HomeMy WebLinkAboutReponses to Planning Staff Comments 11132020Planning Staff Comments
Item Number: 6
File Number: Z-4517-A
Title: Masoud Private Club — PCD - 4721 Baseline Road
1. Provide area of entire building.
2. Provide area of building to be devoted to the proposed restaurant use.
3. Provide total number of parking spaces on the site.
4. Will there be a dumpster located on the site? If so, show on site plan with required screening.
5. Provide site lighting details.
6. Provide details on ground sign (height and area). Will any additional signage conform to C-3
standards?
Masoud Short -Form PCD Z-4517-A
4721 Baseline Road
Applicant Responses to Planning Staff Comments
1. Area of entire building is 200' width by 50' depth = 10,000 square feet
2. Area of building for restaurant use is 3,000 square feet.
3. Total parking spaces in front of building is 40. There is a large vacant concrete slab behind
building (south side) that can be used for additional parking if necessary.
4. Yes, there will be a dumpster onsite. Will comply with screening.
5. Site lighting details will be provided.
6. Multi -panel ground mounted tenant sign about 20 feet high and 8 feet wide stands at entrance
to property from Baseline Road. Will comply with C-3 standards for additional signage.
NOTE: Calculations are approximate.
To: Monte Moore Date: October 28, 2020
From: Captain Tony Rhodes, Captain John Hogue and Fire Marshal Derek Ingram
Comment for the following Locations:
S-1882
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.
1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in'
grade except as approved by the fire chief. If the grade exceeds 10 percent,
approval will be denied and the applicant must submit request to be reviewed
by Fire Chief for Approval!,
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D302.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable of supporting the
imposed load of fire apparatus weighing at least 75,000 pounds.
One- or Two -Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family
dwelling residential developments. Developments of one- or two-family dwellings where the number of
dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access
roads, and shall meet the requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling units on a single public or private fire apparatus
access road and al dwelling units are equipped throughout with an approved automatic
sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the
Arkansas Fire Code, access from two directions shall not be required.
The number of dwelling units on a single fire apparatus access road shall not be increased
unless fire apparatus access roads will connect with future development, as determined by
the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101—
C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire
Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and
Distribution of Fire Hydrants as per Table C105.1.
Z-4517-A
Full Plan Review pj�L-L (:�:rlhV-Y
Z-6274-D
Full Plan Review
Z-7091-A
No comments
Z-9543
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D303.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol.
1 section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in
grade except as approved by the fire chief. If the grade exceeds 10 percent,
approval will be denied and the applicant must submit request to be reviewed
by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of an approved fire apparatus
Little Rock Water Reclamation Authority Comments
Project Number A-338
Project Name Project Type
Hastings Annexation Annexation
Project Number S-1313-SS
Project Name
Project Type
Woodlands Edge Blocks 32
Time extension for Prelim Plat
and 33
Project Number Z-1882
Project Name
Project Type
The Grove at Old Oak
Preliminary Plat
Project Number Z-2502-F
Project Name
New Africa Subdivision
Project Number Z-4517-A
Project Name
Masoud Private Club
Project Number Z-6274-D
Project Name
Ahern Rentals
Project Number Z-9543
Project Type
Site Plan/reliminary Plat
Comment Made
Sewer main extension required with easements if new
sewer service is required for this project.
Comment Made
Sewer main extension required with easements if new
sewer service is required for this project.
Comment Made
Sewer main extension required with easements if new
sewer service is required for this project.
Comment Made
Sewer main extension required with easements if new
sewer service is required for this project.
Project Type Comment Made WI 1 7 CDApLY
Conditional Use Sewer Available to this Site. FOG Analysis required if
food prep on site.
Project Type
Revised Planned Development:
Commercial
Project Name
Project. 'Type
Friendship Aspire Academy
Conditional Use
Project Number 1-9544
Project Nama
Project Type
Gray Duplexes
Planned Development: Residential
Comment Made
Sewer Available to this Site.
Comment Made
Sewer Available to this Site. FOG Analysis required if
food prep on site.
Coinrnent Made
Sewer Available to this Site. Separate service line to
the main is required for each separate structure (2
dwelling units per structure).
Friday, October 30, 2020 Page 1 of 2