Z-8696 Map 5PROVIDE 2 NEW HANDICAP ACCESSIBLE — PARKING SPACES WITH SIGNS (SEE DETAILS THIS SHEET) PROVIDE NEW S WIDE CONCRETE SIDEWALK ALONG BACK OF NEW CURB AND GUTTER PROVIDE NEW 10' WIDE CONCRETE SIDEWALK TO TIE NEW PARKING LOT TO EXISTING COVERED ENTRANCE WALK INTO HEADQUARTERS BUILDING CONSTRUCT NEW WROUGHT IRON OR ALUMINUM FENCE ACROSS FRONT OF PROPERTY AND ALONG EXISTING CHAIN LINK FENCE AND ABUT CORNER OF EXISTING BUILDING r ' —'-■. . W__m. \ 1 k I•►�OI�►�OI��OIp�0I��0Ip�0Ip�% •'w�OQ�iG��.►�i�g�.�e�s����Ipj��I����I � 36" DIA SYCAMORE TO BE REMOVED IN ITS ENTIRETY (INCLUDING EXCAVATION AND OFFSITE REMOVAL OF ROOT SYSTEM) AND BACKFILLED WITH SELECT FILL (PER ENGINEER'S APPROVAL) TO 95% OF MODIFIED PROCTOR DENSITY IN 122" MAXIMUM LOOSE LIFTS N s 3(i' OD a, SSMH Lid 334.90 to m NOTE: 30 FEET FROM CENTER OF 40TH STREET RIGHT-OF-WAY TO BE DEDICATED TO CITY OF LITTLE ROCK PRIOR TO COMPLETION OF PARKING LOT CONSTRUCTION FOR ISSUANCE OF CERTIFICATE PROVIDE NEW 30' WIDE ELECTRONIC OF OCCUPANCY. DEDICATION MUST BE PROVIDED TO PUBLIC WORKS, CONTROLLED WROUGHT IRON SLIDING CIVIL ENGINEERING. GATE ACROSS EACH ENTRANCE LANDSCAPED AREA BETWEEN EXISTING SIDEWALK AND NEW CONCRETE CURB AND GUTTER MODIFY EXISTING SIDEWALK WITH HANDICAP ACCESSIBLE RAMPS EACH SIDE OF NEW ENTRANCE DRIVE West 4 tt CONSTRUCT NEW WROUGHT IRON FENCE ACROSS Let FRONT OF PROPERTY AND ALONG EXISTING CHAIN LINK FENCE IVE Comer SEXSEX SeG 14 23 T-I-N. R-13-W 9'-0" MIN 0 iV S 8 '36" n N r� Sfs 2ii c o — -- I $ N 8ti i'49"W 54.60 5.40 *4 Rebar p () o o - 8 T r w � w z M CcI7 10 SPACES (tb 9' _ 0 0 rl) u ZT) o 1^R`1 '^V Q Wv/ N a)d co In � W U a 0 17.50' O O 'PROVIDE NEW CONCRETE ENTRANCE APRONS Q SEE DETAIL THIS SHEET FOR CONSTRUCTION w � U C0 Y 9' WIDE LANDSCAPE BUFFER BETWEEN EXISTING of FENCE ANDEDGEOF NEW PARKING LOT CURB aAND Q EXISTING 30" DIAMETER RED OAK TREE TO REMAIN R_�,�ISLAND PROVIDEINTERNAUCORNERLANDSCAPED (380 S.F.) /— w z LL O M u) CONNECT NEW 6' HI WOOD PRIVACY FENCE TO EXISTING WROUGHT IRON FENCE 94.00' i 1 ' 86'53'36- W i57.38 ebar Power Pole PROVIDE INTERNAL LANDSCAPED ISLAND (685 S.F.) 9' WIDE LANDSCAPE BUFFER BETWEEN EXISTING FENCE AND EDGE OF NEW PARKING LOT CURB AND GUTTER —PROVIDE INTERNAUCORNER LANDSCAPED ISLAND (340 S.F.) 2C 0 G 20 40FT SCA_E: I"= 20' AND TRANSPORTATION DEPARTMENT err (AHTD' STANDARD SPECIFICATIONS \ FOR H�GHWAY CONSTRUCTION, 1996 OR 2003 EDITION o�% - a.a .< 6" THICK CLASS 7 (SB-2 CRUSHED 14,T a eo 'b,o eoo; `d,o -o STONE COMPACTED TO 95% STANDARD v PROCTORDENSITY CONFORMING TO SECTION 303 OF THE (AHTD) STANDARD SPECIFICATIONS FOR HIGHWAY CONST'N SCALE: 1 "=20'-O" NOTES: 6" THICK OF EXISTING SUBGRADE TO 1. 48 TOTAL PARKING SPACES ARE PROVIDED WITH 4 HANDICAP ACCESSIBLE SCARIFIED AND RECOMPACT 90°i5 OF MODIFIED PROCTOR DE DENSISI TY SPACES (ADJACENT TO HEADQUARTERS BUILDING). 2. WOOD PRIVACY FENCE SHALL MEET CITY OF LITTLE ROCK STANDARDS. HMAC ASPHALT SURFACE COURSE 3 ALL SETBACKS SHALL MEET CITY OF LITTLE ROCK REQUIREMENTS 4. ORNAMENTAL WROUGHT IRON FENCE AND GATES SHALL BE SELECTED BY OWNER PRIOR TO PRICING NOT TO SCALE AND INSTALLATION. 5. INSTALLATION OF GATE SHALL INCLUDE COST FOR INSTALLATION OF DIRECT BURIED ELECTRIC LINE FROM EXISTING HEADQUARTERS BUILDING (ON THE WEST SIDE OF THE PROPOSED PARKINGLOT) TO THE NEW GATES ON THE TWO ENTRANCE DRIVES. COST SHALL INCLUDE CONNECTION TO EXISTING ELECTRICAL PANEL IN EXISTING HEADQUARTER BUILDING AND INSTALLATION OF WIRE AND MOTOR OPERATION FOR BOTH SLIDING GATES. SOLAR PANELS WILL BE CONSIDERED FOR SOURCE OF POWER IF ACCEPTABLE PANELS ARE AVAILABLE FOR GATE OPERATION. PAVEMENT DIMENSIC GATES SHALL HAVE MANUAL OVERRIDE FOR MANUAL OPERATION IN CASE OF POWER OUTAGES REFER TO THIS POIN- 6. DAMAGE TO PUBLIC AND PRIVATE PROPERTY DUE TO HAULING OPERATIONS OR OPERATIONS OF CONSTRUCTION RELATED EQUIPMENT FROM A CONSTRUCTION SITE SHALL BE REPAIRED BY THE RESPONSIBLE PARTY PRIOR TO THE 2" OF HMAC SURFACE ISSUANCE OF A CERTIFICATE OF OCCUPANCY. COURSE 7. REPAIR, REPLACE, OR EXTEND EXISTING DAMAGED OR MISSING CURB AND GUTTER, SIDEWALK, RAMPS OR CONCRETE APRONS WITHING THE PUBLIC RIGHT-OF-WAY ADJACENT TO THE SITE. REMOVED ABANDONED DRIVEWAY CUTS AND INSTALL 8" THICK CLASS 7 (SB-2) CURB, GUTTER, AND SIDEWALK. ALL WORK WITHING THE PUBLIC RIGHT -OF -I JAY SHALL CONFORM TO CITY OF LITTLE ROCK CRUSHED STONE COMF STANDARD DETAILS AND ADA GUIDELINES. TO 95% STANDARD PRC 8, CONTACT MELVIN HALL (501.918.5217/501.590.7465) FOR INSPECTIONS OF ANY WORK IN PUBLIC RIGHT-OF-WAY PRIOR TO DENSITY PLACEMENT OF CONCRETE OR ASPHALT OR FOR ON -SITE CLARIFICATION OF REQUIREMENTS PRIOR TO COMMENCING WORK. FAILURE TO DO SO CAN RESULT IN REMOVAL OF ANY IMPROPERLY PLACED CONCRETE OR ASPHALT AT THE EXPENSE OF THE OWNER OR CONTRACTOR x a G NOTES: 1. FENCE SHALL BE WROUGHT IRON OR ALUMINUM (PER OWNER'S CHOICE). 2. FENCE SHALL BE IN ACCORDANCE WITH CURRENT ACCEPTED INDUSTRY STANDARDS FOR MATERIAL TYPE, MATERIAL THICKNESS, COATING, CONNECTIONS, AND ETC. 3. CONTRACTOR SHALL SUBMIT CUT SHEETS (ALONG WITH PRICING) FOR THE SPECIFICS OF ALL OF THE FENCE ELEMENTS. 4. SEE ADDITIONAL NOTES THIS SHEET UNDER PLAN LAYOUT PERTAINING TO FENCING AND GATES. 6" THICK OF 3000 PSI CONCRETE W43 BARS @ 12" ON CENTER. EACH DIRECTION ON 3" HIGH SAND CHAIRS @ 36" ON CENTER, MAX IN ALL DIRECTIONS e e e e e e a •e p�• a p�• o Ow. a Off• p 6" THICK CLASS 7(SB-2) CRUSHED STONE COMPACTED TO 96% STANDARD PROCTORDENSITY CONFORMING TO SECTION 303 OF THE (AHTD) STANDARD SPECIFICATIONS FOR HIGHWAY CONST N t -4• 6" FINISH GRADE R J. D o 0 •O n O N b O Oa 9. OBTAIN PERMITS PRIOR TO DOING ANY STREET CUTS OR CURB CUTS. OBTAIN BARRICADE PERMIT PRIOR TO DOING ANY WORK NOTE: IN THE RIGHT-OF-WAY. CONTACT TRAFFIC ENGINEERING AT 501.379.1817. ALL CURBING TO BE 10. ALL SIGNAGE, PAVEMENT MARKINGS AND PARKING LOT STRIPING SHALL CONFORM TO REQUIREMENTS GIVEN IN MANUAL OF 3000 PSI 28 DAY UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). MUTCD REQUIRES THAT PARKING SPACES BE MARKED IN WHITE. CONTACT TRAFFIC CONCRETE 6" THICK SUBGRADE COMPACTED ENGINEERING (GREG CLAY 501.379.1811) WITH ANY QUESTIONS REGARDING STRIPING. DENSiTYTANDARD PROCTOR Z-0" CONCRETE CURB & GUTTER NOT TO SCALE 11111-111111 1111111 elm 111111=111111 • NOT TO SCALE SEE PLAN FOR WIDTH SIDEWALK OR FIN. GRADE CONCRETE +6"F POST SIGN POST W ACCESSIBILITY SYMBOL & "VAN ACCESSIBLE" SIGN MOUNTED BELOW. (VAN ACCESSIBLE SIGN NOT REQ'D. W/ MIN. 8' STRIPED AISLE) ACCESSIBLE RAMP. SEE DETAIL WHEELSTOP SEE DETAIL (REQ'D. IF WALK WIDTH IS LESS THAN 7'-0") 4" PAINTED STRIPING V-6" O.C. AT 45' IN FRONT OF RAMP (WHITE REFLECTIVE) PAVEMENT MAX. SLOPE 2% IN ALL DIRECTIONS. 4" CONCRETE SLAB/BRUSH FINISH W/6 x 6 - W 1.4 x W1.4 W.W.F. ON 6" THICK SUBGRADE COMPACTED TO 95% MODIFIED PROCTOR MAXIMUM RUNNING SLOPE IS 5%, MAXIMUM CROSS SLOPE IS 2%. -X X X I CONCRETE WALK SECTION NOT TO SCALE 4 LB/FT "U" CHANNEL rrei Venin�nt Lo L3 1i2" — POST SECTION ��— SIGN NUT AND LOCK WASHER 5116" MACHINE SCREW OR BOLT EXISTING GROUND LINE NOT TO SCALE PARKING ONLY VAN ACCESSIBLE MOUNTING PARTIAL ELEVATION EDGE OF WALK (AGAINST LANDSCAPE OR BUILDING TYP.) ✓—FACE OF WALK OR CURB 9.00, 9,00, 9.00, ACCESSIBLE PARKING STALLS �E OF AUT G . •......... ••• %.� Lj PHILLIP LENS• � U 7 ENGINEERING. INC. No. 566 :ice \; �'''�nnuuar EDGE OF RAMP TO BE FLUSH WITH PARKING LOT SURFACE NEW RAMP UP TO SIDEWALK c4 z W 1 m, v 'r N rV U a :.J C4 F r? U G c N W G. •' v; W � 0. Q y� N U Q W F' VJ D z p J W U) z O(DW Lu Y ``0 v l � Z U) Q QY� Y Z pro c� � t! / co co uj LL Ow� f— z J J W 0 Lu W� CL 0 O 0 J 0- REVISIONS: DATE: MAY 2014 SHEET: c 1.1