Loading...
Z-8646-B Map 1MATCH EXISTING CURB AND GUTTER LAJ O DRIVEWAY NOT z o TO EXTEND PAST ON1 Lnj PROJECTED SIDE II PROPERTY LINE 1-5+;-[ �WWATERLINE 1Xf 1------------ 1) EXISTING- SIGN — CIV BLOCK 3 T�� I PARK ADDITION j,11jI i LOT 7 LOT 8 % / LOT 9 I I LOT 10 1 I � I,I9 ? I j II EXISTING BUILDING LOT 11 1 / EXISTING BUILDING / EXISTING TREES TO PRO ED CROSS - ACCPSS EASEMENT I REMAIN AND PRESS DURING CONSTRUCT PROPOSED CONC. DRIVEWAY 190.0'_ 5' SIFT LOT 1 4,380 S.F. 5' SETBACK LEXISTING CURB AND GUTTER ' RADIAL DEDICATION, '('----OHS ---R----OHE--4 t� SITE NOTES 1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA STANDARDS. 2. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS. 3. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. 4. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT SPECIFICATIONS. 5. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE RESTRICTIVE. 6. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED PRIOR TO CONSTRUCTION START. 7. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE, AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT. 8. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS, DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND VEHICULAR TRAFFIC TO AND FROM THE SITE. i� 0 5 U y m U I N I �n LOT n 2,950 ,� Tn 5' LO o", 15572011 _ MATCH EXISTING CURB AND GUTTER PROPOSED - CONIC. DRIVEWAY MATCH EXISTING ASPHALT EXISTING PARKING LOT I I I LOT 2A 2,950 S.F. P v Tr 12'WILLOW OAK 5' SETBACK 16'HACKBERR'i 12'HACKBERRY LO LEGEND (EXISTING) GRAPHIC SCALE IN FEET SYMBOLS LINEWORK 2' G 20' o FOUND IRON PIN EASEMENT LIGHT POLE__________________________________________________________ POWER POLE CURB Cl TELEPHONE PEDESTAL - - - - ---1206- - - - IS TV PEDESTAL INTERMEDIATE CONTOUR O MANHOLE --------------_1205--, INDEX CONTOUR a SANITARY SEWER CLEANOUT ___—n----- --_--u IL GAS METER SANITARY SEWER LINE DRIVEWAY NOT TO Da GAS VALVE GAS LINE—0-----0-----0 I MATCH E ISTING I� EXTEND PAST CURB AND UTTER PROJECTED SIDE PROPERTY LINE E EXISTING 18" II WILLOW OAK TO BE REMOVED PROPOSED I' /EXISTING 5' 90.G' . � SETBACK :• '• ' - IB;WILI_ OAK.•: , ..•. • . II r ', '[ IIIII4 may- EXISTING TREES TO BE MATCH EXISTING REMAIN AND PRESERVED CURB AND GUTTER - DURING CONSTRUCTION WEST 13TH STREET (ASPHALT/CONC, - 60' ROW) r vWT^ r,in GUTTER PROPO COCN. IDEWAU I 20' RADI�L DEDIC TION I I ENGINEER'S NOTICE TO CONTRACTOR THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK. SAFETY NOTICE TO CONTRACTOR IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE CONSTRUCTION SITE. OWNERSHIP OF DOCUMENTS THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON, TULL & ASSOCIATES, INC., AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL & ASSOCIATES, INC. NOTIFICATION OF LIMITED SERVICES CRAFTON, TULL & ASSOCIATES, INC., (CTA) HAS NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A PORTION OF THE WORK INDICATED ON THESE DRAWINGS. THEREFORE, THE CTA HEREBY NOTIFIES ALL PARTIES INVOLVED THAT THE CTA ASSUMES NO RESPONSIBILITY FOR THE INTERPRETATION, COORDINATION AND ADMINISTRATION 0 THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THE EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL RELATED TRADES OR CONSTRUCTION SEQUENCES, OR OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC- IFICALLY REQUIRED IN THE CTA's SERVICES AGREEMENT WITH THE OWNER. STORM SEWER PIPE DOWN GUY WATER LINE (SPECIFY SIZE & TYPE) D4 WATER VALVE -----OOr------�Or FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE C8� AIR RELEASE VALVE —"E— ll—um— — UNDERGROUND ELECTRIC .�1 FIRE DEPARTMENT CONNECTION — — f —ONE— f —OHE— O WATER METER OVERHEAD ELECTRIC ® SPRINKLER HEAD -----OOT,--------- -----ON— m ELECTRIC PEDESTAL UNDERGROUND TELEVISION -----aerv-------- ----a rv— OVERHEAD TELEVISION €. �ZJ GRATED INLET --- DROP INLET CHAIN LINK FENCE WOOD FENCE FA BARBED WIRE FENCE TREE rerO FIBER OPTIC RIGHT OF WAY \\*1 TREE TO BE REMOVED I*1 ROAD CENTERLINE coo LEGEND (PROPOSED) SYMBOLS LINEWORK • SET IRON PIN --------------------------- EASEMENT LIGHT POLE POWER POLE CURB ■ TELEPHONE PEDESTAL 1206 19 TV PEDESTAL INTERMEDIATE CONTOUR Q• MANHOLE 1205 INDEX CONTOUR 0 SANITARY SEWER CLEANOUT _ A GAS METER SANITARY SEWER LINE - GAS VALVE - — , 0 STORM SEWER PIPE GAS LINE X-X STRUCTURE NUMBER - WATER LINE ►N WATER VALVE FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE MA AIR RELEASE VALVE FIRE DEPARTMENT CONNECTION UNDERGROUND ELECTRIC • WATER METER OVERHEAD ELECTRIC ® BACK FLOW PREVENTER ® REDUCER FIBER OPTIC • PLUG VALVE _ UNDERGROUND TELEVISION GRATED INLET 01 „N OVERHEAD TELEVISION DROP INLET CHAIN LINK FENCE o WOOD FENCE , BARBED WIRE FENCE v DIG1 4 J O � gtis O� ILJJ sill Lr l Z m BUILDING SET BACK RIGHT OF WAY PROPERTY LINE ROAD CENTERLINE 10825 Financial Center Parkway, Suite 300 Little Rock, Arkansas 12211 Crafton Tull 0 engineering I Surveying 501.664.3245 t 501.664.6704 f www.craftontull.com CERTIFICATE OF AUTHORIZATION: F O" CRAFTON, TULL & ASSOCIATES, INC. D'= ry- No. 109 ~_ "0 ZO> NSASnI VANN ADDITION (A REPLAT OF THE SOUTH 501 OF LOTS 7,8,9,1Oil 1 & 12 OF BLOCK 3, PARK ADDITION TO THE CITY OF LITTLE ROCK, PULASKI COUNTY, ARKANSAS) 2284 WEST 13th STREET LITTLE ROCK, AR Key Plan No. Description Data This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Crafton, Tull & Associates, Inc., and is not to be used, in whole or in part, for any other project, without the written authorization of Crafton, Tull & Associates, Inc. St RUCTION , e PROJECT NO: 118022-00 GO ISSUE DATE: 01/06/11 �0 THIS CONTACT: B.PETERSON DOCUMENT IS rn CHECKED BY: 2 PRELIMINARY IN NATURE AND IS NOT PRELIMINARY w AFINAL,SIGNED o PLANS %% AND SEALED DOCUMENT O 2011 Crafton, Tull & Associates, Inc. �6' p0 NOI lof1a15� LAYOUT PLAN RECEIVED MAY 2 2 2011 BY: