HomeMy WebLinkAbout20170519_Fassler Hall_T1.03_Seating and Plumbing Fixture Count PlanSB
112233A.1A.1BBCCDDEEFFGGAA1327226 SEATS INSIDE108 SEATS OUTSIDE6164816161615161666666666666666634EXTERIOR DINNING AREA6359 SF TOTAL44" WIDE EXIT PATH751 SF66888888814'-0"7'-0"3'-10 3/4"7'-0"26'-3"7'-2 3/8"BAR IS ONE INCH ON ORIGINAL DRAWING.IF NOT ONE INCH ON THIS SHEETADJUST SCALES ACCORDINGLYBAR IS ONE INCH ON ORIGINAL DRAWING01"100 River Market Ave St. 301Little Rock, AR 72201501.375.0378 T501.375.6601 FProject:Location:Date:Title:Sheet Number:VERIFY SCALEFASSLER HALL - LITTLE ROCK311 E CAPITOL AVE, LITTLE ROCK, AR 7220201/13/2017SEATING & PLUMBING FIXTURE COUNT PLANT1.03SCALE: 1/8" = 1'-0"1SEATING COUNT PLANEXTERIOR DINNING:6350 SF - 751 SF = 5599 SFIBC 2012 TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWNACE PER OCCUPANTASSEMBLY UNCONCENTRATED:15 SF / Occupant5599 SF / 15 SF/Occupant = 373 Occupants373 Occupants (Exterior) + 226 Occupants (Interior) = 599 Total OccupantsNOTE: 234 OCCUPANTS INSIDE IS DETERMINED, IN PART, BY IBC 2012 SECTION 1004.4"THE OCCUPANT LOAD OF SEATING BOOTHS SHALL BE BASED ON ONE PERSONFOR 24 INCHES OF BOOTH SEAT LENGTH MEASURED AT THE BACKREST OF THESEATING BOOTH"MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESBASED ON TABLE 403.1 OF THE ARKANSAS PLUMBING CODE 2003:599 TOTAL OCCUPANTS / 2 = 299.5 PERSONS PER GENDER299.5 PERSONS / 75 (PERSONS PER WC) = 3.99 WC (ROUNDED UP TO 4 WC)299.5 PERSONS / 200 (PERSONS PER LAV) = 1.5 LAV (ROUNDED UP TO 2 LAV)Revision History# Date Description