Loading...
HomeMy WebLinkAbout030121_CoA Application_314 E 6thPROOF OF OWNERSHIP OF PROJECT PROPERTY REQUIRED AND ADDITIONAL SUBMITTAL DRAWINGS A1.1 - SITE PLAN + FLOOR PLAN A1.2 - ROOF PLAN A2.1 - ELEVATIONS A3.1 - STREET LEVEL VIEWS A2 4 A2 A2 3 1 A22 (PRIVATE PARKING) NEW WINDOWS IN ENLARGED AC UNIT OPENING EXISTING 1-STORY BUILDING NEW WINDOW TO REPLACE EXISTING NEW WINDOW TO REPLACE EXISTING NEW DOOR AND SIDELIGHTS TO REPLACE EXISTING PROPERTY LINE E 6TH STREETALLEY PROPERTY LINEPROPERTY LINEEXISTING AWNING ABOVE EXISTING STEPS EXISTING DOOR 1/8" = 1'-0"1 GROUND FLOOR/SITE PLAN Architect WITSELL EVANS RASCO 901 West Third Street Little Rock, Arkansas 72201 501.374.5300 www.WERarch.com SHEET REFERENCE: SHEET NUMBER Checked by: Drawn by: WER Job Number: Date: REFERENCE: A1.1CENTRAL ARKANSAS WATER314 E. 6th Street Renovation02/08/21 ADB BG CENTRA20.01FLOOR PLAN0 4 8 16 N 03/01/21 A2 4 A2 A2 3 1 A22 Architect WITSELL EVANS RASCO 901 West Third Street Little Rock, Arkansas 72201 501.374.5300 www.WERarch.com SHEET REFERENCE: SHEET NUMBER Checked by: Drawn by: WER Job Number: Date: REFERENCE: A1.2CENTRAL ARKANSAS WATER314 E. 6th Street Renovation02/23/21 Author Checker CENTRA20.01ROOF PLAN1/8" = 1'-0"1 ROOF PLAN MEMBRANE ROOF NEW HVAC CONDENSING UNITS 03/01/21 GROUND FLOOR 0" EXISTING METAL SHINGLE AWNING EXISTING PAINTED KING SIZE BRICK, TYP NEW WINDOW TO REPLACE EXISTING. FIXED WINDOW, DARK BRONZE FRAME AND MULLIONS, TYP NEW DOOR AND SIDELIGHTS TO REPLACE EXISTING. NEW TO HAVE DARK BRONZE FRAME AND DOOR PANEL NEW LIGHT FIXTURES, TYP REPLACE EXISTING WHITE SOFFIT PANEL WITH COLOR TO METAL SHINGLE EXISTING STEPS PAINTED MASONRY STEPS REMOVE EXISTING WOOD FRAMING TO ENLARGE OPENING TO EXISTING MASONRY OPENING SIZE, TYP GROUND FLOOR 0" REMOVE A/C UNIT, INFILL WITH BRICK AND PAINT TO MATCH3'-4"NEW HVAC CONDENSING UNITS GROUND FLOOR 0" REMOVE A/C UNITS, REMOVE BRICK TO LOWER SILL HEIGHT AND INFILL HEAD TO MATCH OPENING HEIGHT OF FRONT WINDOWS. PAINT TO MATCH EXISTING METAL SHINGLE AWNING EXISTING PAINTED KING SIZE BRICK, TYP NEW LIGHT FIXTURES NEW WINDOWS TO FILL OPENING, FIXED WINDOW WITH DARK BRONZE FRAME AND MULLIONS EXISTING DOOR TO REMAIN NEW HVAC CONDESNING UNITS GROUND FLOOR 0" REMOVE EXISTING A/C UNIT AND INFILL STUCCO. PAINT TO MATCH EXISTING PAINTED STUCCO EXISTING METAL SHINGLE AWNING EXISTING PAINTED KING SIZE BRICK, TYP NEW LIGHT FIXTURES NEW HVAC CONDENSING UNITS Architect WITSELL EVANS RASCO 901 West Third Street Little Rock, Arkansas 72201 501.374.5300 www.WERarch.com SHEET REFERENCE: SHEET NUMBER Checked by: Drawn by: WER Job Number: Date: REFERENCE: A2.1CENTRAL ARKANSAS WATER314 E. 6th Street Renovation03/01/21 Author Checker CENTRA20.01ELEVATIONS1/8" = 1'-0"1 SOUTH ELEVATION 1/8" = 1'-0"2 NORTH ELEVATION 1/8" = 1'-0"3 WEST ELEVATION 1/8" = 1'-0"4 EAST ELEVATION 1 2 3 4 120'-0" 60'-0" 60'-0" 120'-0" HVAC CONDESNING UNITS E 6TH STREETArchitect WITSELL EVANS RASCO 901 West Third Street Little Rock, Arkansas 72201 501.374.5300 www.WERarch.com SHEET REFERENCE: SHEET NUMBER Checked by: Drawn by: WER Job Number: Date: REFERENCE: A3.1CENTRAL ARKANSAS WATER314 E. 6th Street Renovation02/23/21 Author Checker CENTRA20.01STREET LEVEL VIEWS1" = 60'-0"5 KEY PLAN 1 LOOKING WEST @ 60'-0"2 LOOKING WEST @ 120'-0" 3 LOOKING EAST @ 60'-0"4 LOOKING EAST @ 120'-0" 03/01/21 REQUIRED PHOTOGRAPHS OF EXISTING BUILDING AND SITE PAGE 1 - EXITSING BUILDING PAGE 2 - EXISTING SITE NOTE: SEE IMAGES IN SEPARATE FILE FOR HIGH-RESOLUTION .JPG IMAGES SOUTH ELEVATION - 1EAST ELEVATION - 2 NORTH ELEVATION - 4 WEST ELEVATION - 3 EXISTING BUILDING PHOTOGRAPHS NORTH SIDE - 1 NORTH SIDE - 2 NORTH SIDE - 3 SOUTH SIDE - 1 SOUTH SIDE - 2 CONTEXT PHOTOGRAPHS REQUIRED SUBMITTALS ON MATERIAL SELECTION. 1. KAWNEER NX-300 REPLACEMENT WINDOW 2. KAWNEER 350T REPLACEMENT ENTRANCE 3. EXTERIOR LIGHT FIXTURE 4. REPLACMENT SOFFIT PANELS 5. HVAC UNITS SEE FOLLOWING PAGES FOR ADDITIONAL INFORMATION. KAWNEER NX-300 FIXED WINDOW - DARK BRONZE BASIS OF DESIGN design and installation versatility for replacing existing wood or steel installations. Made from aluminum and designed for superior durability, NX-300 Series Thermal Windows are engineered to withstand extreme temperatures and conditions. VERSATILITY A variety of casement outswing, project-out (awning), fixed and fixed over project-out configurations are available to suit most applications. Units can be used in punched openings or be stacked vertically or horizontally. An assortment of structural mullions allows for larger unit configurations, while several options for anchoring methods, head and jamb receptors, sub-sills and panning types allow for installation flexibility. Experience the unexpected with an architectural-grade, value-priced window with flexible options for a historic look. The strong lines of the new NX-300 Series Thermal Windows lend a historic appearance to projects, blending seamlessly with the architecture of older buildings. The windows come with a 3-1/4" depth frame and 2-5/8" sightline, and have been tested to U.S. and Canadian standards. With AAMA architectural grade ratings up to AW-PG90 on most common configurations, NX-300 Series Thermal Windows reach higher performance criteria than ever. Ideal for the architectural details of historical window restorations on low- to mid- and high-rise commercial, education, multifamily and public projects, NX-300 Series Thermal Windows achieve the putty- glazed, beveled-sash window look. A variety of options allows for the NX-300 SERIES THERMAL WINDOWS Innovation, Preservation and Performance for Historic Results Kawneer Company, Inc. Technology Park / Atlanta ARCHITECTURAL SYSTEMS | ENTRANCES + FRAMING | CURTAIN WALLS | WINDOWS 555 Guthridge Court Norcross, GA 30092 770.449.5555 kawneer.com © Kawneer Company, Inc. 2019 Form Number 17-2264.A PERFORMANCE NX-300 Series Thermal Windows deliver high thermal performance and minimized condensation with insulating glass options and polyamide thermal breaks, which increase occupant comfort and lower energy expenditures. A frame design with 0.125" wall thickness provides strength and minimal sightlines, while friction position corner keys provide accurate alignment throughout the window assemblies. The windows are tested in accordance with AAMA/WDMA/CSA 101/I.S. 2/ A440 NAFS – North American Fenestration Standard/Specification for windows, doors and skylights. MODEL AW RATING FUNCTION NX-310 AW-PG90-C Outswing Casement NX-350 AW-PG90-AP Project-Out (Awning) NX-380 AW-PG90-FW Fixed Window FEATURES & AESTHETICS The NX-300 Series Thermal Window is packed with features that make installation easier and more economical, giving architects and design professionals the ability to create the appearance of historic structures with the modern performance of advanced window systems from a single-source supplier. When a building needs to reflect a historic aesthetic yet operate with modern performance, NX-300 Series Thermal Windows from Kawneer are an excellent solution. Contact us today to learn more about how NX-300 Series Thermal Windows can deliver innovative preservation and performance for your next historic low- to mid- or high-rise project. Typical Panning Options 3-Piece Mullion Options Minimal sightlines for historic replication needs Optional interior and/or exterior muntins Putty-glazed, beveled-sash window look Insulating glass for high thermal performance Polyamide thermal breaks Interior and exterior dual finish options for design flexibility NX-300 WINDOW IN OPEN POSITION NX-300 WINDOW IN CLOSED POSITION Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© Kawneer Company, Inc., 20174 kawneer.com EC 97911-197 NX-300 Series Thermal Windows ADME350EN MARCH, 2019 NX-380 FIXED WINDOW CLASS and GRADE Architectural Class AW-PG90-FW TESTING STANDARD AAMA / WDMA / CSA / 101 / I.S.2 / A440 (NAFS) FRAME DEPTH 3-1/4" Overall Frame Depth TYPICAL WALL THICKNESS .125" Nominal Frame TYPICAL MAXIMUM SIZE 60" x 99" TYPICAL MINIMUM SIZE 17" x 17" TYPICAL CONFIGURATIONS INFILL OPTIONS 1" STANDARD HARDWARE Not Applicable OPTIONAL HARDWARE Not Applicable OTHER OPTIONS Structural Mullions Vertically or Horizontally Stacked Receptor and Sub Sill Panning Exterior or Interior Muntins Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© Kawneer Company, Inc., 20176 kawneer.com EC 97911-197 3-1/4"(82.6)1-13/32" (35.7)3/8" (10)1-13/32"(35.7)3-1/4" (82.6)3/8"(10)1-13/32"(35.7)3/8"(10)1-13/32"(35.7)VARIES1 3 4 5 2 3A 6 3/4" (19.1)3/4"(19.1)3-1/4"(82.6)1-13/32" (35.7)3/8" (10) NX-300 Series Thermal Windows ADME350EN MARCH, 2019 Additional information and CAD details are available at www.kawneer.com (Nominal Dimensions Shown) 1 HEAD D.L.O.W.D.O.D.3 SILL D.L.O.W.D.O.D.2 HORIZONTAL 4 JAMB D.L.O. O.D.D.L.O.D.L.O.W.D. 3A SILL D.L.O.W.D.O.D.5 VERTICAL D.L.O.D.L.O. NX-380 FIXED WINDOW TYPICAL ELEVATION 6 JAMB D.L.O. O.D. W.D. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© Kawneer Company, Inc., 201717 kawneer.com EC 97911-197 IF-1445 S-11055 S-11056 S-11055 S-11056 H-11075 S-11055 S-11056 S-11055S-11056 IF-1472 H-11075 20-0930 50-2381 NX-300 Series Thermal Windows ADME350EN MARCH, 2019 ANCHORS 3-PIECE MULLIONS STANDARD FRAME FILLER AND STRAP ANCHOR KAWNEER 350T ENTRANCE DOOR + SIDELIGHTS - DARK BRONZE BASIS OF DESIGN 250T/350T/500T INSULPOUR® THERMAL ENTRANCES Redefining Thermal Entrances with IsoPour™ Technology By merging industry-proven pour and debridge and polymer isolator technologies, Kawneer’s IsoPour™ Thermal Break technology creates thermally broken assemblies for enhanced building energy efficiencies with higher structural performance. Insulpour® Thermal Entrances simultaneously provide additional design flexibility through multiple door cross-rail and bottom rail choices along with dual finish capabilities for the door and door frame. Ask more from your door, and get it all with Kawneer’s new Insulpour® Thermal Entrances, featuring IsoPour™ technology. This innovative product offering gives architects, developers, owners, and glazing contractors the ability to create a true thermally broken entrance system. It’s an ideal solution for high-end commercial and multifamily facilities looking to improve thermal control in common areas with moderate to high traffic. Kawneer Company, Inc. Technology Park / Atlanta ARCHITECTURAL SYSTEMS | ENTRANCES + FRAMING | CURTAIN WALLS | WINDOWS 555 Guthridge Court Norcross, GA 30092 770.449.5555 kawneer.com© Kawneer Company, Inc. 2018–2020 Form Number 18-2330.C IsoPour™ is a trademark and Insulpour® is a registered trademark of Kawneer Company, Inc. PERFORMANCE, STRENGTH & SECURITY The door and frame both leverage IsoPour™ Thermal Break technology, enabling high thermal performance. Specifically aimed at quelling concerns about cold spots and thermal bridging from architects and specifiers, Insulpour® Thermal Entrances feature a true thermally broken door header, which significantly mitigates the formation of condensation when used with a concealed overhead closer. Insulating glass unit options of double pane 1" (25.4 mm) or triple pane 1-1/2" (38.1 mm) improve thermal and sound reduction performance. For added strength, the 2-1/4" (57.2 mm) deep door has a stout 1/8" (3.2 mm) wall thickness, and the dual-welded corner construction of Insulpour® Thermal Entrances adds long-term performance. Each door corner comes with a limited lifetime warranty, good for the life of the door under normal use operation. It is transferable from building owner to owner and is provided in addition to the standard two-year warranty covering material and workmanship of each Kawneer door. Insulpour® Thermal Entrances meet ASTM E1996 hurricane impact resistant requirements up to Zone 4 and Level D, and have undergone shock tube testing for blast mitigation. Contact your local Kawneer sales representative for limitations and specific application requirements. AESTHETICS & DESIGN FLEXIBILITY With sightlines that match standard, non-thermally broken entrances, Insulpour® Thermal Entrances offer 250T narrow, 350T medium and 500T wide stile options. VERTICAL STILE TOP BOTTOM RAIL 250T Narrow Stile 2-1/2" (63.5 mm) 2-15/16" (74.6 mm) 3-7/8" (98.4 mm) 350T Medium Stile 3-1/2" (88.9 mm) 3-1/2" (88.9 mm) 6-1/2" (165.1 mm) 500T Wide Stile 5" (127 mm) 5" (127 mm) 6-1/2" (165.1 mm) The unique thermal break design allows for a wider choice of locking option hardware than previous thermal entrance designs. Coupled with various cross-rail sizes and multiple bottom rail heights of 7-1/2" (190.5 mm), 10" (254 mm) and 12" (304.8 mm), Insulpour® Thermal Entrances give architects, designers and building owners more opportunities to bring their vision to life. Larger door stile cavity design allows for more hardware options Insulating glass unit options of double pane 1" (25.4 mm) or triple pane 1-1/2" (38.1 mm) improve thermal and sound reduction performance Options include butt hinges (shown), offset pivots and continuous gear hinges Wide selection of cross- rail and door bottom rails available to meet aesthetic design and code requirements The combination of a thermally broken threshold and dual bottom door sweeps improves thermal performance and minimizes air infiltration Proven corner construction, with four Sigma deep penetration and fillet welds, plus mechanical fastening at each corner provides superior strength Interior and exterior dual finish options provide design flexibility Innovative IsoPour™ Thermal Break technology enhances performance and design flexibility 350T MEDIUM STILE INSULPOUR® THERMAL ENTRANCE Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.kawneer.com 6 EC 97911-233 3 2 1 44-5/16"(1125.5)40-13/16"(1036.6)3 2 1 3 2 1 44-5/16"(1125.5)1686 = 40" (1016)1786 = 40" (1016)8600 = 41-11/16" (1058.9)8400 = 40-13/16" (1036.6)1690 = 40-5/8" (1031.9)1790 = 41-5/16" (1049.3)2 3-7/8"(98.4)(57.2)2-1/4"3 1 2-15/16"(74.6)9/16"(14.3)(57.2) 2-1/4"(57.2)2-1/4"33-1/2"(88.9)1 (57.2)2-1/4"35"(127)1 2 6-1/2"(165.1)2 6-1/2"(165.1)250T/350T/500T Insulpour® Thermal Entrances ADMA090EN JULY, 2020 DOOR TYPES/SECTION DIMENSIONS 250T NARROW STILE 350T MEDIUM STILE 500T WIDE STILE STANDARD LOCATIONS STANDARD LOCATIONS 250T NARROW STILE SINGLE ACTING 350T MEDIUM STILE SINGLE ACTING 500T WIDE STILE SINGLE ACTING TOP ATTACHMENT BOTTOM OF DOOR OF CYL. CL TOP ATTACHMENT BOTTOM OF DOOR EXIT LOCK CYLINDER CL STANDARD EXIT DEVICE OF CRASH BAR FOR KAWNEER STANDARD EXIT DEVICECLOF CRASH BAR FOR ADAMS RITECLOF CRASH BAR FOR FALCONCLTYPICAL TYPICALAdditional information and CAD details are available at www.kawneer.com VARIESIsoPour® THERMAL BREAK Note: 1-1/2" (38.1) Triple Insulating Glass Unit infill available. DOOR STYLE Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.kawneer.com 7 EC 97911-233 1 32 4 5 6 7 8 15, 15A 1 2 3 11 1 3 15, 15A 11 10, 10A 1 2 4 11 9 1 3 10, 10A 11 9 7 866 5 12 14 13 250T/350T/500T Insulpour® Thermal Entrances ADMA090EN JULY, 2020 CONSTRUCTION DETAILS NOTE: 1. SERIES 250T NARROW STILE DOORS ARE DETAILED, MEDIUM STILE 350T DOORS AND WIDE STILE 500T DOORS ALSO MAY BE USED. 2. TRIFAB® VG 451T CENTER, 2" x 4-1/2" (50.8 x 114.3) FRAMING IS DETAILED WITH THE DOORS FOR REFERENCE. OTHER KAWNEER FRAMING SERIES OR CURTAIN WALL SYSTEMS MAY BE USED. 534007 TRANSOM GLASS STOP SINGLE ACTING DOORS Additional information and CAD details are available at www.kawneer.com SINGLE DOOR WITH SIDE LITES Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.kawneer.com 8 EC 97911-233 9 11 10A 14 13 15 12 11 15A 10 2-1/4"(57.2)2-1/4"(57.2)250T/350T/500T Insulpour® Thermal Entrances ADMA090EN JULY, 2020 CONSTRUCTION DETAILS OPTIONAL BOTTOM RAIL WEATHERING OPTIONAL BOTTOM RAIL WEATHERING 450022 GLASS STOPS 450022 GLASS STOPS SINGLE ACTING DOORS COC WITH SINGLE ACTING OFFSET ARM SURFACE OVERHEAD CLOSER CONSEALED OVERHEAD CLOSER Additional information and CAD details are available at www.kawneer.com Kawneer reserves the right to change configuration without prior notice when deemednecessary for product improvement.© 2018, Kawneer Company, Inc.Laws and building and safety codes governing the design and use of Kawneer products, such as glazed entrance, window, and curtain wall products, vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.kawneer.com 18 EC 97911-233 1-3/8"2-1/4"3-1/2"6"8-1/4"532133 532132 532131 532130 532129 (34.9)(57.2)(88.9)(152.4)(209.6)9/16"(14.3)1/2" (12.7)1"(25.4)069141 1/2"(12.7)6-3/4" (171.5)1/2"(12.7)534107 4-3/4" (120.7) 1/2" (12.7)1-1/2"(38.1)250T/350T/500T Insulpour® Thermal Entrances ADMA090EN JULY, 2020 INFILL OPTIONS ACCESSORY ITEMS 069177 APPLIED DOOR STOP HORIZONTAL / VERTICAL CROSS RAILS INTERMEDIATE RAILS, INFILL OPTIONS AND ACCESSORIES 1" (25.4) INFILL STANDARD 1" INFILL TAPE GLAZED (Blast) 1" INFILL WET GLAZED (Blast) SQUARE GLASS STOPS CROSS RAIL (Optional) Additional information and CAD details are available at www.kawneer.com TYP.THRESHOLDS APPLICATION FOR SINGLE ACTING DOOR SOME BUILDING CODES LIMIT THRESHOLD HEIGHT TO 1/2" (12.7) MAX. FOR FLOOR CLOSERS 069201 APPLIED DOOR STOP 1-1/2" INFILL (Triple Insulating Glass Unit) INTERMEDIATE MULLIONS KAWNEER FRAME COLOR - DARK BRONZE HINKLEY LED WALL MOUNT CYLINDRICAL LIGHT FIXTURE BASIS OF DESIGN https://lighting.tecelectric.com/hinkley/13590bk-ll/led-wall-mount EXTERIOR LIGHT FIXTURE EMCO VENTED METAL SOFFIT PANEL BASIS OF DESIGN METAL SOFFIT PANELS AVAILABLE COLORS FOR MATCHING TO AWNING SHINGLE - FINAL YET TO BE SELECTED https://www.emcobuildingproducts.com/Aluminum-Soffit-Panels ROOF MOUNTED HVAC UNITS BASIS OF DESIGN Job Name Location Date Engineer Approval Submitted To Construction Submitted By Unit No Reference Drawing No System 36RLXFZ1 Outdoor Unit AOU36RLXFZ1 Indoor Unit Non-Ducted Ducted Mix SEER 18 16 17 EER 10 9 9.5 HSPF 9.4 8.7 9.1 kW/kW 3.563.323.44 Btu/hW 12.1 11.3 11.7 Cooling 14 to 115 (-10 to 46) Heating 5 to 75 (-15 to 24) Total Capacity Range 27,000 to 39,000 Btu/h Rated 35200 Min.—Max. 11,000—38,000 Rated 36400 Min.—Max. 11,000—42,000 LINESET REQUIREMENTS Connection Method Flare Cooling 2,119 (3,600) Liquid Ø1/4 (Ø6.35) × 4 Heating 2,237 (3,800) Gas Ø3/8 (Ø9.52) × 3 + Ø1/2 (Ø12.7) × 1 Pre-Charge Length ft (m) 164 (50)** Slim Duct (ARU) Maximum Length 230 (70) Wall Mount (ASU) Maximum Length Each 82 (25) Compact Cassette (AUU) Minimum Length 66 (20) Floor Mount (AGU) Minimum Length Each 16 (5) NUMBER 2 to 4 Max. Height Diff. 49 (15) OOUTDOOR DIMENSIONS & WEIGHT in 32-11/16 × 35-7/16 × 13 mm 830 × 900 × 330 in 39-3/8 × 41-5/16 × 17-1/2 mm 1,000 × 1,050 × 445 Net Weight 149 (68) Gross Weight 168 (76) SOUND PRESSURE Cooling 53 Heating 55 Outdoor Unit ETL#: 91987 Effective Date: 10/16/2019 Version 36RLXFZ1 -2019A SUBMITTAL 36RLXFZ1 #REF! PRODUCT FEATURES ᛫ Operate as few as one indoor unit or all indoor units ᛫ Mix & match from 4 indoor unit styles ᛫ Blue-fin condenser coil coating MODEL NUMBERS Warranty Information OUTDOOR TEMPERATURE OPERATION RANGE EFFICIENCIES COP 7 Year Compressor, 5 Year Parts out-of-the-box Warranty 10 Year Compressor, 10 Year Parts Warranty when registered within 30 days of installation in a residence˚F(˚C) CAPACITIES 12 Year Compressor, 12 Year Parts Warranty when registered within 30 days of installation in a residence, and installed by a Fujitsu Elite contractor FAN DATA Gross (H x W x D) Net (H x W x D) in (mm) Cooling Heating BTU/hW CONNECTABLE INDOOR UNIT Outdoor Unit Airflow Rate CFM (m3/h) Fujitsu General America, Inc. • 353 Route 46 West Fairfield, NJ 07004 • Toll Free: (888) 888-3424 • www.fujitsugeneral.com Due to continuous product improvements, specifications are subject to change without notice. Please log in to the Fujitsu Portal for the most up-to-date documentation https://portal.fujitsugeneral.com dB (A)Outdoor Unit TYPE lb (kg) 36,000 BTU Multi Zone SystemInverter Driven Heat Pump Type R410A lb oz 7 lb 1 oz g0 Oil Type RB68 ELECTRICAL SPECIFICATIONS Non-Ducted Ducted Mix 1Ø 208/230 V 60 Hz Voltage Range 187—264V Cooling 15.4 17.1 15.9 Heating 13.1 15.1 14.1 20.3 Starting Current 17.1 24.6 30 Cooling 3.52 3.92 3.71 Heating 33.223.11 Cooling 4.14.384.24 Heating 3.73.853.78 DIMENSIONS Units: In. (mm) Fujitsu General America, Inc. • 353 Route 46 West Fairfield, NJ 07004 • Toll Free: (888) 888-3424 • www.fujitsugeneral.com A Maximum Circuit Breaker Maximum Operating Current MCA Max. Input Power (kW) Rated Input Power (kW) The Fujitsu logo is a worldwide trademark of Fujitsu General Limited. The Halcyon logo and name is a worldwide trademark of Fujitsu General Limited and is a registered trademark in Japan, the USA and other countries or areas. Copyright 2018 Fujitsu General America, Inc. Fujitsu’s products are subject to continuous improvements. Fujitsu reserves the right to modify product design, specifications and information in this brochure without notice and without incurring any obligations. Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80°F (26.7°C) DB/67°F (19.4°C) WB, and outdoor temperature of 95°F (35°C) DB/75°F (23.9°C) WB. Heating: Indoor temperature of 70°F (21.1°C) DB/60°F (15.6°C) WB, and outdoor temperature of 47°F (8.3°C) DB/43°F (6.1°C) WB. Pipe length: 25ft. (7.5m), Height difference: 0ft. (0m) (Outdoor unit – indoor unit). Rated Current (A) REFRIGERANT Charge Voltage/Frequency/Phase #REF! SUBMITTAL 36RLXFZ1 36,000 BTU Multi Zone SystemInverter Driven Heat Pump