial cul-de-sac
streets (greater than master street plan standard, when approved by the planning
commission), and loop commercial streets (street does not connect two separate
streets) the driveway spacing shall be two hundred (200) feet. Driveway spacing shall
be centerline or centerline to right-of-way line of an intersecting collector street or
street with a higher classification. Minimum spacing from the property line shall be
one hundred (100) feet. Maximum width of driveway is 26 feet. A lot will require
five hundred (500) feet of frontage for two (2) drives, if the lot is adjacent to an
intersecting collector street or street of a higher classification. A lot will require four
hundred (400) feet of frontage for two (2) drives, when a lot is adjacent to a
residential street or a minor commercial street. For lots less than two hundred (200)
feet in width a shared access is recommended for proposed plats and existing plats
recorded prior to January 1, 1999 are limited to one (1) driveway and the driveway
location shall be as approved by the public works department and shall be considerate
of adjacent lot access or conflicting turn movements from properties across the street.
Commercial streets are considered collector streets unless they conform to the minor
commercial street classification. Industrial streets are considered collector
streets.(4)Residential streets. Driveways for commercial uses approved to be located
on a residential street shall be spaced the same as for other commercial streets.
However, for properties that are located on existing platted residential lots of the
same size and character as adjoining residential properties the driveway requirements
are to be the same as listed in section 30-43: maximum width twenty (20) feet, the
drive shall be five (5) feet from property line and twenty-five (25) feet from the right-
of-way of an adjacent street.
3. Any work involving one (1) or more acres of disturbed area requires a State of
Arkansas NPDES permit. Contact the Arkansas Department of Environmental
Quality, NPDES branch at 501-682-0744 for applications and information about
General Stormwater Discharge Construction Permit #ARR150000.
4. A grading permit must be obtained prior to initiation of work. Grading permits are
issued by the Planning and Development Dept. at 723 West Markham Street after
approval of sediment and erosion control plans and soil loss calculations. Contact
Planning and Development Dept., Civil Engineering Private Development at 501-
371-4817 or at 501-918-5348 or Permits@littlerock.gov to schedule an appointment
for issuance or to answer any questions. Permit cost is based on total project area at
$100.00 for the less than ½ acre, $200.00 for ½ to 1 acre, and $200.00 for the first
acre and $100.00 for each additional acre for project greater than 1 acre.
Z File Number Z-8978-A
Lucy Self Storage-Revised Long-Form PD-C 10616 Stagecoach Rd.
1. Provide Sketch Grading and Drainage Plans.
2. Provide drainage calculations for the 24hr 25yr and 24hr 100yr storm events.
3. Any work involving one (1) or more acres of disturbed area requires a State of
Arkansas NPDES permit. Contact the Arkansas Department of Environmental
Quality, NPDES branch at 501-682-0744 for applications and information about
General Stormwater Discharge Construction Permit #ARR150000.
4. A grading permit must be obtained prior to initiation of work. Grading permits are
issued by the Planning and Development Dept. at 723 West Markham Street after
approval of sediment and erosion control plans and soil loss calculations. Contact
Planning and Development Dept., Civil Engineering Private Development at 501-
371-4817 or at 501-918-5348 or Permits@littlerock.gov to schedule an appointment
for issuance or to answer any questions. Permit cost is based on total project area at
$100.00 for the less than ½ acre, $200.00 for ½ to 1 acre, and $200.00 for the first
acre and $100.00 for each additional acre for project greater than 1 acre.
Z File Number Z-9480-B
Integrated Psych Solutions-Revised POD 218 NN McKinley St.
1. All driveways shall be concrete aprons per City Ordinance.
2. Due to the proposed use of the property, the Master Street Plan specifies that
McKinley Street for the frontage of this property must meet commercial street
standards. Dedicate right-of-way to 30 feet from centerline.
3. Sidewalks with appropriate handicap ramps are required to be constructed adjacent
McKinley St. in accordance with Sec. 31-175 of the Little Rock Code and the Master
Street Plan.
4. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. The width of driveway should not exceed
24 feet. Driveway spacing on commercial streets is 250 ft between driveways and 125
ft from the side property line. A driveway variance must be requested for the 2nd
driveway. The current driveway is about 150 ft from the existing driveway to the
south.
Z File Number Z-9641
SOTO-PCD 14616 Baseline Road
1. Reduce 2 entrances to 1 on Gregory Rd.
Sec. 31-210. - General access and circulation.
(3)Other commercial streets. Minor commercial streets, commercial cul-de-sac
streets (greater than master street plan standard, when approved by the planning
commission), and loop commercial streets (street does not connect two separate streets)
the driveway spacing shall be two hundred (200) feet. Driveway spacing shall be
centerline or centerline to right-of-way line of an intersecting collector street or street
with a higher classification. Minimum spacing from the property line shall be one
hundred (100) feet. Maximum width of driveway is 26 feet. A lot will require five
hundred (500) feet of frontage for two (2) drives, if the lot is adjacent to an intersecting
collector street or street of a higher classification. A lot will require four hundred (400)
feet of frontage for two (2) drives, when a lot is adjacent to a residential street or a minor
commercial street. For lots less than two hundred (200) feet in width a shared access is
recommended for proposed plats and existing plats recorded prior to January 1, 1999 are
limited to one (1) driveway and the driveway location shall be as approved by the public
works department and shall be considerate of adjacent lot access or conflicting turn
movements from properties across the street. Commercial streets are considered collector
streets unless they conform to the minor commercial street classification. Industrial
streets are considered collector streets.(4)Residential streets. Driveways for commercial
uses approved to be located on a residential street shall be spaced the same as for other
commercial streets. However, for properties that are located on existing platted
residential lots of the same size and character as adjoining residential properties the
driveway requirements are to be the same as listed in section 30-43: maximum width
twenty (20) feet, the drive shall be five (5) feet from property line and twenty-five (25)
feet from the right-of-way of an adjacent street.
2. Provide a separate Sketch Grading and Drainage Plan per Sec. 29.186(e).
3. Provide drainage calculations for the 24hr 25yr and 24hr 100yr storm events.
4. Any work involving one (1) or more acres of disturbed area requires a State of Arkansas
NPDES permit. Contact the Arkansas Department of Environmental Quality, NPDES
branch at 501-682-0744 for applications and information about General Stormwater
Discharge Construction Permit #ARR150000.
5. A grading permit must be obtained prior to initiation of work. Grading permits are issued
by the Planning and Development Dept. at 723 West Markham Street after approval of
sediment and erosion control plans and soil loss calculations. Contact Planning and
Development Dept., Civil Engineering Private Development at 501-371-4817 or at 501-
918-5348 or Permits@littlerock.gov to schedule an appointment for issuance or to answer
any questions. Permit cost is based on total project area at $100.00 for the less than ½
acre, $200.00 for ½ to 1 acre, and $200.00 for the first acre and $100.00 for each
additional acre for project greater than 1 acre.
6. Provide driveway widths.
7. Mabelvale Pike is shown as a Principal Arterial with a right of way of 110 feet.
8. Boundary street improvements are required for Baseline Rd.
Z File Number Z-9643
Williams-PD-R 4105 “A” Street
1. Resubmit legible plans for review.
TO: MONTE MOORE, DEVELOPMENT ADMINISTRATOR
FROM: TRACY SPILLMAN, PLANS DEVELOPMENT ADMINISTRATOR
SUBJECT: REVIEW OF THE BUFFER AND LANDSCAPE REQUIREMENTS OF
THE JANUARY 13, 2022, PLANNING COMMISION MEETING
DATE: NOV 29, 2021
1. Kanis and Atkins Rd G-23-484
1. No Comment
2. SEC Hwy 10 & Chenal Pkwy Z-5097-L
1. Site plan must comply with the City’s minimal landscape and buffer ordinance
requirements and the Highway 10 Scenic Corridor Overlay District.
2. The Highway 10 frontage (front yard) shall consist of a minimum of forty (40) feet of
landscaped area exclusive of right-of-way. The landscaped area shall contain organic
and/or combined man-made/organic features such as berms, brick walls and dense
plantings such that vehicular use areas are screened when viewed from an elevation of
forty-two (42) inches above the elevation of the adjacent street. Trees shall be planted
or be existing at least every twenty (20) feet and have a minimum of two (2) inches in
diameter when measured twelve (12) inches from the ground at time of planting.
Provide screening shrubs no less than thirty (30) inches in height at installation with an
average linear spacing of not less at three (3) feet within the required landscape area
3. A land use buffer six (6) percent of the average width / depth of the lot will be
required when an adjacent property has a dissimilar use of a more restrictive nature. A
portion of the property to the west is zoned R2. As a component of all land use buffer
requirements, opaque screening, whether a fence or other device, a minimum of six (6)
feet in height shall be required upon the property line side of the buffer. A minimum of
seventy (70) percent of the land use buffer shall be undisturbed. Easements cannot
count toward fulfilling this requirement. The plantings, existing and purposed, shall be
provided within the landscape ordinance of the city, section 15-81.
4. A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property or the right-of-way of any street. This strip shall be at least nine (9)
feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty
(30) linear feet of perimeter planting strip.
6. Building landscape areas shall be provided at the rate equivalent to planter strip three
(3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be
planted in the building landscape areas for each forty (40) linear feet of vehicular use
area abutting the building.
7. Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). The
minimum size of an interior landscape area shall be one hundred fifty (150) square feet
for developments with one hundred fifty (150) or fewer parking spaces. Interior
islands must be a minimum seven and one half (7 1/2) feet in width. Trees shall be
included in the interior landscape areas at the rate of one (1) tree for every twelve (12)
parking spaces.
8. A landscape irrigation system shall be required as per Highway 10 site design and
development standards.
9. The development of two (2) acres or more requires the landscape plan to be stamped
with the seal of a Registered Landscape Architect.
10.The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can
be given when preserving trees of six (6) inch caliper or larger.
3. 1 Mile N of Cantrell Rd & the Divide Parkway Z-8066-A
1. No Comment
4. 10616 Stagecoach Rd Z-8978-A
1. Any new site development must comply with the City’s minimal landscape and buffer
ordinance requirements and the requirements of the Central High Neighborhood
Overlay District.
2. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can
be given when preserving trees of six (6) inch caliper or larger.
5. 7900 Colonel Glenn Rd Z-9632
1. No Comment
6. 11921 Kanis Road Z-9636
1. No Comment
7. 8700 Block of I 30 Z-9637
1. No Comment
8. SW Corner of Rahling Road and Champagonlle Dr Z-4807-T
1. Any new site development must comply with the City’s minimal landscape and buffer
ordinance requirements.
2. A land use buffer six (6) percent of the average width / depth of the lot will be
required when an adjacent property has a dissimilar use of a more restrictive nature.
The properties to west are zoned R-2 or PDR. As a component of all land use buffer
requirements, opaque screening, whether a fence or other device, a minimum of six
(6) feet in height shall be required upon the property line side of the buffer. A
minimum of seventy (70) percent of the land use buffer shall be undisturbed. In
addition to the required screening, buffers are to be landscaped at the rate of one (1)
tree and three (3) shrubs for every thirty (30) linear feet. Easements cannot count
toward fulfilling this requirement. The plantings, existing and purposed, shall be
provided within the landscape ordinance of the city, section 15-81.
3. Street buffers will be required at six (6) percent of the average depth of the lot. The
minimum dimension shall be one-half (½) the full width requirement but in no case
be less than nine (9) feet.
4. Screening requirements will need to be met for the vehicular use areas adjacent to
street rights-of-way. Provide screening shrubs with an average linear spacing of not
less at three (3) feet within the required landscape area. Provide trees with an average
linear spacing of not less than thirty (30) feet.
5. A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property, or the right-of-way of any street. This strip shall be at least nine
(9) feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every
thirty (30) linear feet of perimeter planting strip.
6. Building landscape areas shall be provided at the rate equivalent to planter strip three
(3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be
planted in the building landscape areas for each forty (40) linear feet of vehicular use
area abutting the building.
7. Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). For
developments with more than one hundred fifty (150) parking spaces the minimum
size of an interior landscape area shall be three hundred (300) square feet. Interior
islands must be a minimum of seven and one half (7 1/2) feet in width. Trees shall be
included in the interior landscape areas at the rate of one (1) tree for e very twelve
(12) parking spaces.
8. An automatic irrigation system to water landscaped areas shall be required for
developments of one (1) acre or larger.
9. The development of two (2) acres or more requires the landscape plan to be stamped
with the seal of a Registered Landscape Architect.
10. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can
be given when preserving trees of six (6) inch caliper or larger.
9. 11421 Stagecoach Rd Z-7786-C
1. No Comment
10. 1417 S Park Street Z-7965-A
3. Any new site development must comply with the City’s minimal landscape and buffer
ordinance requirements and the requirements of the Central High Neighborhood
Overlay District.
4. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can
be given when preserving trees of six (6) inch caliper or larger.
11. 500 S University Z-7965-A
1. No Comment
12. 3717 W Capitol Z-9634
1. No Comment
13. 1105 Fair Park Blvd Z-9634
1. Any new site development must comply with the City’s minimal landscape and buffer
ordinance requirements.
2. Street buffers will be required at six (6) percent of the average depth of the lot. The
minimum dimension shall be one-half (½) the full width requirement but in no case
be less than nine (9) feet.
The street buffers are deficient. The property is approximately 130 feet in width.
A minimum 7.8-foot buffer is required adjacent to the W 11th St right-of-way.
The property is approximately 275- feet in length. A minimum 16.5-foot buffer is
required adjacent to the S Tyler St right-of-way.
3. A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property or the right-of-way of any street A twenty-five (25) percent
reduction of the landscape provisions can be taken for developments within mature
areas. In these areas it is allowable for perimeter planting strips to be a minimum of
six (6) feet nine (9) inches wide. One (1) tree and three (3) shrubs or vines shall be
planted for every thirty (30) linear feet of perimeter planting strip.
The north perimeter landscape strip adjacent to the W 11th St right-of-way is
deficient.
4. Screening requirements will need to be met for the vehicular use areas adjacent to
street rights-of-way. Provide screening shrubs with an average linear spacing of not
less at three (3) feet within the required landscape area. Provide trees with an average
linear spacing of not less than thirty (30) feet.
5. Building landscape areas shall be provided at the rate equivalent to planter strip three
(3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be
planted in the building landscape areas for each forty (40) linear feet of vehicular use
area abutting the building.
6. Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). The
minimum size of an interior landscape area shall be one hundred fifty (150) square
feet for developments with one hundred fifty (150) or fewer parking spaces. Interior
islands must be a minimum seven and one half (7 1/2) feet in width. Trees shall be
included in the interior landscape areas at the rate of one (1) tree for every twelve (12)
parking spaces.
7. An automatic irrigation system to water landscaped areas shall be required for
developments of one (1) acre or larger.
8. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can
be given when preserving trees of six (6) inch caliper or larger.
13. 18021 Cantrell Road Z-9642
1. Site plan must comply with the City’s minimal landscape and buffer ordinance
requirements and the Highway 10 Scenic Corridor Overlay District.
2. The Highway 10 frontage (front yard) shall consist of a minimum of forty (40) feet of
landscaped area exclusive of right-of-way. The landscaped area shall contain organic
and/or combined man-made/organic features such as berms, brick walls and dense
plantings such that vehicular use areas are screened when viewed from an elevation of
forty-two (42) inches above the elevation of the adjacent street. Trees shall be planted
or be existing at least every twenty (20) feet and have a minimum of two (2) inches in
diameter when measured twelve (12) inches from the ground at time of planting.
Provide screening shrubs no less than thirty (30) inches in height at installation with an
average linear spacing of not less at three (3) feet within the required landscape area
3. A land use buffer six (6) percent of the average width / depth of the lot will be
required when an adjacent property has a dissimilar use of a more restrictive nature.
The properties to the south and west are zoned R2. As a component of all land use
buffer requirements, opaque screening, whether a fence or other device, a minimum of
six (6) feet in height shall be required upon the property line side of the buffer. A
minimum of seventy (70) percent of the land use buffer shall be undisturbed.
Easements cannot count toward fulfilling this requirement. The plantings, existing and
purposed, shall be provided within the landscape ordinance of the city, section 15-81.
4. Rear and side yards shall have a landscaped buffer averaging a minimum of twenty-
five (25) feet from the property line.
The west side yard is deficient.
5. A perimeter planting strip is required along any side of a vehicular use area that abuts
adjoining property or the right-of-way of any street. This strip shall be at least nine (9)
feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty
(30) linear feet of perimeter planting strip.
6. Building landscape areas shall be provided at the rate equivalent to planter strip three
(3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be
planted in the building landscape areas for each forty (40) linear feet of vehicular use
area abutting the building.
7. Eight percent (8%) of the vehicular use area must be designated for green space; this
green space needs to be evenly distributed throughout the parking area(s). The
minimum size of an interior landscape area shall be one hundred fifty (150) square feet
for developments with one hundred fifty (150) or fewer parking spaces. Interior
islands must be a minimum seven and one half (7 1/2) feet in width. Trees shall be
included in the interior landscape areas at the rate of one (1) tree for every twelve (12)
parking spaces.
8. A landscape irrigation system shall be required as per Highway 10 site design and
development standards.
9. The development of two (2) acres or more requires the landscape plan to be stamped
with the seal of a Registered Landscape Architect.
10.The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can
be given when preserving trees of six (6) inch caliper or larger.
To: Torrence Thrower Date: November 18, 2021
From: Captain Tony Rhodes and Fire Marshal Derek Ingram
Comment for the following Locations:
G-23-482 Alley Right-of-Way Abandonment Blocks 16 and 17 Gibraltar Heights
Addition
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in
grade except as approved by the fire chief. If the grade exceeds 10 percent,
approval will be denied and the applicant must submit request to be reviewed
by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
One- or Two-Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two-Family
dwelling residential developments. Developments of one- or two-family dwellings where the number of
dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access
roads, and shall meet the requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling units on a single public or private fire apparatus
access road and al dwelling units are equipped throughout with an approved automatic
sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the
Arkansas Fire Code, access from two directions shall not be required.
2. The number of dwelling units on a single fire apparatus access road shall not be increased
unless fire apparatus access roads will connect with future development, as determined by
the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 –
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and
Distribution of Fire Hydrants as per Table C105.1.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess
of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Z-9646 Berryhill Bed and Breakfast – Special Use Permit38 Point West Circle
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in
grade except as approved by the fire chief. If the grade exceeds 10 percent,
approval will be denied and the applicant must submit request to be reviewed
by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire apparatus access roads
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30
feet or three stories in height shall have at least two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross
building area of more than 62,000 square feet shall be provide with two separate and approved fire
apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet that have a single
approved fire apparatus access road when all building are equipped throughout with approved
automatic sprinkler systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a
distance apart equal to not less than one half of the length of the maximum overall diagonal dimension
of the lot or area to be served, measured in a straight line between accesses.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 –
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N Ingram 501-918-3756
Number and Distribution of Fire Hydrants as per Table C105.1.
Z-8066-A Little Maumelle Water Reclamation Facility – Revised Conditional Use
Permit Approximately 1 mile, north of the Cantrell Road / The Divide Parkway
Intersection
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in
grade except as approved by the fire chief. If the grade exceeds 10 percent,
approval will be denied and the applicant must submit request to be reviewed
by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire apparatus access roads
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30
feet or three stories in height shall have at least two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross
building area of more than 62,000 square feet shall be provide with two separate and approved fire
apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet that have a single
approved fire apparatus access road when all building are equipped throughout with approved
automatic sprinkler systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a
distance apart equal to not less than one half of the length of the maximum overall diagonal dimension
of the lot or area to be served, measured in a straight line between accesses.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 –
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N Ingram 501-918-3756
Number and Distribution of Fire Hydrants as per Table C105.1.
Z-9648 Eagle Point Church – Conditional Use Permit Southwest corner of Mabelvale
Pike and Sibley Hole Road
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in
grade except as approved by the fire chief. If the grade exceeds 10 percent,
approval will be denied and the applicant must submit request to be reviewed
by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire apparatus access roads
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30
feet or three stories in height shall have at least two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross
building area of more than 62,000 square feet shall be provide with two separate and approved fire
apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet that have a single
approved fire apparatus access road when all building are equipped throughout with approved
automatic sprinkler systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a
distance apart equal to not less than one half of the length of the maximum overall diagonal dimension
of the lot or area to be served, measured in a straight line between accesses.
30’ Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D105.1 – D105.4
D105.1 Where Required. Where the vertical distance between the grade plane and the highest
roof surface exceed 30’, approved aerial fire apparatus access roads shall be provided. For the purposes
of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched
roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of
26’, exclusive of shoulders, in the immediate vicinity of the building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes meeting this condition
shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be
positioned parallel to one entire side of the building. The side of the building on which the aerial fire
apparatus access road is positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire
apparatus access road or between the aerial fire apparatus road and the building. Other obstructions
shall be permitted to be places with the approval of the fire code official.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess
of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access
roads shall comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one person.
4. Gate components shall be maintained in an operable condition at all times and replaces or
repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire department personnel
for emergency access. Emergency opening devices shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are
capable of being opened by means of forcible entry tools or when a key box containing the keys
to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code official
8. Electric gate operators, where provided, shall be listed in accordance with UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and installed to comply
with requirements of ASTM F 2200.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 –
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N Ingram 501-918-3756
Number and Distribution of Fire Hydrants as per Table C105.1.
Z-5097-L Chenal Valley Commercial Lot 1R- PCD Southeast corner of Highway 10
and Chenal Parkway
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in
grade except as approved by the fire chief. If the grade exceeds 10 percent,
approval will be denied and the applicant must submit request to be reviewed
by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire apparatus access roads
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30
feet or three stories in height shall have at least two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross
building area of more than 62,000 square feet shall be provide with two separate and approved fire
apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet that have a single
approved fire apparatus access road when all building are equipped throughout with approved
automatic sprinkler systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a
distance apart equal to not less than one half of the length of the maximum overall diagonal dimension
of the lot or area to be served, measured in a straight line between accesses.
30’ Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D105.1 – D105.4
D105.1 Where Required. Where the vertical distance between the grade plane and the highest
roof surface exceed 30’, approved aerial fire apparatus access roads shall be provided. For the purposes
of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched
roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of
26’, exclusive of shoulders, in the immediate vicinity of the building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes meeting this condition
shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be
positioned parallel to one entire side of the building. The side of the building on which the aerial fire
apparatus access road is positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire
apparatus access road or between the aerial fire apparatus road and the building. Other obstructions
shall be permitted to be places with the approval of the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 –
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N Ingram 501-918-3756
Number and Distribution of Fire Hydrants as per Table C105.1.
Z-8978-A Lucy Self Storage – Revised Long-Form PD-C10616 Stagecoach Road
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in
grade except as approved by the fire chief. If the grade exceeds 10 percent,
approval will be denied and the applicant must submit request to be reviewed
by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire apparatus access roads
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30
feet or three stories in height shall have at least two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross
building area of more than 62,000 square feet shall be provide with two separate and approved fire
apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet that have a single
approved fire apparatus access road when all building are equipped throughout with approved
automatic sprinkler systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a
distance apart equal to not less than one half of the length of the maximum overall diagonal dimension
of the lot or area to be served, measured in a straight line between accesses.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess
of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access
roads shall comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one person.
4. Gate components shall be maintained in an operable condition at all times and replaces or
repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire department personnel
for emergency access. Emergency opening devices shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are
capable of being opened by means of forcible entry tools or when a key box containing the keys
to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code official
8. Electric gate operators, where provided, shall be listed in accordance with UL 325.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 –
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N Ingram 501-918-3756
Number and Distribution of Fire Hydrants as per Table C105.1.
Z-9480-B Integrated Psych Solutions - Revised POD218 North McKinley Street
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in
grade except as approved by the fire chief. If the grade exceeds 10 percent,
approval will be denied and the applicant must submit request to be reviewed
by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire apparatus access roads
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30
feet or three stories in height shall have at least two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross
building area of more than 62,000 square feet shall be provide with two separate and approved fire
apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet that have a single
approved fire apparatus access road when all building are equipped throughout with approved
automatic sprinkler systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a
distance apart equal to not less than one half of the length of the maximum overall diagonal dimension
of the lot or area to be served, measured in a straight line between accesses.
30’ Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D105.1 – D105.4
D105.1 Where Required. Where the vertical distance between the grade plane and the highest
roof surface exceed 30’, approved aerial fire apparatus access roads shall be provided. For the purposes
of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched
roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of
26’, exclusive of shoulders, in the immediate vicinity of the building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes meeting this condition
shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be
positioned parallel to one entire side of the building. The side of the building on which the aerial fire
apparatus access road is positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire
apparatus access road or between the aerial fire apparatus road and the building. Other obstructions
shall be permitted to be places with the approval of the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 –
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N Ingram 501-918-3756
Number and Distribution of Fire Hydrants as per Table C105.1.
Z-9641 SOTO – PCD 14616 Baseline Road
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in
grade except as approved by the fire chief. If the grade exceeds 10 percent,
approval will be denied and the applicant must submit request to be reviewed
by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire apparatus access roads
as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30
feet or three stories in height shall have at least two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross
building area of more than 62,000 square feet shall be provide with two separate and approved fire
apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet that have a single
approved fire apparatus access road when all building are equipped throughout with approved
automatic sprinkler systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a
distance apart equal to not less than one half of the length of the maximum overall diagonal dimension
of the lot or area to be served, measured in a straight line between accesses.
30’ Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D105.1 – D105.4
D105.1 Where Required. Where the vertical distance between the grade plane and the highest
roof surface exceed 30’, approved aerial fire apparatus access roads shall be provided. For the purposes
of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched
roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of
26’, exclusive of shoulders, in the immediate vicinity of the building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes meeting this condition
shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be
positioned parallel to one entire side of the building. The side of the building on which the aerial fire
apparatus access road is positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire
apparatus access road or between the aerial fire apparatus road and the building. Other obstructions
shall be permitted to be places with the approval of the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 –
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N Ingram 501-918-3756
Number and Distribution of Fire Hydrants as per Table C105.1.