HomeMy WebLinkAboutSite Plan Revised 082520"oo,
41 /
�' \ •�
\\------ -----
♦*
♦i i 3
'
�.�
I I I I
i
I
i I I I
% EXISTING BUILDING I EASEMENT/BUILDING LINE
00
I I � I I
J I I I
w i
-I
% NEW DUMPSTER PAD Z I I I
LOCATION FOR CARWASH I I
� I
NEW LIGHT POLE w
(+l-) 99.80' - — - I (+/-) 463.31'
b 60.1T i I POLELIGH36.33'
/ lg r ER 10.6' EQUIP.
% ROOM I I
20
R� O o 0 193.95' I i
o s`
.♦ 125 FT BELT TUNNEL I 20.00' /
�13 I U)
NEW 8'-0" TALL x 12'-0" WIDE
NEW LIGHT POLE % • / % I ♦ 125 FT BELT TUNNEL ♦ I i GROUND -MOUNTED SIGN
24.32' 3� �6Q� N
I
NEW DUMPSTER PAD / j l f I OO 16.00, 18.00'
LOCATION FOR LUBE / / r 24.00' �� IE 31 I I
CENTER / / / f o, }
- ILO
DETAIL
r rn I AREA I ? I !
W
Q ♦ I ♦ ♦ � o o Y I L)/ W 20.19' Q I w j I
/ / I o o U �pO Ln I o0
/ z _ o- EXISTING BUILDING 0
/ I CUSTOMER
Q _ WAITING TO BE REMODELED 0 OFFIC / ETC. I I z
/ a ilk
NFW�Ug�C R78.10' * t t 18.00' 2�54 I R800• Iw
N / Opg SQ. FT TFR ■
I � R 2.0p• I
9.00' F I 'A2 18.08I bA.92' 1
_ Q-
// 45.44' 66.86, 25 INDOOR VACUUMS ♦ M I 00'
II
r- 4 PARKINGIcb,
/ / cfl Q ♦ ('n - / NEW L,GHT
CZ I POLE
V&/�p0 i I - -- -- -----
22.00' 000
FM= 1 EXISTING 6" DIP _ I- FM— —
75.40' I I
II I LOT 1 B EXISTING FIRE
NEW LIGHT II I li EXISTING DRIVE M(+/-) 2.20 ACRES HYDRANT — — - _ -
�
/ NEW LIGHT POLE POLE I I TO REMAIN • — • — -
LOT 1 C
(+/-)0.83ACRES II i► I t I_._._._._
i I EXISTING MANHOLE u� - — - _
/ NEW PROPOSED II L_____I _,_._--•— - (+I-)397.84'
LOT LINES—
/ APPROX. LOCATION OF I _ • — • — ' - - I
EXISTING SIGNAGE TO '
REMAIN
WELLINGTON HILLS RD (90' RIW) I 2
I '
SITE PLAN 30 15 0 30 60FT
SCALE: 1 "=30'-0"
SCALE: 1" = 30'-0"
W
W
a
J
z
W
U
GENERAL CONSTRUCTION NOTES
z
—
A. THE CONTRACTOR WILL BE HELD SOLELY RESPONSIBLE FOR DAMAGES
OCCURRING TO ANY PROPERTY DURING THE CONSTRUCTION OF THIS
( j
PROJECT. SAID CONTRACTOR SHALL TAKE ALL NECESSARY
z
PRECAUTIONS TO PREVENT PROPERTY DAMAGE.
R
w
B. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES,
w
THE CONTRACTOR WILL SOLELY AND COMPLETELY BE RESPONSIBLE FOR
z
CONDITIONS OF THE JOB SITE, INCLUDING SAFETY WORK. THIS REQUIREMENT
L7
WILL APPLY CONTINUOUSLY AND WILL NOT BE LIMITED TO NORMAL WORKING
z
HOURS.
Lu
V)
HE DUTY OF THE CITY OF LITTLE ROCK & CENTRAL ARKANSAS WATER
O CONDUCT CONSTRUCTION INSPECTIONER REVIEWS OF THE
w
ONTRACTOR'S PERFORMANCE IS NOT AN INSPECTION OR REVIEW OF THE
DEQUACY OF THE CONTRACTOR'S SAFETY MEASURES IN, ON, OR NEAR THE
ONSTRUCTION SITE.
J
C. A L WATER AND SEWER IMPROVEMENTS SHALL BE CONSTRUCTED IN
ACCORDANCE WITH THE LATEST REVISION TO CENTRAL ARKANSAS WATER'S &
L TTLE ROCK WATER RECLAMATION AUTHORITY'S STANDARD SPECIFICATIONS.
D. T E CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION
A D/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS
B SED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE
P SSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT
T BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST
C ILL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE
A Y EXCAVATION TO REQUEST EXACT FIELD LOCATION OF ALL UTILITIES.
IT HALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL
E ISTING UTILITIES WHICH CONFLICT WITH PROPOSED IMPROVEMENTS REVISION:
S OWN ON THE PLAN.
E. CONTRACTOR IS TO REMOVE AND DISPOSE OF ALL DEBRIS, RUBBISH, AND
OT ER MATERIALS RESULTING FROM PREVIOUS AND CURRENT DEMOLITION
OP RATIONS. DISPOSAL WILL BE IN ACCORDANCE WITH ALL LOCAL, STATE
AN /OR FEDERAL REGULATIONS GOVERNING SUCH OPERATIONS.
PRI R TO INSTALLATION OF ANY UTILITIES, THE CONTRACTOR IS TO
EX AVATE, VERIFY AND CALCULATE ALL CROSSINGS AND INFORM ANY AND
AL UTILITIES OF ANY CONFLICTS PRIOR TO CONSTRUCTION.
CO STRUCTION SHALL NOT START ON ANY WATER UTILITY TIE-INS UNTIL
AP ROVAL IS GIVEN BY CENTRAL ARKANSAS WATER. SAID CONTRACTOR
SH LL NOT OPERATE ANY VALVE, HYDRANT, OR WATER UTILITY APPURTENANC
NO SHALL HE ATTACH TO OR TAP ANY WATER UTILITY MAIN WITHOUT
APP OVAL. THE CONTRACTOR SHALL BEAR THE COST AND CONSEQUENCE OF
ANYI DISRUPTION OF UTILITY OPERATION CAUSED BY CONSTRUCTION.
H. FIBEOPTIC CABLE ON AND/OR ADJACENT TO THIS SITE WERE NOT LOCATED
Y E SURVEY AND ARE NOT SHOWN. IT IS THE RESPONSIBILITY OF THE
ON RACTOR TO LOCATE ANY FIBER OPTIC CABLES ASSOCIATED WITH THIS
ITE AND TAKE ALL NECESSARY AND REQUIRED PRECAUTIONS TO PROTECT
NY XISTING FIBER OPTIC CABLES. CONTRACTORS SHALL COORDINATE ALL
FF RTS WITH OWNER OF FIBER OPTIC CABLES OR THEIR DESIGNATED
EP ESENTATIVE.
J. T E ONTRACTOR IS RESPONSIBLE FOR CONTACTING "ONECALL" SERVICE
T M RK ALL UTILITIES PRIOR TO ANY DEMOLITION, EARTHWORK, OR UTILITY
ORK ON THIS SITE.
K. R PAIR OR REPLACE ANY CURB, GUTTER, SIDEWALK AND ACCESS RAMPS
T AT RE DAMAGED AND NOT IN COMPLIANCE WITH ADA RECOMMENDATIONS
I TH PUBLIC RIGHT-OF-WAY PRIOR TO OCCUPANCY.
L. D MA E TO PUBLIC AND PRIVATE PROPERTY DUE TO HAULING OPERATIONS
O OP RATION OF CONSTRUCTION RELATED EQUIPMENT FROM A NEARBY
C NS RUCTION SITE SHALL BE REPAIRED BY THE RESPONSIBLE PARTY
P IOR O ISUANCE OF A CERTIFICATE OF OCCUPANCY.
M. I
AC
ORDANCE WITH SECTION 32-9, NO OBSTRUCTION TO VISIBILITY SUCH
A
SK
NAGE SHALL BE LOCATED WITHIN A TRIANGULAR AREA 50 FT BACK
F
OM
HE INTERSECTING RIGHT-OF-WAY LINE (OR INTERSECTING TANGENT
LI
ES
OR RADIAL DEDICATIONS) AT THE INTERSECTIONS. GROUND -MOUNTED
SIGN
N T TO EXCEED EIGHT (8) FEET IN HEIGHT AND MAXIMUM AREA OF
O
E-H
NDRED (100) SQUARE FEET.
LANDSCAPING REQUIREMENTS NOTE:
DEVELOPERS MET ON -SITE WITH TRACY SPILLMAN TO DISCUSS
LANDSCAPE REQUIREMENTS. A COMPLETED LANDSCAPE PLAN
INDICATING EXISTING AND PROPOSED PLANT MATERIALS WILL
BE SUBMITTED FOR APPROVAL PRIOR TO ISSUANCE OF A
BUILDING PERMIT.
V)
+-
N
c�
Y
+�
Q
V)�o
0
00
�m
006
o m
+
�o
-J
�
L
v �
U
c:
o
V)
�0
M
r4
� O F q �Typ� , 1 ••••.......•. ARK
_ PHILLIP LEWIS •��� s, R G ;
(Wj I ENGINEERING, INC.
No. 566 r 4 E G
PROJECT NUMBER:
SHEET ISSUE DATE:
8-25-2020
PAGE TITLE:
SITE
PLAN
SHEET NUMBER:
C1.1