Loading...
HomeMy WebLinkAboutSite Plan Revised 082520"oo, 41 / �' \ •� \\------ ----- ♦* ♦i i 3 ' �.� I I I I i I i I I I % EXISTING BUILDING I EASEMENT/BUILDING LINE 00 I I � I I J I I I w i -I % NEW DUMPSTER PAD Z I I I LOCATION FOR CARWASH I I � I NEW LIGHT POLE w (+l-) 99.80' - — - I (+/-) 463.31' b 60.1T i I POLELIGH36.33' / lg r ER 10.6' EQUIP. % ROOM I I 20 R� O o 0 193.95' I i o s` .♦ 125 FT BELT TUNNEL I 20.00' / �13 I U) NEW 8'-0" TALL x 12'-0" WIDE NEW LIGHT POLE % • / % I ♦ 125 FT BELT TUNNEL ♦ I i GROUND -MOUNTED SIGN 24.32' 3� �6Q� N I NEW DUMPSTER PAD / j l f I OO 16.00, 18.00' LOCATION FOR LUBE / / r 24.00' �� IE 31 I I CENTER / / / f o, } - ILO DETAIL r rn I AREA I ? I ! W Q ♦ I ♦ ♦ � o o Y I L)/ W 20.19' Q I w j I / / I o o U �pO Ln I o0 / z _ o- EXISTING BUILDING 0 / I CUSTOMER Q _ WAITING TO BE REMODELED 0 OFFIC / ETC. I I z / a ilk NFW�Ug�C R78.10' * t t 18.00' 2�54 I R800• Iw N / Opg SQ. FT TFR ■ I � R 2.0p• I 9.00' F I 'A2 18.08I bA.92' 1 _ Q- // 45.44' 66.86, 25 INDOOR VACUUMS ♦ M I 00' II r- 4 PARKINGIcb, / / cfl Q ♦ ('n - / NEW L,GHT CZ I POLE V&/�p0 i I - -- -- ----- 22.00' 000 FM= 1 EXISTING 6" DIP _ I- FM— — 75.40' I I II I LOT 1 B EXISTING FIRE NEW LIGHT II I li EXISTING DRIVE M(+/-) 2.20 ACRES HYDRANT — — - _ - � / NEW LIGHT POLE POLE I I TO REMAIN • — • — - LOT 1 C (+/-)0.83ACRES II i► I t I_._._._._ i I EXISTING MANHOLE u� - — - _ / NEW PROPOSED II L_____I _,_._--•— - (+I-)397.84' LOT LINES— / APPROX. LOCATION OF I _ • — • — ' - - I EXISTING SIGNAGE TO ' REMAIN WELLINGTON HILLS RD (90' RIW) I 2 I ' SITE PLAN 30 15 0 30 60FT SCALE: 1 "=30'-0" SCALE: 1" = 30'-0" W W a J z W U GENERAL CONSTRUCTION NOTES z — A. THE CONTRACTOR WILL BE HELD SOLELY RESPONSIBLE FOR DAMAGES OCCURRING TO ANY PROPERTY DURING THE CONSTRUCTION OF THIS ( j PROJECT. SAID CONTRACTOR SHALL TAKE ALL NECESSARY z PRECAUTIONS TO PREVENT PROPERTY DAMAGE. R w B. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, w THE CONTRACTOR WILL SOLELY AND COMPLETELY BE RESPONSIBLE FOR z CONDITIONS OF THE JOB SITE, INCLUDING SAFETY WORK. THIS REQUIREMENT L7 WILL APPLY CONTINUOUSLY AND WILL NOT BE LIMITED TO NORMAL WORKING z HOURS. Lu V) HE DUTY OF THE CITY OF LITTLE ROCK & CENTRAL ARKANSAS WATER O CONDUCT CONSTRUCTION INSPECTIONER REVIEWS OF THE w ONTRACTOR'S PERFORMANCE IS NOT AN INSPECTION OR REVIEW OF THE DEQUACY OF THE CONTRACTOR'S SAFETY MEASURES IN, ON, OR NEAR THE ONSTRUCTION SITE. J C. A L WATER AND SEWER IMPROVEMENTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE LATEST REVISION TO CENTRAL ARKANSAS WATER'S & L TTLE ROCK WATER RECLAMATION AUTHORITY'S STANDARD SPECIFICATIONS. D. T E CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION A D/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS B SED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE P SSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT T BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST C ILL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE A Y EXCAVATION TO REQUEST EXACT FIELD LOCATION OF ALL UTILITIES. IT HALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL E ISTING UTILITIES WHICH CONFLICT WITH PROPOSED IMPROVEMENTS REVISION: S OWN ON THE PLAN. E. CONTRACTOR IS TO REMOVE AND DISPOSE OF ALL DEBRIS, RUBBISH, AND OT ER MATERIALS RESULTING FROM PREVIOUS AND CURRENT DEMOLITION OP RATIONS. DISPOSAL WILL BE IN ACCORDANCE WITH ALL LOCAL, STATE AN /OR FEDERAL REGULATIONS GOVERNING SUCH OPERATIONS. PRI R TO INSTALLATION OF ANY UTILITIES, THE CONTRACTOR IS TO EX AVATE, VERIFY AND CALCULATE ALL CROSSINGS AND INFORM ANY AND AL UTILITIES OF ANY CONFLICTS PRIOR TO CONSTRUCTION. CO STRUCTION SHALL NOT START ON ANY WATER UTILITY TIE-INS UNTIL AP ROVAL IS GIVEN BY CENTRAL ARKANSAS WATER. SAID CONTRACTOR SH LL NOT OPERATE ANY VALVE, HYDRANT, OR WATER UTILITY APPURTENANC NO SHALL HE ATTACH TO OR TAP ANY WATER UTILITY MAIN WITHOUT APP OVAL. THE CONTRACTOR SHALL BEAR THE COST AND CONSEQUENCE OF ANYI DISRUPTION OF UTILITY OPERATION CAUSED BY CONSTRUCTION. H. FIBEOPTIC CABLE ON AND/OR ADJACENT TO THIS SITE WERE NOT LOCATED Y E SURVEY AND ARE NOT SHOWN. IT IS THE RESPONSIBILITY OF THE ON RACTOR TO LOCATE ANY FIBER OPTIC CABLES ASSOCIATED WITH THIS ITE AND TAKE ALL NECESSARY AND REQUIRED PRECAUTIONS TO PROTECT NY XISTING FIBER OPTIC CABLES. CONTRACTORS SHALL COORDINATE ALL FF RTS WITH OWNER OF FIBER OPTIC CABLES OR THEIR DESIGNATED EP ESENTATIVE. J. T E ONTRACTOR IS RESPONSIBLE FOR CONTACTING "ONECALL" SERVICE T M RK ALL UTILITIES PRIOR TO ANY DEMOLITION, EARTHWORK, OR UTILITY ORK ON THIS SITE. K. R PAIR OR REPLACE ANY CURB, GUTTER, SIDEWALK AND ACCESS RAMPS T AT RE DAMAGED AND NOT IN COMPLIANCE WITH ADA RECOMMENDATIONS I TH PUBLIC RIGHT-OF-WAY PRIOR TO OCCUPANCY. L. D MA E TO PUBLIC AND PRIVATE PROPERTY DUE TO HAULING OPERATIONS O OP RATION OF CONSTRUCTION RELATED EQUIPMENT FROM A NEARBY C NS RUCTION SITE SHALL BE REPAIRED BY THE RESPONSIBLE PARTY P IOR O ISUANCE OF A CERTIFICATE OF OCCUPANCY. M. I AC ORDANCE WITH SECTION 32-9, NO OBSTRUCTION TO VISIBILITY SUCH A SK NAGE SHALL BE LOCATED WITHIN A TRIANGULAR AREA 50 FT BACK F OM HE INTERSECTING RIGHT-OF-WAY LINE (OR INTERSECTING TANGENT LI ES OR RADIAL DEDICATIONS) AT THE INTERSECTIONS. GROUND -MOUNTED SIGN N T TO EXCEED EIGHT (8) FEET IN HEIGHT AND MAXIMUM AREA OF O E-H NDRED (100) SQUARE FEET. LANDSCAPING REQUIREMENTS NOTE: DEVELOPERS MET ON -SITE WITH TRACY SPILLMAN TO DISCUSS LANDSCAPE REQUIREMENTS. A COMPLETED LANDSCAPE PLAN INDICATING EXISTING AND PROPOSED PLANT MATERIALS WILL BE SUBMITTED FOR APPROVAL PRIOR TO ISSUANCE OF A BUILDING PERMIT. V) +- N c� Y +� Q V)�o 0 00 �m 006 o m + �o -J � L v � U c: o V) �0 M r4 � O F q �Typ� , 1 ••••.......•. ARK _ PHILLIP LEWIS •��� s, R G ; (Wj I ENGINEERING, INC. No. 566 r 4 E G PROJECT NUMBER: SHEET ISSUE DATE: 8-25-2020 PAGE TITLE: SITE PLAN SHEET NUMBER: C1.1