Loading...
HomeMy WebLinkAbout20170609_TR_Brian Minyard_Fassler Hall_Historic Commission Submission To: Department of Planning and Development  723 West Markham Street  Little Rock, AR 72201  From: James Sullivan for AMR  Date: 06.09.17  Project:   Fassler Hall ‐ LR    Attn: Brian Minyard    We are sending you the following items:                 AAttttaacchheedd  UUnnddeerr     SSeeppaarraattee  CCoovveerr        PPllaannss   SSppeecciiffiiccaattiioonnss   CChhaannggee  OOrrddeerr              SShhoopp  DDrraawwiinngg  SSuubbmmiittttaallss  //   PPrroodduucctt  DDaattaa              PPrriinnttss   SSaammpplleess  OOtthheerr    Copies: Date: Number: Description: Note:  01    Revised Drawings for Historic Commission – 24 x 36   12    Revised Drawings “ “ “ – 11 x 17    13     Exterior Light Fixture Cutsheets                       Please see the following attached letter.       Thank you,  James Sullivan    NOTES:      Retain one copy of approved shop drawings & submittals for the Owner’s Close‐out documents.     06/09/17 REVISED DRAWINGS FOR HISTORIC COMMISSION Brian, The following changes have been made to the design since our last submission:  The exterior patio has changed: o The overall area of the patio has increased from 2,737SF to 6,350SF.  The previously area was approximately 22’ wide and 140’ long along the west side of the building. The south half of that 140’ (approximately) now extends west to Cumberland Street in the new layout. o A portion of the patio is raised 1’ higher than the existing asphalt, and surfaced with compacted granite fines. o The perimeter fence has changed from a wood-clad base with ornamental metal posts and rails to a skim coated painted cmu base with cedar posts and horizontal slat rails. o 2” x 1-1/2” steel posts will mount along the perimeter fencing spaced approximately 10’ apart to allow for the suspension of string lights above the patio. o The height of the majority of the fencing has reduced from 6’ to 4’-6” tall.  At the southeast corner of the patio, a portion of the fencing will need to increase to approximately 13’-1” in order to fully conceal mechanical equipment.  The West elevation has changed: o The new openings along the façade have reduced from (3) 12’ wide by 10’ tall sections of storefront with 4 swinging doors each to (1) 12’-6” x 10’-3” section, (1) 6’-6” x 10’-3” section, and (1) 4’ x 8’ sliding window. o The awnings above the new openings have changed from wood clad with painted letters to light aluminum frame fabric awnings with printed letters. o The diamond-patterned mural at the south end has shifted slightly to appear more continuous as it crosses over the new mechanical yard fencing. o (3) previously proposed goose neck light fixtures at the south end of the façade will now be totally concealed by the tall mechanical yard fence, and replaced with (1) LED wall pack light fixture.  The East elevation has changed: o The previously proposed (3) overhead doors have been eliminated, and the existing windows will remain. o The existing overhead door will be exchanged for a smaller overhead door, and adjacent swinging door to all fit within the existing overhead door opening. o An additional swinging door has been added towards the south end of the building for code-required egress. o A kitchen hood exhaust fan has been positioned towards the south end of the façade. o (13) previously proposed goose neck light fixtures along the façade have been replaced with (3) LED wall packs.  Please note the alley is no longer being programmed as an outdoor patio.  The North elevation has changed: o We propose to leave the alley gate the black ornamental metal fence it currently is. o The sign above the entrance has changed from a suspended wood sign, to vinyl letter mounted to the glass. o The previously proposed metal screen has been eliminated o The proposed metal letters will be backlit with concealed LED strips. Thank you, James Sullivan SBREFURBISH EXISTINGWINDOWS. REPAIR /REPLACE BROKEN/DAMAGED GLASS,SEALANT, ETCAS NECESSARY6'-6"12'-6"EQ EQ EQ EQ EQEQ EQ EQ EQ EQ EQ EQCOMPACTED GRANITE FINESOVER GRAVEL - 1'-0" HIGH TOTALSTACKED STONE PAVERSTEPS W/ PTD MTLHANDRAILS EA SIDE &CENTERCAST CONCRETE RAMPW/ PTD MTL HANDRAILSEA SIDE1:12 SLOPE MAX12'-0"1:12 SLOPE MAX12'-0"EXISTING LANDSCAPE AREA@ ORIGINAL GRADEPOURED CONCRETELANDING & RAMP W/PTD MTL HANDRAILS EA SIDEEXISTING & NEWLYPATCHED ASPHALT- PAINT SURFACE64'-0 3/8"66'-4 1/4"64'-8"26'-0"+ 1' - 0"0' - 0"RUN THIS LEGOF FENCING SOUTHTO EXISTING FENCEEXISTING GAS METER- SEE MECH FORFINAL LOCATIONSEE SHEET A4.1 FORINFORMATION ON NEW FLOORSLAB IN ELEV LOBBYSTEEL STAIRCONC. PANNOTE:1. DIMENSIONS TAKEN FROM FACE OF EXISTING WALLS OR FACE OF STUD.2. REFER TO PLUMBING AND ELECTRICAL DRAWINGS FOR EQUIPMENT REQUIREMENTSDASH INDICATESSTRING LIGHTS-SEE ELEC.EQBUILDING NOTIN SCOPE70'-8 1/2" 21'-7 5/8" 49'-11 5/8"7'-6 3/8" 26'-2"20'-3 5/8"148'-9 7/8"PROJECTBUILDINGPROJECTPATIOENTRANCEMECHANICALYARDBAR IS ONE INCH ON ORIGINAL DRAWING..ONTS77CRCETIHC.RASNAKRAERGMAAARCHITECTS, INC.IF NOT ONE INCH ON THIS SHEETADJUST SCALES ACCORDINGLYBAR IS ONE INCH ON ORIGINAL DRAWING01"100 River Market Ave St. 301Little Rock, AR 72201501.375.0378 T501.375.6601 FProject:Location:Date:Title:Sheet Number:VERIFY SCALEFASSLER HALL - LITTLE ROCK311 E CAPITOL AVE, LITTLE ROCK, AR 7220201/13/2017FLOOR PLANHC_A1.01Revision History# Date Description01 03/07/17 ASI-01SCALE: 1/8" = 1'-0"1FIRST FLOOR PLAN_HCN FIRST FLOOR0"SECOND FLOOR13' - 10"ROOF27' - 8"THOROLASTIC WALL COATINGOVER ENTIRE BRICK SURFACEDECORATIVE WALL STENCILING & PAINT;PAINT OVER THOROLASTICPAINT PATTERN OVEREXISTING DOOR & FRAMEINFILL REMOVED WINDOWW/ BRICK & PAINT TO MATCHREPAIR STUCCOAT BASEREPAIR STUCCO &DOWNSPOUT AT BASEREPAIR STUCCO AT BASEREPAIR STUCCO BASE AT PILASTER& BRICK AT DOOR FRAMEREPAIR DEEP CRACKIN STUCCOEXISTING ELEC. CONDUITPAINT TO MATCH WALL-REFER TO ELEC. PLANFOR SELECTIVE DEMOREMOVE EXIST'G VENTS& PATCH HOLES W/ MTL. PLATE-PAINT TO MATCH WALLEXHAUST FANSEE MECH.EXISTING DOORTO REMAINNEW 3X7 METALEXIT DOOREXISTING WINDOWS TO REMAIN& BE REPAIRED AS NEEDEDNEW OVERHEAD & SWINGDOOR TO BE INSERTED INEXISTING OVERHEAD DOOROPENINGLED WALL PACK LIGHTLED WALL PACK LIGHTLED WALL PACK LIGHTFIRST FLOOR0"SECOND FLOOR13' - 10"ROOF27' - 8"11 GAUGE CUSTOM CUT METAL LETTERS;WALL MOUNTED W/ STL. ANGLE BOLTEDINTO HORIZONTAL BRICK JOINTS.BACKLIT; SEE ELEC5'-3"22'-8"NEW STOREFRONTDOORS IN EXISTINGSTOREFRONT SYSTEMEXISTING BRICK TO REMAINTUCKPOINT & PROVIDE CLEARWATER REPELLANT COATINGEXISTING STOREFRONT & CURTAIN WALL TO REMAIN;REPAIR, CLEAN & POLISH.ADJACENT BUILDING& SOLID BRICK FENCE(DASHED) -NOT IN SCOPEPROJECT FENCING BEYOND(LIGHT LINES)STRING LIGHTS; SEE ELECREPLACE THIS PANEDUE TO CRACKED GLASSREPLACE THIS PANEDUE TO CRACKED GLASSREPAIR STUCCOAT BASESCRAPE AWAY PEELINGPAINT & REPAINT ALL WHITESTUCCO & CONCRETE-TYP AROUND BUILDINGVINYL LETTERS &NUMBERS ON GLASSEXISTING METAL GATETO REMAINHORIZONTAL PLANK CEDAR FENCE.CMU BLOCK BASE TO BE SKIM COATED& PAINTED IN RAISED EXTERIOR AREAS; SEE PLANSMETAL CLAD CANOPYW/ SOFFIT CAN LIGHTINGFIRST FLOOR0"SECOND FLOOR13' - 10"ROOF27' - 8"THOROLASTIC WALL COATINGOVER ENTIRE BRICK SURFACEDECORATIVE WALLSTENCILING & PAINT; PAINTOVER THOROLASTICFIRST FLOOR0"SECOND FLOOR13' - 10"ROOF27' - 8"BASF THOROLASTIC WALL COATINGON ALL BRICK AT SOUTH, EAST, & WESTELEVATIONS; STANDARD COLORDECORATIVE WALL STENCILING &PAINT; PAINT OVER THOROLASTICDECORATIVE WALL STENCILING &PAINT; PAINT OVER THOROLASTIC(OR OTHER WEATHERPROOFING) LAYERSALUM FRAME FABRIC AWNINGS W/LETTERING @ FRONT VALANCENEW ALUM STOREFRONT DOORS& TRANSOM SYSTEMNEW SLIDING STOREFRONTWINDOW - SEEEQ EQEQ EQEQ EQNEW WALL MOUNTEDLIGHT FIXTURESEXISTING GASMETERREMOVE EXISTINGLIGHT FIXTURE& PATCH BRICKREMOVE AIR UNIT & INFILL W/BRICK -PAINT TO MATCHSLIDESLIDE8 / A2.01TO CONCEAL MECH EQUIP13'-1" AFFEXISTING STOREFRONT & CURTAIN WALL TO REMAIN;REPAIR, CLEAN & POLISH.STOP STENCILING BEHINDFENCE11'-0"14'-9 1/4"6'-0"7'-6"14'-7 3/4"10'-4 3/4"16'-11"6'-10"8'-0"12'-6"10'-3"6'-6"8'-0"3'-6" 4'-0"TOP OF FENCE LINEBEYOND (DASHED)LED WALL PACKLIGHT FIXTUREINSIDE ENCLOSUREADJACENT BUILDING AND SOLID BRICKFENCE (DASHED) - NOT IN SCOPEPROJECT BEYOND (LIGHT LINES)BAR IS ONE INCH ON ORIGINAL DRAWING..ONTS77CRCETIHC.RASNAKRAERGMAAARCHITECTS, INC.IF NOT ONE INCH ON THIS SHEETADJUST SCALES ACCORDINGLYBAR IS ONE INCH ON ORIGINAL DRAWING01"100 River Market Ave St. 301Little Rock, AR 72201501.375.0378 T501.375.6601 FProject:Location:Date:Title:Sheet Number:VERIFY SCALEFASSLER HALL - LITTLE ROCK311 E CAPITOL AVE, LITTLE ROCK, AR 7220201/13/2017EXTERIOR ELEVATIONSHC_A2.01Revision History# Date DescriptionSCALE: 1/8" = 1'-0"3EAST ELEVATION_HCSCALE: 1/8" = 1'-0"5NORTH ELEVATION_HCSCALE: 1/8" = 1'-0"4SOUTH ELEVATION_HCSCALE: 1/8" = 1'-0"1WEST ELEVATION_HCSCALE: 1/8" = 1'-0"2WEST ELEVATION 2_HC FIRST FLOOR0"1'-0"6"1'-0"1'-6"3'-0"6" STACKEDSTONE PAVERSPTD METAL HANDRAILBEYOND-SET IN CONCRETECOMPACTED GRANITEFINES OVER GRAVEL1'-0" HIGH TOTALEXISTING ASPHALTPARKING LOTGRT FINES OVER GRVL1'-0"1'-0"OVERLAP6"3'-6"FIRST FLOOR0"2" CMU CAPCMU BLOCKW/ REBAR & FILLW/ MORTAR-SEE STRUC FORLOCATIONSGALV HSS 2X1 1/2-REFER TO STRUC.STRING LIGHTS; SEE ELECSTRIKE MORTAR JOINTSFLUSH @ ALL BLOCK WALLS-TYPCEDAR 6 X 6 POSTCEDAR 1 X 6 PLANKW/ 1/2" SPACING1X CEDAR PLANK CAPCOMPACTED GRANITEFINES OVER GRAVEL1'-0" HIGH TOTALEXISTING ASPHALTPARKING LOT1'-0"1/4" PLATE W/ ADHESIVE POSTANCHOR SYSTEM-REFER TO STRUC.4'-6"2'-0"T.O. STL. POST11'-0"1/2"CONCRETE PIER@ 2'-8" O.C.-REFER TO STRUC.8"8"2"CEDAR 6 X 6 POST1/4" PLATE W/ ADHESIVE POSTANCHOR SYSTEM-REFER TO STRUC.GALV HSS 2X1 1/2-REFER TO STRUC.CEDAR 1 X 6 PLANKW/ 1/2" SPACINGBETWEEN BOARDS- PLANKS TO EXTERIORSIDE OF FENCE ONLYCOMPACTED GRANITEFINES OVER GRAVEL1'-0" HIGH TOTALEXISTING ASPHALTPARKING LOTCORRUGATED METALROOF; SEE STRUCTURAL1/2" BOLT FASTEN TO STUDS &METAL PANELS; ADJUST LENGTH BOLTLENGTH TO MAINTAIN LEVEL SOFFITCONT. PRE-FIN MTL FASCIACAN LIGHTS; SEE ELEC.CUT OPENING THRU PERF PANELS.EXISTING STOREFRONTEXISTING STUCCO FASCIA1" ROUND PERFORATED METALSOFFIT PANEL W/ 1/2" METAL WELDEDEDGE BANDING - PAINTEDSLOPE 1/4" PER FT MINMETAL STUD FRAMING;SEE STRUCTURAL FOR MEMBERS& FASTENING. SIDE STUD TRACKSTO SLOPE AGAINST BUILDING.1'-0"5'-0"4"REPLACE EXISTING GLASSWITH SPANDREL GLASSPANELS AT CENTERSECTION ONLYEXISTING STOREFRONTMETAL Z-FLASHING OVER STUCCO& ONTO METAL ROOF. APPLY SEALANTINSIDE CORRUGATIONSPROVIDE CLOSURES AT THEEND OF THE CORRUGATIONMETAL L-FLASHING AGAINSTBRICK SIDES & ONTO METALROOF (DASHED). APPLY SEALANTINSIDE CORRUGATIONSAPPLY METAL PANEL AT WEST CANOPYSIDE WHERE THERE A GAP DUE TOSTOREFRONT STEPPING BACK. FULLYCONCEAL CANOPY CAVITY.FIRST FLOOR0"MAX4"1'-6"EXISTING WALLLED LIGHT STRIP; SEE ELEC.SCREW FIXTURE INTO BRICK@ MORTAR ONLY4 1/2"COUNTER SINK BOLTS THRU TREATED 1x BLOCKING &BRICK; MOUNT LIGHT FIXTURE TO BLOCKINGLED LIGHT STRIP; SEE ELEC.SCREW FIXTURE INTO BRICK@ MORTAR ONLYNOTE: THERE ARE (2) VERITCAL STRIPS @ 7'-6" LONG& (2) VERTICAL STRIPS @ 13' LONG2'-2"BAR IS ONE INCH ON ORIGINAL DRAWING..ONTS77CRCETIHC.RASNAKRAERGMAAARCHITECTS, INC.IF NOT ONE INCH ON THIS SHEETADJUST SCALES ACCORDINGLYBAR IS ONE INCH ON ORIGINAL DRAWING01"100 River Market Ave St. 301Little Rock, AR 72201501.375.0378 T501.375.6601 FProject:Location:Date:Title:Sheet Number:VERIFY SCALEFASSLER HALL - LITTLE ROCK311 E CAPITOL AVE, LITTLE ROCK, AR 7220201/13/2017EXTERIOR DETAILSA2.02SCALE: 1 1/2" = 1'-0"3EX. PATIO STAIR PAVERSSCALE: 1 1/2" = 1'-0"1EX. PATIO FENCE @ CMU WALLSCALE: 1 1/2" = 1'-0"2EX. PATIO FENCE POST - PLAN DETAILRevision History# Date Description01 03/07/17 ASI-01SCALE: 1 1/2" = 1'-0"4SECTION @ ENTRANCE CANOPYSCALE: 1 1/2" = 1'-0"5METAL LETTERS & PLAN DETAIL Submitted by Malmstrom White CompanyJob Name: FASSLER HALLArchitect: AMR ARCHITECTS (LITTLEROCK)Engineer: JAMES PRIMM, PECatalog Number:QS-4W-O-100IN-120V-WM-STANDARD COLORNotes: Type: MWC17-7365ESTABLISHED 1923 Forte Wall Quickship Specifications are subject to change without notice. TMS Lighting Inc. 247A Summerlea Road, Brampton, Ontario, Canada. L6T 4E1 Web Site: tmslighting.com North America: (905) 793-1174 Toll-free: (866) 793-1174 Fax: (905) 793-1175 UK & Europe: 44-1474-250-654 Custom TMS Lighting can customize this and many of our standard fixtures. The dimensions, lamp types, enclosure and colors could be modified to suit your lighting and architectural requirements. Contact your local representative for more details: http://tmslighting.com/info/agents 33.37” (848 mm) 18.62” (473 mm) 16” dia. (406 mm) 3.36” (85 mm) Optional LED Driver or CF / MH Ballast EXTERIOR LIGHT FIXTURE ALONG WEST ELEVATION Submitted by Malmstrom White Company Job Name: FASSLER HALL Architect: AMR ARCHITECTS (LITTLE ROCK) Engineer: JAMES PRIMM, PE Catalog Number: XTOR6BRL Notes: Type: MWC17-7365 XTOR CROSSTOUR MAXX LED APPLICATIONS: WALL / SURFACE INVERTED SITE LIGHTING Lumark SPECIFICATION FEATURES Construction Low-profile LED design with rugged one-piece, die-cast aluminum back box and hinged removable door. Matching housing styles incorporate both a full cutoff and refractive lens design. Full cutoff and refractive lens models are available in 58W and 81W. Patent pending secure lock hinge feature allows for safe and easy tool-less electrical connections with the supplied push-in connectors. Back box includes four 1/2” NPT threaded conduit entry points. The back box is secured by four lag bolts (supplied by others). External fin design extracts heat from the fixture surface. One-piece silicone gasket seals door and back box. Not recommended for car wash applications. Optical Silicone sealed optical LED chamber incorporates a custom engineered reflector providing high-efficiency illumination. Full cutoff models integrate an impact-resistant molded refractive prism optical lens assembly meeting requirements for Dark Sky compliance. Refractive lens models incorporate a molded lens assembly designed for maximum forward throw. Solid state LED Crosstour MAXX luminaries are thermally optimized with eight lumen packages in cool 5000K or neutral 4000K (58W, 81W models) LED color temperature (CCT). Electrical LED driver is mounted to the die-cast aluminum housing for optimal heat sinking. LED thermal management system incorporates both conduction and natural convection to transfer heat rapidly away from the LED source. 58W and 81W models operate in -40°C to 40°C [-40°F to 104°F]. High ambient 50°C [122°F] models available in 58W and 81W models only. Crosstour MAXX luminaires maintain greater than 89% of initial light output after 72,000 hours of operation. Four half-inch NPT threaded conduit entry points allow for thru-branch wiring. Back box is an authorized electrical wiring compartment. Integral LED electronic driver incorporates surge protection. 120-277V 50/60Hz, 480V 60Hz, or 347V 60Hz electrical operation. 480V is compatible for use with 480V Wye systems only. Emergency Egress Optional integral cold weather battery emergency egress includes emergency operation test switch (available in 58W and 81W models only), an AC-ON indicator light and a premium extended rated sealed maintenance-free nickel-metal hydride battery pack. The separate emergency lighting LEDs are wired to provide redundant emergency lighting. Listed to UL Standard 924, Emergency Lighting. Area and Site Pole Mounting Optional extruded aluminum 6-1/2” arm features internal bolt guides for supplied twin support rods, allowing for easy positioning of the fixture during installation to pole. Supplied with round plate adapter plate. Optional tenon adapter fits 2-3/8” or 3-1/2” O.D. Tenon. Finish Crosstour MAXX is protected with a super TGIC carbon bronze or summit white polyester powder coat paint. Super TGIC powder coat paint finishes withstand extreme climate conditions while providing optimal color and gloss retention of the installed life. Warranty Five-year warranty. TD514005EN 2016-12-13 15:58:28 The patented Lumark Crosstour™ MAXX LED wall pack series of luminaries provides low-profile architectural style with super bright, energy-efficient LEDs. The rugged die-cast aluminum construction, back box with secure lock hinges, stainless steel hardware along with a sealed and gasketed optical compartment make Crosstour impervious to contaminants. The Crosstour MAXX wall luminaire is ideal for wall/ surface, inverted mount for facade/canopy illumination, perimeter and site lighting. Typical applications include pedestrian walkways, building entrances, multi-use facilities, industrial facilities, perimeter parking areas, storage facilities, institutions, schools and loading docks. DESCRIPTION CERTIFICATION DATA UL/cUL Wet Location Listed LM79 / LM80 Compliant ROHS Compliant NOM Compliant Models 3G Vibration Tested UL924 Listed (CBP Models) IP66 Rated TECHNICAL DATA 40°C Ambient Temperature External Supply Wiring 90°C Minimum EPA Effective Projected Area (Sq. Ft.): XTOR6B, XTOR8B=0.54 With Pole Mount Arm=0.98 SHIPPING DATA: Approximate Net Weight: 12-15 lbs. [5.4-6.8 kgs.] FULL CUTOFF DEEP BACK BOX DEEP BACK BOXREFRACTIVE LENS 8-3/4"[222mm] 8-3/4"[222mm]6-1/4"[159mm]7"[178mm] 6"[152mm]7"[178mm] 11 "[279mm] 11 "[279mm] DIMENSIONS Catalog # Type Date Project Comments Prepared by Index Page EXTERIOR LIGHT FIXTURE ALONG EAST ELEVATION & INSIDE FENCED MECHANICAL YARD Submitted by Malmstrom White Company Job Name: FASSLER HALL Architect: AMR ARCHITECTS (LITTLE ROCK) Engineer: JAMES PRIMM, PE Catalog Number: LS-MS-24-BK, (330) LS-CABLE- SPECIFY LENGTH, (5) LS-LOCK-4 Notes: Type: MWC17-7365 FEATURES • Factory-molded sockets on 14-gauge wire is suitable for commercial applications (16-gauge for kits) • Formulated PVC sockets form a tight weatherproof seal around the bulb • Long life, low maintenance linear lighting (for use with LED retrofits and Long Life Lamps – see pages 46-47) • Available in bulk reels in candelabra, intermediate and medium base sockets • Use with LED lamps to run full reel length and save up to 98% in energy costs over incandescent Light string CommErCiAL grADE Use commercial grade light string with LED lamps to run full reel length and save up to 80% in energy costs over incandescent. suitable for decorative lighting, patio lighting, tents, events, pavilions, sales lots and many overhead perimeter lighting applications. 44 www.americanlighting.com medium Base max load/socket 25 watts max load/socket 10 watts intermediate Base suspended medium Base max load/socket 25 watts Candelabra Base max load/socket 10 watts Popular, versatile, commercial grade light string CommerCial grade Light string Index Page STRING LIGHTS HUNG FROM POLES ABOVE THE EXTERIOR PATIO page 1 of 3 www.luminii.com tel: 224-333-6033REV 1.8 Kendo M Wet Graze Linear grazing system Technical information KMWG MODEL Ordering code 27K 27K - 2700 K30K - 3000 K40K - 4000 K45K - 4500 K 12 12”- 116” 4” increments F1 F1 - 72” wire leadsF2 - 72” wire leads at one end and quick connect at otherF3 - Single quick connectF4 - Dual quick connect Kendo M Wet Graze HO HO - HighVHO - VeryHigh 20 20° - Semi-frosted A A - AdjustableF - Fixed SA LENGTH POWER FEEDOUTPUTCCTLENSMOUNTINGFINISH SA - Silver BK - Black BZ - Bronze WH - White (BK,BZ,WH finishes will have an upcharge and require longer lead times) Finish options Black powder coated Bronze powder coated Silver anodized White powder coated Extruded aluminum linear grazing system, Kendo M Wet Graze features a 20° lightly frosted lens. Available in sections up to 116” long, Kendo M Wet Graze is suitable for highlighting textured surfaces, stone walls or for edge lighting. Class 2 listed for wet location installations. 0.79” 0.70” 90˚90˚ 0.82” 0.93” 0.70” Adjustable mounting bracket allows 90˚ tilt in both directions. 0.94” CRI (Typical) Color temperature High [+/- 75 K and single bin] 2700 K 90+ 3000 K 90+ 4000 K 90+ 4500 K 90+ Output Options Output type HO (LL54) VHO (LL72) Lumens at 3000K High CRI 243 lum/ft 343 lum/ft Average power consumption at 4’5.2 W/ft 6.5 W/ft Maximum system length 26’18’ Operating Voltage 24VDC 24VDC with fixed mounting clips 0.70” 0.73” CONCEALED EXTERIOR LIGHT STRIP AT METAL LETTERS ON NORTH FACADE