Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0199380sby-c-qt025-30-45-60
1 of 9 ¡ INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. ¡ TEST CRITERIA: PROTOTYPE TESTED NEMA MG1-22 EVALUATION SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY ¡ SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%. ¡ SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. ¡ GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. INCLUDES: • Two Line LCD Tri-Lingual Digital Nexus™ Controller • Isochronous Electronic Governor • Sound Attenuated Enclosure • Closed Coolant Recovery System • Smart Battery Charger • UV/Ozone Resistant Hoses • ±1% Voltage Regulation • Natural Gas or LP Operation* • 2 Year Limited Warranty • UL 2200 Listed * Note: 25-45 kW units are field convertible between natural gas or LP. 60 kW units are built per fuel requirement and are not convertible. Standby Power Rating Model QT025 (Steel - Bisque) - 25 kW 60 Hz Model QT030 (Steel - Bisque) - 30 kW 60 Hz Model QT045 (Steel - Bisque) - 45 kW 60 Hz Model QT060 (Steel - Bisque or Aluminum - Gray) - 60 kW 60 Hz FEATURES GUARDIAN® SERIES Standby Generators Liquid-Cooled Gas Engine Guardian® SeriesGuardian® Series Meets EPA Emission Regulations 25, 30 & 45 kW CA/MA emissions compliant 60 kW not for sale in CA/MA 2 of 9 25 • 30 • 45 • 60 kW application & engineering data GENERATOR SPECIFICATIONS Type Synchronous Rotor Insulation Class H Stator Insulation Class H Telephone Interference Factor (TIF)<50 Alternator Output Leads 1-Phase 4 wire Alternator Output Leads 3-Phase 6 wire Bearings Sealed Ball Coupling Flexible Disc Excitation System Direct VOLTAGE REGULATION Type Electronic Sensing Single Phase Regulation ± 1% GOVERNOR SPECIFICATIONS Type Electronic Frequency Regulation Isochronous Steady State Regulation ± 0.25% ELECTRICAL SYSTEM Battery Charge Alternator 12 Volt 15 Amp-25 & 30 kW 12 Volt 30 Amp-45 & 60 kW Static Battery Charger 2 Amp Recommended Battery Group 26, 525CCA System Voltage 12 Volts GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is rated at 150 °C rise at 25 °C ambient All models fully prototyped tested ENCLOSURE FEATURES Steel weather protective enclosure with aluminum roof (all models) or aluminum weather protective enclosure (available on 60 kW only) Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability. Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Small, compact, attractive Makes for an easy, eye appealing installation. SAE Sound attenuated enclosure ensures quiet operation. ENGINE SPECIFICATIONS: 25 & 30 kW Make Generac Model In-line Cylinders 4 Displacement (Liters)1.5 Bore (in/mm)3.05/77.4 Stroke (in/mm)3.13/79.5 Compression Ratio 11:1 Intake Air System Naturally Aspirated Lifter Type Hydraulic ENGINE SPECIFICATIONS: 45 & 60 kW Make Generac Model In-line Cylinders 4 Displacement (Liters)2.4 Bore (in/mm)3.41/86.5 Stroke (in/mm)3.94/100 Compression Ratio 9.5:1 Intake Air System Naturally Aspirated (45 kW) or Turbocharged/Aftercooled (60 kW) Lifter Type Hydraulic ENGINE LUBRICATION SYSTEM Oil Pump Type Gear Oil Filter Type Full flow spin-on cartridge Crankcase Capacity (qt/l)4/3.8 ENGINE COOLING SYSTEM Type Closed Water Pump Belt driven Fan Speed (rpm) 2484 - 25 & 30 kW 1865 - 45 kW 2100 - 60 kW Fan Diameter (in/mm)17.7/449.6 (25 & 30 kW) or 22/558.8 (45 & 60 kW) Fan Mode Pusher (25 & 30 kW) or Puller (45 & 60 kW) FUEL SYSTEM Fuel Type Natural gas, propane vapor Carburetor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard Operating Fuel Pressure 5-14" water column/9-26 mm HG (All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271)Guardian® Series 3 of 9 25 • 30 • 45 • 60 kW operating data GENERATOR OUTPUT VOLTAGE/kW - 60 Hz kW LPG Amp LPG kW Nat. Gas Amp Nat. Gas CB Size (Both) QT025 120/240 V, 1Ø, 1.0 pf 25 104 25 104 125 120/208 V, 3Ø, 0.8 pf 25 87 25 87 100 120/240 V, 3Ø, 0.8 pf 25 75 25 75 90 QT030 120/240 V, 1Ø, 1.0 pf 30 125 30 125 150 120/208 V, 3Ø, 0.8 pf 30 104 30 104 125 120/240 V, 3Ø, 0.8 pf 30 90 30 90 100 QT045 120/240 V, 1Ø, 1.0 pf 45 188 45 188 200 120/208 V, 3Ø, 0.8 pf 45 156 45 156 175 120/240 V, 3Ø, 0.8 pf 45 135 45 135 150 277/480 V, 3Ø, 0.8 pf 45 68 45 68 80 QT060 120/240 V, 1Ø, 1.0 pf 60 250 60 250 300 120/208 V, 3Ø, 0.8 pf 60 208 60 208 250 120/240 V, 3Ø, 0.8 pf 60 180 60 180 200 277/480 V, 3Ø, 0.8 pf 60 90 60 90 100 SURGE CAPACITY IN AMPS Voltage Dip @ < .4 pf 15%30% QT025 120/240 V, 1Ø 86 209 120/208 V, 3Ø 84 204 120/240 V, 3Ø 73 177 QT030 120/240 V, 1Ø 109 264 120/208 V, 3Ø 109 264 120/240 V, 3Ø 94 229 QT045 120/240 V, 1Ø 61 153 120/208 V, 3Ø 64 160 120/240 V, 3Ø 55 139 277/480 V, 3Ø 29 72 QT060 120/240 V, 1Ø 95 237 120/208 V, 3Ø 100 251 120/240 V, 3Ø 87 218 277/480 V, 3Ø 42 105 ENGINE FUEL CONSUMPTION Natural Gas Propane (ft³/hr)(m³ /hr)(gal/hr)(l/hr) QT025 Exercise cycle 60 1.7 0.7 2.5 25% of rated load 220 6.3 2.9 9.1 50% of rated load 297 8.4 3.3 12.3 75% of rated load 362 10.3 4 15 100% of rated load 430 12.2 4.7 17.8 QT030 Exercise cycle 60 1.7 0.7 2.5 25% of rated load 240 6.8 2.6 10 50% of rated load 320 9.1 3.5 13.3 75% of rated load 400 11.4 4.4 16.6 100% of rated load 492 14 5.4 20.4 QT045 Exercise cycle 65 1.8 0.7 2.6 25% of rated load 210 6 2.3 8.6 50% of rated load 380 10.8 4.2 15.7 75% of rated load 545 15.5 5.9 22.4 100% of rated load 730 20.7 8 30.1 QT060 Exercise cycle 123 3.5 1.34 5.1 25% of rated load 267 7.6 2.7 10.5 50% of rated load 483 13.7 5 19 75% of rated load 672 19.1 7 26.5 100% of rated load 862 24.5 9 33.9 Guardian® SeriesSTANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. Note: Fuel pipe must be sized for full load. For Btu content, multiply gal/hr x 90950 (LP) or ft3/hr x 1000 (NG) For megajoule content, multiply l/hr x 25.35 (LP) or m³/hr x 37.26 (NG) Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes. 4 of 9 25 • 30 • 45 • 60 kW operating data Guardian® SeriesPOWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration ...........................................................................................................3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F Altitude Deration (25, 30 & 45 kW) .....................................................................................1% for every 100 m above 183 m or 3% for every 1000 ft above 600 ft Altitude Deration (60 kW) ................................................................................................ 1% for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft CONTROLLER FEATURES 2-Line Plain Text LCD Display ........................................................................................................................................Simple user interface for ease of operation. Mode Switch: Auto ..............................................................................................................................................Automatic Start on Utility failure. 7 day exerciser Off ...........................................................................................................................Stops unit. Power is removed. Control and charger still operate. Manual .........................................................................................Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10-30 seconds ............................................................................................................................................................Standard Engine Start Sequence .....................................................................................................................Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration) Engine Warm-up .....................................................................................................................................................................................................................5 sec Engine Cool-Down ..................................................................................................................................................................................................................1 min Starter Lock-out ................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger ........................................................................................................................................................................................................Standard Automatic Voltage Regulation with Over and Under Voltage Protection ................................................................................................................................Standard Automatic Low Oil Pressure Shutdown ...............................................................................................................................................................................Standard Overspeed Shutdown ..............................................................................................................................................................................................Standard, 72 Hz High Temperature Shutdown ...............................................................................................................................................................................................Standard Overcrank Protection ..........................................................................................................................................................................................................Standard Safety Fused ......................................................................................................................................................................................................................Standard Failure to Transfer Protection ..............................................................................................................................................................................................Standard Low Battery Protection ........................................................................................................................................................................................................Standard 50 Event Run Log ...............................................................................................................................................................................................................Standard Future Set Capable Exerciser ..............................................................................................................................................................................................Standard Incorrect Wiring Protection .................................................................................................................................................................................................Standard Internal Fault Protection .....................................................................................................................................................................................................Standard Common External Fault Capability ......................................................................................................................................................................................Standard Governor Failure Protection ................................................................................................................................................................................................Standard ENGINE COOLING 25 kW 30 kW 45 kW 60 kW Air flow (inlet air including alternator and combustion air in cfm/cmm)2490/70.5 2490/70.5 2725/77.2 3280/92.9 System coolant capacity (gal/liters)2/7.6 2/7.6 3/11.4 2.5/9.5 Heat rejection to coolant (BTU per hr/MJ per hr)112,000/118.2 135,000/142.4 193,000/203.6 270,000/284.9 Maximum operation air temperature on radiator (°C/°F)60/150 Maximum ambient temperature (°C/°F)50/140 COMBUSTION REQUIREMENTS Flow at rated power (cfm/cmm)62/1.8 72/2 144/4.1 180/5.1 SOUND EMISSIONS Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode*59 59 61 65 Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load*72 73 73 72 *Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. EXHAUST Exhaust flow at rated output (cfm/cmm)203/5.7 237/6.7 420/11.9 494/14 Exhaust temperature at muffler outlet (°C/°F)593/1100 610/1130 593/1100 566/1050 ENGINE PARAMETERS Rated Synchronous rpm 3600 5 of 9 25 • 30 • 45 • 60 kW available accessories Guardian® SeriesModel #Product Description 006175-0 - 25 & 30 kW 005630-0 - 45 & 60 kW Cold Weather Kit If the temperature regularly falls below 32 °F (0 °C), install a cold weather kit to maintain optimal battery temperature. Kit consists of battery warmer with thermostat built into the wrap. 006174-0 - 25 & 30 kW 005616-0 - 45 & 60 kW Extreme Cold Weather Kit Recommended where the temperature regularly falls below 32 °F (0 °C) for extended periods of time. For liquid cooled units only. 005621-0 Auxiliary Transfer Switch Contact Kit The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you may not need. Not compatible with 60 kW models. 005651-0 Base Plug Kit Add base plugs to the base of the generator to keep out debris. 005703-0 - Bisque 005704-0 - Gray Paint Kit* If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. 006176-0 - 25 & 30 kW 006172-0 - 45 kW 006171-0 - 60 kW Scheduled Maintenance Kit The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware necessary to perform complete maintenance on Generac liquid-cooled generators. 005928-0 Wireless Remote Completely wireless and battery powered, Generac's wireless remote monitor provides you with instant status information without ever leaving the house. 005951-0 Advanced Wireless Remote Remotely control generator functions with the advanced model’s LCD display. In addition to remote testing of the generator, set the exercise cycle and maintenance interval reminders. 006199-0 PMM Starter Kit The PMM Starter Kit consists of a 24 VAC, field installed transformer that enables the use of the 24 VAC Power Management Modules (PMMs) and one PMM. The standard controller (without starter kit) can control two HVAC loads with no additional hardware. Not compatible with pre-wired switches. 006186-0 Power Management Module (50 Amps) Power Management Modules are used in conjunction with the Smart Switch to increase its power management capabilities. It gives the Smart Switch additional power management flexibility not found in any other transfer switch. Not compatible with pre-wired switches. Note: PMM Starter Kit required. 006463-1 Mobile Link™ Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or with any smart device. You will even be notified when a change in the generator’s status occurs via e-mail or text message. Note: Harness Adapter Kit required. 006478-0 Harness Adapter Kit The Harness Adapter Kit is required to make liquid-cooled units compatible with Mobile Link™. * Note: Bisque kits are used in conjunction with steel enclosures. Gray kits are used in conjunction with aluminum enclosures (available on 60 kW units only). 6 of 9 25 • 30 • 45 • 60 kW interconnections Guardian® SeriesNEUTRAL BLOCKGROUNDNOTE WIRE ORIENTATIONWARNINGTRANSFERDC COMMONCUSTOMER CONNECTIONS230194+12VDCGROUNDNEUTRAL BLOCKLOAD SHEDMODULE194230N1N2E1E2NOTE: MATCH WIRENUMBERS TOTERMINAL NUMBERS ONN1N2T1/LINENEU17818323194T1CUSTOMER SUPPLIEDNEUTRAL WIRENEUT(C2 & VR2)(C1 & VR1)STANDBYUTILITYN1N2E2E1T1T2019423N2N1T1E1E2T2N1N2T1FEEDER SUPPLY FROM PANEL (REQUIRES 4-WIRE FEEDER) PROTECTED LOADCENTERA TYPICAL RESIDENTIAL/COMMERCIALLIQUID-COOLED GENERATORCONNECTION PANELLIQUID COOLED INSTALLATIONRTS TRANSFER SWITCH0 GROUND15B +12V23 TRANSFERAIR 1AIR 2PRIORITY 1PRIORITY 2PRIORITY 3PRIORITY 4T1NEUTRALCONTACTOR1CONTACTOR2CONTACTOR3CONTACTOR448850-T Note: Use the generator's specific installation manualand wiring diagrams to verify generator wiringconnections, as they may differ slightly from illustration. 7 of 9 25 & 30 kW installation layout Guardian® Series 8 of 9 45 kW installation layout Guardian® Series 9 of 9 60 kW installation layout Guardian® SeriesGenerac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2013 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0199380SBY-C Printed in U.S.A. 11/21/13