Loading...
Z-5675-C Map 7(3) Pistacia chinensis 1 (3) Quercus phellos `rte +eWL Nf"�M -;' ^k-•�4 W '� i � is } 'll (3) Pistacia chinensis r L �S•, I i NOTIFICATION OF LIMITED SERVICES CRAFTON, TULL, SPARKS & ASSOCIATES, INC., (CTSA) HAS NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A PORTION OF THE WORK INDICATED ON THESE DRAWINGS. THEREFORE, THE CTSA HEREBY NOTIFIES ALL PARTIES INVOLVED THAT THE CTSA ASSUMES NO RESPONSIBILITY FOR THE INTERPRETATION, COORDINATION AND ADMINISTRATION O THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THE EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL RELATED TRADES OR CONSTRUCTION SEQUENCES, OR OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC— IFICALLY REQUIRED IN THE CTSA's SERVICES AGREEMENT WITF THE OWNER. ENGINEER'S NOTICE TO CONTRACTOR THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING '.. UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK. SAFETY NOTICE TO CONTRACTOR IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE CONSTRUCTION SITE. OWNERSHIP OF DOCUMENTS THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON, TULL, SPARKS & ASSOCIATES, INC., AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL, SPARKS & ASSOCIATES, INC. n 4�a 9 y £ 1 clu (1) Quercus phellos Existing Crape Myrtle a (1) Quercl phellos e I °(5) Existing Crape Myrtle (4) Quercus phellos • • ° -1% (1) Quercus phellos llll2� t LANDSCAPE NOTES 1. CONTRACTOR SHALL CONFIRM THE LOCATION OF ALL UTILITIES PRIOR TO STARTING ANY WORK. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE ONE—CALL SYSTEM. ALL UTILITY LOCATIONS SHOWN ON THIS PLAN ARE APPROXIMATE AND ARE BASED ON SURVEY INFORMATION, SITE DEVELOPMENT PLANS, UTILITY RECORDS, ETC. 2. ALL PLANT MATERIAL SHALL BE NURSERY GROWN. THE SIZE AND GRADING SHALL MEET OR EXCEED THE LATEST EDITION OF AMERICAN STANDARDS FOR NURSERY STOCK PUBLISHED BY THE AMERICAN NURSERY AND LANDSCAPE ASSOCIATION. 3. ALL ENTRANCE/EXIT PLANTINGS SHALL BE INSTALLED AND MAINTAINED TO PROVIDE CLEAR SIGHT DISTANCE FROM THE STREETS AND THE ENTRANCE/EXIT LOCATIONS. 4. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING REQUIRED SHRUBS AND TREES PER CITY LANDSCAPE ORDINANCE OR UNTIL PROJECT IS TURNED OVER AND ACCEPTED BY OWNER. 5. NO CHANGES TO THE PLANT SCHEDULE ARE ALLOWED WITHOUT APPROVAL OF THE OWNER, LANDSCAPE ARCHITECT AND CITY. SUBSTITUTED PLANTS SHALL MEET THE SAME CRITERIA REGARDING TYPE, SIZE AND FUNCTION AS THOSE PLANTS SHOWN ON THE PLAN. 6. ALL LAWN AREAS ARE TO RECEIVE 4" OF TOPSOIL TO FINAL GRADE. ALL SHRUB AREAS SHALL RECEIVE 6" OF TOPSOIL SOIL SHALL BE AMENDED TO ENHANCE FAVORABLE GROWING CONDITIONS. ALL Trees EXISTING SOD/WEEDS SHALL BE REMOVED FROM PLANTING BED AREAS. 7. ALL PLANT BEDS SHALL BE TREATED WITH A WEED BARRIER AND A MINIMUM OF 3" SHREDDED HARDWOOD MULCH. TREES NOT LOCATED IN PLANT BEDS SHALL RECEIVE A MULCH SAUCER PER DETAIL 8. ALL TREES AND SHRUBS SHALL BE INSTALLED IN ACCORDANCE WITH THE DETAILS PROVIDED. 9. ALL SHRUBS AND TREES SHALL BE TREATED WITH 13-13-13 TIME RELEASE FERTILIZER UPON COMPLETION OF THEIR INSTALLATION. 10. ALL DISTURBED AREAS NOT TO RECEIVE PLANTINGS SHALL BE SEEDED WITH 60% BERMUDA GRASS AND 40% ANNUAL RYEGRASS AT 5 LBS PER 1,000 SF DURING THE APPROPRIATE TIME OF YEAR FOR THE SEED TO GERMINATE; IF THIS CANNOT BE ACCOMPLISHED, THE CONTRACTOR SHALL CALL THE LANDSCAPE ARCHITECT FOR A GRASS SEED SUBSTITUTION. 11, AT A MINIMUM, SOD SHALL BE INSTALLED ON 3:1 SLOPES AND GREATER AND AN EIGHTEEN INCH (18n) STRIP OF SOD SHALL BE INSTALLED BEHIND ALL CURBS AND ADJACENT TO ALL SIDEWALKS AND ENTRY WALKS. 12. IF A LANDSCAPE IRRIGATION SYSTEM IS PROPOSED. LANDSCAPE CONTRACTOR TO CONFIRM LOCATION OF PROPOSED IRRIGATION LINES WITH THE IRRIGATION CONTRACTOR PRIOR TO PLANT BED AND PLANT INSTALLATION. Plant Table Note: All sod, seed. groundcover, shrub and tree quantities are approximate only. Contractor should verify exact quantities prior to bidding. (3) Pistacia chinensis p (1) Quercus phellos L. JF • •• Existing Pifle Existing Pine f � 3 � f3t ' • (1) Quercus Chinese Pistache Pistacia chinensis 10 2" -Cal, 8' -10' HT. { Willow oak Quercus phellos 12 2" - Cal, 10' -12' HT. Note: All sod, seed. groundcover, shrub and tree quantities are approximate only. Contractor should verify exact quantities prior to bidding. (3) Pistacia chinensis p (1) Quercus phellos L. JF • •• Existing Pifle Existing Pine f � 3 � f3t ' • (1) Quercus v I C 1 �R/r O m O r*T L) n '\8C0-482—ag9� f- 44��e� GRAPHIC SCALE IN FEET 30' 0 .3 10825 Financial Center Parkway, Suite 300 Little Rock, Arkansas 72211 Crafton Tull Sparks ® engineering 501.664.3245 t 501.664.6704 f www.craftontu Ilsporks.com CERTIFICATE OF AUTHORIZATION: CRAFION, TULL, r, SPARKS& y ASSOCIAi6, INC. --' y No. 109 p gp'tAHS AS Eft\NE�0. �. PHILANDER SMITH COLLEGE RESIDENTIAL QUAD PHASE 1 900 DAISY L. GATSON BATES DRIVE LITTLE ROCK, AR 72202 Key Plan No. Description Date This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Crafton, Tull, Sparks & Associates, Inc., and is not to be used, in whole or in part, for any other project, without the written authorization of Crafton, Tull, Sparks & Associates, Inc. .*'R PROJECT NO: 09$D32-02 ��i ISSUE DATE: 01 CONTACT: B.' illiams 13ARR �' CHECKED BY s� F:Y• RICHMOND ISSUED FOR: WIWAMS :C-3 PERMIT 204 .•'� = J�:'•..... 9 Associates, Crafton, Tull, Sparks Asso &ciates, Inc. rtrrt grnl❑Outs 1-630 TREE REPLANTING L-102 l (3) DOUBLE STRAND GALV. \ 12 GUAGE WIRES PER TREE TO BE IN GROUND FOR 2 YEARS NOTE: ALTERNATIVE METHODS OF GUYING MAY BE SUBMITTED FOR REVIEW AND POSSIBLE 2 -PLY REINFORCED APPROVAL. RUBBER HOSE (3) GUYING STAKES WRAP TREES (IF REQUIRED) GALVANIZED WIRE REMOVE BURLAP FROM TOP CONSTRUCT EARTH SAUCER 1/3 OF ROOT BALL. 20° WITH 2" HIGH EARTH BERM. FLOOD TWICE WITH WATER IN FIRST 24 HOURS;. PLANTING MEDIUM TO BE 'SUPER SOIL' OR APPROVED OTTER R r/ GROUNDNURSERY LINE TO THE SAME ,t` ROOT BALL 3" DEPTH MULCH — AS THE 7 PL� PLAN (SEE SPECIFICATIONS) - �� TREE WELL MIN. 9" LAYER OF PLANTING _ T 7W, K \ METAL STAKE SOIL MIXTURE - FILL PIT WITH ,•••ter. L ••L. �� \ WATER AND ALLOW LAYER TO \ NOTE: PROVIDE SETTLE PRIOR TO PLANTING - \ ROOT STIMULATOORR AAS S PER BREAK SUB -SOIL WITH PICK AXE. \ MANUFACTURE'S RECOMMENDATIONS SECTION - TREE PLANTING DETAIL NOT TO SCALE v I C 1 �R/r O m O r*T L) n '\8C0-482—ag9� f- 44��e� GRAPHIC SCALE IN FEET 30' 0 .3 10825 Financial Center Parkway, Suite 300 Little Rock, Arkansas 72211 Crafton Tull Sparks ® engineering 501.664.3245 t 501.664.6704 f www.craftontu Ilsporks.com CERTIFICATE OF AUTHORIZATION: CRAFION, TULL, r, SPARKS& y ASSOCIAi6, INC. --' y No. 109 p gp'tAHS AS Eft\NE�0. �. PHILANDER SMITH COLLEGE RESIDENTIAL QUAD PHASE 1 900 DAISY L. GATSON BATES DRIVE LITTLE ROCK, AR 72202 Key Plan No. Description Date This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Crafton, Tull, Sparks & Associates, Inc., and is not to be used, in whole or in part, for any other project, without the written authorization of Crafton, Tull, Sparks & Associates, Inc. .*'R PROJECT NO: 09$D32-02 ��i ISSUE DATE: 01 CONTACT: B.' illiams 13ARR �' CHECKED BY s� F:Y• RICHMOND ISSUED FOR: WIWAMS :C-3 PERMIT 204 .•'� = J�:'•..... 9 Associates, Crafton, Tull, Sparks Asso &ciates, Inc. rtrrt grnl❑Outs 1-630 TREE REPLANTING L-102