Loading...
8184ORDIrJTI CE No. 81L& AN OF.DINANCE AI:LENDING SECTIONS 301, 802, 804, 1809, 3803 and 3804 OF ORDIT-ANCE NO. 7888, COYMONLY K14OVT AS ThE LITTL.�: ROCK BUILDIA'G CODE, AND FOR OTHER URPOSES . BE IT ORDAINED BV THE CITY COUNCIL CP CIT "-' OF LITTLE ROCK, ARKANSAS: SECTION 1. That Section 3019 fourth paragraph. of Ordinance No. 7888 be and the same is hereby amended to read as follows: Any building or portion thereof, including any building or structure in process of erection, if found to be dangerous to per- sons or property, or unsafe for the purpose for which it is being used, or in danger fron, fire due to defects in construction, or dan- gerous for use because of insufficient means of egress in case of fire or which violated the provisions of this Code, or which has be- come damaged by the elements or by fire, provided however, that such damaue by fire exceeds 500 of the value of the building, may be con- demned by the Building* Inspector. The Building Inspector may order portions of the structural frame of a building or structure to be exposed for inspection when in his opinion they are in unsafe con- dition. In any of the aforesaid cases the Building; Inspector shall serve notice in writing on the ovmers, reputed owner or person in charge of such a building or premises, setting forth what must be done to make such building safe. The person receiving such notice shall commence within forty -eight hours thereafter to rake the changes, repairs, or alterations set out in such notice and diligent- ly proceed with such work or demolish the building. No such build- ing shall be occupied or used for any purpose after the Building In- spector serves written notice of its unsafe or dangerous condition until the instructions of the Building Inspector have been complied with. SECTION 2. That Section 802, Page 16, of Ordinance No. 7888 be and the same is hereby amended by adding the following: (c) Public and private school buildings of one story in height having roof construction and decking of incomustible materials, may exceed the allowable floor area required in Paragraph A for Type II buildings by 500. Page 2. SECTION 3. That Section 804, paragraph five, of Ordinance No. 7888 be and the same is hereby amended as follows: Delete the following line: "Corridors shall be at least eight (8) feet w,ide,tt and substitute the following: Corridors shall have a clear width of 8 inches plus .22 inches times the number of people who may be reasonably expected to occupy rooms opening into such corridors, provided that no corridor shall be less than six (6) feet in width. Doors opening into corridors shall not decrease such width by more than one (1) foot when fully open." SECTION 4. That Section 1809, Page 30, of Ordinance No. 7888 be and the sane is hereby amended as follows: Delete Paragraph 3 and substitute the following: Where every part of the structural steel framework of a roof of a Group A and C building is more than eighteen (18) feet and less than twenty -five feet (25) above any floor or balcony, the steel construction shall be protected by a suspended ceiling of no less than one hour fire resistive construction as specified in Chapter 43, and such ceiling shall not be less than six (6) inches from any part of such steel construction. u'dhen every part of the structural steel framework of a roof of a Group A and C building is more than twenty -five (25) feet above any balcony or floor, fireproofing of all members of the roof con- struction may be omitted. When every part of the structural steel framework of the roof of a Group B building is more than twenty (20) feet above any floor or balcony, fireproofing of all members of roof construction may be omitted. SECTION 5. That Section 3803, Page 813 of Ordinance No. 7888 be and the same is hereby amended to read as follows: All buildings in excess of three (3) stories in height, shall be equipped v -ith one or more interior standpipes extending from cellar or basement to the rcof, except that Type III buildings when used as storage Carages, need not be equipped with interior stand- pipes but shall be equipped with a standard automatic sprinkler sys- tem as required by Section 6801, Paragraph 6. Page 3. SECTION 6. That Section 3804, Paragraphs 1 and 2, of Ordinance No. 7888, be and the same i� hereby amended to read as follows: Interior standpipes and fittings shall be constructed of stand- and wrought iron or steel, where the working pressure required is nct in excess of 150 pounds per square inch. Extra strong pipe and extra heavy fittings and valves shall be used where the working pressure required is in excess of 150 pounds per square inch. The size for interior standpipes shall be four (4) inches for buildings not exceeding six (6) stories in height and six (6) inches for build- ings exceeding six (6) stories in height. All interior standpipes shall be equipped with two (2) outlets on each floor having an independent control valve on each outlet. One outlet for Fire Department use shall have an inside diareter two and one -half (22) inches and the National Standard fire hose coupling screw - thread of seven and one -half (72) threads per inch. The other outlet on each floor for first aid use shall have an inside diameter of one and one -half' (12) inches and American Standard taper pipe threads of eleven and one -half (112) threads per inch, and shall have hose attached at all times. SECTION 7. All ordinances and parts of ordinances in conflict herewith are hereby repealed. Unless the provisions of this ordinance are put into effect immediately, the peace, health and safety of the citizens of Little Rock will be adversely affected; therefore., an emergency is hereby declared to exist and this ordinance shall be in full force and effect from and after its passage and approval. PASSED: January 23, 1950. ATTEST: City Clerk APPROVED: Mayor