Loading...
Z-8646-B Map 2MATCH EXISTING CURB AND GUTTER LLJ O N � DRIVEWAY NOT Z o TO EXTEND PAST C) PROJECTED SIDE =1 I PROPERTY LINE iE SIGN PROPOSED CONC. DRIVEWAY 90.01 lnu` I►iinn►u►l►n►Ir,inu i�lllll�!4, ' w--- PV WATERLINE Il ---------;�=ch. EXISTING SIGN C. 5' SETBACK BLOCK 3 I, �� 11 PARK ADDITION ',II 11 LOT 8 % LOT 9 l� Ili EXISTING BUILDING PROPS ED CROSS I 'd ACCaSS EASEMENT 5' SETBACK 5 SETBAC U Y Q U Q I U m LOT ILO / 2,950 , EXISTING CURB-:CURB-:J I AND GUTTER 20' RADIAL DEDICA 1 I i I I I I LOT 10 I 1 I I I 1 1\ ,I l I I I i 1 T EXISTING BUILDING LOT 11 EXISTING TREES TO REMAIN AND PRESE DURING CONSTRUCT 12'HACKBERRY LOT 2A a 2,950 S.F. i MATCH I CURB AND EXISTING 180 WILLOW OAK TO BE REMOVED 90.0' 5' SETBACK LOT 12 5 SETBACK 5 __ __ { �I _ — --- ----- ___ TBA 16 HACKBERRt . .. , z we scow OAK CK 5 SETBACK_ �' � BPS. +r--- _ .12. •• • _ _ — 4 HACKBERRY— �� 1\ // " - --' _--- r— - -- ---= -.. _ --------------- -- -- -- - ------ ---- CID C. _ - MATCH EXISTING CURB AND GUTTER EXISTING TREES TO BE PROPOSED MATCH EXISTING REMAIN AND PRESERVED — CONC. DRIVEWAY I CURB AND GUTTER DURING CONSTRUCTION MATCH EASPXIIS ANT WEST 13TH STREET (ASPHALT/GONG. - 60' ROW) --�r--OHE--1•---OHE — { —try OHE—_+--OHE— EXISTING BUILDING EXISTING PARKING LOT t� SITE NOTES 1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA STANDARDS. 2. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS. 3. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. 4. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT SPECIFICATIONS. 5. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE RESTRICTIVE. 6. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED PRIOR TO CONSTRUCTION START. 7. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE, AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT. 8. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS, DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND VEHICULAR TRAFFIC TO AND FROM THE SITE. 20' LEGEND (EXISTING) GRAPHIC SCALE IN FEET SYMBOLS LINEWORK 20' 0 20'--- ----------------- 0 FOUND IRON PIN EASEMENT E LIGHT POLE POWER POLE CURB m TELEPHONE PEDESTAL — — TV PEDESTAL INTERMEDIATE CONTOUR O MANHOLE INDEX CONTOUR ° SANITARY SEWER CLEANOUT --_—--___aa---_-5s 0 GAS METER SANITARY SEWER LINE DRIVEWAY NOT TO >< GAS VALVE GAS LINE—G-----c — EXTEND PAST -- ------ —------ =---1 STORM SEWER PIPE PROJECTED SIDE c DOWN GUY WATER LINE (SPECIFY SIZE & TYPE) PROPERTY LINE D4 WATER VALVE — — — — —UGi— —— —UCT FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE PROPOSED AIR RELEASE VALVE —ccE— 0 --- 0 —c,z— f CONC. DRIVEWAY UNDERGROUND ELECTRIC MATCH EXISTING FIRE DEPARTMENT CONNECTION —OHE--f--OXE— —OHE— f ASPHALT O WATER METER OVERHEAD ELECTRIC F— ® SPRINKLER HEAD ----- =rv-----UGrv-----LLJ c=rv— LLJ m ELECTRIC PEDESTAL UNDERGROUND TELEVISION -----Unrv-----anry----OnN— N ; — — OVERHEAD TELEVISION !� I! GRATED INLET ---- CHAIN LINK FENCE 11 DROP INLET WOOD FENCE — BARBED WIRE FENCE ,E� • TREE r�ro FIBER OPTIC ;TING ; TREE TO BE REMOVED RIGHT OF WAY — — — GUTTER ROAD CENTERLINE x — PROPOS COCN. I1: I DEDICkTION ENGINEER'S NOTICE TO CONTRACTOR THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK. SAFETY NOTICE TO CONTRACTOR IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE CONSTRUCTION SITE. OWNERSHIP OF DOCUMENTS THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON, TULL & ASSOCIATES, INC., AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL & ASSOCIATES, INC. NOTIFICATION OF LIMITED SERVICES GRAFTON. TULL & ASSOCIATES, INC., (CIA) HAS NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A PORTION OF THE WORK INDICATED ON THESE DRAWINGS. THEREFORE, THE CIA HEREBY NOTIFIES ALL PARTIES INVOLVED THAT THE CIA ASSUMES NO RESPONSIBILITY FOR THE INTERPRETATION, COORDINATION AND ADMINISTRATION Of THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THE EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL RELATED TRADES OR CONSTRUCTION SEQUENCES, OR OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC— IFICALLY REQUIRED IN THE CTA's SERVICES AGREEMENT WITH THE OWNER. coo LEGEND (PROPOSED) SYMBOLS LINEWORK • SET IRON PIN --------------------------- EASEMENT LIGHT POLE 111111, POWER POLE CURB ■ TELEPHONE PEDESTAL 1206 is TV PEDESTAL INTERMEDIATE CONTOUR Q MANHOLE 1205 INDEX CONTOUR 0 SANITARY SEWER CLEANOUT s --9AaJ&L —= SANITARY SEWER LINE N GAS VALVE , O STORM SEWER PIPE GAS LINE z-X STRUCTURE NUMBER ■ WATER LINE ►t WATER VALVE _ FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE _ 161 AIR RELEASE VALVE y ._, FIRE DEPARTMENT CONNECTION UNDERGROUND ELECTRIC • WATER METER M OVERHEAD ELECTRIC B BACK FLOW PREVENTER G REDUCER eu W FIBER OPTIC • PLUG VALVE _ IN GRATEDINLET UNDERGROUND TELEVISION INII OVERHEAD TELEVISION DROP INLET CHAIN LINK FENCE WOOD FENCE Y X R Y X N N N BARBED WIRE FENCE BUILDING SET BACK RIGHT OF WAY PROPERTY LINE ' ROAD CENTERLINE /yip resew a,e . 6/-7/,s apt . 7/9/t 5 c9(�-a 10825 Financial Center Parkway, Suite 300 Little Rock, Arkansas 12211 Crafton Tull 0 engineering I surveying 501.664.3245 t 501.664.6704 f wvvw.craftontull.com CERTIFICATE OF AUTHORIZATION: " e JP� ,,,0F,'AUry0"" a� �z CRAFTON, TULL & _,_ ASSOCIATES, INC. ry- No. 109 s =y o J 2' gP'tAN5A5 EI:Ot�EER VANN ADDITION (A REPLAT OF THE SOUTH 501 OF LOTS 718,9110111 & 12 OF BLOCK 3, PARK ADDITION TO THE CITY OF LITTLE ROCK, PULASKI COUNTY, ARKANSAS) 2284 WEST 13th STREET LITTLE ROCK, AR Key Plan No. Description Data This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Crafton, Tull & Associates, Inc., and is not to be used, in whole or in part, for any other project, without the written authorization of Crafton, Tull & Associates, Inc. �S.1aUCTION PROJECT NO: 1'18022-00 OO ISSUE DATE: 04/06/11 ko'_ THIS CONTACT: &PETERSON DOCUMENT IS CHECKED BY: = PRELIMINARY IN NATURE AND IS NOT PRELIMINARY m AFINAL,SIGNED o PLANS z, AND SEALED DOCUMENT O 2011 Crafton, Tull & Associates, Inc. "° NOliana>s� LAYOUT PLAN RECETV MAY ,, 2 2 201T BY:�_