HomeMy WebLinkAboutPW Agenda Comments Public Works Review Comments
Planning Commission Board of Adjustment
Agenda Date: 9-24-20
Z File Number Z-3457-A Riverwalk Properties @ Cumberland & 17th 17th St. & Cumberland St. (3 lots)
1 Confirm collection??
2 Place a "No Parking" sign on Cumberland St. 25 ft from 17th St. to prevent parking on Cumberland St. within of 17th St. intersection. Also, "No Parking" signage should be installed on 17th St. adjacent to the subject property.
3 A 20 feet radial dedication of right-of-way is required at the intersection of Cumberland St. and 17th St.
4 With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to Cumberland Street including 5-foot sidewalks with planned development. Maintain the street width and replaced damaged or missing curb and gutter. The back of the sidewalk should be placed on the property line.
5 With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to 17th St. including 5-foot sidewalks with planned development. Maintain the street width and replace damaged or missing curb and gutter. A 5 ft sidewalk should be placed 3 ft from the property line or an 8 ft sidewalk placed at the property line.
6 Sidewalks with appropriate handicap ramps are required in accordance with Sec. 31-175 of the Little Rock Code and the Master Street Plan.
7 The proposed drive aisle is 18 ft in width. Fire Code requires at least a 20 ft width.
8 Repair or replace any curb, gutter, sidewalk and access ramps that are damaged and not in compliance with ADA recommendations in the public right-of-way prior to occupancy.
9 Obtain a franchise agreement from Public Works (Bennie Nicolo, 371-4818) for the private improvements (awnings, signs, shrubs, landscaping and trees) located in the right-of-way.
Z File Number Z-4933-J Splash Carwash and Oil Rev PCD 15707 Chenal Parkway
1 Kanis Rd is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required.
2 Repair or replace any curb, gutter, sidewalk and access ramps that are damaged and not in compliance with ADA recommendations in the public right-of-way prior to occupancy.
3 Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy.
4 In accordance with Section 32-8, no obstruction to visibility such as signage shall be located within a triangular area 50 ft back from the intersecting right-of-way line (or intersecting tangent lines for radial dedications) at the intersections.
Friday, August 14, 2020 Page 1 of 3
5 Check traffic flow arrows within the site south of existing building.
Z File Number Z-5096-D Woodlands Edge Rezoning POD& PCD to O3 & C3 Kanis Road and Woodlands Trail
1 Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required.
Z File Number Z-567-A 1800 E 3rd St. rezoning 1800 E 3rd St.
0 no comment
Z File Number Z-8089-A Butler PCD 12601 Alexander Road
1 Alexander Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of- way 45 feet from centerline will be required.
2 With future site development or expansion, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to these streets including 5-foot sidewalks with planned development.
3 Is the eastern paved driveway located within an access easement?
4 A concrete driveway apron should be constructed for at least 10 ft in length on the west driveway from the edge of pavement of Alexander Road.
Z File Number Z-9529 Ali-PRD 7520 N. Chicot Road
1 Repair or replace any curb, gutter, sidewalk and access ramps that are damaged and not in compliance with ADA recommendations in the public right-of-way prior to occupancy.
2 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is construction of buildings proposed to be phased? If phased, is a variance being requested to advance grade the entire property with construction of Phase 1?
3 If the NW corner of the property is within the 100 year floodplain, a special Grading Permit for Flood Hazard Areas will be required per Sec. 8-283 prior to construction. Confirm floodplain is not on the property.
4 Storm water detention will not apply to the proposed development.
5 Obtain permits prior to doing any street cuts or curb cuts. Obtain barricade permit prior to doing any work in the right-of-way. Contact Traffic Engineering at (501) 379-1805 (Travis Herbner) for more information.
6 Hauling of fill material on or off site over municipal streets and roads requires approval prior to a grading permit being issued. Contact Public Works Traffic Engineering at 621 S. Broadway, (501) 379-1805 (Travis Herbner) for more information.
Friday, August 14, 2020 Page 2 of 3
7 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections 30-43 and 31-210. The width of driveway must not exceed 36 feet. Per CLR code, driveway spacing on collector streets is 250 ft between driveways and intersection and 125 ft from side property lines. A variance is needed for the 2 driveways.
8 The proposed parking lot drive aisle should be moved out of the public right-of-way.
9 Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy.
10 Collection??
11 Pedestrian access should be provided from the public right-of-way to the proposed development.
12 Correct spelling of Chicot Road on plans.
Z File Number Z-9530 4920 Frazier Pike rezoning AF to R4 4920 Frazier Pike
1 Frazier Pike is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required.
Friday, August 14, 2020 Page 3 of 3