HomeMy WebLinkAboutPlanning Staff Comments 072320Planning Commission Agenda Date: 8-27-20
Z File Number Z-7500-G
Hamilton Apartments PD-R 14524 Cantrell Road
PLANNING REVIEW COMMENTS
1) Building height = 50’-60’ depending on which side of the building.
2) Please see exhibit “the Hamilton Elevation” for building exterior appearance.
Material will include hardie board siding and precast concrete.
3) There will be a masonry screened dumpster on site. See site plan.
4) Description of site lighting: site lighting will be low level, shielded and directed away
from adjacent property.
5) At this time we will have a monument sign at the entrance of the apartments.
6) Fence- 6’ height decorative metal, see site plan for fence location.
7) Each entrance will have a access easement.
8) See site plan for floodway and floodplain location.
9) We do not have any garage and canopy details at this time. We will construct in
accordance with the city code and will have a similar architectural look to the
apartment building.
PUBLIC WORKS REVIEW COMMENTS
1) Repair or replace any curb and gutter or sidewalk that is damaged in the public
right-of-way prior to occupancy.
Will comply.
2) A grading permit in accordance with section 29-186 (c) & (d) will be required prior to
any land clearing or grading activities at the site. Other than residential subdivisions,
site grading and drainage plans must be submitted and approved prior to the start of
construction. Is the project proposed to be constructed in 1 phase?
Will comply, 1 phase of construction only.
3) Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e).
See sketch grading plan.
4) Storm water detention ordinance applies to this property. Maintenance of the
detention pond and all private drainage improvements is the responsibility of the
developer, property owners association, and/or owner.
Will comply
5) If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the
Arkansas Department of Environmental Quality prior to the start of construction.
An ADEQ permit will be obtained prior to construction.
6) A special Grading Permit for Flood Hazard Areas will be required per Sec. 8-283 prior
to construction.
Will comply.
7) The minimum Finish Floor elevation of at least 1 ft or more above the base flood
elevation is required to be shown on plat and grading plans.
We will have a FFE = 302 to 304.5. The sketch grading plan has it at 304.5.
8) In accordance with Section 31-176, floodway areas must be shown as floodway
easements or be dedicated to the public. In addition, a 25 foot wide drainage and
access easement is required adjacent to the floodway boundary. Show on site plan.
See attached site plan for easements.
9) On the site plan, show the existing and proposed floodway lines. With portions of the
proposed development within the floodway, a Conditional Letter of Map Revision
(CLOMR) must be approved prior to issuance of a grading permit. A Letter of Map
Revision (LOMR) must be approved to revise the floodway prior to issuance of the
building permit even if the LOMR is being prepared by another party.
Will comply.
10) The existing driveway creates left turn conflicts with Jerry Drive. Due to the proposed
traffic volumes, the existing driveway should be relocated to align with Jerry Drive to
alleviate the unsafe driving condition. Show Jerry Drive on the south side of Cantrell
Road on the site plan.
The secondary entrance at this location will only be used as an emergency and
service entrance.
11) Will the east driveway serve as an emergency access only or will it provide a second
access for apartment occupants and staff?
12) Obtain approval from the property owner for the east driveway thru the adjacent
property. Show on plan a shared access easement to Cantrell Road.
The developer is the owner of Pinnacle Station. We will file an easement as required.
13) Per Chapter 36, no parking is allowed within the floodway.
All parking has been removed from the floodway.
14) The owner and/or manager of each multi-family residence of 100 or more dwelling
units shall provide recycling and encourage participation by the tenants, renters, or
owners of each unit. Contact Melinda Glasgow at 371-4646 for more information.
Recycling will be provided.
15) Submit a Traffic Impact Study for the proposed project due to the amount of vehicular
traffic on Hwy 10 and the amount of left turn movements. Study should address trip
generation and trip distribution for the development and also should take into account
existing and projected traffic.
Ernie Peters, PE has performed our traffic study. Please see attached traffic study.
16) Access easements should be obtained for access to the property through other
private properties. The west access at the Taylor Loop Road intersection is proposed
to be taken thru an existing parking lot or service easement not constructed to a
private commercial street standard. The existing service easement has 9 uncontrolled
curb cuts, backout parking spaces, and no pedestrian access to the apartments and
existing development.
The developer is the owner of Pinnacle Creek. We will file an easement as required.
The road will be constructed to commercial street standards. Please see exhibit “the
Hamilton Redeveloped Entrance” for improvements to correct uncontrolled curb cuts,
backout parking spaces, and no pedestrian access to the apartments.
17) Obtain permits for improvements within State Highway right-of-way from AHTD,
District VI.
A permit will be obtained if necessary.
18) Alteration of the water course will require approval from the Little Rock District of the
US Army Corps of Engineers prior to start of work.
A permit will be obtained if necessary.
19) A right turn lane should be constructed on Cantrell Road for the east driveway and the
taper extended to the adjacent property's driveway if access other than emergency
only access to the apartments is planned at the east driveway. The right turn lane
should consist of 100 ft taper.
The secondary entrance at this location will only be used as an emergency and
service entrance.
20) The existing service easement cannot be used for vehicle backing. All parking
spaces backing into the service easement must be removed or a variance requested.
The easements should be constructed to commercial street standard with sidewalks.
Please see exhibit “the Hamilton Redeveloped Entrance” for improvements.
21) A minimum undisturbed buffer strip 25 ft wide except for reasonable access shall be
provided along each side of streams having a 10 yr storm >150 cfs. The undisturbed
strip should be measured from the top of the bank.
BUFFER AND LANDSCAPE REQUIREMENT COMMENTS
1. Site plan must comply with the City’s minimal landscape and buffer ordinance
requirements.
Will comply.
2. A land use buffer six (6) percent of the average width / depth of the lot will be
required when an adjacent property has a dissimilar use of a more restrictive nature.
As a component of all land use buffer requirements, opaque screening, whether a
fence or other device, a minimum of six (6) feet in height shall be required upon the
property line side of the buffer. Easements cannot count toward fulfilling this
requirement. The plantings, existing and purposed, shall be provided within the
landscape ordinance of the city, section 15-81.
The average width of the lot is approximately 800 feet. A minimum forty-eight
(48) foot buffer is required adjacent to the R-2 zoned property to the west.
Screening requirements will need to be met adjacent to the north, east, and
west R-2 zoned properties.
All screening requirements will be met. All buffer requirements are greater than 48’.
The west buffer appears to be 41’, but when you average the area including the
landscape islands, an equivalent 48’ buffer is met.
3. A perimeter planting strip is required along any side of a vehicular use area that
abuts adjoining property or the right-of-way of any street, highway or freeway. This
strip shall be at least nine (9) feet wide. Provide trees with an average linear spacing
of not less than thirty (30) feet within the perimeter planting strip. Provide three (3)
shrubs or vines for every thirty (30) linear feet of perimeter planting strip.
Will comply.
4. Landscape areas shall be provided between the vehicular use area used for public
parking and the general vicinity of the building, excluding truck loading or service
areas not open to public parking. These areas shall be equal to an equivalent planter
strip three (3) feet wide along the vehicular use area.
Will comply.
5. Eight percent (8%) of the vehicular use area must be designated for green space;
this green space needs to be evenly distributed throughout the parking area(s). For
developments with more than one hundred fifty (150) parking spaces the minimum
size of an interior landscape area shall be three hundred (300) square feet. Interior
islands must be a minimum of seven and one half (7 1/2) feet in width. Trees shall be
included in the interior landscape areas at the rate of one (1) tree for e very twelve
(12) parking spaces.
Will comply
6. A landscape irrigation system shall be required for developments of one (1) acre or
larger.
Will comply
7. The City Beautiful Commission recommends preserving as many existing trees as
feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can
be given when preserving trees of six (6) inch caliper or larger.
We want to save as many trees as possible.
We will comply with all fire marshal comments.
We will comply with building code comments.
We will comply with LRWRA comments and provide easements for any relocated mains.