Z-5675-C Map 4LEGEND (EXISTING)
o
FOUND IRON PIN
EASEMENT
LIGHT POLE
II I I
�2
POWER POLE
CURB
WATER
a
TELEPHONE PEDESTAL,
METER
- —1205
ED
TV PEDESTAL
INTERMEDIATE CONTOUR
IC
O
MANHOLE
--- -._. ___- _.— ----
-.__1205__
H N
I
INDEX CONTOUR
N �
o
SANITARY SEWER CLEANOUT
3
I WI �
ptlS
SS
�
GAS METER
SANITARY SEWER LINE
l6 II
D4
GAS VALVE
GAS LINE
—G—
C-=----�
STORM SEWER PIPE
W
DOWN GUY
WATER LINE (SPECIFY SIZE & TYPE)
>11
WATER VALVE
-LY
FIRE HYDRANT ASSEMBLY
UNDERGROUND TELEPHONE
C8l
AIR RELEASE VALVE
LIGE
UNDERGROUND ELECTRIC
'L.
FIRE DEPARTMENT CONNECTION
OHE
y�
o
WATER METER
OVERHEAD ELECTRIC
®
SPRINKLER HEAD
U GTV
M
ELECTRIC PEDESTAL
UNDERGROUND TELEVISION
OHTV
r® r
OVERHEAD TELEVISION
28211GRATED
LE R®J
INLET
CHAIN LINK FENCE
DROP INLET
--- 11-
//------
LL�JJ
VIOW FENCE-
--- - - X
X --- -
BARBED WIRE FENCE
y
TREE
FIBER OPTIC
RIGHT OF WAY
TREE TO BE REMOVED
ROAD CENTERLINE
LEGEND (PROPOSED)
SYMBOLS
•
�N
SETIN
EASEMENT
—
LIGHT POLE
lq
POWER POLE
CURB
■
TELEPHONE PEDESTAL
1205—
Is
TV PEDESTAL
INTERMEDIATE CONTOUR
Q
MANHOLE
1205 —
INDEX CONTOUR
o
SANITARY SEWER CLEANOUT
•
GAS METER
SANITARY SEWER LINE
N
GAS VALVE
O
STORM SEWER PIPE
GAS LINE
z -z
STRUCTURE NUMBER
WAS LINE
H
WATER VALVE
+4_
FIRE HYDRANT ASSEMBLY
UNDERGROUND TELEPHONE
IN
AIR RELEASE VALVE
._,.
FIRE DEPARTMENT CONNECTION
UNDERGROUND ELECTRIC
•
WATER METER
B
BACK FLOW PREVENTER
OVERHEAD ELECTRIC
G
REDUCER
FIBER OPTIC
PLUG VALVE
UUNDERGROUND
GRATED INLET
TEL EVIS_Trw
OVERHEAD TELEVISION
DROP INLET
CHAIN LINK FENCE
o
WOOD FENCE
x
x
BARBED WIRE FENCE
BUILDING SET BACK
RIGHT OF WAY
PROPERTY LINE
ROAD CENTERLINE
OHE
9
s
BLOCK 232, ORIGINAL
CITY OF LITTLE ROCK
EXISTING
I SIGN
EXISTING J
u
EXISTING FLAG POLE � EXISTING 3 I EgTING u eR� Fl_- Ar, POLE
RETAINING SIGN w I RETAINING
IC5 it MATCH EXIST
�: I GAZEBO PROPOSED CONC.
e33" Fs (I PORIT B S ?'ACE SIDEWALK
I� ll I PROPOSED
I = ^'` CURB AND GUTTER
I I I o N MATCH EXISTING
r l I ®36" F!TA CURB AND GUTTER
I�
RETAEXILI1NG Ili
I� INING I
IlI WA u WATCH EXISTING
11 Illi IDEWALK I/ PROPOSED CONC.
ETENN S COURT i1 Ill¢ SIDEWALK
I
WALL~ ( zo WA (�T
_�V--
NCRETE WALKwog,.
Al
EXISTING EXISTING
SIGN DR. TRUDIE KIBBE REED DRIVE SIGN
(FORMERLY W. 13th STREET -CLOSED BY ORD. NO. 16,324-60' R/W)
OHE c� = _ = MATCH EXISTIN
SPHALT PAVEMENT --- —
Y C— — — __&,UPCRE
II 63I
I � I �pNSFORMER
EXISTINp LE
LIGHT
BLOCK 233, ORIGINAL PROPOSED POWER
CITY OF LITTLE ROCK POLE AND GUY WIRE
MATCH EXISTING -
SIDEWALK
Z
.7fi
EXISTING
RETAINING
WAIL
EXISTING
LIGHT POLE
PROPOSED
SIDEWALK
MATCH EXISTING
SIDEWALK
PROPOSED
CURB AND GUTTER
MATCH EXISTING
CURB AND GUTTER
MATCH EXISTING
ASPHALT PAVEMENT
EXISTING
PIZOPOSED CONC.
SIDEWALK
4
GRAPHIC SCALE IN FEET
30' 0 30'
o'
w
SSMH ° II
FL 6" S 342.13
N_ 341.99
----see
--7—
_____ pp
------=---�_____-�---- — CURB iNLE1
�I F112 W.
SSMH 3h175
SS
A W 342.50o� FL 12 S. 341.75 341 75
f
FL 4250 PROPOSED ~ni N, SIZE UNKNOWN
S. 3w� FL
'_N 342.45 2" GAS LINE G PLANTER �I G MATCH EXISTING
^I SIDEWALK
����•����® i
3
PROPOSED
PLANTER
PROPOSED
RETAINING
WALL
SIDEWALK
PROPOSED MATCH E ISTING
PLANTER SIDEWALK
177771
my
EXISTING
INROUGHFENCE
IRON
PROPOSED
PLANTER PROPOSE
CONC.
—
R 18" STORM SEWER o
-- -- — -- CONCRETE WALK
I, MATCH EXISTING 1 FL Box. 35
PROPOSED SIDENALK \ \ CONCRE>f I I
li SIDEWALK STAIRS �— N,LOSURIE
III 22° ELM BLOCK 221, ORIGINAL NEW LIGHi\�\ —CONCRETE WALK ----J
I I, CITY OF LITTLE ROCK — — — — — —
MAT .b EXISTING POLE LOCATION
li CU AND GU 1 S
II ��--Z_s—.-Z_s--Z_s--Z_s--- Z—� II
II I
MATCH EXISTING EXISTING
1311 I SIDEWALK RETAINING
3 STORY BRICK WALL I
SII I BUILDING
�N
I Ijj�
EXISTING
SIGN
II I I
F1RE FIYDRAI
cc
I z
it I li II
WATER
o
I
METER
LU
t'J o
II
I II
CURB AND GUTTER
Cn m
IC
i 1
k'o
IIIIn� Ilii
J
H N
I
350.79
N �
II
II II,I
D4
SSMH 35219
II FL $n S 352.11
f
F1RE HYDRANT
�INSSEMBLY
L_
IIaI"r
II I Ir
II 3_OX N. 35378
FL B
F 18" S. 35378
DIG!
A�'/r
CCD q�Ls
O
LU Z
m M
-
� I NO ACCES
I FL 12 N.
I I
I I
-EXISTING
WROUG
PROPOSED IRON FENGE
CURB AND GUTTER
MATCH EXI TING
CURB AND Gl
II ME1ER
II PROPOSED CONC.
II SIDEWALK
I II w
� J
II Q N SITE NOTES
I II
I II r 1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL
I II I CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA
oil w STANDARDS.
I=11 I UJ 2. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT
�
CJI NLOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING,
INTI Z c SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING
< DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS.
III 3. ALL DIMENSIONS AND RADII ARE TO FACE/BACK OF CURB UNLESS
G vi OTHERWISE NOTED.
I ALL WORK SHALL BE DONE IN STRIC, , t;(;ORUANCE WLiH THE PROJECT
SPECIFICATIONS.
I I 5. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO
I 0 ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE
I IRESTRICTIVE.
N 6, CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED
IIPRIOR TO CONSTRUCTION START.
7. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE,
AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT.
6. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS,
I DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY
I I AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND
I I VEHICULAR TRAFFIC TO AND FROM THE SITE.
II
I I
I I I MATCH STING
I II SI EWALK
IY
I
I I �
I%
EXISTING
SIGN
F1RE FIYDRAI
ASSEMBLY
PROPOSED
CURB AND GUTTER
STOR I SEWER
MATCH EXISTING
CURB AND GUTTER
CURB IN
VL 12 W.
350.79
fL 12 E
350-79
3
I WI �
ptlS
G
I CcC'
SIGN
l6 II
ISI II
I III
NOTIFICATION OF LIMITED SERVICES
CRAFTON, TULL, SPARKS & ASSOCIATES, INC., (CTSA) HAS
NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION
ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A
PORTION OF THE WORK INDICATED ON THESE DRAWINGS.
THEREFORE, THE CTSA HEREBY NOTIFIES ALL PARTIES
INVOLVED THAT THE CTSA ASSUMES NO RESPONSIBILITY FOR
THE INTERPRETATION, COORDINATION AND ADMINIS?:RATION OF
THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THE
EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL
RELATED TRADES OR CONSTRUCTION SEQUENCES, OF
OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC—
IFICALLY REQUIRED IN THE CTSA's SERVICES AGREEMENT WI
THE OWNER.
ENGINEER'S NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND
UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS
ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS.
TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING
UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE
ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF
THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND
ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE
DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE
FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION
OF THEIR WORK.
SAFETY NOTICE TO CONTRACTOR
IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION
PRACTICES, THE CONTRACTOR WILL BE SOLELY AND
COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB
SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY
DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT
WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS.
THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION
REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT
INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE
CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE
CONSTRUCTION SITE.
OWNERSHIP OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS AN INSTRUMENT OF
PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON,
TULL, SPARKS & ASSOCIATES, INC., AND IS NOT TO BE
USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH
OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL,
SPARKS & ASSOCIATES, INC.
10825 Financial Center Parkway, Suite 300
Little Rock, Arkansas 72211
Crafton Tull Sparks
® engineering
501.664.3245 t 501.664.6704 f
www.craftontullsparks.com
CERTIFICATE OF AUTHORIZATION. '
CRAFTON, TULL r,
SPARKS& y.
o ASSOCIATES, INC.
zy No.1D9
gQCANSAs ENGO't
PHILANDER SMITH COLLEGE
RESIDENTIAL QUAD
MASTER PLAN
ONE TRUDIE KIBBE REED DRIVE
LITTLE ROCK, AR 72202
Key Plan
ILrd�IJ:.: Try Liv f' GG�n,w+r— ��
BY: A
DATE:: y' A -d' L9
No. Description Date
This document, and the ideas and designs incorporated herein,
as an instrument of professional service, is the property of
Crafton, Tull, Sparks & Associates, Inc., and is not to be usrd, in
whole or in part, for any other project, without the written
authorization of Crafton, Tull, Sparks & Associates, Inc.
'091µUCTION
PROJECT NO: 098032-02 °°
ISSUE DAYS: 11/09/09 ,ate THIS F�
CONTACT: B.Williams DOCUMENT IS N
CHECKED BY: 2 PRELIMINARY IN a
NATURE AND IS NOT
PRELIMINARY LA FINAL, SIGNED o
ti,PLANSAND SEALED Y
®2009 Crafton, Tull, Sparks ��0, DOCUMENT
& Associates, Inc. & N011011ti 15�°0
SITE PLAN
III, ��-
C-101