Loading...
boa_06 26 2017LITTLE ROCK BOARD OF ADJUSTMENT SUMMARY OF MINUTES JUNE 26, 2017 2:00 P.M. Roll Call and Finding of a Quorum A Quorum was present being four (4) in number. Approval of the Minutes of the Previous Meetings The Minutes of the May 22, 2017 meeting were approved. Members Present: Frank Allison Carolyn Lindsey Polk Jeff Yates, Chairman Robert Tucker, Vice Chairman Members Absent: Christopher Smith City Attorney Present: Debra Weldon LITTLE ROCK BOARD OF ADJUSTMENT I. OLD BUSINESS: No Old Business II. NEW BUSINESS: 1. Z -8409-A 2. Z -9033-A 3. Z-9221 4. Z-9222 5. Z-9223 6. Z-9224 7. Z-9225 JUNE 26, 2017 2:00 P.M. 5216 Edgewood Road NE Corner of W. 36t" Street and Bowman Road 1019 Beechwood Street 500 N. Cedar Street 6201 Patterson Road 5423 Hawthorne Road 611 Main Street JUNE 26, 2017 ITEM NO.: 1 File No.: Owner/Applicant: Address: Description: Zoned: Jerry and Jana Bishop 5216 Edgewood Road Lot 44, Prospect Terrace Addition Variance Requested: Variances are requested from the area provisions of Section 36-254 and 36-156 to allow a carport addition to a principal structure and a porch addition to an accessory structure with reduced side setbacks. Justification: The applicant's justification is presented in an attached letter. Present Use of Property: Single Family Residential Proposed Use of Property: Single Family Residential STAFF REPORT /la Public Works Issues: No Comments Building Codes Comments: The required fire separation distance (building to property line) prescribed by the building code terminates at five (5) feet. Buildings are allowed to be closer than five (5) feet if they have properly constructed fire walls which provide the requisite one (1) hour fire resistance rating. When buildings are five (5) feet or more from the property line, the requirement no longer applies to the wall itself, only the projection such as eaves or overhangs. Openings such as doors and windows are limited when the exterior wall is three (3) feet from the property line, and are prohibited when the exterior wall is less than three (3) feet from the line. There is no restriction on openings when the exterior wall is more than three (3) feet from the property line. Contact the City of Little Rock Building Codes at 371-4832 for additional details. JUNE 26, 2017 ITEM NO.: 1 (CON'T.) Z -8409-A C. Staff Analysis: The R-2 zoned property at 5216 Edgewood Road is occupied by a two (2) story frame and stucco single family residence. The property is located on the north side of Edgewood road and backs up to "O" Street. A two-story accessory garage structure is located within the rear yard area, at the northeast corner of the property. A single car wide driveway is located at the southeast corner of the lot. The driveway extends along the east side of the residence to the accessory garage structure. The applicant proposes to construct two (2) building additions; one (1) to the principal structure and one (1) to the accessory structure. An 18.5 foot by 24 foot carport addition is proposed on the east side of the existing residence. An eight (8) foot by 20 foot covered porch addition is proposed along the south side of the existing accessory garage structure. Both additions will have a one-story height. The proposed carport addition will be located approximately 40 feet back from the front (south) property line and one (1) to 2.5 feet back from the east side property line. The carport will be unenclosed on its north, south and east sides. The proposed covered porch addition to the existing accessory structure will be located two (2) feet from the east side property line and 19.5 feet to 23 feet back from the rear, "O" Street, property line. The porch will be unenclosed on its east, west and south sides. Section 36-254(d)(2)of the City's Zoning Ordinance requires a minimum side setback of eight (8) feet for the principal structure on this lot. Section 36-156(a)(2)f. requires a minimum side setback of three (3) feet for accessory structures. Section 36-156(a)(2)c. requires that accessory structures be located at least 60 feet back from front or rear street fronting property lines. Therefore, the applicant is requesting variances from these ordinance standards to allow the carport addition with a reduced side setback, and the porch addition with reduced side and rear (street fronting) setbacks. Staff is supportive of the requested side setback variance for the proposed carport addition to the principal structure, and the side and rear (street fronting) setback variances for the porch addition to the accessory structure. Staff views the request as reasonable. Staff typically looks for a minimum side setback of 1.5 feet for unenclosed carport additions. The proposed carport addition is located one (1) foot from the east side property line at one (1) point, then angles away from the side property line to a 2.5 foot setback. Ample separation will exist between this proposed carport addition and the residence immediately to the east. A driveway on the neighboring property will separate the two (2) residences. With respect to the porch addition to the existing accessory structure, the proposed side and rear setbacks are greater than the existing structure. Staff believes the proposed unenclosed additions to the existing house and accessory structure will have no adverse impact on the adjacent properties or the general area. JUNE 26, 2017 ITEM NO.: 1 (CON'T.) Z -8409-A D. Staff Recommendation: Staff recommends approval of the requested side and rear (street fronting) setback variances, subject to the following conditions: 1. The carport addition must remain unenclosed on its north, south and east sides. 2. The porch addition must remain unenclosed on its east, west and south sides. 3. Compliance with the Building Codes requirements as noted in paragraph B. of the staff report. 4. Guttering must be provided on the carport addition, if the roof slope dictates, to prohibit water run-off onto the adjacent property to the east. BOARD OF ADJUSTMENT (June 26, 2017) The applicant was present. There were no objectors present. Staff presented the item and a recommendation of approval as outlined in the "staff recommendation" above. There was no further discussion. The item was placed on the consent agenda and approved as recommended by the vote of 4 ayes, 0 noes and 1 absent. --'mac Jerry and Janna Bishop 5216 Edgewood Road Little Rock,AR 72207 May 22, 2017 Board of Adjustment City of Little Rock, Arkansas Dear Members of the Board: We are requesting a zoning variance to build an addition to our home located at 5216 Edgewood in Little Rock. We wish to add a porte cochere and covered breezeway onto the east and north corner of our home. The porte cochere will be over the existing driveway. Also we wish to add a covered porch to our existing detached guest house. These additions will be in the style of the home and neighborhood. Thank you for your consideration, 1 Jerry and Janna Bishop JUNE 26, 2017 ITEM NO.: 2 File No.: Owner: Applicant: Address: Description: Zoned: Variance Requested: Justification: Present Use of Property: Proposed Use of Property STAFF REPORT 11 s Public Works Issues: No Comments. Z -9033-A Garth Development, LLC Tim Daters, White Daters and Associates 11800 W. 36th Street Northeast corner of W. 36th Street and Bowman Road C-1 A variance is requested from the height provisions of Section 36-299 to allow a new building with increased height. The applicant's justification is presented in an attached letter. Undeveloped Property Commercial/Mixed Use Landscape and Buffer Issues: Site plan must comply with the City's minimal landscape/buffer ordinance requirements. Signage is to be reviewed and permitted separately. Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-ways. Provide screening shrubs with an average linear spacing of not less than three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property or the right-of-way of any street. This strip shall be at least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting strip. The north perimeter planting strip is less than nine (9) feet in width. A land use buffer will be required when an adjacent property has a dissimilar use of a more restrictive nature. As a component of all land use buffer requirements, JUNE 26, 2017 ITEM NO.: 2 (CON'T.) Z -9033-A opaque screening, whether a fence or other device, a minimum of six (6) feet in height shall be required upon the property line side of the buffer. A minimum of seventy (70) percent of the land use buffer shall be undisturbed. Easements cannot count toward fulfilling this requirement. The plantings, existing and purposed, shall be provided within the landscape ordinance of the city, section 15-81. The property to the north is zoned PDR, a minimum buffer will be required at six (6) percent of the average width of the lot but no case less than nine (9) feet. Eight percent (8%) of the vehicular use area must be designated for green space; this green space needs to be evenly distributed throughout the parking area(s). The minimum size of an interior landscape area shall be three hundred (300) square feet for developments with more than one hundred fifty (150) parking spaces. Interior islands must be a minimum of seven and one half (7 %2) feet in width. Trees shall be included in the interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces. An automatic irrigation system to water landscaped areas shall be required for developments for one (1) acre or larger. The development of two (2) acres or more requires the landscape plan to be stamped with the seal of a Registered Landscape Architect. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. C. Staff Analysis: The C-1 zoned property located at 11800 W. 36th Street is currently undeveloped. The property is located at the northeast corner of W. 36th Street and Bowman Road. The property is comprised of 6.95 acres. Extensive site work has been done, in conjunction with the property to the north, in preparation for new development. Some street improvements have been made along the W. 36th Street (south) and Bowman Road (west) property lines (extra pavement, curbs, gutters and sidewalk). The applicant proposes to construct a four-story commercial building near the center of the property, as noted on the attached site plan. The building will be located approximately 42 feet back from the east property line, 72 to 110 feet from the west property line and over 140 feet from the north and south property lines. The building will have a height of 65 feet. A paved parking area is proposed on the south side of the building with 180 parking spaces. An access driveway from Bowman Road will serve as access to this parking area. Paved parking is also proposed on the north side of the building, containing 158 spaces. This parking is proposed to take access through the apartment complex to the north. Section 36-299(d) of the City's Zoning Ordinance allows a maximum building height of 25 feet for C-1 zoned property. Therefore, the applicant is requesting a variance to allow an increased building height of 65 feet for the proposed development. 1) JUNE 26, 2017 ITEM NO.: 2 (CON'T.) Z -9033-A Staff is supportive of the requested building height variance. Staff views the request as reasonable. The proposed building height will not be out of character with other buildings and zoning in the immediate area. The new apartment buildings immediately to the north are three (3) stories in height and at a higher elevation than the subject property. The apartment Complex across Bowman Road to the west also has three (3) story buildings. The main building within the Church at Rock Creek property to the east also has a building height equivalent to three (3) stories. The 0-2 zoned property across Bowman Road to the west allows a maximum building height of 120 feet with increased building setbacks. Staff believes the proposed building height will be compatible with the general area and have no adverse impact on the surrounding properties. D. Staff Recommendation: Staff recommends approval of the requested building height variance, subject to compliance with the Landscape and Buffer requirements as noted in paragraph B. of the staff report. BOARD OF ADJUSTMENT (June 26, 2017) The applicant was present. There were no objectors present. Staff presented the item and a recommendation of approval as outlined in the "staff recommendation" above. There was no further discussion. The item was placed on the consent agenda and approved as recommended by the vote of 4 ayes, 0 noes and 1 absent. FATE - DATERS & .ASSOCIATES, INC. 24 Rahling Circle ID Little Rock, Arkansas 72223 Phone: 501-821-1667 www.whitedaters.com May 23, 2017 Mr. Monte Moore, Zoning Administrator City of Little Rock 723 W. Markham St. Little Rock, Arkansas 72201 RE: Zoning Variance — Garth Development LLC Mr. Moore, t z- 3.3 - Attached are 6 copies of the site plan for the above captioned project, the application, affidavit and application fee of $205.00. The Owner is requesting a variance on the maximum building height to permit the construction of a 4 story mixed use building on this 6.9545 acre site. Encl: 6 copies of survey Application Form Affidavit Application fee if you need any additional information. CIVIL ENGINEERING - LAND PLANNING & DEVELOPMENT - SURVEYING - LANDSCAPE ARCHITECTURE JUNE 26, 2017 ITEM NO.: 3 File No.: Z-9221 Owner: Jason and Allison Thomas Applicant: Carolyn Lindsey, Yeary Lindsey Architects Address: 1019 Beechwood Street Description: Lot 16, Block 11, Hillcrest Addition Zoned: R-2 Variance Requested: A variance is requested from the area provisions of Section 36-254 to allow a building addition with a reduced side setback. Justification: The applicant's justification is presented in an attached letter. Present Use of Property: Single Family Residential Proposed Use of Property: Single Family Residential STAFF REPORT FA Public Works Issues: No Comments Building Codes Comments: The required fire separation distance (building to property line) prescribed by the building code terminates at five (5) feet. Buildings are allowed to be closer than five (5) feet if they have properly constructed fire walls which provide the requisite one (1) hour fire resistance rating. When buildings are five (5) feet or more from the property line, the requirement no longer applies to the wall itself, only the projection such as eaves or overhangs. Openings such as doors and windows are limited when the exterior wall is three (3) feet from the property line, and are prohibited when the exterior wall is less than three (3) feet from the line. There is no restriction on openings when the exterior wall is more than three (3) feet from the property line. Contact the City of Little Rock Building Codes at 371-4832 for additional details. JUNE 26, 2017 ITEM NO.: 3 (CON'T.) Z-9221 C Staff Analysis: The R-2 zoned property at 1019 Beechwood Street is occupied by a two-story frame single family residence. The property is located on the east side of Beechwood Street, south of Kenyon Street. There is a one-story accessory garage structure within the rear yard area, at the southeastern corner of the lot. A paved alley is located along the rear (east) property line. A one car wide driveway from the alley serves the garage structure. The applicant proposes to construct a 13 foot by 13 foot addition to the south side of the residence, as noted on the attached site plan. The addition will be located three (3) feet from the south side property line and have a two (2) story height. The addition will allow for a dining room and master closet. The applicant is also making a first floor storage room addition to the accessory garage structure and a second floor addition to the accessory structure. Section 36-254(d)(2) of the City's Zoning Ordinance requires a minimum side setback of 4.8 feet for the principal structure on this R-2 zoned lot. Therefore, the applicant is requesting a variance to allow the proposed addition with a reduced side setback. Staff is supportive of the requested side setback variance. Staff views the request as reasonable. The lot has a relatively narrow width of only 48 feet. The proposed building addition will have a side setback of three (3) feet. The addition will have a reduced setback for only 13 feet along a side property line which measures 179 feet. Additionally, there should be ample separation between the proposed addition and the residence immediately to the south. It appears that the neighboring residence is approximately five (5) feet back from the dividing side property line. Staff believes the proposed addition will have no adverse impact on the adjacent properties or the general area. D. Staff Recommendation: Staff recommends approval of the requested side setback variance, subject to compliance with the Building Codes requirements as noted in paragraph B. of the staff report. BOARD OF ADJUSTMENT (June 26, 2017) The applicant was present. There were no objectors present. Staff presented the item and a recommendation of approval as outlined in the "staff recommendation" above. There was no further discussion. The item was placed on the consent agenda and approved as recommended by the vote of 3 ayes, 0 noes and 1 absent and 1 recusal (Lindsey Polk) a , ..e` Lindsey Architects May 22, 2017 Mr. Monte Moore Department of Neighborhoods and Planning 723'1 est Markham Little Rock, AR 72201 RE: Zoning Variance Application for Thomas Residence, 1019 Beechwood, Little Rock, AR 72205 7— Dear Monte, This project consists of a two story dining room / master closet addition to the main house, a first floor storage room plus second story addition to the detached garage and a 6-0" high stone wall at the rear property line to enclose the back yard. We are requesting a zoning variance to allow the following - 1 s Reduced south side 4.8' setback to allow the dining room / master closet addition to project into the setback, reducing it to 3'-0". Also, note that our percentage of window openings is 12% of the wail that is proposed to be 3'-0" from the south property line. Code requires the openings in walls 3'-0" to 5'-0" from the property line to be < 25%. Although the lot is long, it is a little narrower than the typical lot in this area. And due to the front setback rules, the (rouse sits 50'+ from the Beechwood property line not allowing easy expansion into the rear of the lot. All of these combine to require a side yard setback variance for the addition of a dining room approximately 12'-8"x12'-8" in size located just off the kitchen. Thank you for your time and consideration. Sincerely, Carolyn A. Li dsey, AIA 3416 Old Cantrell Road Little Rock, Arkansas 72202 501-372-5940 Fax: 501-663-0043 JUNE 26, 2017 ITEM NO.: 4 File No.: Z-9222 Owner: Megan Eves and Joseph Williams Applicant: Megan Eves Address: 500 N. Cedar Street Description: Lot 6 and part of Lot 5, Block 3, Pulaski Heights Addition Zoned: R-3 Variance Requested: A variance is requested from the area provisions of Section 36-156 to allow a second floor addition to an accessory building with a reduced side setback. Justification: The applicant's justification is presented in an attached letter. Present Use of Property: Single Family Residence Proposed Use of Property: Single Family Residence STAFF REPORT I�1 M Public Works Issues: No Comments. Building Codes Comments: The required fire separation distance (building to property line) prescribed by the building code terminates at five (5) feet. Buildings are allowed to be closer than five (5) feet if they have properly constructed fire walls which provide the requisite one (1) hour fire resistance rating. When buildings are five (5) feet or more from the property line, the requirement no longer applies to the wall itself, only the projection such as eaves or overhangs. Openings such as doors and windows are limited when the exterior wall is three (3) feet from the property line, and are prohibited when the exterior wall is less than three (3) feet from the line. There is no restriction on openings when the exterior wall is more than three (3) feet from the property line. Contact the City of Little Rock Building Codes at 371-4832 for additional details. JUNE 26, 2017 ITEM NO.: 4 (CON'T.) Z-9222 C. Staff Analysis: The R-3 zoned property at 500 N. Cedar Street is occupied by a two-story brick and frame single family structure. The property is located at the northwest corner of N. Cedar Street and Lee Avenue. A two -car accessory garage structure is located within the rear yard area, at the northwest corner of the lot. A paved driveway from Lee Avenue serves as access to the garage structure. A paved alley is located along the rear (west) property line. The applicant proposes to add a second floor addition to the existing accessory garage structure at the northwest corner of the property, as noted on the attached site plan and elevation sketches. The existing garage structure is located 0.8 foot to one (1) foot back from the rear (west) property line and 0.5 foot to 0.8 foot back from the north side property line. The second level will essentially be a tali roof with living space within the roofline. Section 36-156(a)(2)f. of the City's Zoning Ordinance requires a minimum side setback of three (3) feet for accessory structures in the R-3 zoning district. Therefore, the applicant is requesting a variance from this ordinance requirement to construct a second floor on the existing accessory structure. Staff is supportive of the requested side setback variance. Staff views the request as reasonable. The proposed second level addition is essentially no more than a higher roof pitch than what exists with usable space within the roof line (attic -type space). The second level will maintain the same side setback as currently exists. The existing accessory structure with decreased side setback is not out of character with other accessory structures throughout this neighborhood. Staff feels that the proposed second floor addition to the existing accessory structure, with decreased side setback, will have no adverse impact on the adjacent properties or the general area. D. Staff Recommendation: Staff recommends approval of the requested side setback variance, subject to the following conditions: 1. Compliance with the Building Codes comments as noted in paragraph B. of the staff report. 2. The accessory structure shall not be used as a separate dwelling. 3. No portion of the roof overhang shall cross the north side property line. BOARD OF ADJUSTMENT The applicant was present. There were no objectors present. and a recommendation of approval as outlined in the "staff There was no further discussion. The item was placed on approved as recommended by the vote of 4 ayes, 0 noes and 2 (June 26, 2017) Staff presented the item recommendation" above. the consent agenda and absent. Megan Eves 500 North Cedar Street, Little Rock, Arkansas 72205 501.554.9103 May 23, 2017 - '2- Little Rock Department of Planning and Development 723 West Markham Street Little Rock, Arkansas 72201 Dear Little Rock Department of Planning and Development, I am the owner of a residential property in the Hillcrest neighborhood, and I am requesting a variance from the City of Little Rock's ordinance requiring a three -foot -wide setback between any structure and the property line. I want to add a second floor onto the existing garage structure that is currently located at the rear of my property, in the northwest corner along the alley. The second floor will be used as a spare bedroom for visiting family members, as our main home's three bedrooms are not sufficient. The additional space would include a sleeping area and a small bathroom, but no kitchen. I have had the proposed plans reviewed by Mr. Brian Minyard (see the attached drawing of the external elevations), and the desired addition to the garage satisfies all the requirements of the Hillcrest Design Overlay District. The sole issue is that the existing structure does not sit the full three feet off the northern property line as required by ordinance. The existing structure is sound, so I am seeking a variance from the setback requirement based on the fact that the current structural configuration is adequate, and there is no justification for tearing down the existing building to move it two feet to the south. I understand that if this application is accepted, I will need to notify all owners of land lying within 200 feet of the boundary of my property in advance of the Board of Adjustment's hearing on June 26, 2017. Sincerely, MerEves JUNE 26, 2017 ITEM NO.: 5 File No.: Z-9223 Owner: Gateway Properties of Little Rock, AR, LLC Applicant: Bear Davidson, Marlar Engineering Co., Inc. Address: 6201 Patterson Road Description: East side of Patterson Street, North of W. 65th Street Zoned: 1-2 Variance Requested: A variance is requested from the buffer provisions of Section 36-522 to allow a building addition with a reduced street buffer. Justification: The applicant's justification is presented in an attached letter. Present Use of Property: Tire Distribution Proposed Use of Property: Tire Distribution STAFF REPORT A. Public Works Issues: 1. The proposed south driveway is not a part of this variance application and is not being reviewed by staff for comments to Board of Adjustments. A separate variance is required to be obtained from the Board of Directors for the driveway location. 2. No. Comment on Street buffer. B. Landscape and Buffer Issues: Site plan must comply with the City's minimal landscape/buffer ordinance requirements. Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-ways. Provide screening shrubs with an average linear spacing of not less than three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property or the right-of-way of any street. This strip shall be at least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting strip. JUNE 26, 2017 ITEM NO.: 5 (CON'T.) Z-9223 For parking areas with twelve or more spaces eight percent (8%) of the vehicular use area must be designated for green space; this green space needs to be evenly distributed throughout the parking area(s). The minimum size of an interior landscape area shall be one hundred fifty (150) square feet for developments with one hundred fifty (150) or fewer parking spaces. Trees shall be included in the interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces. Building landscape areas shall be provided between the vehicular use area used for public parking and the general vicinity of the building. These shall be provided at the rate equivalent to planter strip three (3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be planted in the building landscape areas for each forty (40) linear feet of vehicular use area abutting the building. An automatic irrigation system to water landscaped areas shall be required for developments for one (1) acre or larger. The development of two (2) acres or more requires the landscape plan to be stamped with the seal of a Registered Landscape Architect. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. C. Staff Analysis: The 1-2 zoned property located at 6201 Patterson Road is occupied by a one-story office/warehouse commercial structure. The property is located on the east side of Patterson Road, north of W. 65th Street. A paved parking lot is located between the building and Patterson Road. Two (2) driveways from Patterson Road serve the property. A new building addition is in the process of being constructed within the south half of the property. The new addition will be a one-story addition to the existing office/warehouse structure, as noted on the attached site plan. Paved parking and drive areas will be located along the west and south sides of the new building addition. A new driveway from Patterson Road will be located at the southwest corner of the property. The applicant is proposing a 25 foot street buffer along the Patterson Road frontage. Section 36-522(b)(4)b. of the City's Zoning Ordinance requires a minimum street buffer width of 50 feet for this 1-2 zoned lot. Therefore, the applicant is requesting a variance to allow the reduced street buffer. JUNE 26, 2017 ITEM NO.: 5 (CON'T.) Z-9223 Staff is supportive of the requested buffer variance. Staff views the request as reasonable. The applicant is requesting the reduced street buffer width to allow extra space for large truck maneuvering and parking between the building and the front (west) property line. The new building will have truck access doors along the building's west fagade. The proposed 25 foot wide street buffer will be equal to or greater than many other street buffers along Patterson Road to the north and south, within this industrial district. The 25 foot wide street buffer will be required to be landscaped as per City code. Staff believes the proposed reduced buffer will have no adverse impact on the adjacent properties or the general area. D. Staff Recommendation: Staff recommends approval of the requested variance for reduced street buffer, subject to compliance with the following conditions: 1. Compliance with the Public Works requirements as noted in paragraph A. of the staff report. 2. Compliance with the Landscape and Buffer requirements as noted in paragraph B. of the staff report. 3. The street buffer area must be landscaped as per City code. BOARD OF ADJUSTMENT (June 26, 2017) The applicant was present. There were no objectors present. Staff presented the item and a recommendation of approval as outlined in the "staff recommendation" above. There was no further discussion. The item was placed on the consent agenda and approved as recommended by the vote of 4 ayes, 0 noes and 1 absent. 3 1Y7/" RLAR ENGINEERING INC_ Michael P. Marlar, P.E., PLS I\ABear Davidson, EI CortsulfirW x`&41 Euganeers & Luracl Surveyors Sarah waggoner a = 5318 John F. Kennedy Boulevard Jason Bouwknegt INCORPORATED North Little Rock, Arkansas 72116 lack Fleming, Hydrologist May 23, 2017 Mr. Monte Moore x-2-3 City of Little Rock Planning and Development 723 West Markham Little Rock, Arkansas 72201 RE: Gateway Tire 6201 Patterson Road Little Rock, AR Dear Mr. Moore, On behalf of Gateway Properties of Little Rock AR, LLC, Marlar Engineering is submitting for review the enclosed application for a zoning variance regarding the street buffer provisions of Section 36-522-b4b of the Little Rock Code of Ordinances in relation to the ongoing expansion of the Gateway Tire facility at 6201 Patterson Road. Section 36-522-b4b of the Little Rock Code of Ordinances requires a street buffer equal to six percent of the average depth of the lot but no more than SO'. Because the average depth of the property in question is 1033 feet, the code would require a street buffer of 50' for the expansion of the Gateway Tire facility. Marlar Engineering requests that the Board of Adjustment grant relief from this requirement for the expansion of the Gateway Tire facility to allow a street buffer of 25'. Because of the existing structure on site, and the desire to utilize the existing entrance drive from Patterson Road, a 50' street buffer would greatly decrease the mobility for truck traffic across the site. The proposed expansion includes 8 new truck docks on the west building front. The full street buffer of 50' limits truck turning movements and would greatly decrease the ability of the warehouse facility to operate efficiently as designed. Also, a 25' street buffer is more consistent with the street buffer of the existing facility as well as with adjacent properties along Patterson Rd. The street buffer of the existing Gateway Tire is approximately 26'. The property to the south has an existing street buffer of approximately 25'. The properties on the west side of Patterson Road have street buffers ranging from approximately 0' to 20'. in order to allow the Gateway Tire facility to continue efficient operations after the expansion and in order to maintain consistency in appearance along Patterson Road, Marlar Engineering requests on behalf of Gateway Properties of Little Rock, LLC that the Board of Adjustment grant a variance to allow for a 25' street buffer at the expansion of the Gateway Tire facility at 6201 Patterson Road in Little Rock. Sincerely, Marlar Engineering Co., Inc. Bear Davidson, EI Project Engineer Attached: Application for Variance Site Plan 0A Site Survey 044041 PHONE (501) 753-1987 FAX (501) 753-1993 WWW.MARLAR-ENG.COM $4 00. JUNE 26, 2017 ITEM NO.: 6 File No.: Z-9224 Owner: Todd and Stephanie Stewart Applicant: Tom Fennell, Fennell Purifoy Architectsts Address: 5423 Hawthorne Road Description: Lot 7, Block 9, Newton's Addition Zoned: R-2 Variance Requested: Variances are requested from the area provisions of Sections 36-254 and 36-156 to allow a new residence with reduced side setback and a new accessory structure with reduced street side setback and increased rear yard coverage. Justification: The applicant's justification is presented in an attached letter. Present Use of Property: Single Family Residential Proposed Use of Property: Single Family Residential STAFF REPORT Public Works Issues: 1. If an awning, covered parking, or other obstructions are proposed within the right- of-way, a franchise permit is required to be obtained for those improvements and should be shown on plan. Buildinq Codes Comments: The required fire separation distance (building to property line) prescribed by the building code terminates at five (5) feet. Buildings are allowed to be closer than five (5) feet if they have properly constructed fire walls which provide the requisite one (1) hour fire resistance rating. When buildings are five (5) feet or more from the property line, the requirement no longer applies to the wall itself, only the projection such as eaves or overhangs. Openings such as doors and windows are limited when the exterior wall is three (3) feet from the property line, and are prohibited when the exterior wall is less than three (3) feet from the line. There is no restriction on openings when the exterior wall is more than three (3) feet from the property line. Contact the City of Little Rock Building Codes at 371-4832 for additional details. JUNE 26, 2017 ITEM NO.: 6 (CON'T.) Z-9224 C Staff Analysis: The R-2 zoned property at 5423 Hawthorne Road is occupied by a one-story frame single family residence. The property is located at the southeast corner of Hawthorne Road and N. Polk Street. A two—car wide driveway is located at the southwest corner of the property. A circular driveway is located along the west (N. Polk Street) property line. The applicant proposes to remove the existing house and construct a new two-story single family residence, as noted on the attached site plan. The new structure will be located 25 feet back from the front (north) property line and 35 feet back from the rear (south) property line. The main body of the structure will be located five (5) feet from the east and west side property lines. Approximately 30 feet of a wrap-around porch will be located on the west side property line. The porch will be unenclosed on its north, east and west sides. The applicant also proposes to construct a two-story detached garage structure within the rear yard area, at the southwest corner of the lot. The accessory structure will be located three (3) feet from the rear (south) property line, five (5) feet from the west (street side) property line and 21 feet from the east side property line. The accessory structure will be separated from the principal structure by eight (8) feet. The accessory structure will have a rear yard coverage of 42 percent (rear 25 feet of the lot). Section 36-254(d)(2) of the City's Zoning Ordinance requires a minimum side setback of five (5) feet for the principal structure on this lot. Section 36-156(a)(2)c. requires a minimum street side setback of 15 feet for the accessory structure. Section 36-156(a)(2)c. also requires a maximum rear yard coverage of 30 percent of the rear 25 feet of the lot. Therefore, the applicant is requesting variances from these ordinance requirements to allow the porch section of the house with a reduced side setback and the accessory structure with a decreased street side setback and increased rear yard coverage. Staff is supportive of the requested side setback and rear yard coverage variances. Staff views the request as reasonable. N. Polk Street has a rather wide right-of- way of 80 feet. The standard residential right-of-way width is 50 feet. Therefore, 15 additional feet of right-of-way exists on this side of the street. The applicant could have applied to abandon the extra 15 feet of right-of-way, thereby moving the side property line 15 feet to the west. This would have allowed the house footprint to be moved approximately 8.5 feet to the west, eliminating the side setback variance for the accessory building and reducing the rear yard coverage variance. Staff feels that the proposed site plan is a good alternative to abandoning the excess right-of-way. The proposed setbacks and overall coverage proposed will not be out of character with other properties in this neighborhood. Staff believes the new residence and accessory garage structure will have no adverse impact on the adjacent properties or the general area. 2 JUKE 26, 2017 ITEM NO.: 6 (CON'T.) Z-9224 D. Staff Recommendation: Staff recommends approval of the requested side setback and coverage variances, subject to the following conditions: 1. Compliance with the Public Works requirement as noted in paragraph A. of the staff report. 2. Compliance with the Building Codes requirements as noted in paragraph B. of the staff report. 3. The portion of the porch which extends into the required side setback must remain unenclosed. 4. No portion of the porch, including overhang, may extend beyond the west side property line. 5. In the future if the existing circle driveway is proposed to be removed, modified, or improved, a franchise permit application must be provided to the Little Rock Public works Department for review and approval. (BOARD OF ADJUSTMENT (June 26, 2017) The applicant was present. There were no objectors present. Staff presented the item and a recommendation of approval as outlined in the "staff recommendation" above. There was no further discussion. The item was placed on the consent agenda and approved as recommended by the vote of 4 ayes, 0 noes and 1 absent. IIAAMI'11111_:��, V ARCHITECTS 100 Morgan Keegan Drive, Suite 320 • Little Rock, Arkansas 72202 T 501,372.6734 • F 501.372.6736 - www.fennelipurifoy.com May 23, 2017 Little Rock Board of Adjustment Department of Planning and Development 723 W. Markham St. Little Rock, Arkansas 72201 Re: Application for Variance from the Board of Adjustment 5423 Hawthorne Road, Little Rock, Arkansas Dear Staff: The owner of 5423 Hawthorne wishes to apply for a variance to eliminate the side yard easement to zero on the west (Polk Street) side of their property. They have a narrow corner lot on Polk Street that prevents them from building an adequate sized house on the lot given the setback on that side. Polk Street has an extra wide right-of-way due to the historic planning for a streetcar line that was never built. Because of the wide street right- of-way, there is an effective setback even at the property line which is why a variance is being requested. Several lots in this area have been granted setback variances for similar conditions. We appreciate your consideration for this request. Thank you, Tom Fennell AIA Fennell Purifoy Architects Owner's Agent for Todd and Stephanie Stewart 0 JUNE 26, 2017 ITEM NO.: 7 File No.: Owner: Applicant: Address: Description: Zoned: Variance Requested: Justification: Present Use of Property Z-9225 615 Main, LLC Li Zhang and Rachelle Branca 611 Main Street East side of Main Street, between E. 6th and E. 7th Streets UU A variance is requested from the outdoor dining provisions of Section 36-342.1 to allow an outdoor dining area which extends into the public right-of-way. The applicant's justification is presented in an attached letter. Mixed Use Building Proposed Use of Property: Restaurant with Outdoor Dining STAFF REPORT a Public Works Issues: The latest Main St. Project shows the existing trees to be removed and replaced with 2 rain gardens. The outer edge of the railing should be modified to extend no more than 8 ft. 11 inches from the face of building and leave at least 3 ft. 9 inches of clear unobstructed pedestrian path between the railing and rain garden. Staff Analysis: The UU zoned property at 611 Main Street is occupied by a two-story brick and frame commercial building. The property is located on the east side of Main Street, between E. 6th and E. 7th Streets. A wide sidewalk area is located between the building and Main Street. A paved alley is located along the rear (east) property line. The Tree Fold Noodles restaurant will occupy a portion of the building's ground floor. As part of the restaurant occupancy an outdoor dining area is proposed in front of the building, within the sidewalk area. The outdoordining area will be approximately nine (9) feet by 24 feet-5inches in size. The outdoor dining area will be on a five (5) inch high slab. It will be fenced with a 3.5 foot high decorative metal fence. The outdoor dining area will be located 5 feet — 7 inches back from an existing lamp post, 3 feet — 8 inches back from existing tree wells, and approximately 11 feet back from the curb line of Main Street. The seating area will accommodate approximately 14 seats. The inside portion of the restaurant will have 120 seats. JUNE 26, 2017 ITEM NO.: 7 (CON'T.) Z-9225 Section 36-342.1(d)(1)a.1. of the City's Zoning Ordinance states that areas of outdoor dining within the UU zoning district not be located in the public right-of-way. Therefore, the applicant is requesting a variance to allow the area of outdoor dining to be located in the public right-of-way. Staff is supportive of the requested variance to allow outdoor dining in the public right-of-way at this location. Staff views the request as reasonable. Staff's support is based on the fact that the applicant will revise the width of the outdoor dining space as required by Public Works, to be no more than 8 feet — 11 inches from the face of the building, leaving at least 3 feet — 9 inches between the railing and future rain gardens which will be constructed along Main Street in front of this building. Otherwise, the proposed area of outdoor dining will not be out of character with other outdoor dining areas within the Downtown area. Several other areas of outdoor dining exist along Main Street, as well as other areas in the general vicinity. Staff believes the proposed outdoor dining area within the public right-of-way will have no adverse impact on the surrounding properties or the general area. C. Staff Recommendation: Staff recommends approval of the requested variance to allow an outdoor dining area within the public right-of-way, subject to the following conditions: 1. Compliance with the Public Works requirement as noted in paragraph A. of the staff report. 2. A franchise permit must be obtained for the use of the right-of-way. BOARD OF ADJUSTMENT (June 26, 2017) The applicant was present. There were no objectors present. Staff presented the item and a recommendation of approval as outlined in the "staff recommendation" above. There was no further discussion. The item was placed on the consent agenda and approved as recommended by the vote of 4 ayes, 0 noes and 1 absent. 05.24.17 ZoningVarianreX litation: Cove�•Letter Three Fold Noodles and Dumpling Co., a fast -casual Chinese eatery, first opened in December 2014. After two years in operation, the restaurant will re -locate to its new home at 611 Main Street in Downtown Little Rock. The purpose behind this move is two -fold: to help continue the efforts to revitalize Main Street and to perfect Three Fold's service style and atmosphere. As part of this effort, one of Three Fold's key designs for the Main Street space include a fenced -in outdoor dining area; the goal of which is to help enliven Main Street, likewise Three Fold's customers' dining experiences. Spatially, this dining area will allow for around 14 diners, THREE FOLD and will offer a comfortable place for patrons to dine al fresco in Little NOODLES+DUMPL9NGOP Rock's Creative Corridor. The proposed dining area will extend 9 f et from, and 24 feet along the front facade. A bar counter will be attached FOOD WITH ROOTS to the length of the fence for bar seating, and small dining tables will be positioned along the facade (please refer to drawings). To cohere the fence with the classic aesthetic of 611 Main, its railings will be made of white powder -coated metal in the Chippendale style. This patio will be ADA accessible from both the inside of the restaurant space and from a gate located at the north end of the patio. The gate at the north end of the patio will connect with the ADA accessible ramp at the entrance to the 611 Main Street space. A Chippendale style handrail will be located on the north end of the ADA accesible ramp for safety purposes. The interior seating capacity of the restuarnt will be approximately 112. +501 372 1739 EAT3FOLD@GMAIL.COM 215 CENTER ST., LITTLE ROCK THREE FOLD TEAM DATE: s Q tJ 1- 2 6,)- t-) i -7 c-0 "> t- i,,\ A MEMBER L-, -7 ALLISON, FRANK LINDSEY POLK, CAROLYN SMITH, CHRISTOPHER TUCKER, ROBERT YATES, JEFF TIME IN AND TIME OUT ALLISON, FRANK LINDSEY POLK, CAROLYN SMITH, CHRISTOPHER TUCKER, ROBERT YATES, JEFF v1 AYE NAYE __,ABSENT --A&BSTAIN Meeting Adjourned -6L- P.M. JUNE 26, 2017 There being no further business before the Board, the meeting was adjourned at 2:06 p.m. Date: c