Loading...
Z-5675-C Map 4LEGEND (EXISTING) o FOUND IRON PIN EASEMENT LIGHT POLE II I I �2 POWER POLE CURB WATER a TELEPHONE PEDESTAL, METER - —1205 ED TV PEDESTAL INTERMEDIATE CONTOUR IC O MANHOLE --- -._. ___- _.— ---- -.__1205__ H N I INDEX CONTOUR N � o SANITARY SEWER CLEANOUT 3 I WI � ptlS SS � GAS METER SANITARY SEWER LINE l6 II D4 GAS VALVE GAS LINE —G— C-=----� STORM SEWER PIPE W DOWN GUY WATER LINE (SPECIFY SIZE & TYPE) >11 WATER VALVE -LY FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE C8l AIR RELEASE VALVE LIGE UNDERGROUND ELECTRIC 'L. FIRE DEPARTMENT CONNECTION OHE y� o WATER METER OVERHEAD ELECTRIC ® SPRINKLER HEAD U GTV M ELECTRIC PEDESTAL UNDERGROUND TELEVISION OHTV r® r OVERHEAD TELEVISION 28211GRATED LE R®J INLET CHAIN LINK FENCE DROP INLET --- 11- //------ LL�JJ VIOW FENCE- --- - - X X --- - BARBED WIRE FENCE y TREE FIBER OPTIC RIGHT OF WAY TREE TO BE REMOVED ROAD CENTERLINE LEGEND (PROPOSED) SYMBOLS • �N SETIN EASEMENT — LIGHT POLE lq POWER POLE CURB ■ TELEPHONE PEDESTAL 1205— Is TV PEDESTAL INTERMEDIATE CONTOUR Q MANHOLE 1205 — INDEX CONTOUR o SANITARY SEWER CLEANOUT • GAS METER SANITARY SEWER LINE N GAS VALVE O STORM SEWER PIPE GAS LINE z -z STRUCTURE NUMBER WAS LINE H WATER VALVE +4_ FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE IN AIR RELEASE VALVE ._,. FIRE DEPARTMENT CONNECTION UNDERGROUND ELECTRIC • WATER METER B BACK FLOW PREVENTER OVERHEAD ELECTRIC G REDUCER FIBER OPTIC PLUG VALVE UUNDERGROUND GRATED INLET TEL EVIS_Trw OVERHEAD TELEVISION DROP INLET CHAIN LINK FENCE o WOOD FENCE x x BARBED WIRE FENCE BUILDING SET BACK RIGHT OF WAY PROPERTY LINE ROAD CENTERLINE OHE 9 s BLOCK 232, ORIGINAL CITY OF LITTLE ROCK EXISTING I SIGN EXISTING J u EXISTING FLAG POLE � EXISTING 3 I EgTING u eR� Fl_- Ar, POLE RETAINING SIGN w I RETAINING IC5 it MATCH EXIST �: I GAZEBO PROPOSED CONC. e33" Fs (I PORIT B S ?'ACE SIDEWALK I� ll I PROPOSED I = ^'` CURB AND GUTTER I I I o N MATCH EXISTING r l I ®36" F!TA CURB AND GUTTER I� RETAEXILI1NG Ili I� INING I IlI WA u WATCH EXISTING 11 Illi IDEWALK I/ PROPOSED CONC. ETENN S COURT i1 Ill¢ SIDEWALK I WALL~ ( zo WA (�T _�V-- NCRETE WALKwog,. Al EXISTING EXISTING SIGN DR. TRUDIE KIBBE REED DRIVE SIGN (FORMERLY W. 13th STREET -CLOSED BY ORD. NO. 16,324-60' R/W) OHE c� = _ = MATCH EXISTIN SPHALT PAVEMENT --- — Y C— — — __&,UPCRE II 63I I � I �pNSFORMER EXISTINp LE LIGHT BLOCK 233, ORIGINAL PROPOSED POWER CITY OF LITTLE ROCK POLE AND GUY WIRE MATCH EXISTING - SIDEWALK Z .7fi EXISTING RETAINING WAIL EXISTING LIGHT POLE PROPOSED SIDEWALK MATCH EXISTING SIDEWALK PROPOSED CURB AND GUTTER MATCH EXISTING CURB AND GUTTER MATCH EXISTING ASPHALT PAVEMENT EXISTING PIZOPOSED CONC. SIDEWALK 4 GRAPHIC SCALE IN FEET 30' 0 30' o' w SSMH ° II FL 6" S 342.13 N_ 341.99 ----see --7— _____ pp ------=---�_____-�---- — CURB iNLE1 �I F112 W. SSMH 3h175 SS A W 342.50o� FL 12 S. 341.75 341 75 f FL 4250 PROPOSED ~ni N, SIZE UNKNOWN S. 3w� FL '_N 342.45 2" GAS LINE G PLANTER �I G MATCH EXISTING ^I SIDEWALK ����•����® i 3 PROPOSED PLANTER PROPOSED RETAINING WALL SIDEWALK PROPOSED MATCH E ISTING PLANTER SIDEWALK 177771 my EXISTING INROUGHFENCE IRON PROPOSED PLANTER PROPOSE CONC. — R 18" STORM SEWER o -- -- — -- CONCRETE WALK I, MATCH EXISTING 1 FL Box. 35 PROPOSED SIDENALK \ \ CONCRE>f I I li SIDEWALK STAIRS �— N,LOSURIE III 22° ELM BLOCK 221, ORIGINAL NEW LIGHi\�\ —CONCRETE WALK ----J I I, CITY OF LITTLE ROCK — — — — — — MAT .b EXISTING POLE LOCATION li CU AND GU 1 S II ��--Z_s—.-Z_s--Z_s--Z_s--- Z—� II II I MATCH EXISTING EXISTING 1311 I SIDEWALK RETAINING 3 STORY BRICK WALL I SII I BUILDING �N I Ijj� EXISTING SIGN II I I F1RE FIYDRAI cc I z it I li II WATER o I METER LU t'J o II I II CURB AND GUTTER Cn m IC i 1 k'o IIIIn� Ilii J H N I 350.79 N � II II II,I D4 SSMH 35219 II FL $n S 352.11 f F1RE HYDRANT �INSSEMBLY L_ IIaI"r II I Ir II 3_OX N. 35378 FL B F 18" S. 35378 DIG! A�'/r CCD q�Ls O LU Z m M - � I NO ACCES I FL 12 N. I I I I -EXISTING WROUG PROPOSED IRON FENGE CURB AND GUTTER MATCH EXI TING CURB AND Gl II ME1ER II PROPOSED CONC. II SIDEWALK I II w � J II Q N SITE NOTES I II I II r 1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL I II I CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA oil w STANDARDS. I=11 I UJ 2. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT � CJI NLOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, INTI Z c SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING < DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS. III 3. ALL DIMENSIONS AND RADII ARE TO FACE/BACK OF CURB UNLESS G vi OTHERWISE NOTED. I ALL WORK SHALL BE DONE IN STRIC, , t;(;ORUANCE WLiH THE PROJECT SPECIFICATIONS. I I 5. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO I 0 ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE I IRESTRICTIVE. N 6, CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED IIPRIOR TO CONSTRUCTION START. 7. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE, AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT. 6. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS, I DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY I I AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND I I VEHICULAR TRAFFIC TO AND FROM THE SITE. II I I I I I MATCH STING I II SI EWALK IY I I I � I% EXISTING SIGN F1RE FIYDRAI ASSEMBLY PROPOSED CURB AND GUTTER STOR I SEWER MATCH EXISTING CURB AND GUTTER CURB IN VL 12 W. 350.79 fL 12 E 350-79 3 I WI � ptlS G I CcC' SIGN l6 II ISI II I III NOTIFICATION OF LIMITED SERVICES CRAFTON, TULL, SPARKS & ASSOCIATES, INC., (CTSA) HAS NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A PORTION OF THE WORK INDICATED ON THESE DRAWINGS. THEREFORE, THE CTSA HEREBY NOTIFIES ALL PARTIES INVOLVED THAT THE CTSA ASSUMES NO RESPONSIBILITY FOR THE INTERPRETATION, COORDINATION AND ADMINIS?:RATION OF THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THE EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL RELATED TRADES OR CONSTRUCTION SEQUENCES, OF OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC— IFICALLY REQUIRED IN THE CTSA's SERVICES AGREEMENT WI THE OWNER. ENGINEER'S NOTICE TO CONTRACTOR THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK. SAFETY NOTICE TO CONTRACTOR IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE CONSTRUCTION SITE. OWNERSHIP OF DOCUMENTS THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON, TULL, SPARKS & ASSOCIATES, INC., AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL, SPARKS & ASSOCIATES, INC. 10825 Financial Center Parkway, Suite 300 Little Rock, Arkansas 72211 Crafton Tull Sparks ® engineering 501.664.3245 t 501.664.6704 f www.craftontullsparks.com CERTIFICATE OF AUTHORIZATION. ' CRAFTON, TULL r, SPARKS& y. o ASSOCIATES, INC. zy No.1D9 gQCANSAs ENGO't PHILANDER SMITH COLLEGE RESIDENTIAL QUAD MASTER PLAN ONE TRUDIE KIBBE REED DRIVE LITTLE ROCK, AR 72202 Key Plan ILrd�IJ:.: Try Liv f' GG�n,w+r— �� BY: A DATE:: y' A -d' L9 No. Description Date This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Crafton, Tull, Sparks & Associates, Inc., and is not to be usrd, in whole or in part, for any other project, without the written authorization of Crafton, Tull, Sparks & Associates, Inc. '091µUCTION PROJECT NO: 098032-02 °° ISSUE DAYS: 11/09/09 ,ate THIS F� CONTACT: B.Williams DOCUMENT IS N CHECKED BY: 2 PRELIMINARY IN a NATURE AND IS NOT PRELIMINARY LA FINAL, SIGNED o ti,PLANSAND SEALED Y ®2009 Crafton, Tull, Sparks ��0, DOCUMENT & Associates, Inc. & N011011ti 15�°0 SITE PLAN III, ��- C-101