Z-8646-B Map 2MATCH EXISTING
CURB AND GUTTER
LLJ
O
N �
DRIVEWAY NOT Z o
TO EXTEND PAST C)
PROJECTED SIDE =1 I
PROPERTY LINE
iE
SIGN
PROPOSED
CONC. DRIVEWAY
90.01
lnu` I►iinn►u►l►n►Ir,inu
i�lllll�!4, '
w---
PV WATERLINE Il
---------;�=ch.
EXISTING SIGN
C.
5' SETBACK
BLOCK 3 I, �� 11
PARK ADDITION ',II 11
LOT 8 % LOT 9
l�
Ili
EXISTING
BUILDING
PROPS ED CROSS I 'd
ACCaSS EASEMENT
5' SETBACK 5 SETBAC
U Y
Q U
Q
I U m LOT
ILO / 2,950 ,
EXISTING CURB-:CURB-:J I
AND GUTTER
20' RADIAL DEDICA
1
I
i
I
I
I
I
LOT 10
I
1
I
I
I
1
1\
,I
l I
I
I
i
1
T EXISTING
BUILDING
LOT 11
EXISTING TREES TO
REMAIN AND PRESE
DURING CONSTRUCT
12'HACKBERRY
LOT 2A a
2,950 S.F.
i
MATCH I
CURB AND
EXISTING 180
WILLOW OAK
TO BE REMOVED
90.0'
5' SETBACK
LOT 12
5 SETBACK 5
__ __
{ �I
_
— --- -----
___
TBA 16 HACKBERRt
. .. , z we scow OAK CK
5 SETBACK_
�' �
BPS.
+r---
_ .12. •• • _ _ — 4 HACKBERRY— ��
1\ //
" - --' _--- r— -
-- ---= -.. _
--------------- -- -- -- -
------ ----
CID C.
_ -
MATCH EXISTING
CURB AND GUTTER
EXISTING TREES TO BE
PROPOSED
MATCH EXISTING
REMAIN AND PRESERVED
— CONC. DRIVEWAY
I CURB AND GUTTER
DURING CONSTRUCTION
MATCH EASPXIIS ANT
WEST 13TH STREET
(ASPHALT/GONG. - 60'
ROW)
--�r--OHE--1•---OHE — { —try
OHE—_+--OHE—
EXISTING
BUILDING
EXISTING
PARKING LOT
t� SITE NOTES
1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL
CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA
STANDARDS.
2. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT
LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING,
SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING
DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS.
3. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHERWISE
NOTED.
4. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT
SPECIFICATIONS.
5. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO
ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE
RESTRICTIVE.
6. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED
PRIOR TO CONSTRUCTION START.
7. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE,
AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT.
8. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS,
DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY
AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND
VEHICULAR TRAFFIC TO AND FROM THE SITE.
20'
LEGEND (EXISTING)
GRAPHIC SCALE IN FEET SYMBOLS LINEWORK
20' 0 20'--- -----------------
0 FOUND IRON PIN EASEMENT
E LIGHT POLE
POWER POLE CURB
m TELEPHONE PEDESTAL — —
TV PEDESTAL INTERMEDIATE CONTOUR
O MANHOLE
INDEX CONTOUR
° SANITARY SEWER CLEANOUT --_—--___aa---_-5s
0 GAS METER SANITARY SEWER LINE
DRIVEWAY NOT TO >< GAS VALVE GAS LINE—G-----c —
EXTEND PAST -- ------ —------ =---1 STORM SEWER PIPE
PROJECTED SIDE c DOWN GUY WATER LINE (SPECIFY SIZE & TYPE)
PROPERTY LINE D4 WATER VALVE — — — — —UGi— ——
—UCT
FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE
PROPOSED AIR RELEASE VALVE —ccE— 0 --- 0 —c,z— f
CONC. DRIVEWAY UNDERGROUND ELECTRIC
MATCH EXISTING FIRE DEPARTMENT CONNECTION
—OHE--f--OXE— —OHE— f
ASPHALT O WATER METER OVERHEAD ELECTRIC
F— ® SPRINKLER HEAD ----- =rv-----UGrv-----LLJ
c=rv—
LLJ m ELECTRIC PEDESTAL UNDERGROUND TELEVISION
-----Unrv-----anry----OnN—
N ; — — OVERHEAD TELEVISION
!� I! GRATED INLET
---- CHAIN LINK FENCE
11 DROP INLET WOOD FENCE
—
BARBED WIRE FENCE
,E� • TREE r�ro
FIBER OPTIC
;TING ; TREE TO BE REMOVED RIGHT OF WAY — — —
GUTTER ROAD CENTERLINE
x
— PROPOS
COCN. I1:
I
DEDICkTION
ENGINEER'S NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND
UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS
ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS.
TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING
UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE
ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF
THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND
ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE
DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE
FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION
OF THEIR WORK.
SAFETY NOTICE TO CONTRACTOR
IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION
PRACTICES, THE CONTRACTOR WILL BE SOLELY AND
COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB
SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY
DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT
WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS.
THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION
REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT
INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE
CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE
CONSTRUCTION SITE.
OWNERSHIP OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS AN INSTRUMENT OF
PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON,
TULL & ASSOCIATES, INC., AND IS NOT TO BE
USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH
OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL
& ASSOCIATES, INC.
NOTIFICATION OF LIMITED SERVICES
GRAFTON. TULL & ASSOCIATES, INC., (CIA) HAS
NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION
ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A
PORTION OF THE WORK INDICATED ON THESE DRAWINGS.
THEREFORE, THE CIA HEREBY NOTIFIES ALL PARTIES
INVOLVED THAT THE CIA ASSUMES NO RESPONSIBILITY FOR
THE INTERPRETATION, COORDINATION AND ADMINISTRATION Of
THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THE
EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL
RELATED TRADES OR CONSTRUCTION SEQUENCES, OR
OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC—
IFICALLY REQUIRED IN THE CTA's SERVICES AGREEMENT WITH
THE OWNER.
coo LEGEND (PROPOSED)
SYMBOLS
LINEWORK
•
SET IRON PIN
---------------------------
EASEMENT
LIGHT POLE
111111,
POWER POLE
CURB
■
TELEPHONE PEDESTAL
1206
is
TV PEDESTAL
INTERMEDIATE CONTOUR
Q
MANHOLE
1205
INDEX CONTOUR
0
SANITARY SEWER CLEANOUT
s
--9AaJ&L —=
SANITARY SEWER LINE
N
GAS VALVE
,
O
STORM SEWER PIPE
GAS LINE
z-X
STRUCTURE NUMBER
■
WATER LINE
►t
WATER VALVE
_
FIRE HYDRANT ASSEMBLY
UNDERGROUND TELEPHONE _
161
AIR RELEASE VALVE
y
._,
FIRE DEPARTMENT CONNECTION
UNDERGROUND ELECTRIC
•
WATER METER
M
OVERHEAD ELECTRIC
B
BACK FLOW PREVENTER
G
REDUCER
eu W
FIBER OPTIC
•
PLUG VALVE
_
IN
GRATEDINLET
UNDERGROUND TELEVISION
INII
OVERHEAD TELEVISION
DROP INLET
CHAIN LINK FENCE
WOOD FENCE
Y X R Y X N N N
BARBED WIRE FENCE
BUILDING SET BACK
RIGHT OF WAY
PROPERTY LINE '
ROAD CENTERLINE
/yip resew
a,e . 6/-7/,s
apt . 7/9/t 5
c9(�-a
10825 Financial Center Parkway, Suite 300
Little Rock, Arkansas 12211
Crafton Tull
0 engineering I surveying
501.664.3245 t 501.664.6704 f
wvvw.craftontull.com
CERTIFICATE OF AUTHORIZATION: " e JP� ,,,0F,'AUry0""
a� �z
CRAFTON, TULL &
_,_ ASSOCIATES, INC.
ry- No. 109 s
=y o
J 2'
gP'tAN5A5 EI:Ot�EER
VANN ADDITION
(A REPLAT OF THE SOUTH 501 OF
LOTS 718,9110111 & 12 OF BLOCK
3, PARK ADDITION TO THE CITY
OF LITTLE ROCK, PULASKI
COUNTY, ARKANSAS)
2284 WEST 13th STREET
LITTLE ROCK, AR
Key Plan
No. Description Data
This document, and the ideas and designs incorporated herein,
as an instrument of professional service, is the property of
Crafton, Tull & Associates, Inc., and is not to be used, in whole
or in part, for any other project, without the written
authorization of Crafton, Tull & Associates, Inc.
�S.1aUCTION
PROJECT NO: 1'18022-00 OO
ISSUE DATE: 04/06/11 ko'_ THIS
CONTACT: &PETERSON DOCUMENT IS
CHECKED BY: = PRELIMINARY IN
NATURE AND IS NOT
PRELIMINARY m AFINAL,SIGNED o
PLANS z, AND SEALED
DOCUMENT
O 2011 Crafton, Tull & Associates, Inc.
"° NOliana>s�
LAYOUT PLAN
RECETV
MAY
,, 2 2 201T
BY:�_