Loading...
HomeMy WebLinkAboutZ-9615 Response to Comments 092221City of Little Rock Planning and Development Planning Commission Hearing/October 14, 2021 Applicant Comments for Proposed Development Applicant Responses are due no later than Wednesday, Se teniber $ 2021. Please submit revised site plans, if applicable, along with any written responses. All documents should be submitted to this email address for review. RE: Z-9615 (Pit Stop BBQ Private Club — CUP, 5506 Baseline Road) Deveio rnent Comments 1. Provide cover letter explaining proposal. 2. Provide proposed hours of operation. 3. Provide information on existing use. 4. If there are to be changes to the building or parking, note in cover letter. 5. Provide parking plan on survey. Civil Engineering Comments 1. Baseline Rd is classified on the Master Street Plan as a principal arterial with a special design standard. Dedication of right-of-way to 45 feet from centerline will be required. \U\ Li. (aM �.'f 2. With future development or expansion of the site only one driveway will be permitted as found in Sec. 31-210 of city code. \, k 0- U Landscape Comments 1. Any new site development must comply with the City's minimal landscape and buffer ordinance requirements. .\,Q �k U C() rk PON 2. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. Vj, LL CDO�L`4 LR Fire Department Comments Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. goytD Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. If the grade exceeds 10 percent, approval will be denied and the applicant must submit request to be reviewed by Fire Chief for Approval. Loading Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. 130V�b Commercial and Industrial Developments — 2 means of access. - Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 �13c) Wb Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30 I feet or three stories in height shall have at least two means of fire apparatus access for each structure. Ni 0 UD Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross building area of more than 62,000 square feet shall be provide with two separate and approved fire apparatus access roads. Exception: Projects having a gross building area of up to 124,000 square feet that have a single approved Fire apparatus access road when all building are equipped throughout with approved automatic sprinkler systems. �i OVZ 0 D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses. a Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N Ingram 501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1. LR Reclamation Authority Comments 1. Sewer available. FOG Analysis required.