Loading...
HomeMy WebLinkAbout1981-08-06 Revised scopeAlterations and Additions to an Existing Educational Building For THE FIRST LUTHERAN CHURCH 714 Rock Street Little Rock, Arkansas Outline materials and methods specifications for the exterior renovation. Revised - 5 August 1981 A. DEMOLITION 1. Complete removal of the existing exterior, deteriorated, sand pressed brick masonry to the foundation line. 2. Remove the existing wood windows, doors, and supporting framing. 3. Remove the existing concrete front entry steps both to the main level and those going to the basement. 4. Remove the existing flag pole and steel fire excape step6 on the front and rear elevations of the building that were installed during the periost that the building was used as an elementary school educational facility. B. RE -CONSTRUCTION 1. Install a cast stone base wainscots matching, approximately, in elevation with the cast stone base wainscote on the neighboring church structure. 2. Re -bricking from the wainscote base to the cornice line with brick that matches the brick on the neighboring church and parsonage buildings. The style and methods will match the existing masonry as reflected in the accompanying drawings. 3. The windows that have been removed, Item A-2 above, will be refininshed and replaced in the locations from which they were removed using the same brick mould and other trim that is found to be sound. Deteriorated wood trim and structural members will be replaced with new material with like profile. Double glazing is tentatively planned to be installed on the inside surface of the windows. Two (2) windows on the second level, south side, are to be deleted and two (2) windows, both levels, on the north side of the building, are to be deleted to accommodate the fellowship hall kitchen installation. 4. A two level entry court, or plaza, will be constructed to facilitate entry to the fellowship hall level. This area is to be partially paved leaving planting areas and the ground level portion is to be delineated from the sidewalk and 1. street activity by a low matching brick wall with openings as required by circulation. 5. The roof has been replaced and will not require additional work except for new plumbing vents, attic exhaust ventilators, range hood exhaust fan, etc., as may be required by interior toilet area revisions, etc. 6. Because of deterioration, beginning to become serious, in marry of the exposed rafter tails, we have elected to box in the roof cornice to match the neighboring church and parsonage. Secondly, to achieve adequate attic ventilation and rather than punching holes in the freeze next to the roof deck, we intend to remove the frieze above the box soffit and install a three inch (3") continuous wire—soreened ventilation strip in the box soffit. 7. Our sincere intention is to construct the building in accordance with drawings submitted. n � 2.