Z-5675-C Map 7(3) Pistacia chinensis
1 (3) Quercus phellos
`rte +eWL Nf"�M -;' ^k-•�4 W '� i �
is }
'll
(3) Pistacia chinensis
r L
�S•, I
i
NOTIFICATION OF LIMITED SERVICES
CRAFTON, TULL, SPARKS & ASSOCIATES, INC., (CTSA) HAS
NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION
ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A
PORTION OF THE WORK INDICATED ON THESE DRAWINGS.
THEREFORE, THE CTSA HEREBY NOTIFIES ALL PARTIES
INVOLVED THAT THE CTSA ASSUMES NO RESPONSIBILITY FOR
THE INTERPRETATION, COORDINATION AND ADMINISTRATION O
THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THE
EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL
RELATED TRADES OR CONSTRUCTION SEQUENCES, OR
OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC—
IFICALLY REQUIRED IN THE CTSA's SERVICES AGREEMENT WITF
THE OWNER.
ENGINEER'S NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND
UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS
ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS.
TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING
'.. UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE
ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF
THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND
ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE
DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE
FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION
OF THEIR WORK.
SAFETY NOTICE TO CONTRACTOR
IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION
PRACTICES, THE CONTRACTOR WILL BE SOLELY AND
COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB
SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY
DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT
WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS.
THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION
REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT
INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE
CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE
CONSTRUCTION SITE.
OWNERSHIP OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS AN INSTRUMENT OF
PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON,
TULL, SPARKS & ASSOCIATES, INC., AND IS NOT TO BE
USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH
OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL,
SPARKS & ASSOCIATES, INC.
n
4�a
9 y £ 1
clu
(1) Quercus phellos
Existing Crape Myrtle
a
(1) Quercl phellos
e
I °(5) Existing Crape Myrtle
(4) Quercus phellos •
•
°
-1%
(1) Quercus phellos
llll2�
t LANDSCAPE NOTES
1. CONTRACTOR SHALL CONFIRM THE LOCATION OF ALL UTILITIES PRIOR
TO STARTING ANY WORK. THE CONTRACTOR IS RESPONSIBLE FOR
CONTACTING THE ONE—CALL SYSTEM. ALL UTILITY LOCATIONS SHOWN
ON THIS PLAN ARE APPROXIMATE AND ARE BASED ON SURVEY
INFORMATION, SITE DEVELOPMENT PLANS, UTILITY RECORDS, ETC.
2. ALL PLANT MATERIAL SHALL BE NURSERY GROWN. THE SIZE AND
GRADING SHALL MEET OR EXCEED THE LATEST EDITION OF AMERICAN
STANDARDS FOR NURSERY STOCK PUBLISHED BY THE AMERICAN
NURSERY AND LANDSCAPE ASSOCIATION.
3. ALL ENTRANCE/EXIT PLANTINGS SHALL BE INSTALLED AND MAINTAINED
TO PROVIDE CLEAR SIGHT DISTANCE FROM THE STREETS AND THE
ENTRANCE/EXIT LOCATIONS.
4. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING REQUIRED SHRUBS AND
TREES PER CITY LANDSCAPE ORDINANCE OR UNTIL PROJECT IS TURNED
OVER AND ACCEPTED BY OWNER.
5. NO CHANGES TO THE PLANT SCHEDULE ARE ALLOWED WITHOUT
APPROVAL OF THE OWNER, LANDSCAPE ARCHITECT AND CITY.
SUBSTITUTED PLANTS SHALL MEET THE SAME CRITERIA REGARDING
TYPE, SIZE AND FUNCTION AS THOSE PLANTS SHOWN ON THE PLAN.
6. ALL LAWN AREAS ARE TO RECEIVE 4" OF TOPSOIL TO FINAL GRADE.
ALL SHRUB AREAS SHALL RECEIVE 6" OF TOPSOIL SOIL SHALL BE
AMENDED TO ENHANCE FAVORABLE GROWING CONDITIONS. ALL
Trees
EXISTING SOD/WEEDS SHALL BE REMOVED FROM PLANTING BED AREAS.
7. ALL PLANT BEDS SHALL BE TREATED WITH A WEED BARRIER AND A
MINIMUM OF 3" SHREDDED HARDWOOD MULCH. TREES NOT LOCATED IN
PLANT BEDS SHALL RECEIVE A MULCH SAUCER PER DETAIL
8. ALL TREES AND SHRUBS SHALL BE INSTALLED IN ACCORDANCE WITH
THE DETAILS PROVIDED.
9. ALL SHRUBS AND TREES SHALL BE TREATED WITH 13-13-13 TIME
RELEASE FERTILIZER UPON COMPLETION OF THEIR INSTALLATION.
10. ALL DISTURBED AREAS NOT TO RECEIVE PLANTINGS SHALL BE SEEDED
WITH 60% BERMUDA GRASS AND 40% ANNUAL RYEGRASS AT 5 LBS PER
1,000 SF DURING THE APPROPRIATE TIME OF YEAR FOR THE SEED TO
GERMINATE; IF THIS CANNOT BE ACCOMPLISHED, THE CONTRACTOR
SHALL CALL THE LANDSCAPE ARCHITECT FOR A GRASS SEED
SUBSTITUTION.
11, AT A MINIMUM, SOD SHALL BE INSTALLED ON 3:1 SLOPES AND GREATER
AND AN EIGHTEEN INCH (18n) STRIP OF SOD SHALL BE INSTALLED
BEHIND ALL CURBS AND ADJACENT TO ALL SIDEWALKS AND ENTRY
WALKS.
12. IF A LANDSCAPE IRRIGATION SYSTEM IS PROPOSED. LANDSCAPE
CONTRACTOR TO CONFIRM LOCATION OF PROPOSED IRRIGATION LINES
WITH THE IRRIGATION CONTRACTOR PRIOR TO PLANT BED AND PLANT
INSTALLATION.
Plant Table
Note: All sod, seed. groundcover, shrub and tree quantities are approximate only.
Contractor should verify exact quantities prior to bidding.
(3) Pistacia chinensis
p
(1) Quercus phellos
L.
JF
• ••
Existing Pifle
Existing Pine
f � 3
� f3t
' • (1) Quercus
Chinese Pistache
Pistacia chinensis
10
2" -Cal, 8' -10' HT.
{
Willow oak
Quercus phellos
12
2" - Cal, 10' -12' HT.
Note: All sod, seed. groundcover, shrub and tree quantities are approximate only.
Contractor should verify exact quantities prior to bidding.
(3) Pistacia chinensis
p
(1) Quercus phellos
L.
JF
• ••
Existing Pifle
Existing Pine
f � 3
� f3t
' • (1) Quercus
v I C 1 �R/r
O
m O r*T
L) n
'\8C0-482—ag9�
f-
44��e�
GRAPHIC SCALE IN FEET
30' 0 .3
10825 Financial Center Parkway, Suite 300
Little Rock, Arkansas 72211
Crafton Tull Sparks
® engineering
501.664.3245 t 501.664.6704 f
www.craftontu Ilsporks.com
CERTIFICATE OF AUTHORIZATION:
CRAFION, TULL, r,
SPARKS& y
ASSOCIAi6, INC. --'
y No. 109 p
gp'tAHS AS Eft\NE�0. �.
PHILANDER SMITH COLLEGE
RESIDENTIAL QUAD
PHASE 1
900 DAISY L. GATSON BATES DRIVE
LITTLE ROCK, AR 72202
Key Plan
No. Description Date
This document, and the ideas and designs incorporated herein,
as an instrument of professional service, is the property of
Crafton, Tull, Sparks & Associates, Inc., and is not to be used, in
whole or in part, for any other project, without the written
authorization of Crafton, Tull, Sparks & Associates, Inc.
.*'R
PROJECT NO: 09$D32-02 ��i
ISSUE DATE: 01
CONTACT: B.' illiams 13ARR �'
CHECKED BY s� F:Y• RICHMOND
ISSUED FOR: WIWAMS :C-3
PERMIT 204 .•'� =
J�:'•..... 9
Associates,
Crafton, Tull, Sparks
Asso
&ciates, Inc. rtrrt grnl❑Outs
1-630 TREE REPLANTING
L-102
l
(3) DOUBLE STRAND GALV.
\
12 GUAGE WIRES PER TREE
TO BE IN GROUND FOR 2 YEARS
NOTE: ALTERNATIVE METHODS
OF GUYING MAY BE SUBMITTED
FOR REVIEW AND POSSIBLE
2 -PLY REINFORCED
APPROVAL.
RUBBER HOSE
(3) GUYING STAKES
WRAP TREES
(IF REQUIRED)
GALVANIZED WIRE
REMOVE BURLAP FROM TOP
CONSTRUCT EARTH SAUCER
1/3 OF ROOT BALL.
20°
WITH 2" HIGH EARTH BERM.
FLOOD TWICE WITH WATER
IN FIRST 24 HOURS;.
PLANTING MEDIUM TO BE
'SUPER SOIL' OR APPROVED OTTER R
r/
GROUNDNURSERY LINE TO THE SAME
,t`
ROOT BALL
3" DEPTH MULCH
—
AS THE
7
PL�
PLAN
(SEE SPECIFICATIONS)
-
��
TREE WELL
MIN. 9" LAYER OF PLANTING
_
T
7W, K
\
METAL STAKE
SOIL MIXTURE - FILL PIT WITH
,•••ter. L
••L. ��
\
WATER AND ALLOW LAYER TO
\
NOTE: PROVIDE
SETTLE PRIOR TO PLANTING -
\
ROOT STIMULATOORR AAS S PER
BREAK SUB -SOIL WITH PICK AXE.
\
MANUFACTURE'S
RECOMMENDATIONS
SECTION -
TREE
PLANTING DETAIL
NOT TO SCALE
v I C 1 �R/r
O
m O r*T
L) n
'\8C0-482—ag9�
f-
44��e�
GRAPHIC SCALE IN FEET
30' 0 .3
10825 Financial Center Parkway, Suite 300
Little Rock, Arkansas 72211
Crafton Tull Sparks
® engineering
501.664.3245 t 501.664.6704 f
www.craftontu Ilsporks.com
CERTIFICATE OF AUTHORIZATION:
CRAFION, TULL, r,
SPARKS& y
ASSOCIAi6, INC. --'
y No. 109 p
gp'tAHS AS Eft\NE�0. �.
PHILANDER SMITH COLLEGE
RESIDENTIAL QUAD
PHASE 1
900 DAISY L. GATSON BATES DRIVE
LITTLE ROCK, AR 72202
Key Plan
No. Description Date
This document, and the ideas and designs incorporated herein,
as an instrument of professional service, is the property of
Crafton, Tull, Sparks & Associates, Inc., and is not to be used, in
whole or in part, for any other project, without the written
authorization of Crafton, Tull, Sparks & Associates, Inc.
.*'R
PROJECT NO: 09$D32-02 ��i
ISSUE DATE: 01
CONTACT: B.' illiams 13ARR �'
CHECKED BY s� F:Y• RICHMOND
ISSUED FOR: WIWAMS :C-3
PERMIT 204 .•'� =
J�:'•..... 9
Associates,
Crafton, Tull, Sparks
Asso
&ciates, Inc. rtrrt grnl❑Outs
1-630 TREE REPLANTING
L-102