HomeMy WebLinkAboutZ-8213-A BOA Staff ReportOCTOBER 15, 2020
ITEM NO. 1 Z-8213-A
1
File No.: Z-8213-A
Owner/Applicant: John Kirk and Charlene Coker-Kirk
Address: 5209 Kavanaugh Boulevard
Description: Lot 12, Block 1, McGehee Addition to the City of Little Rock,
Pulaski County, Arkansas.
Zoned: R-2
Variance Requested: A variance is requested from the area provisions of Section
36-156(a)(2)(c) to allow an accessory building to occupy more
than 30 percent of the required rear yard area in an R-2
District.
A variance is requested from the area provisions of Section
36-156(a)(2)(f) to allow an accessory building with a reduced
setback from a side yard property line.
Justification: Presented in letter dated August 28, 2020 (attached.)
Present Use: Single-Family Residential
Proposed Use: Single-Family Residential
STAFF REPORT
A. Planning and Development Civil Engineering:
No Comment.
B. Landscape:
In October 2020 the City adopted the “Heights Landscape Design Overlay District,”
requiring installation of one tree per 40 linear feet of street frontage within the
Heights District Boundary, applicable to [among other types] residential
construction in excess of 600 square feet.
C. Building Codes:
The required fire separation distance (building to property line) prescribed by the
building code terminates at five feet. Buildings are allowed to be closer than
five feet if they have properly constructed fire walls which provide the requisite one
hour fire resistance rating. When buildings are five feet or more from the property
line, the requirement no longer applies to the wall itself, only the projections such
as eaves or overhangs.
Openings such as doors and windows are limited when the exterior wall is three
feet from the property line and are prohibited when the exterior wall is less than
three feet from the line. There is no restriction on openings when the exterior wall
is more than three feet from the property line.
Contact the City of Little Rock Building Codes (501)371-4832 for additional details.
OCTOBER 15, 2020
ITEM NO. 1 (CON’T.) Z-8213-A
2
D. Staff Analysis:
Note - This item previously appeared before the Board of Adjustment as “Z-8213”
on May 21, 2007. That application proposed a two-car carport to cover the existing
concrete pad constructed unknown years prior, situated approximately 1’ from the
west property line. Z-8213 was unanimously approved by the Board.
In April 2019 the carport was destroyed by a fallen tree during a storm. Section 36-
154(b) states, “In the event that any structure that is devoted in whole or in part to a
nonconforming use is destroyed by fire, explosion or other casualty, or the public
enemy, to the extent of more than fifty (50) percent of the current replacement value
immediately prior to such damage, such structure shall not be restored unless such
structure and use thereof shall thereafter conform to all regulations of the zoning
district in which such structure and use are located.”
As a result of the above-cited requirement, approval of the subject variance
application, known as “Z-8213-A,” is necessary prior to issuance of a building permit.
********************
The R-2 zoned property is located at 5209 Kavanaugh Blvd. on the south side of
Kavanaugh Blvd., occupied only by the existing approximately 1,950 square-foot
two-story wood frame single family residence. An original one-car wide driveway
exists at the northwest portion of the property and extends from Kavanaugh
Boulevard into the rear yard area. A paved alley right-of-way is located along the
rear (south) property line.
The applicant proposes to construct a 524.3 s.f. one-story wood frame garage upon
the existing 22.6’ x 23.2’ former carport foundation. This proposed two-car garage
would generally match the principal residence, materially. The existing foundation,
thus the proposed garage, is situated approximately 1.9 feet from the south (alley)
property line, and approximately 1 foot from the west property line.
Section 36-156(a)(2)(c) limits rear yard coverage by an accessory building to 30
percent. The applicant requests a variance to allow the one-story accessory building
to cover approximately 41 percent of the defined rear yard.
Section 36-156(a)(2)(f) requires a minimum of 3 feet of separation between an
accessory structure and an adjacent property line. (0 feet separation is required
between an accessory building and adjacent alley.) The applicant requests a
variance to allow a minimum of 0.9 feet between the existing slab/proposed structure
and west property line.
As of this writing, the Planning and Development Office has received no objections
to the subject proposal. The applicant has indicated the neighbor to the west is in
support of the application.
OCTOBER 15, 2020
ITEM NO. 1 (CON’T.) Z-8213-A
3
The proposed detached garage is compatible with and generally comparable in
scale to most rear-yard alleyway garages in the general vicinity. Staff views the
request as reasonable and supports the above-described variance requests.
E. Staff Recommendation:
Staff recommends approval of the requested increase in accessory building rear
yard coverage to a maximum of 41%, and a reduction in the adjacent side yard
setback to a minimum of 0.9 feet, subject to the following conditions:
1. Install roof guttering to prevent water run-off from the proposed garage onto the
adjacent property to the west.
2. Install trees, if deemed applicable at the time of building permitting, in
accordance with Heights Landscape Design Overlay District requirements.