Loading...
HomeMy WebLinkAboutPC Action Letter 070120 Approved with Conditions0*-'7; Department of Planning and Development 723 West Markham Street Little Rock, Arkansas 72201-1334 Phone: (501)371-4790 Fax: (501)371-4546 July 1, 2020 Stanley Phillips 6204 Sandy Lane Little Rock, AR 72204 Re: File No. Z-9517 Planning Development Building Codes Phillips Duplexes — Conditional Use Permit; located southwest corridor of West 30th Street and Potter Street Dear Mr. Phillips: This is to advise you that in connection with your request concerning the above referenced file number the following action was taken by the Planning Commission at its meeting on June 25, 2020: X Approved with conditions. Recommended approval with conditions. Recommended approval as submitted. Denied your request as submitted. Deferred to the Other: Meeting. If you have any questions please do not hesitate to contact me at 371-4792. Respectfully, V VT� Monte Moore Development Administrator MM:aa June 25, 2020 ITEM NO.: 3 FILE NO.: Z-9517 NAME: Phillips Duplexes — Conditional Use Permit LOCATION: Southwest corner of West 30th Street and Potter Street OWNER/APPLICANT: Savage Properties/Stanley Phillips PROPOSAL: A conditional use permit is requested to allow for the construction of two (2) duplex structures on two (2) R-3 zoned platted lots located at the southwest corner of West 30th Street and Potter Street. K COMPATIBILITY WITH NEIGHBORHOOD: The property is located in an area predominantly zoned R-3 and R-2. A number of single family residences and vacant lots are located in the area. A few duplex structures are also located in the general area. The applicant proposes to construct two (2) duplex structures on two (2) platted lots. The proposed use is compatible with uses in the area. Notice of public hearing was sent to the John Barrow Neighborhood Association. ON SITE DRIVES AND PARKING: The applicant proposes to construct one (1) 20 foot wide driveway from West 30th Street, near the northwest corner of the property. There will be a total of eight (8) parking spaces, four (4) for each duplex structure. Section 36-502 (b) (1) (c) of the City's Zoning Ordinance requires a minimum of three (3) parking spaces for each duplex structure (1.5 spaces per unit). The applicant is providing four (4) paved parking spaces for each duplex structure. 3. SCREENING AND BUFFERS: 1. Any new site development must comply with the City's minimal landscape and buffer ordinance requirements. 2. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property, or the right-of-way of any street. This strip shall be at least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting strip. June 25, 2020 SUBDIVISION ITEM NO.: 3 Cont. FILE NO.: Z-9517 3. Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-way. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet. 4. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 4. ENGINEER#NG COMMENTS: 1. Potter Street is classified on the Master Street Plan as a residential street. A dedication of right-of-way of 5 ft. in width will be required. 2. A 20 feet radial dedication of right-of-way is required at the intersection of Potter Street and 30th Street. 3. If access to the property is taken from Potter Street, the existing pipe adjacent to 30th Street should be removed and the ditch restored. 5. UTILITIES/FIRE DEPARTMENT/BUILDING CODES: Little Rock Water Reclamation Authority: Separate sewer service lines required for each lot. Entergy: No comments received. Centerpoint Energy: No comments received. AT&T: No comments received. Central Arkansas Water: No comments received. Fire Department: Full Plan Review Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is 2 June 25, 2020 SUBDIVISION ITEM NO.: 3 Cont. FILE NO_: Z-9517 located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loading Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Gates Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 3 June 25, 2020 SUBDIVISION ITEM NO.: 3 (Cont.) FILE NO.: Z-9517 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal's Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. Building Codes: No Comments. 6. TRANSPORTATION/PLANNING: County Plannin : No Comments. Rock Region METRO: No comments received. Planning Division: No Comments. STAFF ANALYSIS: The applicant is requesting approval of a conditional use permit to allow for the construction of two (2) duplex structures on two (2) platted lots located at the southwest corner of West 30th and Potter Streets. The lots are 48 feet wide and approximately 138 feet deep. The lots are currently undeveloped. An undeveloped alley right-of-way runs along the rear (west) property line. The applicant proposes to construct a 2,348 square foot duplex structure on each of the two (2) lots. The duplex structures will be two (2) stories in height with hip roofs and asphalt shingles. The duplex structures will be constructed on concrete slabs, and be wood frame construction with vinyl siding and vinyl clad windows. 4 June 25, 2020 SUBDIVISION ITEM NO.: 3 Cont.) FILE NO.: Z-9517 Each duplex structure will be located 25 feet back from the front (east) property lines and six (6) feet back from the north side property line and south side property line of the overall property. Each duplex structure will be located approximately 6.5 feet back from the center, dividing side property line. The structures will be located over 60 feet back from the rear property lines. Eight (8) paved parking spaces (four (4) per unit) will be provided for each duplex structure. A new paved driveway from West 30' Street will serve the duplex structures. To staff's knowledge, there are no outstanding issues associated with this application. Staff believes the proposed two (2) duplex structures located on two (2) platted lots located at the southwest corner of West 30th and Potter Streets is an appropriate use for this property. The two (2) duplex structures will only be a minor increase in the original platted density for this property. The proposed duplex structures will not be out of character with the general area. Other duplex structures are located throughout the John Barrow Neighborhood. Staff believes the proposed duplexes will have no adverse impact on the subdivision or surrounding uses. STAFF RECOMMENDATION: Staff recommends approval of the requested CUP, subject to compliance with the comments and conditions outlined in Sections 3, 4 and 5 of the agenda staff report. PLANNING COMMISSION ACTION- (JUNE 25, 2020) Stanley Phillips was present, representing the application. There were two (2) supporters and one (1) objector present. Staff presented the application with a recommendation of approval. Akaya Kitchen addressed the Commission in opposition of the application. She expressed concerns related to the increase of crime associated with low-income families. She briefly explained a rise in criminal activity directly related to occupants of duplex dwellings within the neighborhood. Stanley Phillips addressed the Commission in support of the application. He explained that the proposed project will add value to the community due to the quality and design of the properties. To address the opposing points, he briefly explained the screening processes used by management companies to screen potential applications such as background and credit history verifications. 5 June 25, 2020 SUBDIVISION ITEM NO.: 3 (Cont.) _ FILE NO_- Z-9517 Denise Franklin, a resident and multi -property owner in the John Barrow Community, addressed the Commission in support of the application. She explained that the proposed project will promote continued improvement and growth within the community. Krystal Alexander, a 9-year resident of Phillips' property, addressed the Commission in support of the proposed property. As a single mother of three (3) children, she expressed gratitude for the opportunity to provide a better quality of life within a community she deems as a safe. There was a motion to approve the application as recommended by the staff, including all staff comments and conditions. The motion was seconded. The vote was 11 ayes, 0 nays, and 0 absent. The application was approved. L