Loading...
HomeMy WebLinkAboutPW Agenda Comments Public Works Review Comments Planning Commission Board of Adjustment Agenda Date: 6-4-20 Z File Number S-1876 Arkansas Urology Ambulatory Surgery Center 1300 Centerview Drive 0 Access easement width??? Z File Number Z-9514 Friendship Aspire Academy Charter School CUP Vernon Estates Dr East of Chicot Rd 1 Existing public right-of-way within the site connected to Vernon Estates Dr. and Acorn Place which will not be ussed in the future should be abandoned by the CLR Board of Directors. 2 Turnarounds in conformance with the Fire Code should be provided at the east end of Vernon Estates Dr., Acorn Place,and other platted public streets for vehicle manuevering. The 10 ft radius and 12 ft width of the proposed turnaround off Vernon Estates Drive will not pass a fire truck.The turnaround should be at least 20 ftr wide. A public access easement should be recorded for the 3 With site development, provide design of street conforming to the Master Street Plan. Provide full street improvements to Acorn Place and other platted public streets within the planned development. Due to the existing conditions of the streets and drainage improvements, an evaluation and determination will be required of the existing street(s) and drainage improvements to determine conformance with CLR design standards. 4 Repair or replace any curb, gutter, sidewalk and access ramps that are damaged and not in compliance with ADA recommendations in the public right-of-way prior to occupancy. 5 The existing sidewalk on Vernon Estates Drive should be extended in conformance with ADA standards to the school entrance doorway. 6 Plans of all work in right-of-way shall be submitted for approval prior to start of work. Obtain barricade permit prior to doing any work in the right-of-way from Traffic Engineering at (501) 379- 1805 (Travis Herbner). 7 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is a variance being requested to advance clear and grade beyond the areas proposed to be developed with the 8 Per Sec. 29-102 an evaluation should be conducted on the basis of existing downstream development and any analysis of stormwater runoff with and without the proposed development. If the proposed development will cause or increase downstream flooding conditions, provisions to minimize such flooding conditions should be included in the design of the storm management improvements. Such provisions may include downstream improvements and/or detention of stormwater runoff and its regulated discharge to the downstream storm drainage system. 9 Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer, property owners association, and/or Friday, May 8, 2020 Page 1 of 2 10 Will the school and supporting infrastructure be built in one phase? 11 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 12 Street Improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. 13 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic Engr 379-1813 for more info. 14 Obtain permits prior to doing any street cuts or curb cuts. Obtain barricade permit prior to doing any work in the right-of-way. Contact Traffic Engineering at (501) 379-1805 (Travis Herbner) for more information. 15 Hauling of fill material on or off site over municipal streets and roads requires approval prior to a grading permit being issued. Contact Public Works Traffic Engineering at 621 S. Broadway, (501) 379-1805 (Travis Herbner) for more information. 16 Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e). 17 With development, the existing street and drainage improvements within public right-of-way fronting and accessing undeveloped tracts is required to be evaluated to determine conformance with CLR street and drainage standards. If found to be substandard, with future development street improvements to CLR standards will be required to be constructed. 18 Erosion controls must be installed to reduce discharge of polluted stormwater. 19 The traffic study has been received and is being evaluated by Traffic Engineering. 20 Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. 21 Are the proposed dimensions of the tracts proposed to be modified? 22 The USPS should be contacted to determine if mail cluster box will be required to be provided for the proposed residences. If required show the proposed location(s) of the USPS cluster box units in conformance with USPS and City of Little Rock policy design standards. Z File Number Z-9517 Phillips Duplex Housing CUP SWC Potter St. & 30th St. 1 Potter St. is classified on the Master Street Plan as a residential street. A dedication of right-of-way of 5 ft in width will be required. 2 A 20 feet radial dedication of right-of-way is required at the intersection of Potter St. and 30th St. 3 If access to the property is taken from Potter Street, the existing pipe adjacent to 30th St. should be removed and the ditch restored. Friday, May 8, 2020 Page 2 of 2