Loading...
HomeMy WebLinkAboutZ-9624 PC Action Letter - Approved With Conditions 122221Department of Planning and Development y 723 West Markham Street ' Little Rock, Arkansas 72201-1334 hs 1- Phone: (501)371-4790 Fax: (501)371-4546 December 14, 2021 PIR Capital, Inc. Long Dang 3225 McLeod, Suite 100 Las Vegas, NV 89121 Planning Development Building Codes Re: File No. Z-9624 Washington Manufactured Home — CUP; 17220 Crystal Valley Road Dear Mr. Dang: This is to advise you that in connection with your request concerning the above referenced file number the following action was taken by the Planning Commission at its meeting on December 9, 2021: X Approved with conditions. Recommended approval with conditions. Recommended approval as submitted. Denied your request as submitted. Deferred to the Other: Meeting. If you have any questions please do not hesitate to contact me at 371-4792. Respectfully, Mo dteS'� Development Administrator December 9, 2021 ITEM NO.: A FILE NO.: Z-9624 NAME: Washington Manufactured Home — Conditional Use Permit LOCATION: 17220 Crystal Valley Road DEVELOPER: Long Dang PIR Capital, Incorporated 3225 McLeod, Suite 100 Las Vegas, NV 89121 OWNER/AUTHORIZED AGENT: Long Dang PIR Capital, Incorporated 3225 McLeod, Suite 100 Las Vegas, NV 89121 SURVEYOR/ENGINEER: Brooks Surveying, Incorporated 20820 Arch Street Pike Hensley, AR 72065 AREA: 1.75 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF WARD: 7 PLANNING DISTRICT: 16 CENSUS TRACT: 41.04 CURRENT ZONING: R-2 (Single-family District) VARIANCEMAIVERS: None requested. A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT: The applicant is requesting a conditional use permit to allow for the placement of a double -wide manufactured home on the 1.75 acres, R-2 zoned property. B. EXISTING CONDITIONS: The property is currently undeveloped and mostly wooded. December 9, 2021 ITEM NO.: A [Cont.) FILE NO.: Z-9624 C. NEIGHBORHOOD COMMENTS: All owners of property located within 200 feet of the site and all neighborhood associations registered with the City of Little Rock were notified of the public hearing. D. ENGINEERING COMMENTS: 1. Need revised site plan showing drive and residence. 2. Additional right-of-way of 30 feet to be dedicated per Master Street Plan. 3. Driveway should be placed on the South property line to prevent a sight distance issue. E. UTILITIES/FIRE DEPARTMENTIPARKSICOUNTY PLANNING: Little Rock Water Reclamation Authori : No comments. Entergy: No comments received. CenterPoint Energy: No comments. AT & T: No comments received. Central Arkansas Water: No comments received. Fire Department: Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. If the grade exceeds 10 percent, approval will be denied and the applicant must submit request to be reviewed by Fire Chief for Approval. 2 December 9, 2021 ITEM NO.: A (Cont.) FILE NO.: Z-9624 Loading Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. One- or Two -Family Residential Developments. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Exceptions: 1. Where there are more than 30 dwelling units on a single public or private fire apparatus access road and all dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram 501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1. Parks and Recreation: No comments received. County Planning: 1. Provide PERC Test for mobile home's septic system before requesting address. 2. Meet the City's front, side and rear yard setbacks. F. BUILDING CODES/LANDSCAPE: Building Code: No comments received. 3 December 9, 2021 ITEM NO.: A (Cont.) FILE NO.: Z-9624 Landscape: No comments. G. TRANSPORTATION/PLANNING: Rock Region Metro: No comments received. Planning Division: No comments. H. ANALYSIS: The applicant is requesting a conditional use permit to allow for the placement of a double -wide manufactured home on R-2 zoned property located at 17220 Crystal Valley Road. The property is located within the City's Extra -Territorial Zoning Jurisdiction (ETJ). The property is comprised of 1.75 acres and is located on the east side of Crystal Valley Road. The property is currently undeveloped. The applicant proposes to locate a 28 foot by 72 foot double -wide manufactured home located in the southeast corner of the property. It will be located 330 feet back from the front (west) property line after a right-of-way dedication from Crystal Valley Road. The proposed home will be located 150 feet back from the north property line, 25 feet from the rear (east) property line and 10 feet from the south property line. The proposed home will comply with all ordinance required setbacks. The proposed setbacks leave ample room for decks, porches, steps etc. The proposed home will lie southeast to an existing developed, R-2 zoned piece of property comprising of 0.62 acres. The existing single-family residence lies approximately 100 feet from the nearest point of the proposed manufactured home. Access to the property will be via a 12 foot wide driveway from Crystal Valley Road. A 16 foot by 20 foot parking pad will be located on the east side of the proposed residence. The proposed manufactured home must comply with the following minimum siting standards as per Section 36-254(d)(5) of the City's Zoning Ordinance: a. A pitched roof of three (3) in twelve (12) or fourteen (14) degrees or greater. b. Removal of all transport elements. c. Permanent foundation. d. Exterior wall finished so as to be compatible with the neighborhood. e. Orientation compatible with placement of adjacent structures. f. Underpinning with permanent materials. 4 December 9, 2021 ITEM NO.: A Cont. FILE NO.: Z-9624 g. All homes shall be multisectional. h. Off street parking per single-family dwelling standard. The applicant provided responses and additional information to all issues raised during staffs review of the application. To staff's knowledge, there are no outstanding issues. The applicant is requesting no variances with the proposed CUP. Staff is supportive of the requested conditional use permit to allow a multi -sectional manufactured home at 17220 Crystal Valley Road. Staff views the request as reasonable. The proposed manufactured home will not be out of character with other single-family residential structures in this general area. Most of the homes in the immediate area are one-story structures which were constructed 25 years or more ago. There are two existing single -wide manufactured homes located at 17600 Crystal Valley Road, four (4) properties to the north of the subject property. There is an existing Planned Office Development (POD) residential building to the west of the subject property. Staff believes the proposed manufactured home will have no adverse impact on the surrounding properties in the general area. STAFF RECOMMENDATION: Staff recommends approval of the requested CUP to allow a multi -sectional manufactured home at 17220 Crystal Valley Road, subject to the following conditions: 1. Compliance with the comments and conditions noted in paragraph D and E, and the staff analysis, of the agenda staff report. 2. Compliance with the manufactured home minimum siting standards as noted in Section 36-254(d)(5) of the code. PLANNING COMMISSION ACTION: (NOVEMBER 18, 2021) Staff informed the Commission that the applicant failed to send the required notifications to surrounding property owners. Staff recommended the application be deferred to the December 9, 2021 agenda. The item was placed on the Consent Agenda and deferred as recommended by staff. The vote was 9 ayes, 0 nays and 2 absent. PLANNING COMMISSION ACTION: (DECEMBER 9, 2021) The applicant was present. There were no persons present registered in support or opposition. Staff presented the item and a recommendation of approval as outlined in the 5 December 9, 2021 ITEM NO.: A Cont. FILE NO.: Z-9624 "staff recommendation" above. There was no further discussion. The item was placed on the Consent Agenda and approved as recommended by staff, including all staff comments and conditions. The vote was 9 ayes, 0 nays and 2 absent. C