Z-8646-B Map 1MATCH EXISTING
CURB AND GUTTER
LAJ
O
DRIVEWAY NOT z
o
TO EXTEND PAST ON1
Lnj
PROJECTED SIDE
II
PROPERTY LINE 1-5+;-[
�WWATERLINE 1Xf
1------------
1)
EXISTING- SIGN
— CIV
BLOCK 3 T��
I PARK ADDITION j,11jI
i
LOT 7 LOT 8 % / LOT 9 I I LOT 10 1
I �
I,I9
? I
j II EXISTING
BUILDING
LOT 11
1 / EXISTING
BUILDING
/ EXISTING TREES TO
PRO ED CROSS
- ACCPSS EASEMENT I REMAIN AND PRESS
DURING CONSTRUCT
PROPOSED
CONC. DRIVEWAY
190.0'_
5' SIFT
LOT 1
4,380 S.F.
5' SETBACK
LEXISTING CURB
AND GUTTER
' RADIAL DEDICATION,
'('----OHS ---R----OHE--4
t� SITE NOTES
1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL
CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA
STANDARDS.
2. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT
LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING,
SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING
DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS.
3. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHERWISE
NOTED.
4. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT
SPECIFICATIONS.
5. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO
ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE
RESTRICTIVE.
6. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED
PRIOR TO CONSTRUCTION START.
7. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE,
AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT.
8. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS,
DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY
AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND
VEHICULAR TRAFFIC TO AND FROM THE SITE.
i�
0
5
U y
m U
I N I �n LOT
n 2,950
,� Tn
5'
LO
o",
15572011
_ MATCH EXISTING
CURB AND GUTTER
PROPOSED
- CONIC. DRIVEWAY
MATCH EXISTING
ASPHALT
EXISTING
PARKING LOT
I
I
I
LOT 2A
2,950 S.F. P
v
Tr
12'WILLOW OAK 5' SETBACK 16'HACKBERR'i
12'HACKBERRY
LO
LEGEND (EXISTING)
GRAPHIC SCALE IN FEET
SYMBOLS LINEWORK
2' G 20'
o FOUND IRON PIN EASEMENT
LIGHT POLE__________________________________________________________
POWER POLE CURB
Cl TELEPHONE PEDESTAL - - - - ---1206- - - -
IS TV PEDESTAL INTERMEDIATE CONTOUR
O MANHOLE --------------_1205--,
INDEX CONTOUR
a SANITARY SEWER CLEANOUT ___—n----- --_--u
IL GAS METER SANITARY SEWER LINE
DRIVEWAY NOT TO Da GAS VALVE GAS LINE—0-----0-----0
I MATCH E ISTING I� EXTEND PAST
CURB AND UTTER PROJECTED SIDE
PROPERTY LINE
E EXISTING 18" II
WILLOW OAK
TO BE REMOVED PROPOSED
I' /EXISTING
5' 90.G' . � SETBACK :• '• ' - IB;WILI_ OAK.•: , ..•. • .
II
r
',
'[
IIIII4
may- EXISTING TREES TO BE
MATCH EXISTING REMAIN AND PRESERVED
CURB AND GUTTER - DURING CONSTRUCTION
WEST 13TH STREET
(ASPHALT/CONC, - 60' ROW)
r vWT^ r,in
GUTTER
PROPO
COCN. IDEWAU
I
20' RADI�L DEDIC TION
I
I
ENGINEER'S NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND
UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS
ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS.
TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING
UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE
ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF
THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND
ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE
DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE
FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION
OF THEIR WORK.
SAFETY NOTICE TO CONTRACTOR
IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION
PRACTICES, THE CONTRACTOR WILL BE SOLELY AND
COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB
SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY
DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT
WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS.
THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION
REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT
INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE
CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE
CONSTRUCTION SITE.
OWNERSHIP OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS AN INSTRUMENT OF
PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON,
TULL & ASSOCIATES, INC., AND IS NOT TO BE
USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH
OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL
& ASSOCIATES, INC.
NOTIFICATION OF LIMITED SERVICES
CRAFTON, TULL & ASSOCIATES, INC., (CTA) HAS
NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION
ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A
PORTION OF THE WORK INDICATED ON THESE DRAWINGS.
THEREFORE, THE CTA HEREBY NOTIFIES ALL PARTIES
INVOLVED THAT THE CTA ASSUMES NO RESPONSIBILITY FOR
THE INTERPRETATION, COORDINATION AND ADMINISTRATION 0
THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THE
EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL
RELATED TRADES OR CONSTRUCTION SEQUENCES, OR
OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC-
IFICALLY REQUIRED IN THE CTA's SERVICES AGREEMENT WITH
THE OWNER.
STORM SEWER PIPE
DOWN GUY
WATER LINE (SPECIFY SIZE & TYPE)
D4
WATER VALVE
-----OOr------�Or
FIRE HYDRANT ASSEMBLY
UNDERGROUND TELEPHONE
C8�
AIR RELEASE VALVE
—"E— ll—um—
—
UNDERGROUND ELECTRIC
.�1
FIRE DEPARTMENT CONNECTION
— — f —ONE— f —OHE—
O
WATER METER
OVERHEAD ELECTRIC
®
SPRINKLER HEAD
-----OOT,--------- -----ON—
m
ELECTRIC PEDESTAL
UNDERGROUND TELEVISION
-----aerv-------- ----a rv—
OVERHEAD TELEVISION
€. �ZJ
GRATED INLET
---
DROP INLET
CHAIN LINK FENCE
WOOD FENCE
FA
BARBED WIRE FENCE
TREE
rerO
FIBER OPTIC
RIGHT OF WAY
\\*1
TREE TO BE REMOVED
I*1
ROAD CENTERLINE
coo LEGEND (PROPOSED)
SYMBOLS
LINEWORK
•
SET IRON PIN
---------------------------
EASEMENT
LIGHT POLE
POWER POLE
CURB
■
TELEPHONE PEDESTAL
1206
19
TV PEDESTAL
INTERMEDIATE CONTOUR
Q•
MANHOLE
1205
INDEX CONTOUR
0
SANITARY SEWER CLEANOUT
_ A
GAS METER
SANITARY SEWER LINE
-
GAS VALVE - —
,
0
STORM SEWER PIPE
GAS LINE
X-X
STRUCTURE NUMBER
-
WATER LINE
►N
WATER VALVE
FIRE HYDRANT ASSEMBLY
UNDERGROUND TELEPHONE
MA
AIR RELEASE VALVE
FIRE DEPARTMENT CONNECTION
UNDERGROUND ELECTRIC
•
WATER METER
OVERHEAD ELECTRIC
®
BACK FLOW PREVENTER
®
REDUCER
FIBER OPTIC
•
PLUG VALVE
_
UNDERGROUND TELEVISION
GRATED INLET
01 „N
OVERHEAD TELEVISION
DROP INLET
CHAIN LINK FENCE o
WOOD FENCE
,
BARBED WIRE FENCE
v DIG1 4
J O � gtis
O� ILJJ sill
Lr l Z
m
BUILDING SET BACK
RIGHT OF WAY
PROPERTY LINE
ROAD CENTERLINE
10825 Financial Center Parkway, Suite 300
Little Rock, Arkansas 12211
Crafton Tull
0 engineering I Surveying
501.664.3245 t 501.664.6704 f
www.craftontull.com
CERTIFICATE OF AUTHORIZATION:
F O"
CRAFTON, TULL &
ASSOCIATES, INC. D'=
ry- No. 109 ~_
"0 ZO>
NSASnI
VANN ADDITION
(A REPLAT OF THE SOUTH 501 OF
LOTS 7,8,9,1Oil 1 & 12 OF BLOCK
3, PARK ADDITION TO THE CITY
OF LITTLE ROCK, PULASKI
COUNTY, ARKANSAS)
2284 WEST 13th STREET
LITTLE ROCK, AR
Key Plan
No. Description Data
This document, and the ideas and designs incorporated herein,
as an instrument of professional service, is the property of
Crafton, Tull & Associates, Inc., and is not to be used, in whole
or in part, for any other project, without the written
authorization of Crafton, Tull & Associates, Inc.
St RUCTION
, e PROJECT NO: 118022-00 GO
ISSUE DATE: 01/06/11 �0 THIS
CONTACT: B.PETERSON DOCUMENT IS rn
CHECKED BY: 2 PRELIMINARY IN
NATURE AND IS NOT
PRELIMINARY w AFINAL,SIGNED o
PLANS %% AND SEALED
DOCUMENT
O 2011 Crafton, Tull & Associates, Inc. �6' p0
NOI lof1a15�
LAYOUT PLAN
RECEIVED
MAY 2 2 2011
BY: