Loading...
pc_03 11 2004subLITTLE ROCK PLANNING COMMISSION SUBDIVISION HEARING SUMMARY AND MINUTE RECORD MARCH 11, 2004 4:00 P.M. I. Roll Call and Finding of a Quorum A Quorum was present being nine (9) in number. II. Members Present: Pam Adcock Gary Langlais Robert Stebbins Norm Floyd Mizan Rahman Bill Rector Jerry Meyer Fred Allen, Jr. Chauncey Taylor Members Absent: Bob Lowry Darrin Williams City Attorney: Cindy Dawson III. Approval of the Minutes of the January 29, 2004 Meeting of the Little Rock Planning Commission. The Minutes were approved as presented. LITTLE ROCK PLANNING COMMISSION SUBDIVISION AGENDA MARCH 11, 2004 I. DEFERRED ITEMS: A. Shackleford Farms Preliminary Plat (S-1408), located along the East side of Kirk Road, North of Chenal Parkway and South of Champlin Drive. A.1. A Land Use Plan Amendment (LU03-19-02) in the Chenal Planning District along the East side of Kirk Road between Chenal Parkway and Rahling Road from Single Family, Low Density Residential, Multifamily and Office to Commercial, Multifamily and Office. A.2. A Master Street Plan Amendment (MSP03-04) to remove a collector along the proposed Minor Arterial named Wellington Hills Road / Champlin Road between Rahling Road and Chenal Parkway. A.3. Rezoning from R-2/R-3/MF-6/O-2 to MF-18, O-2 to C-3, O-2 to O-3 and MF-18 to O-2 (Z-4807-E), located along the East side of Kirk Road, North of Chenal Parkway and South of Champlin Drive. B. A Land Use Plan Amendment (LU03-18-03) in the Ellis Mountain Planning District on the South side of Chenal Parkway East of the Wellington Hills Road intersection from Suburban Office to Commercial. B.1. Pinnacle Ford Long-form PCD (Z-4841-B), located South of Chenal Parkway, East of the Kanis Road intersection. C. Mabelvale Business Park and Shopping Center Revised Preliminary Plat (S-993-K), located on the South side of the I-30 Frontage Road at Mabelvale Pike. D. Plaza Subdivision Preliminary Plat (S-1413), located on the Northwest corner of Colonel Glenn Road and I-430. E. A Land Use Plan Amendment (LU04-01-01) in the River Mountain Planning District, located North of Cantrell Road at Taylor Loop Road, a change from Transitional to Commercial. E.1. Cantrell Loops Retail Center PCD – Lot 2 (Z-7022-A), located North of Cantrell Road at Taylor Loop Road. F. Rock House Short-form POD (Z-7563), located at 715 North University Avenue. G. Chenal – Highway 10 Mini-Storage Planning Commission Appeal of a Notice of Violation of the City’s Land Alteration Ordinance (NOV #208), located at 24300 Chenal Parkway. H. Z-7573 The Furniture Club Warehouse – Conditional Use Permit 6805 West 12th Street, Suite “D” Agenda, Page Two II. PRELIMINARY PLATS: 1. Otter Creek Business Park Subdivision Preliminary Plat (S-45-A-55), located on the Southwest corner of I-30 and Mabelvale West Road. 2. Otter Creek Plaza Subdivision Revised Preliminary Plat (S-45-A-56), located on the Northeast corner of Otter Creek Parkway and Stagecoach Road. 3. Little Rock Port Subdivision Tract C Area 101 Revised Preliminary Plat (S- 185-P), located North of Sloane Drive, South of Lindsey Road. 4. River Ridge Pointe Subdivision Lot 2 Replat (S-686-D), located on River Ridge Pointe. 5. Chenal Valley Phase 2 Commercial Subdivision Revised Preliminary Plat (S-867-EEEEE), located on the Southeast corner of Cantrell Road and Chenal Parkway. 6. Cantrell Loops Subdivision Revised Preliminary Plat (S-1310-B), located North of Cantrell Road at Taylor Loop Road. 7. Madison Valley Subdivision Revised Preliminary Plat (S-1409-A), located South of Taylor Loop Road on Montgomery Road. 8. Amy Ridge Subdivision Preliminary Plat (S-1417), located on the Southwest corner of Labette Drive and John Barrow Road. 9. Stalcup Subdivision Preliminary Plat (S-1418), located on the Southeast corner of Taylor Loop Road and Gooch Lane. 10. Diamond T Subdivision Preliminary Plat (S-1419), located on Crystal Valley Road approximately 1200 feet north of the east/west leg. 11. Woodland Farms Acres Subdivision Preliminary Plat (S-1420), located on the East end of Pine View Place. 12. Green Diamond Subdivision Preliminary Plat (S-1421), located on Crystal Valley Road on the north side west of Crystal Valley Cove. Agenda, Page Three III. SITE PLAN REVIEWS: 13. Little Rock Port Lease Area 3 Subdivision Site Plan Review (S-185-Q), located at 9001 Lindsey Road. 14. Chenonceau Commercial Lots 1 and 2 Subdivision Site Plan Review (S- 1065-C), located on the Southeast corner of Cantrell Road and Chenonceau Boulevard. 15. Sage Meadows Apartments Subdivision Site Plan Review (S-1229-A), located on the West side of John Barrow Road, South of Tanya Drive. 16. Black Subdivision Site Plan Review (S-1416), located at 2807 Willow Springs Road. 17. Murphy Oil Company USA Fueling Station Zoning Site Plan Review (Z- 5097-F), located on the Southeast corner of Cantrell Road and Chenal Parkway. 18. Wal-Mart Revised Zoning Site Plan Review (Z-5097-G), located on the Southeast corner of Cantrell Road and Chenal Parkway. IV. LAND USE PLAN AMENDMENTS - PLANNED DEVELOPMENTS – CONDITIONAL USE PERMITS: 19. Sage Meadows Long-form PD-R (Z-3173-C), located on the West side of John Barrow Road, South of Tanya Drive. 20. Home Depot Revised Conditional Use Permit (Z-3459-H), located on Mabelvale Plaza Drive. 21. A Land Use Plan Amendment (LU04-12-01) in the 65th Street West Planning District on the Southeast corner of Colonel Glenn Road and Shackleford Road from Light Industrial to Commercial. 21.1 Shackleford Commercial Long-form PCD (Z-5703-A), located on the Southeast corner of Colonel Glenn Road and Shackleford Road. 22. Bella Rosa Drive Long-form PCD (Z-6219-A), located on the Southwest corner of Cantrell Road and Bella Rosa Drive. 23. Gilbert Acres Subdivision Revised Short-form PD-R (Z-6376-A), located on Gamble Road, South of Stacey Lane. Agenda, Page Four IV. LAND USE PLAN AMENDMENTS - PLANNED DEVELOPMENTS – CONDITIONAL USE PERMITS: (CONT.) 24. Bowman and Kanis Retail Center Revised Long-form PCD (Z-6554-B), located on the Northwest corner of Kanis Road and Bowman Road. 25. Grace Presbyterian Church Long-form POD (Z-7225-A), located at 9301 North Rodney Parham Road. 26. Shear Magic Revised Short-form PCD (Z-7327-B), located at 1911 West 2nd Street. 27. A Land Use Plan Amendment (LU04-01-02) in the Pinnacle Planning District on the North side of Cantrell Road, West of Pinnacle Valley Road from Transition to Commercial. 27.1 Rees Development Long-form PCD (Z-7500-A), located North of Cantrell Road, West of Pinnacle Valley Road. 28. IUOE Short-form POD (Z-7579), located at 5516 West 11th Street. 29. Holleman Short-form PD-C (Z-7580), located at 4115 Baseline Road. 30. Back Short-form POD (Z-7581), located at 1111 Autumn Road. 31. Gardner Short-form PD-R (Z-7582), located at 705 Beechwood Street. 32. Marshall Short-form PD-C (Z-7583), located at 5405 Stanley Drive. 33. A Land Use Plan Amendment (LU04-18-01) in the Ellis Mountain Planning District on the North side of Kanis Road, Southeast of Pride Valley Road from Single Family to Suburban Office. 33.1 G & S Builders Short-form PD-O (Z-7584), located North of Kanis Road, Southeast of Pride Valley Road. 34. The River Tower Long-form PD-R (Z-7585), located on the Northeast corner of River Bend Road and Riverfront Drive. Agenda, Page Five V. OTHER BUSINESS: 35. Arkansas Hospice Long-form POD Time Extension Request, (Z-4175-G), located at the North end of Dover Drive, West of 36th Street. 36. Summit Mall Revised PCD Time Extension Request, (Z-4923-A), located on the Southwest corner of Shackleford Road and I-430. 37. Miller Short-form PCD Revocation Request, (Z-4454-A), located at 15122 Cantrell Road. March 11, 2004 ITEM NO.: A FILE NO.: S-1408 NAME: Shackleford Farms Preliminary Plat LOCATION: along the east side of Kirk Road, north of Chenal Parkway and south of Champlin Drive DEVELOPER: Shackleford Family LLC c/o Wingfield Martin 221 West 2nd Street, Suite 210 Little Rock, AR 72201 ENGINEER: White-Daters and Associates #24 Rahling Circle Little Rock, AR 72223 AREA: 120 acres NUMBER OF LOTS: 21 FT. NEW STREET: 4,875 LF CURRENT ZONING: O-2, MF-18, MF-6, R-3 and R-2 PLANNING DISTRICT: 19 - Chenal CENSUS TRACT: 42.10 VARIANCES/WAIVERS REQUESTED: A variance to allow double frontage lots for Lots 5 - 9. A. PROPOSAL/REQUEST: The applicant proposes to subdivide this 120-acre tract into 21 lots of various sizes based on the proposed zoning. The applicant has indicated seven lots proposed as multi-family development, ten lots proposed as office development and four lots proposed as commercial development. March 11, 2004 SUBDIVISION ITEM NO.: A (Cont.) FILE NO.: S-1408 2 The multi-family lots all will be accessed by Wellington Hills Road. The proposed lots range in size from five acres to thirty plus acres. The applicant has indicated four commercial lots. The lots are proposed adjacent to the proposed extension of Arkansas Systems Drive. The proposed office lots range in size from one-half acre to twenty-one plus acres. There are nine lots fronting Kirk Road, which average one hundred twenty-five feet by one hundred eight-four feet and a larger tract (21+ acres) proposed to front Wellington Hills Road. The applicant has indicated a new commercial street extending from Arkansas System Drive to connect to a proposed minor arterial Wellington Hills Road with for lots proposed as commercial development. The applicant is requesting a variance to allow double frontage lots for Lots 5 – 9. The lots are proposed to front Wellington Hills Road and will also abut Kirk Road. The applicant has also filed a several requests for the area in association with an overall development plan. There is a request to rezone several parcels within the plat boundary (Z-4807-E – Item 6.3) along with a request to amend the City’s Future Land Use Plan (LU03-19-02 – Item #6.1). The applicant has also filed a request to amend the City’s Master Street Plan to remove three collectors along the proposed minor arterial named Wellington Hills Road/Champlin Road between Rahling Road and Chenal Parkway (File No. MSP03-04 – Item #6-2). Please see each of the individual items for specifics on each request. B. EXISTING CONDITIONS: The site is a vacant gently sloping; site the remnant of the old Shackleford Dairy Farm. The area to the west is developing as office and commercial uses abutting Chenal Parkway and the area to the southwest along Kirk Road has not redeveloped. To the east of the site are vacant lands owned by the developers of the Villages of Wellington. North of the site are the Carrington Park Apartments (zoned MF-18) and a vacant O-3 zoned tract. To the northwest is a MF-18 zoned tract, which the Commission recently approved for a multiple building site plan review for a multi-family development. South of the site is a PD-C zoned site for Riverside Acura automobile dealership. Small scale office development is occurring along Kirk Road on the east side. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents or property owners concerning the proposed development. The Parkway Place Property Owners Association and the St. Charles Property Owners Association March 11, 2004 SUBDIVISION ITEM NO.: A (Cont.) FILE NO.: S-1408 3 and all abutting property owners of the site were notified of the proposed plat additional notes were sent for the rezoning and plan amendment request. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. The plat proposal for extending and improving the minor arterial, Wellington Hills Road, and the collectors, Wellington Village Road, Systems Drive and Kirk Road south of Systems Drive is acceptable. 2. North of Systems Drive, boundary street improvements would also be required for the remainder of the Kirk Road right-of-way, or a right-of-way abandonment should be filed as a part of this plat. 3. The plat should show access to the O-2 zoned property just north of the Arkansas Systems property. The current plan calls for the extension of Wellington Village Road to meet a cul-de-sac on that property. 4. Public Works has no objection to the removal of the collector street from the Master Street Plan that was to link Kirk Road to Wellington Hills Road. 5. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Site grading and drainage plans will need to be submitted and approved prior to the start of construction. 6. Storm water detention ordinance applies to this property. Identify whether storm water detention facilities are to be provided on a regional basis or for each individual lot. 7. Provide the directional flow and all storm water flows (Q) entering and leaving the property. Easements are required for all drainage areas. 8. Prepare a letter of pending development addressing street lights as required by Section 31-403 of the Little Rock Code of Ordinance. Contact Traffic Engineering at (510) 379-1813 (Steve Philpott) for more information regarding street light requirements. 9. Driveway locations and widths do not meet the traffic access and circulation requirements of Sections 30-43 and 31-210. This applies to Lots 8 through 21 and Lot 23. The lot widths must be increased to the ordinance standard of at least 125-feet if shared driveways are platted or 250-feet for individual driveways. The width of driveways must not exceed 36-feet. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer main extension required, with easements, if service is required for the project. Contact the Little Rock Wastewater Utility at 688-1414 for additional details. Entergy: No comment received. March 11, 2004 SUBDIVISION ITEM NO.: A (Cont.) FILE NO.: S-1408 4 Center-Point Energy: Approved as submitted. SBC: A ten foot easement is required around the perimeter of the site as well as adjacent to all proposed roadways. Contact SBC at 373-5112 for additional information. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. Water main extensions will be required for this project. A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact Central Arkansas Water at 992-2438 for additional details. Fire Department: Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional details. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: (November 6, 2003) Mr. Joe White of White-Daters and Associates was present representing the request. Staff presented an overview of the proposed project indicating the development also included a request for rezoning, an amendment to the Future Land Use Plan and a request to amend the Master Street Plan. Staff noted there were additional items necessary on the proposed preliminary plat to complete the review. Staff stated the source of title along with a phasing plan should be included. Staff stated the proposed lots along Kirk Road should be reconsidered. Staff stated with the current Master Street Plan there was a proposed collector street crossing a few of the lots, which would result in the lots being unbuildable. Staff also noted the proposed lots did not allow for proper driveway spacing per the Subdivision Ordinance or the Master Street Plan. Staff suggested the applicant review the proposed design in this area. March 11, 2004 SUBDIVISION ITEM NO.: A (Cont.) FILE NO.: S-1408 5 Staff also questioned the dedication of right-of-way for the large O-2 zoned parcel to the north. Staff requested the applicant provide right-of-way extending Kirk Road to the north to allow access to the site. Mr. White stated the property owner of the un-served tract to the north would have access from Chenal Parkway through a tract of land extending between the Villages at Rahling Road and the MF-18 zoned parcel. Public Works comments were addressed. Staff requested the applicant provide the directional flow and all storm water flows entering and leaving the property. Staff requested the applicant to provide storm water detention facilities and the plans if the detention would be on-site or provided regionally. Mr. White stated he would address this issue upon resubmission. There being no further items for discussion, the Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plan to staff addressing most of the issues raised at the November 6, 2003 Subdivision Committee meeting. The applicant has indicated detention will be provided on a regional basis. The applicant has also indicated the final platting of the lots will be market driven. The applicant has revised the plan to meet the minimum requirements for driveway spacing for the proposed lots fronting Kirk Road. The applicant has indicated the lots will be 125 feet by 184 feet and contain a minimum of 23,000 square feet. The applicant is requesting the lots be zoned as O-3, which typically requires a minimum lot area of 14,000 square feet. The applicant has indicated a large tract (Lot 20), the majority of which is currently zoned O-2 as a separate lot. The typical minimum requirement for an O-2 zoned parcel is a minimum of two acres and two hundred feet of frontage. The proposed parcel is more than adequate to meet the minimum requirements. The applicant has not indicted a collector street currently shown on the Master Street Plan, which is proposed to extend from Kirk Road to Wellington Hills Road through Lot 20. Staff feels the proposed collector should be indicated on the preliminary plat and the proposed lots abutting Kirk Road be modified to allow for the street location (Lots 10 – 19). Staff feels once the street is indicated on the proposed preliminary plat the number of lots will be reduced. Staff feels the subdivision of the smaller lots in this area is premature. Staff feels the applicant should leave this area with the larger tract and when development is secured revise the preliminary plat in accordance with the development’s needs. There is also the issue related to the proposed collector street shown on the City’s Master March 11, 2004 SUBDIVISION ITEM NO.: A (Cont.) FILE NO.: S-1408 6 Street Plan. Staff feels this street is critical until a development plan has been submitted for the proposed 21 acre tract of office zoning. The applicant has indicated an extension of Arkansas Systems Drive to Wellington Hills Road. The four lots abutting this new street are proposed as commercial uses. The applicant has indicated lot sizes ranging from 0.88 acres to 1.63 acres. The proposed lots meet the typical minimum requirement for commercially zoned property (C-1 – 7,000 square feet and C-3 – 14,000 square feet). The remainder of the lots proposed will take access from Wellington Hills Road. The proposed parcels range in size from five plus acres to twenty plus acres. The applicant has indicated multi-family zoning on these lots. The acreage is more than adequate to meet the typical minimum requirements for site area. The applicant has not indicated access to the northern O-2 zoned parcel (north of Arkansas System). Staff has requested the applicant extend Kirk Road to the north to access this site. Arkansas Systems has committed to one-half street improvements to Kirk Road to their northern property line. Staff feels this owner should also construct one-half street improvements in this area to match the improvements to the west. Staff feels there are many outstanding issues associated with the proposed request. There are unresolved street issues associated with the request. and staff feels the proposed lots abutting Kirk Road premature. I. STAFF RECOMMENDATION: Staff recommends denial of the request as filed. PLANNING COMMISSION ACTION: (DECEMBER 4, 2003) Mr. Joe White was present representing the request. There were several registered objectors present. Staff stated the applicant had requested this item be deferred to the January 29, 2004 Public Hearing. Staff stated they were supportive of the request. There was no further discussion of the item. The item was placed on the consent agenda for deferral. The motion carried by a vote of 11 ayes, 0 noes and 0 absent. March 11, 2004 SUBDIVISION ITEM NO.: A (Cont.) FILE NO.: S-1408 7 PLANNING COMMISSION ACTION: (JANUARY 29, 2004) Mr. Joe White was present representing the request. There were no registered objectors present. Staff stated the applicant submitted a letter requesting the item be deferred to the March 11, 2004 Public Hearing. Staff stated they were supportive of the request. There was no further discussion of the item. The item was placed on the consent agenda for deferral. The motion carried by a vote of 11 ayes, 0 noes and 0 absent. PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Joe White was present representing the request. There were registered objectors present. Staff stated the applicant had submitted a letter dated March 1, 2004 requesting the item be deferred to the April 22, 2004 Planning Commission Public Hearing. Staff stated the deferral request would require a waiver of the By-Laws related to the number of allowed deferrals. Staff stated the applicant had notified property owners as required by the Planning Commission By-Laws of the deferral request. Staff stated they were supportive of the By-Law waiver and the deferral request. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: A.1 FILE NO.: LU03-19-02 Name: Land Use Plan Amendment - Chenal Planning District Location: North of Chenal Parkway, South of Rahling Road Request: Area 1: Office and Multifamily to Commercial. Area 2: Commercial to Office. Area 3: Multifamily to Office. Area 4: Single Family to Park / Open Space. Area 5: Single Family to Public Institutional. Area 6: Low Density Residential to Multifamily. Area 7: Single Family to Multifamily. Source: Joe White, White - Daters & Associates PROPOSAL / REQUEST: Land Use Plan amendment in the Chenal Planning District from Office, Multifamily, Low Density Residential, and Single Family to Office, Commercial, and Multifamily. The Office category represents services provided directly to the consumers (e.g., legal, financial, medical) as well as general offices, which support more basic economic activities. The Commercial category includes a broad range of retail and wholesale sales of products, personal and professional services, and general business activities. Commercial activities vary in type and scale, depending on the trade area that they serve. The Multifamily category accommodates residential development of ten (10) to thirty-six (36) dwelling units per acre. The applicant wishes to develop the property for commercial, office, and multifamily uses. Prompted by this Land Use Amendment request, the Planning Staff expanded the area of review to include an area shown as Low Density Residential at the end of Wellington Hills Road to recognize existing zoning and the proposed multi- family development. In addition, the application was expanded to include a change from Single Family to Park / Open Space at the northwest corner of Wellington Hills and Wellington Village Road (Area 4), and a change from Single Family to Public Institutional on the west side of Wellington Village Road (Area 5) to recognize existing zoning and the uses. The Park / Open Space category includes all public parks, recreation facilities, greenbelts, flood plains, and other designated open space and recreational land. The Public Institutional category includes public and quasi-public facilities that provide a variety of services to the community such as schools, libraries, fire stations, churches, utility substations, and hospitals. March 11, 2004 SUBDIVISION ITEM NO.: A.1 (Cont.) FILE NO.: LU03-19-02 2 EXISTING LAND USE AND ZONING: The applicant’s property is about 120.0 acres ± of pastureland. The portion of the applicant’s property on the west side of the Champlin / Wellington Hills Proposed Minor Arterial is zoned R-2 Single Family at the end of Champlin Drive, MF-18 Multifamily at the end of Kirk Road, O-2 Office and Institutional along Kirk Road, and MF-18 at the south end of the applicant’s property. The east side of the Proposed Minor Arterial is zoned R-2 at the end of Champlin Drive, R-3 Single Family in the middle, and MF-6 Multifamily at the end of Wellington Hills Road. The expanded area consists of vacant land zoned MF-18 near the end of Wellington Hills Road, a retention pond at the northwest corner of Wellington Hills and Wellington Village Road zoned R-2, and property zoned R-2 with a Conditional Use Permit for a church on the west side of Wellington Village Road. The vacant land neighboring the study area beginning at the end of Champlin Drive is zoned MF-18, R-2, and MF-6. The property wrapping around the east side of the expanded area consists of houses located in the vicinity of Wellington Hills Road zoned R-2. The property on the east side of the intersection of Wellington Hills and Wellington Village Roads consist of a church zoned R-2 with a C.U.P. and vacant land at the northeast corner zoned O-1 Quiet Office. The south side of Wellington Hills Road includes vacant land zoned C-1 Neighborhood Commercial at the Wellington Village intersection, plus offices and a radio station zoned Planned Office Development at the end of Wellington Hills. The land to the south along Chenal Parkway includes a church zoned R-2 with a C.U.P. at Kanis Road, and an automobile dealership zoned Planned Development - Commercial at Kirk Road. The property to the west along Kirk Road consists of a convenience store zoned C-3 General Commercial at Chenal Parkway, offices and vacant land zoned O-2 along the west side of Kirk Road on both sides of Systems Drive, and vacant land zoned MF-18 on the south side of Rahling Road at Chenal Valley Drive. A small parcel of vacant land zoned O-3 is located north of the applicant’s property on the end of Champlin Drive on the west side. FUTURE LAND USE PLAN AND RECENT AMENDMENTS: On June 17, 2003 multiple changes were made from Office, Multifamily, and Single Family to Multifamily and Low Density Residential along the south side of Rahling Road at Chenal Valley Drive within a 1 mile radius of the current study area, which includes some of the property addressed by this amendment, and resulted in the current Future Land Uses shown for the study area to accommodate proposed development and recognize existing conditions. March 11, 2004 SUBDIVISION ITEM NO.: A.1 (Cont.) FILE NO.: LU03-19-02 3 On September 18, 2001 a change was made from Single Family, to Neighborhood Commercial and Office on Rahling Road at Chenal Valley Drive and Champlin Drive about 1/10 of a mile north of the amendment area to accommodate proposed development. On September 18, 2001 a change was made from Low Density Residential to Single Family for an area located northeast of the end of Lamarche Drive about 1 mile north of the study area to recognize existing conditions. On April 17, 2001 a change was made from Single Family, Multifamily, and Park/Open Space to Community Shopping on Rahling Road & Chenal Parkway about ¼ of a mile west of the study area to accommodate proposed development. On January 4, 2000 a change was made from Office to Mixed Office Commercial at 15500 Chenal Parkway about 1/10th of a mile southwest of the amendment area to accommodate proposed development. The portion of the applicant’s property on the west side of the Champlin / Wellington Hills connection is shown as Multifamily, Office and Commercial. The land between the area shown as Office and the Proposed Minor Arterial is shown as Multifamily. The east side of the applicant’s property is shown as Single Family to the north and Low Density Residential to the south. The expanded area is shown as Low Density Residential at the end of Wellington Village Road, Single Family at the northwest corner of the Wellington Hills / Wellington Village intersection, and along the west side of Wellington Village Road. The neighboring property north of the study area is shown as Office and Multifamily at the end of Champlin Drive. The land wrapping around the east side of the expanded study area is shown as Single Family. The intersection of Wellington Hills and Wellington Village is shown as Public Institutional on the east side of Wellington Village and Suburban Office at the corner. The land on the south side of Wellington Hills is shown as Neighborhood Commercial at Wellington Village Road and Suburban Office at the end of Wellington Hills. The property to the south along Chenal Parkway is shown as Public Institutional at the intersection of Kanis Road and Commercial from Kanis to Kirk Road. The land to the west is shown as Commercial at the Chenal / Kirk intersection and Office along the west side of Kirk Road. The land at the northwest corner of the study area is shown as Multifamily. MASTER STREET PLAN: Champlin Drive / Wellington Hills Road is shown as a Minor Arterials. The Champlin end intersecting Rahling Road is built to a 5-lane standard while the March 11, 2004 SUBDIVISION ITEM NO.: A.1 (Cont.) FILE NO.: LU03-19-02 4 Wellington Hills segment is built to a 4-lane standard with a raised median. A Proposed Collector Street is shown to link Wellington Village Road to the Champlin / Wellington Hills Proposed Minor Arterial. The completed portion of Wellington Village is classified as a Collector Street built to Collector standards. A second Proposed Collector Street will link Systems Drive from Kirk Road to the Champlin / Wellington Hills Proposed Minor Arterial. A third Proposed Collector Street will link Kirk Road to the Champlin / Wellington Hills Proposed Minor Arterial and is the subject of a Master Street Plan Amendment on this agenda. There are no bikeways shown that would be affected by this amendment. PARKS: The Little Rock Parks and Recreation Master Plan of 2001 shows a Potential Greenbelt along Rock Creek in the median of Chenal Parkway within an eight block walking distance south of the application area. The plan is to develop the median of Chenal Parkway as a linear park and will include the construction of the Class I bikeway shown on the Master Street Plan. Since this amendment covers a large area, the northern portions of the study area are located in a Service Deficit Area and would require the development of park and open space facilities to serve future developments. HISTORIC DISTRICTS: There are no historic districts that would be affected by this amendment. CITY RECOGNIZED NEIGHBORHOOD ACTION PLAN: The property under review is not located in an area covered by a City of Little Rock recognized neighborhood action plan. ANALYSIS: Area 1: (Office & Multifamily to Commercial) This change would introduce an area of Commercial that would provide land to serve the offices to the west and residential areas to the east and significantly increase the potential intensity of development that could occur in the neighborhood. The location of this area between non-residential uses to the west and residential uses to the east could provide a focal point for the neighborhood as a center of activity that could serve both of the neighboring uses. However, this change would place an inappropriately high intensity of commercial uses in an area that would be more appropriately served with less intense commercial activity. The Commercial land use category would allow uses that would not provide support services to the nearby office areas during business hours and uses that would have adverse March 11, 2004 SUBDIVISION ITEM NO.: A.1 (Cont.) FILE NO.: LU03-19-02 5 impacts on the neighboring residential areas. The adverse affects resulting from increased traffic, noise, and visual impacts would have a greater negative impact on the residential areas to the east while leaving the non-residential areas to the west relatively non-disturbed. If the proposed change to Multifamily in Areas 6 is approved, the Multifamily designation for those areas could provide a transition from the non-residential areas to the west and the less intense Low Density Residential. If the change for Area 6 is not approved, a change to Commercial in Area 1 would place a conflicting use adjacent to the area shown as Low Density Residential. At this time all of the areas providing land for retail developments are located at along Chenal Parkway and Rahling Road. The closest land to the study areas shown for non-residential uses consists of the areas shown as Office, located to the west. This change would provide vacant land for new retail development on Champlin / Wellington Hills located about halfway from the areas currently shown for retail uses. Area 2: (Commercial to Office) This change would reduce the amount of land shown as Commercial at the northeast corner of the Chenal Parkway / Kirk Road intersection. The area proposed for Office would be small enough that by itself would not require an amendment. However, this amendment is adjacent to Area 3, which for a proposed change from Multifamily to Office. The change from Commercial to Office in Area 2 is essentially an expansion for the proposed change in Area 3. The Commercial shown at the intersection of Kirk Road fronts and is accessed by Chenal Parkway. Kirk Road would front area #2. Area 3: (Multifamily to Office) This conversion would increase the area shown as Office and allow the assembly of land parcels suitable for larger office development between Kirk Road and the Champlin / Wellington Hills Connection. This alteration would allow a greater continuity of uses by establishing non- residential uses along the west side of the Champlin / Wellington Hills connection south of the Systems Drive extension. This modification would also be compatible with the Suburban Office to the east and the Commercial and Public Institutional to the south. In addition, a change to Office would provide double frontage for office developments between Kirk Road and the Champlin / Wellington Hills connection. The area shown as Office between Kirk Road and Chenal Parkway is near build-out. A change to Office would provide more vacant land allow more future office development in the neighborhood. Similar to the change proposed for Area 1, the proposed change in Area 3 could have adverse affects resulting from increased traffic, noise, and visual impacts would have a potential negative impact on the residential areas to the east. If the proposed changes to Multifamily in Areas 6 are approved, the Multifamily designation for those areas could provide a transition from the non-residential areas to the west and the less intense Low Density Residential. As in Area 1, if the changes for Area 6 is not approved, a change to Office in Area 3 would place a conflicting March 11, 2004 SUBDIVISION ITEM NO.: A.1 (Cont.) FILE NO.: LU03-19-02 6 use adjacent to the area shown as Low Density Residential. The proposal for Area 3 would also increase the area of non-residential, requiring people live further from the proposed commercial and offices uses, further segregating uses. A change to Office in Area 3 would allow for a campus type office development. Area 4: (Single Family to Park / Open Space) A change to Park / Open Space would recognize existing conditions at the northwest corner of the Wellington Hills / Wellington Village intersection. Park / Open Space would also serve to protect the integrity of the retention pond located at the northwest corner of Wellington Hills and Wellington Village and preserve the hillside. A change to Park / Open Space would also buffer the Single Family uses to the north from the non-residential uses located to the south. In addition, Park / Open Space would also provide a transition along the north side of Wellington Village from the Suburban Office and Commercial shown south of Wellington Village and the residential areas to the west. This change along with the proposed changes for Areas 5 and 6 would buffer the less intense residential uses to the north from the more intense nonresidential uses to the south. As an existing use, or neighborhood amenity, a change to Park / Open Space should help re-enforce this area as an open space amenity to the neighborhood. Area 5: (Single Family to Public Institutional) The Public Institutional category would recognize the church and provide a transition along the west side of Wellington Village into the residential areas to the north from the non-residential areas to the south. A change to Public Institutional is intended to serve the civic needs of the neighborhood. A change to Public Institutional in Area 5, along with a change to Park / Open Space in Area 4, would complement the Suburban Office and Public Institutional on the east side of Wellington Village to create a gateway into the neighborhood. As in Area 4, this change would recognize an existing use, or neighborhood amenity, there would be little negative impact on the neighborhood as long as the present use of the property remains unaltered. However, unlike the property in Area 4, this property could be more easily converted from its present use to either residential or non-residential uses. Area 6: (Low Density Residential & Single Family to Multifamily) A change to Multifamily would eliminate the LDR fronting Wellington Hills Road and provide Multifamily along the east side of the proposed Champlin / Wellington Hills link. Although a change to Multifamily could also place a higher density of residential uses next to less intense LDR, the remaining area shown as LDR could provide a transition between densities of residential development. This change would also buffer the non-residential areas to the west from the residential areas to the east. This proposal along with the proposed change in Area 7 would create a continuous area of Multifamily from Area 4 and the Multifamily shown at the intersection of Rahling Road and Chenal Valley Drive. The change in Area 6 March 11, 2004 SUBDIVISION ITEM NO.: A.1 (Cont.) FILE NO.: LU03-19-02 7 could also provide a transition of use intensity resulting from the proposed change to Commercial in Area 1 from the less intense residential areas to the east. However, due to the possible densities of development in an area shown as Multifamily (up to 36 dwelling units per acre), a change to Multifamily in Area 6 compared to the possible densities in an area shown as LDR (as low as 6 dwelling units per acre), a large difference in densities could occur in developments located next to each other. Area 7: (Single Family to Multifamily) A change to Multifamily would link a change to Multifamily in Area #6 to the Multifamily shown at the end of Champlin Drive. The proposed change for Area #7 would also establish Multifamily uses on both sides of the Champlin / Wellington Hills connection between the Systems Drive extension and the proposed Wellington Village Road extension. However, as in Area 6, this could place a higher density of residential uses next to less intense residential uses without a buffer between densities of residential development. A change to Multifamily at this location would increase the area already shown as Multifamily at the end of Champlin Drive. A change to Multifamily in Area 7 could result in a greater difference between developments located in Area 7 and the lower densities allowed in the areas to the east. Multifamily developments located in Area 7 would also occur adjacent to Single Family developments that would occur in conjunction with an extension of the Wellington Village Road Collector Street. In summary, the changes proposed would establish Champlin / Wellington Hills as a boundary between residential and non-residential uses located south of systems drive. The changes for Areas 1, 2, and 3 would add place Commercial uses inside the neighborhood, expand the area shown as Office, and remove Multifamily from the west side of Champlin / Wellington Hills. The changes for Areas 4 and 5 would complement the land shown as Suburban Office and Public Institutional at the intersection of Wellington Hills and Wellington Village to establish a transition of uses along Wellington Village and create an entrance into the residential areas to the north. The change for Areas 6 would complement the changes proposed for Areas 1 and 3 to establish Champlin / Wellington Hills as a boundary between residential and non-residential uses. The change in Area 7 would increase the area shown as Multifamily currently shown at the end of Champlin Drive. These changes add a new area shown as Commercial with a slight reduction in the Office and Multifamily. The loss of Office and Multi-family in Area 1 would be offset by an increases in land shown as Office in Areas 2 & 3 and Multi-family for Areas 6 & 7. The changes to Office in Areas 2 and 3 also provides vacant land for Office uses in addition to the land already developed with Office uses along Chenal Parkway. A change for Area 5 would reinforce a neighborhood amenity, while both changes for Areas 4 and 5 recognize existing conditions. New Multifamily in Areas 6 & 7 would add vacant March 11, 2004 SUBDIVISION ITEM NO.: A.1 (Cont.) FILE NO.: LU03-19-02 8 land to the recent increase in Multifamily shown at the end of Champlin Drive and south of Rahling Road at Chenal Valley Drive. NEIGHBORHOOD COMMENTS: Notices were sent to the following neighborhood associations: Aberdeen Court Property Owners Association, Bayonne Place Property Owners Association, Carriage Creek Property Owners Association, Chenal Ridge Property, Du Quesne Place P.O.A., Eagle Pointe Property Owners Association, Glen Eagles Property Owners Association, Hillsborough Property Owners Association, Hunters Cove Property Owners Association, Hunters Green Property Owners Association, Johnson Ranch Neighborhood Association, Marlowe Manor Property Owners Association, Maywood Manor Neighborhood Association, St. Charles Property Owners Association, Charleston Heights/North Rahling Rd N.A., Margeaux Place Property Owners Association, and Parkway Place Property Owners Association. Staff has received one comment from area residents. The comment received was neutral. STAFF RECOMMENDATIONS: Staff believes the following changes are appropriate: Staff believes the changes in Areas 2 - 5 are appropriate to establish the Proposed Minor Arterial as a boundary between intensity of uses and to provide a transition between uses along Wellington Village Road. In area 1, a change to Neighborhood Commercial is more appropriate than a change to Commercial and would also provide small-scale goods and services to the residential areas after business hours, while providing support uses to the office areas during business hours, creating a focal point for the neighborhood. In Area 6 - 7, staff supports a change to Multi-family with the addition of a strip of Park / Open Space along the boundaries adjacent to areas shown as Low Density Residential and Single Family would be more appropriate to provide a buffer between intensity of uses. March 11, 2004 SUBDIVISION ITEM NO.: A.1 (Cont.) FILE NO.: LU03-19-02 9 PLANNING COMMISSION ACTION: (December 4, 2003) The item was placed on the consent agenda for deferral to the January 29, 2004 Planning Commission meeting. A motion was made to approve the consent agenda and was approved with a vote of 11 ayes, 0 noes, and 0 absent. PLANNING COMMISSION ACTION: (January 29, 2004) The item was placed on the consent agenda for deferral to the March 11, 2004 Planning Commission meeting. A motion was made to approve the consent agenda and was approved with a vote of 11 ayes, 0 noes and 0 absent. PLANNING COMMISSION ACTION: (March 11, 2004) The item was placed on the consent agenda for deferral to the April 22, 2004 Planning Commission meeting. A motion was made to approve the consent agenda and was approved with a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: A.2 FILE NO.: MSP03-04 Name: Master Street Plan Amendment - Chenal Planning District Location: Between Kirk Road and the Champlin/Wellington Hills Proposed Minor Arterial Request: Removal of a Proposed Collector Street Source: Joe White, White - Daters & Associates PROPOSAL / REQUEST: Master Street Plan amendment in the Chenal Planning District for the removal of a Proposed Collector Street and abandonment of the dedicated Right-of-Way running through the applicant’s property. Collector Streets are to provide access to and from the arterial network to a development, subdivision or large center of activity, as well as access to adjacent properties. The applicant wishes to remove the Proposed Collector Street to assemble land for office development. Staff has not expanded the application since the entire length of the segment consists of right-of-way running through the applicant’s property and does not extend beyond the two streets it connects. The length of the segment is about 1,390 + feet. CURRENT MASTER STREET PLAN: The Proposed Collector Street shown would connect Kirk Road to the Champlin / Wellington Hills Proposed Minor Arterial. Kirk Road is shown on the plan as a Collector Street and is built as a rural two-lane road. Kirk Road will need improvements in order to conform to the Master Street Plan standards for Collector Streets. The Champlin / Wellington Hills Proposed Minor Arterial shown on the plan is intended to link Champlin Drive to Wellington Hills Road and would need to be built. The Master Street Plan also shows an extension to Systems Drive as a Proposed Collector Street. FUTURE LAND USE PLAN: The intersection of the Proposed Collector Street with Kirk Road is shown as Commercial except for the northeast corner, which is shown as Office. The property where the Proposed Collector Street will intersect the March 11, 2004 SUBDIVISION ITEM NO.: A.2 (Cont.) FILE NO.: MSP03-04 2 Champlin/Wellington Hills Proposed Minor Arterial is shown as Multifamily on the west side of the intersection, while the east side is shown as Low Density Residential. All of the land along the segment in question east of Kirk Road is the subject of a Land Use Plan amendment and is a separate item on this agenda. HISTORIC DISTRICTS: There are no historic districts that would be affected by this amendment. CITY RECOGNIZED NEIGHBORHOOD ACTION PLAN: The property under review is not located in an area covered by a City of Little Rock recognized neighborhood action plan. ANALYSIS: Pastureland lies on both sides of the Proposed Collector Street. The proposed street segment that would link the office developments west of Kirk Road to the residential areas located north and east of Wellington Hills Road. The removal of the Proposed Collector Street would necessitate that the adjacent property be accessed by other means and could result in more curb cuts, on Kirk Road, Champlin / Wellington Hills, and the Systems Drive extension. The Proposed Collector Street has a dedicated Right-of-Way of 60 feet. The design standards for Proposed Collector Streets are intended to serve a traffic count of 5,000 vehicles per day. Removal of the Proposed Collector Street with the suggested future development pattern would likely increase traffic on Kirk Road and the Champlin / Wellington Hills connection. If approved, the Champlin / Wellington Hills Proposed Minor Arterial would serve the role of providing access to adjacent properties. Minor Arterials are intended to provide access between different sections of the city with the secondary purpose of providing access to adjacent properties. Although Kirk Road, as a Collector Street, is intended to link the neighborhood to an Arterial, this application would increase the traffic on Kirk Road by increasing its use for access to adjacent property. Since the Proposed Collector Street is a short segment that begins at Kirk Road and ends at the Proposed Minor Arterial, it is not as likely that it would become a cut-through street. The Proposed Collector Street would be more likely to be used to access adjacent property. The current street pattern shown on the Master Street Plan anticipated a higher density of land development. The three Proposed Collectors link properties to March 11, 2004 SUBDIVISION ITEM NO.: A.2 (Cont.) FILE NO.: MSP03-04 3 the Champlin / Wellington Hills Proposed Minor Arterial. If the related land use plan amendments are approved, the Future Land Use Plan would accommodate higher densities of development than is currently shown. Any increased density would generate a larger amount of traffic that would need the proposed streets shown on the Master Street Plan. The Proposed Collector Street in question, as well as the one that would extend Systems Drive, would complement each other to link the office developments to the west with residential areas located east of Champlin / Wellington Hills. If this amendment is approved the Proposed Collector Street located at the end of Systems Drive would serve a higher volume of traffic as the only link between the residential areas to the east and the non- residential areas to the west. Due to the high number of land use plan amendments in this area, there is a need for roads. This amendment bisects an area under consideration for a Land Use Plan amendment for a change from Multifamily to Office, which could increase the intensity of development and could increase the amount of traffic generated. The plan amendment could result in a larger area of intense development between Kirk Road and the Proposed Minor Arterial from Chenal Parkway and the Systems Drive extension. The Proposed Collector Street currently shown lies approximately halfway between Chenal Parkway and the systems drive extension. This Master Street Plan amendment coupled with increases of intensity of development proposed by the Land Use Plan amendment would create a an area of intense development that would only be accessed from streets located at the periphery. NEIGHBORHOOD COMMENTS: Notices were sent to the following neighborhood associations: Aberdeen Court Property Owners Association, Bayonne Place Property Owners Association, Carriage Creek Property Owners Association, Chenal Ridge Property, Du Quesne Place P.O.A., Eagle Pointe Property Owners Association, Glen Eagles Property Owners Association, Hillsborough Property Owners Association, Hunters Cove Property Owners Association, Hunters Green Property Owners Association, Johnson Ranch Neighborhood Association, Marlowe Manor Property Owners Association, Maywood Manor Neighborhood Association, St. Charles Property Owners Association, Charleston Heights/North Rahling Rd N.A., Margeaux Place Property Owners Association, and Parkway Place Property Owners Association. Staff has received one comment from area residents. The one comment received was neutral. March 11, 2004 SUBDIVISION ITEM NO.: A.2 (Cont.) FILE NO.: MSP03-04 4 STAFF RECOMMENDATIONS: Staff believes the change not appropriate based on the suggested land use pattern and information provided. PLANNING COMMISSION ACTION: (December 4, 2003) The item was placed on the consent agenda for deferral to the January 29, 2004 Planning Commission meeting. A motion was made to approve the consent agenda and was approved with a vote of 11 ayes, 0 noes, and 0 absent. PLANNING COMMISSION ACTION: (January 29, 2004) The item was placed on the consent agenda for deferral to the March 11, 2004 Planning Commission meeting. A motion was made to approve the consent agenda and was approved with a vote of 11 ayes, 0 noes and 0 absent. March 11, 2004 SUBDIVISION ITEM NO.: A.2 (Cont.) FILE NO.: MSP03-04 5 For copies of letters and emails concerning this item see Item A.1. PLANNING COMMISSION ACTION: (March 11, 2004) The item was placed on the consent agenda for deferral to the April 22, 2004 Planning Commission meeting. A motion was made to approve the consent agenda and was approved with a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 1 ITEM NO.: A.3 FILE NO.: Z-4807-E Owner: Shackleford Family Trust Applicant: White-Daters and Associates Location: Along the east side of Kirk Road, north of Chenal Parkway Area: Approximately 120 acres Request: Rezoning from Various Districts to MF-18, O-2, O-3 and C-3 Purpose: Future development Existing Use: Undeveloped SURROUNDING LAND USE AND ZONING North – Apartment complex and undeveloped property; zoned MF-18, O-3 and C-1 South – Auto dealership, branch bank, dental clinic; zoned PD-C and C-3 East – Undeveloped property and mini-warehouse development; zoned R-2, R-3, MF-6, MF-18 and POD West – Single family residential, auto repair garage, office uses and undeveloped property (across Kirk Road); zoned O-2, O-3 and C-3 A. PUBLIC WORKS COMMENTS: 1. Refer to all comments for the preliminary plat (Item 6.). Show all existing and proposed right-of-way dedications on the zoning plan. B. PUBLIC TRANSPORTATION ELEMENT: The site is not located on a CATA bus route. C. PUBLIC NOTIFICATION: All property owners located within 200 feet of the site, all residents within 300 feet who could be identified, and the St. Charles and Parkway Place Neighborhood Associations were notified of the public hearing. March 11, 2004 SUBDIVISION ITEM NO.: A.3 (Cont.) FILE NO.: Z-4807-E 2 D. LAND USE ELEMENT: This request is located in the Chenal Planning District. The Land Use Plan shows Office, Multifamily, Low Density Residential and Single Family for this property. The applicant has applied for O-2 Office and Institutional, O-3 General Office, C-3 General Commercial and MF-18 Multifamily for office, retail and multifamily development. A land use plan amendment for a change to Office, Commercial and Multifamily is a separate item on this agenda. City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the Rock Creek Neighborhood Action Plan. The Office and Commercial Development goal listed an action statement that recommends the aggressive use of Planned Zoning Districts to influence more neighborhood-friendly and better quality development. E. STAFF ANALYSIS: Shackleford Family Trust, owner of the 120 acres of property located along the east side of Kirk Road, north of Chenal Parkway, is requesting to rezone the majority of the property from various districts to MF-18, O-2, O-3 and C-3. The rezoning is proposed for the future development of the property. In addressing an overall development plan for the property, the applicant has also filed a land use plan amendment, master street plan amendment and preliminary plat. Those issues are also items on this Planning Commission agenda. The property is undeveloped and mostly grass-covered pasture land. Portions of the property are sparsely tree-covered. The property has varying degrees of slope. There are two (2) single family residences located within the west one-half of the property, which take access from Kirk Road. The general area contains a mixture of uses and zoning. There is an apartment complex and undeveloped MF-18, O-3 and C-1 zoned property to the north. There is an auto dealership, branch bank and dental clinic to the south, with a Kroger store development further south across Chenal Parkway. The Arkansas Systems Office Park is located across Kirk Road to the west, along with an auto repair business and three or four single March 11, 2004 SUBDIVISION ITEM NO.: A.3 (Cont.) FILE NO.: Z-4807-E 3 family residences. The majority of the property to the east is undeveloped and zoned R-2, R-3, MF-6 and MF-18. There is a mini-warehouse development at the southeast corner of the property, with the Villages of Wellington single family development being located further to the east. The applicant is proposing to rezone the majority of the property from various districts to MF-18, O-2, O-3 and C-3. The list of the proposed rezoning is as follows, with the “Area” numbers referring to the attached sketch map, and the acreage calculations being approximations. The acreage calculations do not include the proposed street rights-of-way. Area 1. Rezone from R-2 to MF-18 (5.5 Acres) Area 2. Rezone from R-3 to MF-18 (17.5 Acres) Area 3. Rezone from MF-6 to MF-18 (19 Acres) Area 4. Rezone from O-2 to MF-18 (4.5 Acres) Area 5. Rezone from MF-18 to O-2 (8.3 Acres) Area 6. Rezone from O-2 to O-3 (5 Acres) Area 7. Rezone from O-2 to C-3 (4.3 Acres) Area 8. Rezone from O-2 to MF-18 (4.3 Acres) Area 9. Rezone from R-2 to MF-18 (6 Acres) Area 10. Remain zoned MF-18 (19 Acres) Area 11. Remain zoned O-2 (13.3 Acres) The City’s Future Land Use Plan designates this property as Office, Multifamily, Low Density Residential and Single Family. The applicant has filed a land use plan amendment for a change to Office, Commercial and Multifamily. This issue is a separate item on this agenda (Item 6.1). Although staff is supportive of an overall development plan for this 120 acres, staff does not support all of the zoning changes as proposed. Staff supports the rezoning of Areas 5, 8 and 9 as described above, with Areas 10 and 11 remaining zoned MF-18 and O-2 respectively. Staff does not support the rezoning of Areas 1-4, 6 and 7 as requested. Staff feels that Areas 1-4 should be zoned to MF-12 (instead of MF-18), a lower multifamily density, with a 50 foot wide zoned OS (Open Space) strip along the east property line. Staff feels that this will provide a good transition from the minor arterial to the single family zoning to the east, and provide an adequate buffer between a multifamily development and the future expansion of the Villages of Wellington single family development. Staff also feels that Area 6 should remain zoned O-2 March 11, 2004 SUBDIVISION ITEM NO.: A.3 (Cont.) FILE NO.: Z-4807-E 4 (instead of O-3) and maintained as part of the overall O-2 tract to the east. Staff does not feel that small O-3 zoned tracts will be appropriate for this area along the east side of Kirk Road (see Item 6. – proposed preliminary plat). Additionally, staff feels that it would be more appropriate to zone Area 7 to C-1 Neighborhood Commercial District (instead of C-3), as it is adjacent to proposed multifamily zoning to the north and east. According to Section 36-299 of the City’s Zoning Ordinance, “The C-1 Neighborhood Commercial District is designed to accommodate limited retail developments within or adjacent to neighborhood areas for the purpose of supplying daily household needs of the residents food, drugs and personal services.” Staff feels that C-1 zoning would be more compatible with the overall zoning plan for the property, given the total amount of multifamily zoning proposed. Staff feels that the overall zoning plan for the property, as suggested by staff, will have no adverse impact on the adjacent property or the general area. Staff feels that the 46.5± acres of proposed MF-18 zoning on the east side of the future minor arterial is too much multifamily density of the area, given the 29 acres of MF-18 zoning proposed for the west side of the arterial along with the existing multifamily zoning and development to the north and southeast. In addition, staff believers a 50 foot wide zoned OS buffer along the east property line, north of the future minor arterial, will provide an adequate buffer between a future MF-12 development and future expansion of the single family development to the east. F. STAFF RECOMMENDATION: Staff recommends denial of the rezoning plan, as requested. PLANNING COMMISSION ACTION: (DECEMBER 4, 2003) Mr. Joe White was present representing the request. There were several registered objectors present. Staff stated the applicant had requested this item be deferred to the December 18, 2003 Public Hearing. Staff stated they would recommend the application be deferred to the January 29, 2004 Public Hearing March 11, 2004 SUBDIVISION ITEM NO.: A.3 (Cont.) FILE NO.: Z-4807-E 5 to allow all the related item to be considered at the same time. The applicant indicated they were agreeable to this recommendation. There was no further discussion of the item. The item was placed on the consent agenda for deferral. The motion carried by a vote of 11 ayes, 0 noes and 0 absent. PLANNING COMMISSION ACTION: (JANUARY 29, 2004) Mr. Joe White was present representing the request. There were no registered objectors present. Staff stated the applicant submitted a letter requesting the item be deferred to the March 11, 2004 Public Hearing. Staff stated they were supportive of the request. There was no further discussion of the item. The item was placed on the consent agenda for deferral. The motion carried by a vote of 11 ayes, 0 noes and 0 absent. PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Joe White was present representing the request. There were registered objectors present. Staff stated the applicant had submitted a letter dated March 1, 2004 requesting the item be deferred to the April 22, 2004 Planning Commission Public Hearing. Staff stated the deferral request would require a waiver of the By-Laws related to the number of allowed deferrals. Staff stated the applicant had notified property owners as required by the Planning Commission By-Laws of the deferral request. Staff stated they were supportive of the By-Law waiver and the deferral request. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: B FILE NO.: LU03-18-03 Name: Land Use Plan Amendment - Ellis Mountain Planning District Location: 15500 Chenal Parkway Request: Suburban Office to Commercial Source: Joe White, White-Daters & Associates PROPOSAL / REQUEST: Land Use Plan amendment in the Ellis Mountain Planning District from Suburban Office to Commercial. The Commercial category includes a broad range of retail and wholesale sales of products, personal and professional services, and general business activities. Commercial activities vary in type and scale, depending on the trade area that they serve. The applicant wishes to build an automobile dealership. Staff is not expanding the application since a land use review is a part of a Neighborhood Action Plan currently being updated. EXISTING LAND USE AND ZONING: The property is mostly vacant land with a few small buildings located on the curve of Kanis Road currently zoned O-2 Office and Institutional and is about 13.5 acres ± in size. The land in the median of Chenal Parkway is zoned PR - Parks and Recreation while the north side of Chenal Parkway is vacant land zoned C-3 General Commercial. The houses in the subdivision east of the applicant’s property are zoned R-2 Single Family. A strip of vacant land along the north side of Kanis Road is zoned O-2. The south side of Kanis Road consists of vacant land zoned O-2. The neighboring land to the west consists of a business zoned R-2 on the north side of Kanis Road and a house built on a large lot south of Kanis Road. FUTURE LAND USE PLAN AND RECENT AMENDMENTS: On June 17, 2003, multiple changes were made from Office, Single Family, and Multifamily to Multifamily and Low Density Residential for an area north of Chenal Parkway and south of Rahling Road about 1/3 of a mile northwest of the study area to accommodate proposed development and recognize existing conditions. March 11, 2004 SUBDIVISION ITEM NO.: B (Cont.) FILE NO.: LU03-18-03 2 On April 17, 2001 a change was made from Single Family, Multifamily, and Park / Open Space to Community Shopping at Rahling Road and Chenal Parkway starting over ¾ of a mile to the west of the application area to accommodate proposed development. On January 4, 2000 a change was made form Office to Mixed Office Commercial at 15500 Chenal Parkway across the street north of the applicant’ property to accommodate proposed development. On April 20, 1999 a change was made from Office to Mixed Office Commercial on Chenal Parkway east of Kirk Road about ¼ of a mile west of the application area to accommodate proposed development. On March 2, 1999 multiple changes were made from Low Density Residential, Transition, and Neighborhood Commercial to Single Family, Low Density Residential, Single Family, Suburban Office, and Mixed Office Commercial along Kanis Road within one mile east of the property in question to recognize existing conditions. The applicant’s property is shown as Suburban Office on the Future Land Use Plan. The median of Chenal Parkway is shown as Park / Open Space while the land to the north is shown as Commercial. The land to the east is shown as Single Family with a small strip of Suburban Office shown on the north side of Kanis Road. The south side of Kanis Road is shown as Suburban Office. To the west, a strip of Park / Open Space is shown along the floodway of Rock Creek while Commercial is shown further to the west at the intersection of Kanis Road with Chenal Parkway. MASTER STREET PLAN: Chenal Parkway is shown as a Principal Arterial built with a four-lane Parkway cross section as required by ordinance. Kanis Road is shown as a Minor Arterial and is built as a rural two-lane road. Kanis Road needs improvement in order to conform to the Master Street Plan standards for Minor Arterials. A Class I bikeway is shown for Chenal Parkway from Bowman Road to State Highway 10. PARKS: The Little Rock Parks and Recreation Master Plan of 2001 show a Potential Greenbelt along Rock Creek in the median of Chenal Parkway. The plan is to develop the median of Chenal Parkway as a linear park and will include the construction of the Class I bikeway shown on the Master Street Plan. March 11, 2004 SUBDIVISION ITEM NO.: B (Cont.) FILE NO.: LU03-18-03 3 HISTORIC DISTRICTS: There are no historic districts that would be affected by this amendment. City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the Rock Creek Neighborhood Action Plan. The Office and Commercial Development goal listed an action statement that recommends the aggressive use of Planned Zoning Districts to influence more neighborhood-friendly and better quality development. ANALYSIS: This amendment would increase the area shown for Commercial uses along Chenal Parkway at the expense of areas available for office developments. A change to Commercial at this location is a further break with the original Rock Creek Parkway (now Chenal) plan, which recommended office and multifamily use along this portion of Chenal Parkway (formerly Rock Creek Parkway). The original land use pattern for the area placed low intensity land use patterns along Chenal Parkway (formerly Rock Creek Parkway) and the more intense land uses away from Rock Creek. This change would further intensify land development along the Rock Creek portion of Chenal Parkway. The primary purpose of the areas shown as Park / Open Space in the vicinity of the applicant’s property is to protect the integrity of Rock Creek. The strip of PK/OS shown along the banks of Rock Creek provides a buffer between the more intense uses west of Rock Creek from the less intense uses to the east. Development of the applicant’s property would need to be done in a manner that would minimize any run-off towards Rock Creek with the goal of preserving the ecological and hydrological integrity of the Rock Creek. This change would introduce a use in an area that is incompatible with neighboring uses. Any non-residential development of this site needs to be compatible with the adjacent residential properties. If this amendment were approved, the Planned Zoning Development process governing the development of the applicant’s property should be required. If a proposed development has design characteristics that are incompatible with residential properties, potential negative impacts from non-residential development could be minimized if the PZD process governed future proposals. The current Suburban Office category would allow non-residential development to take place at this location under the PZD process. The development of the property should be minimized in size dimensions and avoid the mass and bulk typical of commercial developments March 11, 2004 SUBDIVISION ITEM NO.: B (Cont.) FILE NO.: LU03-18-03 4 that are incompatible with neighboring residential uses. The development of the property with Suburban Office uses with a PZD increases the likelihood that the negative impacts of size, mass and bulk of development would be minimized. Any development of the applicant’s property would require access that may affect the flow of traffic on Chenal and Kanis, and would need to be designed in a manner, which would minimize any potential disruptions. The applicant’s property is situated to benefit from double frontage along two arterials. Chenal Parkway is intended to have a daily traffic count of 25,000 vehicles per day, while Kanis road is intended to have a daily traffic count of 18,000 vehicles per day. Principal Arterials are intended to serve through traffic on a regional level, while Minor Arterials are intended to serve through traffic at a more local level. The proposed change, along with vacant areas shown as Commercial, and the possibility of commercial development in vacant areas shown as Mixed Office Commercial could result in a corridor of commercial development along Chenal Parkway from the intersection of Wellington Hills Road to the western intersection of Kanis Road west of Kirk Road. The removal of Suburban Office could reduce the area of land available for the development of small-scale offices and increase the intensity of office development in areas, which would remain for quite office uses. NEIGHBORHOOD COMMENTS: Notices were sent to the following neighborhood associations: Gibraltar/Pt. West/Timber Ridge, Parkway Place Property Owners Association, Spring Valley Manor Property Owners Association, Carriage Creek Property Owners Association, St. Charles Property Owners Association, SW Little Rock UP, and WCLR Coalition of Neighborhoods. Staff has received one comment from area residents. The comment received was opposed to the change. STAFF RECOMMENDATIONS: Staff believes the change is not appropriate. This change is incompatible with the uses to the east. March 11, 2004 SUBDIVISION ITEM NO.: B (Cont.) FILE NO.: LU03-18-03 5 PLANNING COMMISSION ACTION: (December 4, 2003) The item was placed on the consent agenda for deferral to the January 29, 2004 Planning Commission meeting. A motion was made to approve the consent agenda and was approved with a vote of 10 ayes, 0 noes, 0 absent, and 1 recuse. PLANNING COMMISSION ACTION: (January 29, 2004) The item was placed on the consent agenda for deferral to the March 11, 2004 Planning Commission meeting. A motion was made to approve the consent agenda and was approved with a vote of 11 ayes, 0 noes and 0 absent. PLANNING COMMISSION ACTION: (March 11, 2004) The applicant chose to defer this item for two weeks when offered because there were only eight voting members present. A motion was made to defer the item until March 25, 2004. The motion was approved with a vote of 8 ayes, 0 noes, 2 absent and 1 recusal. March 11, 2004 ITEM NO.: B.1 FILE NO.: Z-4841-B NAME: Pinnacle Ford Long-form PCD LOCATION: South of Chenal Parkway, east of the Kanis Road intersection DEVELOPER: Pinnacle Ford 11200 West Markham Street Little Rock, AR 72211 ENGINEER: White-Daters and Associates #24 Rahling Circle Little Rock, AR 72223 AREA: 13.5 Acres NUMBER OF LOTS: 2 FT. NEW STREET: 0 CURRENT ZONING: O-2 ALLOWED USES: Office and Institutional District PROPOSED ZONING: PCD and O-2 PROPOSED USE: Automobile dealership for Lot 1 and Lot 2 remaining undeveloped at this time and zoned O-2 VARIANCES/WAIVERS REQUESTED: None requested. BACKGROUND: In June 1987, two rezoning application, Z-4840 and Z-4841 were filed for a portion of the land under consideration. The initial request involved 12.1 acres and a second added five acres for a total of 17 acres. One request was for an O-3 reclassification, March 11, 2004 SUBDIVISION ITEM NO.: B.1 (Cont.) FILE NO.: Z-4841-B 2 and the other one requested a change to O-3 and C-3. Z-4840 was withdrawn without prejudice, and Z-4841, the O-3 proposal was denied by the Planning Commission. Ordinance No. 15,552 adopted by the Little Rock Board of Directors on September 6, 1988, reclassified the property from R-2, Single-family to O-2, Office and Institutional District. The adopted ordinance also placed restrictions on the development of the tract. The site was to have a 33-foot landscaped or undisturbed buffer along the Rock Creek Parkway; a 35-foot height limit for buildings; one access point on the Rock Creek Parkway; and a 40-foot minimum building setback from the property line on the Rock Creek Parkway side. The developer indicated the development would be constructed as an “attractive office park”. A. PROPOSAL/REQUEST: The applicant is requesting to rezone the site from O-2, Office and Institutional District to Planned Commercial Development (PCD) to allow the site to develop with two (2) lots, one containing an automobile dealership and the second lot remaining zoned O-2. Lot 1 will contain 11.49 acres and Lot 2 will contain 2.0 acres. Pinnacle Ford is requesting to develop Lot 1 for their new car and used car operations. At present there are no development plans for Lot 2, which would be developed and final platted at a later date. The applicant is requesting a two year deferral of street improvements to Kanis Road for Lot 1. The applicant has indicated street improvements to Kanis Road for Lot 2 will be constructed with the final platting of the lot. The applicant has indicated two structures will be constructed on Lot 1. One will house the new car showroom and service areas and contains up to 31,400 square feet. The building also contains “hospitality zones” such as children’s play area, customer work area with phone access, laptop stations, desktops etc., and a café for customers while waiting (not food service). The other building is for pre-owned vehicle sales and clean-up and contains approximately 3,600 square feet. Other development considerations included by the applicant are all exterior lighting will be focused inward to minimize or eliminate ambient light into adjacent neighborhoods, there will be no outside paging allowed at the dealership and there will be no off-loading of vehicles in the public right-of-way. The applicant has indicated a 100-foot buffer along the east side of proposed Lot 1 with the area to be set aside as an undisturbed buffer adjacent to the residential property. There are no development plans for Lot 2 which is proposed to remain zoned O-2, Office and Institutional District. March 11, 2004 SUBDIVISION ITEM NO.: B.1 (Cont.) FILE NO.: Z-4841-B 3 B. EXISTING CONDITIONS: The western portion of the site is vacant and cleared with trees remaining on the site along the eastern perimeter. The site is relatively flat with roadway access to both Chenal Parkway and Kanis Road. Chenal Parkway in this area is a divided roadway with the two eastbound lanes adjacent to the site. Kanis Road is an unimproved narrow road with open ditches for drainage. To the east of the site is a fully developed single-family neighborhood, Wood Creek. To the north of the site is the divided parkway with C-2 zoned property located to the north. The area to the south of the site is vacant O-2 zoned property abutting Pride Valley Road extending to the west. A PCD is located southwest of the site which is currently an agriculture nursery. West of the site is Rock Creek with Kinco Construction Company buildings located on the western bank of the creek. Other uses in the area include a PD-C approved (construction has not taken place) for Parker Saturn automobile dealership located on the corner of Wellington Hills Road and Chenal Parkway, a church, a PCD for a home improvement store and a vacant C-3 zoned tract. The Kroger shopping center, also zoned PCD, is located on the southwest corner of Chenal Parkway and the current Kanis Road intersection. The Master Street Plan indicates Kanis Road turning north along the western boundary of the Kinco property to align with Wellington Hills Road. Kanis Road adjacent to this site is classified on the Master Street Plan as a minor arterial street. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has received several phone calls and letters of opposition to the proposed development. The Parkway Place Property Owners Association, the Gibralter Heights/Point West/Timber Ridge Neighborhood Association, all residents located within 300-feet of the site who could be identified and all property owners located within 200-feet of the site were notified of the public hearing. In addition a neighborhood meeting was held November 11, 2003 at the Parkway Place Baptist Church. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. The proposed right-of-way dedication on Kanis Road meets the minor arterial standard. March 11, 2004 SUBDIVISION ITEM NO.: B.1 (Cont.) FILE NO.: Z-4841-B 4 2. Provide design of street conforming to the Master Street Plan. Construct one- half street improvement to the street including 5-foot sidewalk with the planned development. Traffic Engineering comments are as follows: - Driveway needs to be designed according to Chenal Master Plan Standards - Driveway taper needs to be 150-feet 3. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities. Submit cross sections demonstrating compliance with the terracing provisions of the land alteration ordinance. Site grading and drainage plans will need to be submitted and approved prior to the start of construction. 4. Storm water detention ordinance applies to this property. Show the proposed location of storm water detention facilities on the plan. 5. A special Grading Permit for Flood Hazard Areas will be required per Section 8-283 prior to construction. 6. Hauling of fill material on or off the site over municipal streets and roads requires approval prior to a grading permit being issued. Contact Public Works Traffic Engineering at 621 S. Broadway, (501) 379-1817 (Derrick Bergfield) for more information. 7. The eastern-most driveway location does not meet the traffic access and circulation requirements of Sections 30-43 and 31-210. The drive can be moved west to 150-feet from proposed Lot 2 or can share a single driveway with Lot 2. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer main extension required, with easements, if service is required for the project. Contact the Little Rock Wastewater Utility at 688-1414 for additional details. Entergy: A 20-foot easement behind the new right-of-way line for relocation of existing 3Ø overhead power line. Contact Entergy at 954-5158 for additional details. Center-Point Energy: Approved as submitted. SBC: No comment received. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. A Capital Investment Charge based on the size of connection(s) will apply to this project in addition to normal charges. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. This development will have minor impact on the March 11, 2004 SUBDIVISION ITEM NO.: B.1 (Cont.) FILE NO.: Z-4841-B 5 existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact Central Arkansas Water at 992-2438 for additional details. Fire Department: Approved as submitted. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: This request is located in the Ellis Mountain Planning District. The Land Use Plan shows Suburban Office for this property. The applicant has applied for a Planned Commercial Development for a car dealership. A land use plan amendment for a change to Commercial is a separate item on this agenda (Item #13 – File No. LU03-18-03). Landscape: The proposed western land use buffer is less than the fifty (50) foot average width requirement of the zoning ordinance. A six (6) foot high opaque screen, either a wooden fence with its face side directed outward, a wall, or dense evergreen plantings, is required along the eastern and western perimeters. Credit toward fulfilling this requirement can be given for existing trees and vegetation that satisfies this year-around requirement. An irrigation system to water landscaped areas will be required. Prior to obtaining a building permit, it will be necessary to provide approved landscape plans stamped with the seal of a Registered Landscape Architect. The City Beautiful Commission recommends preserving as many trees as feasible on this site. Extra credit toward fulfilling landscape ordinance requirements can be given when properly preserving trees of six (6) inch caliper or larger. City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the Rock Creek Neighborhood Action Plan. The Office and Commercial Development goal listed an action statement that recommends the aggressive use of Planned Zoning Districts to influence more neighborhood- friendly and better quality development. March 11, 2004 SUBDIVISION ITEM NO.: B.1 (Cont.) FILE NO.: Z-4841-B 6 G. SUBDIVISION COMMITTEE COMMENT: (November 6, 2003) Mr. Tim Daters and Mr. Gary Dean were present representing the request. Staff presented an overview of the development indicating the site would require an amendment to the City’s Future Land Use Plan. Staff noted there were additional items needed to complete the review of the proposed development. Staff questioned the applicant’s intent with regard to the median. The applicant indicated they would not request the median be cleared as a part of the Master Parks Plan. Staff questioned placement of any proposed dumpsters, where the delivery of automobiles would be taken, the location of the service shop, the hours deliveries would be taken and if there would be an on-site auto body repair shop. Public Works comments were addressed. Staff noted special grading permits would be required prior to development. Staff also noted the storm water detention ordinance applied to the property. Staff requested the applicant relocate the driveway along Kanis Road to the west to 150-feet or to share a drive with proposed Lot 2. Landscaping comments were addressed. Staff noted the western land use buffer was less than the fifty foot average width required per the zoning ordinance. Staff also noted a six foot high opaque screen would be required along the eastern and western perimeters. Mr. Dean questioned if the 100-foot buffer would suffice for the required screening. Staff stated if the buffer remained evergreen, then the area would meet the requirement, otherwise the applicant would be required to plant shrubs in this area to provide the year around screening. Mr. Dean commented the property located to the west was zoned residentially but was not being used as a residential use. Staff noted the Planning Commission could deem the required screening unnecessary. Staff noted the required screening to the west was a fifty foot average. Staff also noted screening would be required adjacent to proposed Lot 2. There being no further items for discussion, the Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plan to staff addressing a few of the issues raised at the November 6, 2003 Subdivision Committee meeting. The applicant has indicated the location of the proposed dumpster and the required screening. The proposed dumpster is to be located adjacent to the proposed 100-foot March 11, 2004 SUBDIVISION ITEM NO.: B.1 (Cont.) FILE NO.: Z-4841-B 7 undisturbed buffer. The applicant has indicated screening will be placed on three sides as required by the zoning ordinance at least two feet above the top of the container. The applicant has indicated there will not be a body shop at this site. The applicant has indicated the parts and service hours of operation from 7:00 am to 6:00 pm Monday through Friday and from 8:00 am to 4:00 pm Saturday. The sales hours of operation are proposed from 8:00 am to 8:00 pm Monday through Friday and from 9:00 am to 7:00 pm Saturday and Sunday. The applicant has indicated 125 customer and employee parking spaces, 56 service parking spaces and 419 display spaces. One hundred of the employee and customer parking spaces are around the new car showroom, which is adjacent to the proposed 100-foot buffer. This area has separate gates for security to be closed during non-business hours. The applicant has also indicated a gates at all entrances to limit activity on the site when the business is not open. The gates are proposed as steel gates located across each drive of Kanis Road and Chenal Parkway. The applicant has not relocated the driveway along Kanis Road. The applicant has indicated with the drive at the shown location there is a “straight shot” to the service shop for customer traffic and for delivery of automobiles. The driveway does not meet the minimum requirement for driveway spacing per city ordinances. In addition, the proposed street construction along Chenal Parkway does not meet the Chenal Parkway street design criteria established through Ordinance Numbers 16,622 and 16,652. The applicant has indicated signage on Chenal Parkway and Kanis Road. The proposed signage will comply with the Chenal Parkway Design Overlay District requirement for a monument style sign not to exceed eight feet in height and one hundred square feet in area. There is also a ground mounted monument sign proposed for Kanis Road. The applicant has indicated this sign will also comply with the Chenal Overlay requirements. The site plan includes a tract of O-2 zoned property. Through the PCD the applicant is requesting the subdivision of this tract but is requesting the parcel remain zoned O-2. The proposed lot meets the minimum requirement for the O-2 zoning classification. The applicant is proposing the placement of 11.23 percent of the site including a 1.29 acre buffer along the eastern perimeter of the site as interior landscaping. The applicant has indicated the screening will be zoned OS too ensure the vitality of the area. The applicant has also indicated should the 100-foot buffer not provide year around screening additional plantings will be installed. March 11, 2004 SUBDIVISION ITEM NO.: B.1 (Cont.) FILE NO.: Z-4841-B 8 Staff is not supportive of the proposed request. Staff feels the proposed use is too intense for the site. The site adjoins a single-family neighborhood to the east and an elementary school is located in close proximity to the southeast. Currently the infrastructure is not in place to allow customers traveling west bound to access the site. The applicant has indicated customers will access the site from Kanis Road, which staff questions. Staff also has concerns with the delivery of automobiles, both the logistics of how the automobiles will be delivered and the hours the automobiles will be delivered. The applicant has not indicated the proposed delivery hours. Staff also has concerns with the location where deliveries will be taken. Currently staff has problems with automobile dealers in the general area taking deliveries in the right-of-way. The site is adjacent to two principal arterials and delivery in the right-of-way would be extremely dangerous. Kanis Road is a two lane roadway with open ditches for drainage, Chenal Parkway is a four lane road with a median but is well traveled. Staff feels allowing the use to locate on the site will invite cut-through traffic through the existing Wood Creek Subdivision. Staff has concerns of the noise from the site. The applicant has indicated there will be no outdoor paging as a part of the development but there are other noises that the site will generate. The applicant has indicated a repair shop to be located on the site. The shop will potentially hold twenty-eight cars waiting for service and the applicant has indicated an area for express service with a potential for eight cars. Staff feels this would generate a large amount of noise from impact wrenches and traffic moving around the site. The applicant has requested a two year deferral of the required street improvements to Kanis Road. Staff is not supportive of this request. If the site is developed with a heavy commercial use (a C-4 commercial use) staff feels the street improvements should be put in place at the time of development. The applicant has indicated Kanis Road will be used to access the site for service and for the off-loading of inventory. As stated, staff is not supportive of the proposed request. Staff feels the rezoning of this site to a commercial classification will encourage additional commercial development in the area. The Parkway has commercial uses at each end and along the divided median the area is predominately residential. Staff feels this should remain the case with the office zoning providing a transition between the single-family homes to the east and the non-conforming commercial use located across Rock Creek. I. STAFF RECOMMENDATION: Staff recommends denial of the proposed request. March 11, 2004 SUBDIVISION ITEM NO.: B.1 (Cont.) FILE NO.: Z-4841-B 9 PLANNING COMMISSION ACTION: (DECEMBER 4, 2003) Mr. Joe White was present representing the request. There were several registered objectors present. Staff stated the applicant had requested this item be deferred to the January 29, 2004 Public Hearing. Staff stated they were supportive of the request. There was no further discussion of the item. The item was placed on the consent agenda for deferral. The motion carried by a vote of 11 ayes, 0 noes and 0 absent. PLANNING COMMISSION ACTION: (JANUARY 29, 2004) Mr. Joe White was present representing the request. There were no registered objectors present. Staff stated the applicant submitted a letter requesting the item be deferred to the March 11, 2004 Public Hearing. Staff stated they were supportive of the request. There was no further discussion of the item. The item was placed on the consent agenda for deferral. The motion carried by a vote of 10 ayes, 0 noes, 0 absent and 1 Recuse (Commissioner Pam Adcock). PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Joe White was present representing the request. There were numerous registered objectors present. The Chair stated the Commission’s past policy had been to allow an applicant to defer an item when eight or fewer Commissioners were present. The Chair noted with Commissioner Adcock recusing from the discussion there were only eight Commissioners present. Mr. Joe White stated on behalf of the applicant, he would like to request a deferral to the March 25, 2004 Public Hearing. There was no further discussion of the item. A motion was made and approved to defer the item to the March 25, 2004 Public Hearing by a vote of 8 ayes, 0 noes, 2 absent and 1 recuse (Commissioner Pam Adcock). March 11, 2004 ITEM NO.: C FILE NO.: S-993-K NAME: Mabelvale Business Park and Shopping Center Revised Preliminary Plat LOCATION: on the south side of the I-30 Frontage Road at Mabelvale Pike DEVELOPER: Ashley Development Company 2851 Lakewood Drive Little Rock, AR 72116 ENGINEER: White-Daters and Associates #24 Rahling Circle Little Rock, AR 72223 AREA: 13.53 acres NUMBER OF LOTS: 2 FT. NEW STREET: 0 CURRENT ZONING: C-3, General Commercial District PLANNING DISTRICT: 15 – Geyer Springs West CENSUS TRACT: 41.05 VARIANCES/WAIVERS REQUESTED: None requested. BACKGROUND: On November 16, 1993, the Planning Commission approved a one lot commercial (lease lot arrangement) subdivision for a 61.6-acre property. Internal roadways were approved as a private street system. On August 7, 1997, the Planning Commission approved a preliminary plat to convert the single tract lease lot arrangement to a conventional commercial plat. The approved plat included seven (7) lots and three (3) large tracts, set aside for future platting. The private street system was also approved as part of the preliminary plat. On March 30, 2000, the Planning Commission approved a revision to the previously approved preliminary plat by splitting a lot into two (2) lots and proposed a lot design for the three large tracts. A total of 21 lots were proposed for the subdivision. The lots March 11, 2004 SUBDIVISION ITEM NO.: C (Cont.) FILE NO.: S-993-K 2 were to be final platted based on market demand. The Planning Commission approved several of the lots as double frontage lots. (where lots abut a private street the Commission may approve this configuration). To date, Lots 1, 2A, 2B, 2C, 3, 4, 5, 6, 14 and 16 along with the roadway have been final platted and developed. A Conditional Use Permit was reviewed and approved by the Planning Commission for Lot 14 at their March 3, 2003 Public Hearing. The applicant indicated a fifty-foot buffer along the west property line. A. PROPOSAL/REQUEST: The applicant is requesting a revised preliminary plat for the Mabelvale Business Center Addition. Lot 14 was indicated on the previously approved preliminary plat and has been final platted. The lot contains the a Home Depot store. The site is zoned C-3 and takes access from a sixty-foot private access and utility easement, Mabelvale Plaza Lane. The area indicated as Lot 20 is also zoned C-3 and fronts Mabelvale Pike. The request is to include additional area to the plat (Lot 20) and to adjust the lot line of Lot 14. The applicant has indicated by reducing the size of Lot 14 by approximately 16,000 square feet allows Lot 20 to become a more desirable lot by increasing the overall depth of the lot. The applicant has indicated one-half street improvements to Mabelvale Pike will be completed to arterial standards. The applicant has also indicated sidewalks will be installed at the time of building construction. B. EXISTING CONDITIONS: The site contains the Home Depot store and proposed Lot 20 contains single- family structures. The area to the north and east are vacant both zoned C-3, General Commercial District. Other uses in the area include a strip retail center, Wal-Mart and several restaurants. There are office uses fronting the I-30 Frontage Road. Along Mabelvale Pike there are residential uses both in single- family and duplex housing. C. NEIGHBORHOOD COMMENTS: As of this writing staff has not received any comment from area residents. Southwest Little Rock United for Progress, the West Baseline Neighborhood Association, the Pinedale Neighborhood Association, the Mavis Circle Neighborhood Association and all abutting property owners were notified of the public hearing. March 11, 2004 SUBDIVISION ITEM NO.: C (Cont.) FILE NO.: S-993-K 3 D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. With final platting or the building permit, Mabelvale Pike must be constructed to Master Street Plan standards. Improvements should match to turn lane into Mabelvale Plaza Lane. 2. The proposed drive location appears too close to the curve to provide safe sight distance. Drive location should be moved south, obtain approval from Traffic Engineering. 3. Prepare a letter of pending development addressing streetlights as required by Section 31-403 of the Little Rock code. Contact Traffic Engineering (501) 379-1813 (Steve Philpot) fro more information regarding street light requirements. 4. A grading permit in accordance with Section 29-186(c) and (d) will be required prior to any land clearing or grading activities at the site. Site grading, and drainage plans will need to be submitted and approved prior to start of construction. 5. Plans of all work in the right-of-way shall be submitted for approval prior to start of work. Obtain barricade permit prior to doing any work in the right-of- way from Traffic Engineering at (501) 379-1817 (Derrick Bergfield). 6. Obtain permits for improvements within State Highway right-of-way from AHTD, District VI. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Contact Little Rock Wastewater Utility at 688-1414 for additional details. Entergy: Approved as submitted. Center-Point Energy: Approved as submitted. SBC: Approved as submitted. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. The private waterline serving Home Depot must be entirely on Lot 14 and must be relocated if this replat causes it to be off of the parcel which it serves. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact CAW at 992-2438 for additional details. Fire Department: Approved as submitted. March 11, 2004 SUBDIVISION ITEM NO.: C (Cont.) FILE NO.: S-993-K 4 County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: A 9-foot wide landscape strip will be required along each side of the proposed new perimeter lot lines. G. SUBDIVISION COMMITTEE COMMENT: (January 8, 2004) Mr. Tim Daters was present representing the request. Staff presented the request indicating there were additional items that should be included on the proposed preliminary plat. Staff questioned if Home Depot was the current owner of Lot 14. Mr. Daters stated the transfer of the property from the Ashley Group to Home Depot had taken place. Staff requested Home Depot be included in the certificate of owners. Staff also commented the Conditional Use Permit for the Home Depot would require a revision to allow the plat to be configured in the proposed manner. Staff stated the previous approval included a 50-foot buffer and the current buffer was reduced to approximately 10-feet. Mr. Daters stated he would contact the owners and follow up with the revision to the Conditional Use Permit. Public Works comments were briefly discussed. Staff stated construction of Mabelvale Pike would be required to Master Street Plan standard. Staff stated deferral of the sidewalk construction was a desirable alternative. Landscaping comments were noted. There, being no further items for discussion, the Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plat to staff addressing the issues raised at the January 8, 2004 Subdivision Committee Meeting. The applicant has indicated a ten foot minimum buffer between the Home Depot parking lot and the new lot line. The applicant has also submitted a revision to the Home Depot Conditional Use Permit (Item No. 20 – File No. Z-3459-H) reducing the western buffer area to match the proposed lot line. The applicant has indicated a jog in the proposed lot line near the intersection with Mabelvale Plaza Drive, which allows the Home Depot sign to remain on their ownership. The applicant has indicated Home March 11, 2004 SUBDIVISION ITEM NO.: C (Cont.) FILE NO.: S-993-K 5 Depot on the proposed plat along with the source of title for Home Depot. The applicant has indicated one-half street improvements will be installed on Mabelvale Pike at the time of final platting. The applicant is however requesting a deferral of sidewalk improvements until building permit. Staff is supportive of this request. Otherwise, to staff’s knowledge, there are no outstanding issues associated with the proposed request. The development of the additional lot and the reconfiguration of the existing lot should have minimal to no adverse impact on the adjoining properties. I. STAFF RECOMMENDATION: Staff recommends approval of the request as filed subject to compliance with the conditions outlined in paragraphs D, E and F of the above staff report. Staff recommends approval of the requested deferral of sidewalk placement along Mabelvale Pike until building permit. PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Joe White was present representing the request. There were no registered objectors present. Staff presented the item requesting a deferred to the March 25, 2004 Planning Commission Public Hearing. Staff stated the item was related to a conditional use permit filed for the current agenda and since there were issues related to the conditional use permit staff was requesting the deferral to allow the items to be discussed simultaneously. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: D FILE NO.: S-1413 NAME: The Plaza Subdivision Preliminary Plat LOCATION: On the northwest corner of Colonel Glenn Road and I-430 DEVELOPER: Boen Enterprises LLC 10600 Colonel Glenn Road Little Rock, AR 72204 ENGINEER: McGetrick and McGetrick Engineers 319 President Clinton Avenue Little Rock, AR 72201 AREA: 5.509 acres NUMBER OF LOTS: 3 FT. NEW STREET: 0 CURRENT ZONING: C-2, Shopping Center District PLANNING DISTRICT: 12 – 65th Street West CENSUS TRACT: 24.05 VARIANCES/WAIVERS REQUESTED: None requested. A. PROPOSAL/REQUEST: The proposed development consists of 87.137 acres currently zoned C-2, Shopping Center District. The applicant intends to subdivide this site into four (4) lots to be marketed for C-2 commercial uses. The minimum lot proposed is 225 feet by 225 feet or 1.162 acres. The bulk of the property is contained in proposed Lot 4. Three of the lots are shown as peripheral lots for a larger development under separate ownership. B. EXISTING CONDITIONS: The site is a vacant tree covered site with a single building located along Colonel Glenn Road near the I-430 interchange. The site slopes to the north from Colonel Glenn Road. There are a number of non-residential uses in the area including an automobile dealership, a movie theater, a nursing school and a strip March 11, 2004 SUBDIVISION ITEM NO.: D (Cont.) FILE NO.: S-1413 2 office/showroom/warehouse development to name a few. Further southwest of the site is a public school, Fair High School, located on David O Dodd Road. C. NEIGHBORHOOD COMMENTS: As of this writing, Staff has not received any comment from area residents. The John Barrow Neighborhood Association, the Stagecoach Dodd Neighborhood Association and all abutting property owners were notified of the Public Hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. As shown, a right-of-way dedication to 55-feet from centerline is required. An additional 10-feet dedication is required at the new street to provide a right- turn lane into the development. 2. Provide design of street conforming to the Master Street Plan standards. Construct one-half street improvement to the street including a 5-foot sidewalk with the planned development. 3. Storm water detention ordinance applies to this property. 4. Prepare a letter of pending development addressing streetlights as required by Section 31-403 of the Little Rock code. Contact Traffic Engineering at (501) 379-1813 (Steve Philpot) for more information regarding street light requirements. 5. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Site grading and drainage plans will need to be submitted and approved prior to the start of construction. 6. Driveway locations and widths do not meet the traffic access and circulation requirements of Sections 30-43 and 31-210. The driveway access for Lot 1 should be located a minimum 250-feet back from the right-of-way line of Colonel Glenn Road. Likewise, the median cut should be closed within this area. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer main extension required with easements, if service is required for the project. Contact the Little Rock Wastewater Utility at 688-1414 for additional details. Entergy: A 10-foot easement is required for 1Ø or 3Ø underground service. A 30-foot easement is required for 1Ø or 3Ø overhead service. Contact Entergy at 954-5151 for additional details. Center-Point Energy: Approved as submitted. March 11, 2004 SUBDIVISION ITEM NO.: D (Cont.) FILE NO.: S-1413 3 SBC: No comment received. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. The Little Rock Fire Department needs to evaluate this site to determine the location of proposed fire hydrant(s). This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact CAW at 992-2438 for additional details. Fire Department: Approved as submitted. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: (January 8, 2004) Mr. Pat McGetrick was present representing the request. Staff stated the proposed request was a preliminary plat to include the development of the site under the criteria of the existing C-2 zoning. Staff stated the three parcels did not meet ordinance requirements if the total area was not included. Staff questioned why the larger tract had not been indicated as a part of the plat area. Mr. McGetrick stated the developer was not ready to include the large tract as a part of the development plan. Staff stated the plat would have to include the tract to be considered. Staff stated the area the three lots were being subdivided from would also be a part of the proposed preliminary plat. Public Works comments were addressed. Staff stated street improvements along Colonel Glenn Road would be required all at one time and not phased. Staff stated it was not logical or practical to phase the street improvements along the roadway. There was also a discussion concerning the driveway, location and access to the adjoining properties. Staff stated the driveway to access Lot 1 should be a minimum of 250-feet back from the right-of-way line of Colonel Glenn Road. March 11, 2004 SUBDIVISION ITEM NO.: D (Cont.) FILE NO.: S-1413 4 Staff noted various comments from the various other reporting agencies. Staff suggested Mr. McGetrick contact them individually with questions or for additional information. There, being no further items for discussion, the Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant has submitted a revised preliminary plat to staff addressing most of the issues raised at the January 8, 2004 Subdivision Committee meeting. The applicant has indicated the total land area containing 87.137 acres. The proposed lots range in size from 1.4 acres to 82.44 acres. The applicant has indicated street improvements will be constructed to the boundary streets as lots are final platted. Access to proposed Lots 1, 2 and 3 will be located along the rear of the proposed lot and adjacent to the large lot (proposed Lot 4). The applicant has indicated a 30-foot access and utility easement to serve these lots. The applicant has indicated the driveway to align with the drive located south of the site, across Colonel Glenn Road. Staff is supportive of the proposed driveway location and the proposed access to the peripheral lots. Staff is supportive of the proposed preliminary plat. The applicant has indicated development consistent with site area requirements per the zoning ordinance. The ordinance requires a minimum site area for the district to be five acres, except in those instances where a subdivision site plan and plat proposes peripheral lots and multiple ownership. The ordinance indicates the Commission shall establish the size, orientation and access to multiple lot C-2 developments with special emphasis on interior circulation, curb cuts and siting of physical improvements. Staff feels the applicant has done in good job in placing access points within the development to limit conflicts and allow for the best possible interior circulation. The applicant has not indicated any driveway locations on the 60-foot access easement into the larger parcel. Staff feels this will help to minimize any potential conflicts. To Staff’s knowledge there are no outstanding issues associated with the proposed request. Staff feels the proposed preliminary plat should have minimal to no adverse impact on adjoining properties. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. March 11, 2004 SUBDIVISION ITEM NO.: D (Cont.) FILE NO.: S-1413 5 PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Pat McGetrick was present representing the request. There were no registered objectors present. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented a recommendation of approval subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: E FILE NO.: LU04-01-01 Name: Land Use Plan Amendment - River Mountain Planning District Location: Northwest corner of Cantrell Rd. at Taylor Loop Rd. Request: Transition to Commercial Source: Frank Riggins, The Mehlburger Firm PROPOSAL / REQUEST: Land Use Plan amendment in the River Mountain Planning District from Transition to Commercial. The Commercial category includes a broad range of retail and wholesale sales of products, personal and professional services, and general business activities. Commercial activities vary in type and scale, depending on the trade area that they serve. The applicant wishes to develop the property for a commercial retail shopping center. Staff is not expanding the application since the Land Use Plan in this area was reviewed within 10 months ago. EXISTING LAND USE AND ZONING: The property is vacant land currently zoned R-2 Single Family and is about 4.27 acres ± in size. The vacant land to the north is zoned R-2 Single Family while the property to the east consists of vacant property zoned C-3 General Commercial (owned by the applicant) and a shopping center farther to the east also zoned C-3. A drug store zoned Planned Development-Commercial sits next to the application area, while further to the south is a Planned Commercial Development for a bank on the south side of Cantrell east of Taylor Loop, a house zoned R-2 at the southeast corner of Cantrell and Taylor Loop, a bank zoned Planned Office Development on the southwest corner of Cantrell and Taylor Loop, and an antique store zoned PCD on the south side of Cantrell west of Taylor Loop Road. The property to the west is a large lot single-family house zoned R-2. FUTURE LAND USE PLAN AND RECENT AMENDMENTS: On August 19, 2003 a change was made from Transition to Commercial at 14410 Cantrell Road about 1/3 of a mile to the east of the applicant’s property to accommodate proposed development. March 11, 2004 SUBDIVISION ITEM NO.: E (Cont.) FILE NO.: LU04-01-01 2 On February 18, 2003 multiple changes were made from Transition and Low Density Residential to Suburban Office, Single Family, Commercial, Park / Open Space, Office, and Public Institutional within a 1 mile radius of the application area along both sides of Cantrell Road to recognize existing conditions. On July 17, 2001 a change was made from Single Family to Commercial at Pankey Park a little less than 1 mile to the east of the study area to recognize existing conditions. On April 20, 1999 multiple changes were made from Single Family and Low Density Residential to Commercial, Office, Multifamily, and Park / Open Space at Cantrell and Black Road about a ½ mile to the east of the property in question to accommodate proposed development. The applicant’s property is shown as Transition on the Future Land Use Plan. The neighboring properties to the east are shown as Commercial. The land to the northeast is shown as Transition. The neighboring property to the west is shown as Transition while the neighboring property to the north is shown as Single Family. MASTER STREET PLAN: Cantrell Road is shown on the Master Street Plan as a Principal Arterial and is built as a four-lane highway with an additional center turn lane. There is a Class I Bikeway shown starting at the intersection of Cantrell Road and Taylor Loop Road running south from Cantrell Road to Alexander Road. This bikeway begins on the south side of Cantrell Road opposite from the applicant’s property and would not be affected by the proposed amendment. The applicant’s property does not front directly onto Cantrell Road. However, the property would be accessed from a stub-out built on the north end of the Cantrell / Taylor Loop intersection. Improvements would need to be made to the Taylor Loop stub-out to insure access to the applicant’s property. PARKS: The Little Rock Parks and Recreation Master Plan of 2001 shows the Taylor Loop Park located a short distance to the southwest of the applicant’s property. Taylor Loop Park is about 35.0+ acres. Taylor Loop Park is listed as an undeveloped Community Park intended to remain as a passive open space parcel of undeveloped land and is designed to serve the open space needs of several neighborhoods. March 11, 2004 SUBDIVISION ITEM NO.: E (Cont.) FILE NO.: LU04-01-01 3 HISTORIC DISTRICTS: There are no historic districts that would be affected by this amendment. City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the River Mountain Neighborhood Action Plan. The Sustainable Natural Environment goal listed an objective of promoting the vigorous enforcement of the Landscaping & Excavation Ordinance. This action could result in the removal of trees in order to accommodate the development of uses possible in the Commercial land use category. ANALYSIS: The application area is located in an area of expanding commercial development. Most of the property shown as Commercial in the vicinity of the applicant’s property is developed with existing commercial uses. For some Commercial uses, such as the larger retail uses, the land available is built-out. For some of the less intense commercial uses some vacant land remains available. This application will expand the area already shown as Commercial at the intersection of Cantrell and Taylor Loop Roads. The commercial node located at the intersection of Cantrell and Taylor Loop is affected by uses located at Cantrell and Pinnacle Valley Road. The close proximity of intersections between two Minor Arterials with Cantrell Road creates pressure to develop both intersections with non-residential uses, which would result in a large node of non-residential uses on Cantrell Road with a center on both intersections creating a “double node.” However, the creek and flood-plain running parallel to Pinnacle Valley Road with the accompanying land use designation of Park / Open Space should be used to minimize the intensification of non-residential uses expanding northward from Cantrell Road from Taylor Loop to Pinnacle Valley Road. If the stub-out at the north end of the Taylor Loop / Cantrell intersection is extended further to the north to form a link with Pinnacle Valley Road, the stub-out would result in a link between two Minor Arterials and create pressure to develop non-residential uses to the north, as well as resulting in a street that would be used as an arterial even though it would not be intended or designed to be used as such. The development of the applicant’s property should be done in a manner that would limit non-residential use expansion to the north and be done in such a way to buffer the area shown as Single Family to the north and the existing R-2 residential units to the west. March 11, 2004 SUBDIVISION ITEM NO.: E (Cont.) FILE NO.: LU04-01-01 4 The current category of Transition shown for the applicant’s property is intended to serve as a step between less intense land uses and more intense land uses. The Transition shown for the applicant’s property provides a step down of intensity from the Commercial uses to the east to the less intense uses to the west and from the Commercial fronting Cantrell Road to the Single Family shown to the north. A change to Commercial would reduce the buffer between the intense uses fronting Cantrell Road and the less intense uses located to the north and west. This action would also reduce the amount of land available for office or residential development along Cantrell Road in areas shown as Transition. The pattern for office developments in the area has been to show Office or Suburban Office to recognize existing offices. The changes to Office and Suburban Office have reduced the likelihood of new residential development fronting Cantrell Road. However, most of the new residential development has taken place in areas shown as Single Family, Low Density Residential, and Multi- family on land not directly accessed from Cantrell Road. The Transition category along Highway 10 accommodates mixture of office or residential uses intended to prevent the development of commercial strips along Cantrell Road. The pattern for new office developments in areas shown as Transition has been the conversion of residential structures into offices. The application area is located in an area of expanding Commercial development. Most of the property shown as Commercial in the vicinity of the applicant’s property is developed with existing Commercial uses. For some commercial uses, such as the larger retail uses, the land available is built-out. For some of the less intense Commercial uses some vacant land remains available. Much of the area shown as Transition to the south and west of the applicant’s property was changed on February 18, 2003 Board of Directors meeting. The changes discussed at the January 9, 2003 Planning Commission involved a proposed change from Transition to Commercial to recognize the drug store adjacent to the application area fronting Cantrell Road and a change from Transition to Suburban Office to the west along Cantrell Road east of Rummel Road where it was felt that future residential development was unlikely. The areas west of the applicant’s property and along Pine Mountain Road remained shown as Transition and consist of land developed with residential uses. The areas shown as Transition were preserved do in large part to the vacant land available for future residential development. The remaining areas shown as Transition could also provide access to areas shown as Single Family, which do not have direct access to Cantrell or Pinnacle Valley Roads. March 11, 2004 SUBDIVISION ITEM NO.: E (Cont.) FILE NO.: LU04-01-01 5 NEIGHBORHOOD COMMENTS: Notices were sent to the following neighborhood associations: Pleasant Valley Property Owners Association, River Valley Property Owners Association, Pankey Community Improvement Association, Piedmont Neighborhood Association, Pleasant Forest Neighborhood Association, Secluded Hills Property Owners Association, Walton Heights-Candlewood Neighborhood Association, Westbury Neighborhood Association, Westchester/Heatherbrae Property Owners Association, Chenal Ridge Property Owners, and Charleston Heights/North Rahling Road N.A. Staff has not received comments from area residents or Neighborhood Associations at the time of this writing concerning this change. STAFF RECOMMENDATIONS: Staff believes the change is appropriate with a required PZD to review any development for compatibility of massing and relationship issues. PLANNING COMMISSION ACTION: (January 29, 2004) The item was placed on the consent agenda for deferral to the March 11, 2004 Planning Commission meeting. A motion was made to wavier the by-laws for a five-day notice to defer prior to the Planning Commission meeting. That motion was made and approved with a vote of 11 ayes, 0 noes, and 0 absent. A motion was made to approve the consent agenda and was approved with a vote of 11 ayes, 0 noes and 0 absent. PLANNING COMMISSION ACTION: (March 11, 2004) The item was placed on the consent agenda for approval. A motion was made to approve the consent agenda and was approved with a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: E.1 FILE NO.: Z-7022-A NAME: Cantrell Loops Retail Center Short-form PCD LOCATION: North of Cantrell Road at Taylor Loop DEVELOPER: Grayson Revocable Trust 5317 JFK Boulevard North Little Rock, AR 72116 ENGINEER: The Mehlburger Firm 201 South Izard Street Little Rock, AR 72201 AREA: 4.265 Acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 CURRENT ZONING: C-3/R-2 ALLOWED USES: Retail and Single-family PROPOSED ZONING: PCD PROPOSED USE: C-3 listed retail uses VARIANCES/WAIVERS REQUESTED: None requested. BACKGROUND: The Little Rock Planning Commission reviewed and approved a proposed preliminary plat and recommended approval of a proposed rezoning request for this site at their May 31, 2001 Public Hearing. The Little Rock Board of Directors adopted Ordinance No. 18,516 on July 3, 2001, establishing Cantrell Loops Subdivision (Lot 1) Short-form March 11, 2004 SUBDIVISION ITEM NO.: E.1 (Cont.) FILE NO.: Z-7022-A 2 PCD. Lot 2, the lot currently under review was not rezoned as a part of the request and remains zoned C-3 and R-2. A. PROPOSAL/REQUEST: The site is located north of Cantrell Road at the Taylor Loop Road intersection. The western portion of the site is currently zoned R-2, Single-family while the eastern portion of the site is zoned C-3, General Commercial. The proposed site plan indicates two (2) buildings totaling 38,400 square feet and 189 parking spaces. The applicant has indicated the main façade of the buildings will be a maximum of 19’-4” above the finished grade and the tower element will be a maximum of 25’-0” above finished grade. The site plan indicates the lot will take access from an existing driveway extending north from the intersection of Cantrell Road and Taylor Loop Road. The intersection is controlled by a traffic signal. The applicant has also indicated storm water detention storage will be provided for the development on-site. B. EXISTING CONDITIONS: The site is mostly wooded along the northern perimeter and vacant grass covered along Cantrell Road. There is a Walgreen’s Store located on Lot 1 of the development and the driveway to serve the development and a traffic signal has been installed at the intersection with Cantrell Road and Taylor Loop Road. There is a commercial development located to the east, with both occupied and vacant single-family residences to the west. There are commercial uses at the southwest corner of Cantrell Road and Taylor Loop Road, with a vacant single- family residence at the southeast corner. The property to the north is undeveloped and zoned R-2, Single-family District. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has received several phone calls (as a result of the posted sign) from persons requesting additional information on the application. All property owners located within 200-feet of the proposed development, all residents who could be identified located within 300-feet of the proposed development, the Westchester/Heatherbrae, the Secluded Hills, the Westbury and the Charleston Height/North Rahling Road Neighborhood Associations were notified of the public hearing. March 11, 2004 SUBDIVISION ITEM NO.: E.1 (Cont.) FILE NO.: Z-7022-A 3 D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Site grading and drainage plans will need to be submitted and approved prior to the start of construction. 2. Storm water detention ordinance applies to this property. Show the proposed location for storm water detention facilities on the plan. 3. Traffic Engineering recommends a wider street width (36-feet) into the shopping center (24-feet is provided). 4. On site striping and signage plans should be forwarded to Public Works, Traffic Engineering for approval with the site development package. One-way traffic should be provided in the aisle areas near the drive through windows. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Contact the Little Rock Wastewater Utility at 688-1414 for additional details. Entergy: A 10-foot easement is required for 1Ø or 3Ø underground service or a 30-foot easement is required for 1Ø or 3Ø overhead service along the northern and eastern perimeters. Contact Entergy at 954-5162 for additional details. Center-Point Energy: Approved as submitted. SBC: No comment received. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. Contact Central Arkansas Water regarding the size and location of the water meter(s). A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all meter connections. Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer’s expense. Contact CAW at 992-2438 for additional details. Fire Department: Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional information. County Planning: No comment received. March 11, 2004 SUBDIVISION ITEM NO.: E.1 (Cont.) FILE NO.: Z-7022-A 4 CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: This request is located in the River Mountain Planning District. The Land Use Plan shows Transition for this property. The applicant has applied for a Planned Commercial Development for a new commercial building. A land use plan amendment for a change to Commercial is a separate item on this agenda. (File No. LU04-01-01 Item No. 6) City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the River Mountain Neighborhood Action Plan. The Sustainable Natural Environment goal listed an objective of promoting the vigorous enforcement of the Landscaping & Excavation Ordinance and also lists an action statement encouraging the preservation of the Highway 10 Design Overlay District. Landscape: The proposed eastern perimeter landscape strip width is 3,079 square feet less than the average 25-feet required by the Highway 10 Overlay District. A 6-foot high opaque screen, either a wooden fence with its face side directed outward, a wall, or dense evergreen plantings, is required along the northern and western perimeters of the site. An irrigation system to water landscaped areas will be required. Prior to obtaining a building permit, it will be necessary to provide landscape plans stamped with the seal of a Registered Landscape Architect. G. SUBDIVISION COMMITTEE COMMENT: (January 8, 2004) Mr. Frank Riggins was present representing the request. Staff stated the request to rezone the site from C-3 and R-2 to PCD to allow the development of a retail center. Staff indicted to Mr. Riggins there were additional items necessary to complete the review. Staff requested details concerning any proposed signage, the days and hours of operation, any fencing and to provide the maximum building height in the general notes section of the site plan. Staff also noted any additional site lighting must be low level and directed inward away from residentially zoned properties. March 11, 2004 SUBDIVISION ITEM NO.: E.1 (Cont.) FILE NO.: Z-7022-A 5 Staff requested the applicant provide details concerning the rear of the development. Staff stated the buildings would abut single-family zoned property and care should be taken to limit the impact of the commercial development on the future single-family homes. Public Works comments were addressed. Staff requested Mr. Riggins provide the location of detention storage on the proposed site plan. Staff requested the driveway be increased to 36-feet to allow for fewer traffic conflicts and ease of circulation. Landscaping comments were addressed. Staff stated screening would be required along the northern and western perimeters of the site. Staff also stated the landscaping strip along the eastern perimeter should be a minimum of 25-feet as required by the Highway 10 Design Overlay District. There being no further items for discussion, the Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plan to staff on January 14, 2004, addressing the issues raised at the January 8, 2004 Subdivision Committee meeting. The applicant has indicated signage will comply with the Highway 10 Design Overlay District or a maximum of ten feet in height and one hundred square feet in area. Staff is supportive of the proposed signage. The applicant has indicated 189 parking spaces on the proposed site plan. The applicant has also indicated two buildings containing a total of 38,500 square feet. The typical minimum parking requirement for a development of this type would be 128 parking spaces. The proposed parking is sufficient to meet the minimum parking demand for a commercial development. The applicant has indicated drive-through lanes on the ends of each of the buildings. Staff is not supportive of the placement of the drive-through lanes as presented. The proposed drive through lanes cross traffic both entering and exiting the drive. The existing circulation does not lend itself to drive through lanes on the site. Staff recommends the applicant provide details concerning how the drive-through will function without traffic conflict or remove the drive- through lanes from the proposed site plan. The applicant has indicated the rear of the building will be used in screening but has indicated a drive to the rear of the eastern building. The western building is proposed with limited openings; only those required to meet fire code. The applicant has indicated the building will be finished on all non public sides using a March 11, 2004 SUBDIVISION ITEM NO.: E.1 (Cont.) FILE NO.: Z-7022-A 6 combination of decorative MCU from finished grade to the finished floor level and decorative metal siding from the finished floor to the roof. The applicant has indicated the maximum building height will be twenty-five feet. Along with this decorative finish, a number of evergreen trees will be planted in the area designated for landscaping on the plan to exceed the number required by ordinance. The applicant has stated there will be no deliveries taken in the rear of the buildings. The area to the north is zoned R-2, Single-family and staff feels efforts should be made to screen the adjoining properties. Staff feels the development should make efforts to limit the negative impact of any potential residential development. The applicant has indicated the days and hours of operation to vary depending on the particular businesses located on the site. The applicant has indicated a variety of tenants are expected to lease space in the center, including the possibility of a restaurant or two. The applicant is requesting to be allowed some flexibility in order to attract quality tenants to the development. The applicant has indicated the days and hours would be customary and common to other retail centers in the area. Staff would recommend the applicant provide details concerning the anticipated days and hours of operation. The applicant has indicated no fencing is proposed for the eastern property line. The applicant has indicated screening will be provided as required by ordinance along the perimeter of the site. The applicant has indicated detention and storage on the site plan. The proposed detention storage is a dry pond located in the front of the development adjacent to Highway 10. The applicant has not increased the driveway width to the requested 36-feet. The applicant is requesting a 24-foot drive to act as a traffic calming device. The applicant has stated a wider street might encourage higher speeds and parking along the driveway. The applicant has stated a desire to keep the driveway at the 24-feet for these stated reasons. Staff feels for better access and traffic flows a 36-foot drive is required and would recommend the driveway width be increased to 36-feet. Staff is supportive of the proposed concept but feels there are too many outstanding issues associated with the proposed request to recommend approval. Staff feels all the issues associated with the proposed request must be answered prior to approval of the proposed development. I. STAFF RECOMMENDATION: Staff recommends denial of the proposed request as filed. March 11, 2004 SUBDIVISION ITEM NO.: E.1 (Cont.) FILE NO.: Z-7022-A 7 PLANNING COMMISSION ACTION: (JANUARY 29, 2004) The applicant was present representing the request. There were no registered objectors present. Staff presented the item indicating the applicant had submitted a request for deferral to the March 11, 2004 Public Hearing. Staff stated the request would take a waiver of the By-Laws for the deferral due to the timeliness of the request. Staff stated they were supportive of the requested deferral. There was no further discussion of the item. The item was placed on the consent agenda for deferral. The motion for the waiver of the By-Laws carried by a vote of 10 ayes, 0 noes, 0 absent and 1 Recuse (Commissioner Bill Rector). The motion for deferral carried by a vote of 11 ayes, 0 noes, 0 absent and 1 Recuse (Commissioner Bill Rector). PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Frank Riggins was present representing the request. There were no registered objectors present. Staff stated the applicant had submitted a revised plan to staff addressing most of the issues and concerns. Staff noted concerns of an adjoining property owner related to drainage and landscaping. Staff presented a recommendation of approval subject to compliance with the conditions outlined in paragraphs D, E, F and H of the above report. Staff also presented a recommendation the driveway adjacent to the proposed drive- through window be marked as one-way traffic and the parking be angled as proposed on the revised site plan. Staff presented a recommendation related to screening indicating screening be provided along the northern and western perimeters as proposed by an eight foot wood fence and additional plantings as required by the current landscape ordinance. Staff presented a recommendation of approval of the request to allow an off-premise sign on proposed Lot 3 to serve proposed Lot 2 and staff recommended signage be limited to a single sign to serve both lots consistent with signage allowed by the Highway 10 Design Overlay District or a maximum of ten feet in height and one hundred square feet in area. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: F FILE NO.: Z-7563 NAME: Rock House Short-form POD LOCATION: 715 North University Avenue DEVELOPER: Rock House, LLC 11500 North Rodney Parham Road Little Rock, AR 72212 ENGINEER: Rickett Engineering, Inc. 78 Aberdeen Drive Little Rock, AR 72223 AREA: 1.72 Acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 CURRENT ZONING: R-5, Urban Residential District ALLOWED USES: High Density Residential Units of not more than 36-units per acre PROPOSED ZONING: POD PROPOSED USE: Office (General and Professional) with the 25 percent of the gross floor area being available for selected commercial uses VARIANCES/WAIVERS REQUESTED: None requested. A. PROPOSAL/REQUEST: The applicant is proposing the placement of a two-story office building consisting of 18,000 square feet of general and professional office uses with provisions for some light commercial uses should they fit with office occupancy. The proposed March 11, 2004 SUBDIVISION ITEM NO.: F (Cont.) FILE NO.: Z-7563 2 site plan includes fifty-nine on-site parking spaces. The applicant is requesting to be allowed 25 percent of the gross floor area (4,500 square feet) be allowed to be utilized by the following listed uses: Barber/Beauty Shop, Book and Stationary Store, Drugstore, Florist, Optic Shop, Clothing, Hobby Shop, Jewelry, or Tailor Shop. Included in the filing is a petition for abandonment of Grant Street and “G” Street. Grant Street currently ends at the intersection of “F” Street. The applicant is proposing an extension of Grant Street approximately 120 feet from “F” Street to the property line and creating adequate turn around in the parking lot for emergency vehicles. B. EXISTING CONDITIONS: The property now consists of twelve residentially zoned lots in Blocks 9 and 10 of the Lincoln Park Subdivision and a portion of Grant Street which has never been constructed. The property is bounded by University Avenue to the west, “G” Street (not constructed) to the north, a closed alley to the east, and a dwelling and small office building to the south. Steep grades to the east and north lead down to a drainage canal. Access to the site from University Avenue is right turn only. An abandoned house with a stone exterior currently sits on the site. Frontage along University Avenue is predominantly occupied by office and commercial uses, with a few remaining single-family dwellings. To the east of the site are residential uses adjacent to the drainage canal. Other uses in the area include the Catholic Boys school a strip retail center and a public library. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. The Hillcrest Residents Neighborhood Association, Evergreen Neighborhood Association, all owners of property located within 200-feet of the site and all residents who could be identified located within 300-feet of the site were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. The site plan as proposed cannot be approved. An un-stable fill was placed on this site in the regulated floodway of Coleman Creek and there are un- resolved enforcement issues. A large portion of the site is within the mapped floodway and floodplain. Before site plan review, a restoration plan must be provided for the site, and a required for a Letter of Map Revision must be March 11, 2004 SUBDIVISION ITEM NO.: F (Cont.) FILE NO.: Z-7563 3 prepared and submitted through this office to the Federal Emergency Management Agency. 2. All fill slopes must conform to the land alteration ordinance. Slopes must be at 3:1 or benched with erosion protection provided. 3. A special grading permit for Flood Hazard Areas will be required per Section 8-283 prior to any construction. Approval from the Little Rock District Corps of Engineers may also be required. 4. University Avenue is classified on the Master Street Plan as a principal arterial. Dedication of right-of-way to 55-feet from centerline will be required. 5. Provide design of street conforming to the Master Street Plan. Construct one- half street improvement to the street including 5-foot sidewalk with the planned development. The right turn lane for “H” Street would need to be extended across the frontage. 6. Contact Traffic engineering at (501) 379-1816 for guidance of the driveway location and configuration. The design must provide for a directional right-in, right-out island and minimize traffic conflicts near the right-of-way line. 7. Storm water detention ordinance applies to this property. 8. Dedication of the Floodway and a 25-foot access easement adjacent to the floodway will be required. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Existing sewer main on property. No permanent construction within five foot either side of existing sewer main. Contact Little Rock Wastewater Utility at 688-1414 for additional details. Entergy: No comment received. Center-Point Energy: Approved as submitted. SBC: The proposed right-of-way will require approval from the SBC right-of-way engineer. Contact SBC at 373-5112 for additional details. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met before service is resumed. The Little Rock Fire Department needs to evaluate this site to determine the location of public and/or private fire hydrant(s), which will be required. A water main extension and additional fire hydrant(s) will be installed at the Developer’s expense. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact CAW at 992-2438 for additional details. March 11, 2004 SUBDIVISION ITEM NO.: F (Cont.) FILE NO.: Z-7563 4 Fire Department: Increase the south driveway to a minimum of 20-feet in width. Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional information. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: This request is located in the Heights – Hillcrest Planning District. The Land Use Plan shows Office for this property. The applicant has applied for a Planned Office Development for O-1 Quiet Office Uses. The request does not require a change to the Land Use Plan. City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the Hillcrest Neighborhood Action Plan. The Zoning & Land Use goal lists an objective of no net loss of residential units by demolition or conversion to other uses. Landscape: A portion of the proposed land use buffer along the southern perimeter is less than the 6-foot 9-inch minimum allowed. This takes into account the reduction allowed within the designated mature area of the city. A 6-foot high opaque screen, either a wooden fence with its face side directed outward, a wall or dense evergreen plantings, is required to help screen this property from the residential properties to the east and south. An irrigation system to water landscaped areas will be required. G. SUBDIVISION COMMITTEE COMMENT: (January 8, 2004) The applicant was present representing the request. Staff stated the site plan as proposed could not be approved. Staff stated an un-stable fill was placed on the site in the regulated floodway of Coleman Creek and there were un-resolved enforcement issues. Staff stated a large portion of the site was within the mapped floodway and floodplain. Staff stated a restoration plan had been filed and approved by the Public Works Department. Staff stated before a site plan review could be approved located in the floodway, a restoration plan would have to be provided for the site, and a Letter of Map Revision prepared and submitted through the City to the Federal Emergency Management Agency. Staff stated the process was quite lengthy and they felt the request should be withdrawn awaiting the FEMA decision. March 11, 2004 SUBDIVISION ITEM NO.: F (Cont.) FILE NO.: Z-7563 5 Additional Planning, Landscaping and Public Works comments were addressed to allow the applicant information that would be expected if and when the site were approved for development. There being no further items for discussion, the Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised preliminary site plan to staff addressing most of the issues raised at the January 8, 2004 Subdivision Committee meeting. The applicant has indicated the previously approved restoration plan will be implemented for the site. Areas of fill will be removed from the floodway and the slopes will be flattened to a maximum of 3:1. The applicant has indicated an easement along the rear parking area will be dedicated for access to the floodway. The applicant has also indicated a dedication of right-of-way for University Avenue from the existing centerline of fifty-five feet as required by the Master Street Plan ordinance. The applicant has also indicated a right-turn lane will be installed adjacent to the site and the applicant will coordinate with Traffic Engineering to determine the exact requirements. The applicant has indicated the proposed signage on the site plan along with a note stating the signage will be a ground mounted sign and comply with the sign area allowed in office zones or a maximum of six feet in height and seventy-two square feet in area. Staff is supportive of the proposed signage. The applicant has provided a proposed maximum building height of forty-five feet. The applicant is proposing a two story building. The proposed elevation indicates the building will contain a metal roof and the building will contain glass fronts. The applicant has indicated architectural plans have not been finalized indicating construction materials have not been fully determined. Staff would suggest the building follow design recommendations set forth by the Urban Land Institute for redevelopment of the area. The site lies in the secondary area reviewed by the Urban Land Institute for redevelopment possibilities (University Avenue from Lee Street north to Evergreen Drive. The primary focus of the study was the area along West Markham Street from Pine Street to University Avenue and on University Avenue from West Markham Street to Lee Street.) “The panel did not suggest changes of the northern portion of the secondary area, other than to continue to recognize it as a Hillcrest neighborhood border that needs to be protected.” The panel suggested the adoption of specific guidelines and controls that would result in less visual clutter March 11, 2004 SUBDIVISION ITEM NO.: F (Cont.) FILE NO.: Z-7563 6 and provide greater convenience for pedestrians. The panel also stated the design guidelines can help to safeguard the Hillcrest neighborhood and concentrate mixed use development. The panel suggested the adoption of design guidelines that would ensure compatibility with the bordering Hillcrest residential neighborhood. Staff feels the building could be designed and constructed to enhance the neighborhood with regard to architectural style and construction materials. The applicant has indicated a desire to close portions of two (2) streets located within the development. The applicant has indicated a portion of Grant Street will be closed from the applicant’s northern property line to the applicant’s southern property line or approximately 210 feet. The applicant is also requesting the closure of a portion of “G” Street from University Avenue to the applicant’s eastern property line. The applicant is the sole owner of the properties of Grant Street. There is an adjoining property owner to the north, which would gain the northern portion of the abandoned Grant Street right-of-way. Staff has been contacted by the property owner located to the south of the site stating his desire to close Grant Street from “F” Street to the intersection with “G” Street (the northern boundary of the applicant’s property). There are existing utilities located in these right-of-ways and all would be required to be maintained as utility easements. Staff feels this issue should be resolved prior to approval of the proposed rezoning request. Staff feels should the street be closed from “F” Street to the applicant’s southern property line the site plan will change significantly. The proposed site plan indicates a total of fifty-nine parking spaces. The typical minimum parking required for an 18,000 square foot office building would be forty-five parking spaces. The proposed parking is more than adequate to meet the typical minimum parking demand. Staff is supportive of the proposed use of the property as general and professional office uses and the allowance of up to twenty-five percent of the gross floor area to be utilized by the specified uses listed in paragraph A of this report. Since the applicant is requesting only general and professional office ues for seventy-five percent of the gross floor area, not a broader list of uses, such as O-1, O-2 or O-3 with the associated accessory uses; staff supports the specific proposed uses for the remaining twenty-five percent. The proposed use is consistent with the future land use plan. Staff would however suggest the overall design be given consideration and the recommendations of the Urban Land Institute be followed to protect the integrity of the neighborhood. Staff also recommends the applicant resolve outstanding issues related to the closure of “F” Street prior to March 11, 2004 SUBDIVISION ITEM NO.: F (Cont.) FILE NO.: Z-7563 7 I. STAFF RECOMMENDATION: Staff recommends the right-of-way issue related to the closure of “F” Street be resolved prior to consideration of the rezoning request. PLANNING COMMISSION ACTION: (JANUARY 29, 2004) The applicant was present representing the request. Staff stated a portion of the request was to close Grant Street within the development. Staff stated the property owner to the south was also requesting the closure of Grant Street adjacent to his property. Staff stated if the street south of the development were closed then this would affect the proposed site plan currently submitted for review. Staff presented a recommendation of deferral to the March 11, 2004 Public Hearing to allow the owner of the property to the south sufficient time to make application for the street closure adjacent to his property and to allow the Commission to review the Grant Street street closure request at the same hearing. There was no further discussion of the item. The item was placed on the consent agenda for deferral. The motion carried by a vote of 11 ayes, 0 noes and 0 absent. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were no registered objectors present. Staff presented the item indicating a deferral was being requested. Staff stated they were requesting the deferral to the March 25, 2004 Planning Commission Public Hearing to allow the item to be discussed with an item filed for the March 25, 2004 Public Hearing related to the requested street closure. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 I T E M N O . : G Name: Chenal-Hwy 10 Ministorage, unpermitted land alteration Location: Undeveloped Lot 2, Northwest Territory Addition at 24400 Chenal Parkway north of Hwy 10 in Little Rock, Pulaski County, Arkansas Owner/Applicant: Chris Thornton, property owner. Request: Appeal the corrective action of NOV #208 which required all disturbed areas to be restored to their original condition. STAFF REVIEW: 1. Master Street Plan This portion of Chenal Parkway is a minor arterial. 2. Development Potential and Land Use This approximate 5 acre site is adjacent to Chenal Parkway north of Hwy 10. A phased C.U.P was approved for this lot 2, and lot 1 in December, 2000. The Chenal-Hwy 10 Mini-Storage was constructed on lot 1 as part of the C.U.P. The undeveloped properties to the east were recently rezoned to O3, C3 and MF-12. The zoning of the undeveloped property to the north is O3. The zoning of the undeveloped property to the south is C3 and a utility substation. The property to the west across Chenal Parkway is zoned C2 with a P.C.D. on the northwest corner of Chenal Parkway and Hwy 10. 3. Neighborhood Position Public Works has received complaints from the adjacent property owner to the east. The applicant apparently cleared approximately 1.72 acres of his property. March 11, 2004 SUBDIVISION ITEM NO.: G (Cont.) NOV #208 2 STAFF ANALYSIS: The applicant is the owner of the Chenal-Hwy 10 Mini Storage (“mini storage”). The mini storage and lot 2 were approved as a phased C.U.P. in December, 2000. Notice of Violation #208 (“NOV”) was issued to the applicant for un- permitted clearing and excavating of lot 2 and 1.72 acres of the adjacent property to the east that the applicant does not own. The cleared area is not visible from Chenal Parkway. The applicant proposes to develop a portion of lot 2 per the approved C.U.P. and plans to restore the remaining disturbed area per Section 29-170(c) of the land alteration regulations. The restoration consists of restoring all off-site slopes to their approximate original contours, constructing on-site slopes to a configuration that complies with the land alteration ordinance, grading all excavated areas to obtain proper drainage; replanting trees on adjacent property; and establishing vegetation on all disturbed areas. Public Works is in support of the proposed corrective action of NOV #208 consisting of partial site development and restoration of remaining disturbed areas. SUBDIVISION COMMITTEE COMMENT: (JANUARY 8, 2004) Staff presented a short synopsis of the case. The applicant was not present. PLANNING COMMISSION ACTION: (JANUARY 29, 2004) The applicant was not present. There were no registered objectors present. Staff stated the applicant had failed to notify adjacent property owners as required by the Land Alteration Ordinance. Staff presented a recommendation for the item be deferred to the March 11, 2004 to allow for proper notification. There was no further discussion of the item. The item was placed on the consent agenda for deferral. The motion carried by a vote of 11 ayes, 0 noes and 0 absent. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was not present. There were no registered objectors present. Staff stated they were requesting the item be deferred to the March 25, 2004 March 11, 2004 SUBDIVISION ITEM NO.: G (Cont.) NOV #208 3 Planning Commission Public Hearing. Staff stated the reason for the deferral was to allow the item to be discussed with an item which had been filed for the March 25, 2004 Public Hearing. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: H FILE NO.: Z-7573 NAME: The Furniture Club Warehouse – Conditional Use Permit LOCATION: 6805 West 12th Street, Suite “D” OWNER/APPLICANT: Danny Thomas Properties/Doug Berryhill PROPOSAL: A conditional use permit is requested to allow a retail furniture store to be operated in one lease space of this I-2 zoned, multibuilding site. 1. SITE LOCATION: The property is located on the south side of West 12th Street, one lot east of Westpark Drive. The lease space in question is located in the second building south of the street. 2. COMPATIBILITY WITH NEIGHBORHOOD: The property is located within a large, office warehouse park. The buildings surrounding this site contain a variety of office, office warehouse and commercial uses. Beyond the office park, the area contains a variety of uses and zonings including a cemetery, a city park, a residential neighborhood, the Centers for Youth and Families and additional commercial and industrial uses. Allowing this retail furniture store in one lease space will have no effect on the surrounding neighborhood. All owners of property located within 200 feet of the site, all residents within 300 feet who could be identified and the Leander and University Park Neighborhood Associations were notified of this request. 3. ON SITE DRIVES AND PARKING: A 5,000 square foot retail use normally requires 16 on-site parking spaces. The nature of this use is such that the parking requirement is much lower. There is substantial parking available around the 3 buildings that comprise this development. Several of the lease spaces appear to be occupied by warehouse uses that have a low parking requirement. There is more than sufficient parking available to accommodate the proposed use. March 11, 2004 SUBDIVISION ITEM NO.: H (Cont.) FILE NO.: Z-7573 2 4. SCREENING AND BUFFERS: Since this is an existing development with no changes proposed, no landscaping upgrade or screening is required. 5. PUBLIC WORKS COMMENTS: 1. No Comments. 6. UTILITY, FIRE DEPT. AND CATA COMMENTS: Wastewater: Sewer available, not adversely affected. Entergy: No Comments received. CenterPoint Energy: Approved as submitted. Southwestern Bell: Approved as submitted. Water: No Comments received. Fire Department: Approved as submitted. County Planning: No Comments. CATA: A CATA Bus Route is located on West 12th Street. SUBDIVISION COMMITTEE COMMENT: (JANUARY 15, 2004) The applicant was present. Staff presented the item and noted additional information was needed regarding days and hours of operation, number of employees and signage. The applicant responded the business would be open Thursday through Saturday, 11:00 a.m. to 6:00 p.m. and Sunday, 1:00 p.m. to 4:00 p.m. He stated there would be two employees and signage would consist only of a wall sign and a panel on the complex tenant sign. The Committee determined there were no issues and forwarded the item to the full Commission. March 11, 2004 SUBDIVISION ITEM NO.: H (Cont.) FILE NO.: Z-7573 3 STAFF ANALYSIS: The I-2 zoned property at 6805 West 12th Street is occupied by a one-story, 30,000 square foot, office warehouse building. The building is one of three that comprise the overall development. The applicant proposes to operate a retail furniture store in one, 5,000 square foot lease area of the building. The retail use requires a conditional use permit in I-2. No changes are proposed to the site. The furniture store will operate Thursday through Saturday, 11:00 a.m. to 6:00 p.m. and Sunday, 1:00 p.m. to 4:00 p.m. There will be two employees. Signage will consist of a wall mounted sign that complies with ordinance standards and a space on the complex tenant sign that fronts onto West 12th Street. There is no bill of assurance issue. Staff is supportive of the proposal. The building is one of many that jointly form a large, office warehouse park. There are several other non-warehouse uses in the complex; including a restaurant, offices and other retail uses. There is sufficient parking to accommodate this use. Allowing the retail furniture store in one lease area will have no effect on the surrounding neighborhood. STAFF RECOMMENDATION: Staff recommends approval of the requested conditional use permit subject to there being no storage of furniture, mattresses or packing materials outside of the building. PLANNING COMMISSION ACTION: (FEBRUARY 12, 2004) The applicant was present. There were no objectors present. Staff informed the Commission that the applicant had failed to properly complete the notification requirement and the item needed to be deferred. There was no further discussion. The item was placed on the Consent Agenda and approved for deferral to the March 11, 2004 commission meeting. The vote was 11 ayes, 0 noes and 0 absent. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present. There were no objectors present. Staff presented the item and a recommendation of approval subject to there being no storage of March 11, 2004 SUBDIVISION ITEM NO.: H (Cont.) FILE NO.: Z-7573 4 furniture, mattress or packing materials outside of the building. There was no further discussion. The item was placed on the Consent Agenda and approved as recommended by staff. The vote was 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 1 FILE NO.: S-45-A-55 NAME: Otter Creek Business Park Subdivision Preliminary Plat LOCATION: On the Southwest corner of I-30 and Mabelvale West Road DEVELOPER: 430-Investments, LLC c/o Dickson Flake Partners P.O. Box 3546 Little Rock, AR 72203 ENGINEER: McGetrick and McGetrick Engineers 319 President Clinton Avenue, Suite 202 Little Rock, AR 72201 AREA: 22.49 acres NUMBER OF LOTS: 2 FT. NEW STREET: 0 CURRENT ZONING: I-2, Light Industrial District PLANNING DISTRICT: 16 – Otter Creek CENSUS TRACT: 41.03 VARIANCES/WAIVERS REQUESTED: None requested. A. PROPOSAL/REQUEST: The applicant proposes to subdivide 22.49 acres into two non-residential lots. The lots are currently zoned I-2, Light Industrial. The proposal includes Lot 1 containing 2.75 acres and Lot 2 containing 18.66 acres. The lots will share a single drive located on the frontage road as access to the site. Each lot will also access Otter Creek South Road. The applicant has indicated dedication of right- of-way for the existing private street per the Master Street Plan. B. EXISTING CONDITIONS: The site is vacant and tree covered site is located at the intersection of Mabelvale West Road and I-30. There are large warehousing activities and smaller office/warehouse activities located in the area. Across Mabelvale West is a motel, City of Little Rock Fire Station, Southwest Hospital and an office complex with medical related offices. March 11, 2004 SUBDIVISION ITEM NO.: 1 (Cont.) FILE NO.: S-45-A-55 2 The I-30 Frontage Road is one-way adjacent to the site traveling eastbound. There is a private street located adjacent to the southern boundary of the property. The road appears to be functioning as a public street. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. All abutting property owners and Southwest Little Rock Untied for Progress were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Otter Creek South Road is shown in Public Works records as a private street, however it currently functions as a public street. The right-of-way should be dedicated on the plat, and the street constructed to Master Street Plan standards when the property on Mabelvale South develops. 2. The proposed land use would classify Mabelvale South and the I-30 Frontage Road on the Master Street Plan as commercial streets. A minimum dedication of right-of-way to 30 feet from centerline would be required. A 20 foot radial dedication of right-of-way is required at the intersection of the streets. 3. Provide design of streets conforming to the Master Street Plan. Construct one-half street improvement to these streets including 5-foot sidewalks with planned development. 4. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Site grading, and drainage plans will need to be submitted and approved prior to the start of construction. 5. Storm water detention ordinance applies to this property. 6. Prepare a letter of pending development addressing streetlights as required by Section 31-403 of the Little Rock code. Contact Traffic Engineering at (501) 379-1813 (Steve Philpott) for more information regarding street light requirements. 7. Street improvement plans shall include signage and striping. Traffic Engineering must approve completed plans prior to construction. 8. Driveway locations and widths do not meet the traffic access and circulation March 11, 2004 SUBDIVISION ITEM NO.: 1 (Cont.) FILE NO.: S-45-A-55 3 requirements of Sections 30-43 and 31-210. The lots fronting I-30 must show a shared single driveway access centered on the property line. The width of driveway must not exceed 36 feet. 9. For Lot 2, driveway access to the Frontage Road would not be allowed north of the I-30 exit ramp. Access must be through the shared drive on I-30, from Mabelvale West if approved by the Highway Department, and from Mabelvale South. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer main extension required with easements for Lot 1 if service is required for the project. Contact Little Rock Wastewater at 688-1414 for additional details. Entergy: A 10-foot easement is required along the east and south property lines of Lot 1. Contact Entergy for additional details. Center-Point Energy: Approved as submitted. SBC: Approved as submitted. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all meter connections including any metered connections off a private fire system. A water main extension will be required in order to provide service to this property. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Approved as submitted. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. March 11, 2004 SUBDIVISION ITEM NO.: 1 (Cont.) FILE NO.: S-45-A-55 4 G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Pat McGetrick was present representing the request. Staff stated the request was a preliminary plat for a two-lot plat located near Mabelvale West Road and I-30. Staff requested additional information be provided to allow the completion of their review process. Staff requested the applicant provide the name/address and source of title of the owner of the proposed preliminary plat. Staff also requested the applicant indicate the limits of the floodway and/or floodplain on the proposed plat area as well as the owners of property abutting the plat area. Staff questioned the status of the roadway located to the south of the site. Mr. McGetrick stated it appeared the roadway was a private road and his research had not shown the roadway was ever dedicated. He stated he would continue to research the issue. Staff stated dedication of right-of-way and one- half street construction would be required per the Master Street Plan. Staff stated Mr. McGetrick should contact the Highway Department to verify locations of driveway cuts along the frontage road as well as Mabelvale West Road. Staff noted comments from the other reporting departments and agencies suggesting Mr. McGetrick contact them individually for additional clarification. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plan to staff addressing the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated the source of title of the owner of the proposed plat area, the limits of the floodway and/or floodplain (no area of the proposed plat area lies within the floodway or floodplain) and the owners of abutting properties. The applicant has indicated Otter Creek South is a private street. The proposed preliminary plat indicates a dedication of right-of-way 30-feet from the centerline of the existing roadway and construction of one-half street improvements. The proposed site plan also includes a shared driveway location on the property line to serve the two lots from the I-30 Frontage Road. Each of the lots will have drives located on Otter Creek South Road. The proposed preliminary plat conforms to the minimum requirements of the Subdivision Ordinance. The minimum lot size required for an I-2, Light Industrial District zoned site is 14,000 square feet. The minimum lot size proposed is 2.75 acres; more than adequate to meet the minimum size requirement. The applicant has indicated a fifty foot front yard building line adjacent to the I-30 Frontage Road. The applicant has also indicated a shared driveway location to March 11, 2004 SUBDIVISION ITEM NO.: 1 (Cont.) FILE NO.: S-45-A-55 5 serve the development, limiting the number of curb cuts on the I-30 Frontage Road. To staff’s knowledge there are no outstanding issues associated with the proposed request. Staff feels if the proposed plat is developed as proposed, there will be minimal to no adverse impact on the adjoining properties. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Pat McGetrick was present representing the request. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented a recommendation of approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff stated if the applicant would plat a ten foot no vehicular access easement along the I-30 Frontage Road the applicant would be allowed two driveway locations along Mabelvale West Road. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 2 FILE NO.: S-45-A-56 NAME: Otter Creek Plaza Subdivision Revised Preliminary Plat LOCATION: On the Northeast corner of Otter Creek Parkway and Stagecoach Road DEVELOPER: Gene Cauley c/o Dickson Flake Partners P.O. Box 3546 Little Rock, AR 72203 ENGINEER: White-Daters Engineers #24 Rahling Circle Little Rock, AR 72223 AREA: 7.2 acres NUMBER OF LOTS: 4 FT. NEW STREET: 0 CURRENT ZONING: C-3, General Commercial District PLANNING DISTRICT: 16 – Otter Creek CENSUS TRACT: 42.08 VARIANCES/WAIVERS REQUESTED: A variance to allow the creation of a lot without public street frontage. BACKGROUND: The applicant previously proposed to subdivide this C-3 zoned, 7.2-acre tract into five non-residential lots. The plat consisted of five lots ranging in size from 0.87 acres to 2.15 acres. Shared driveways and access were to be used to limit the number of curb cuts onto the two arterials. Stagecoach Road has been constructed to Master Street Plan standard with the necessary right-of-way in place. Otter Creek Road would be widened to one-half of a 59-foot street with sidewalks as a part of the proposed plat. The applicant proposed the lots to be final platted as development for each lot became imminent. The sidewalks were to be constructed when the adjacent lot developed. The Commission approved the preliminary plat on August 7, 2003. March 11, 2004 SUBDIVISION ITEM NO.: 2 (Cont.) FILE NO.: S-45-A-56 2 A. PROPOSAL/REQUEST: The applicant is now proposing to revise the previously approved preliminary plat to allow the development of four (4) commercially zoned lots on this 7.2-acre site. The applicant has indicated three of the lots will have public street frontage from Stagecoach Road or Otter Creek Parkway but the third lot (proposed Lot 3) will be served by a private access and utility easement. The proposed lots range in size from 1.594 acres to 2.076 acres. The applicant has indicated shared drives for lots abutting the street to limit the number of curb cuts. B. EXISTING CONDITIONS: The site is vacant and has access to Otter Creek Parkway and Stagecoach Road. The area is predominately non-residential in nature with a large shopping center containing a grocery store and several neighborhood commercial type uses and a drive-in restaurant located on an out parcel. There is a large vacant C-2 zoned site located to the southwest of the site adjacent to the drive-in restaurant. The area to the south, across Otter Creek Parkway is zoned C-3 and being used as an office use. Stagecoach Road is a five lane road narrowing to two lanes at the intersection of Otter Creek Parkway and Stagecoach Road. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. All owners of property abutting the proposed site along with the Otter Creek Homeowners Association and Southwest United for Progress were notified of the Public Hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Right-of-way dedications and boundary street improvements are indicated on the plat. 2. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Site grading, and drainage plans will need to be submitted and approved prior to the start of construction. 3. Storm water detention ordinance applies to this property. 4. Align the proposed driveway on Stagecoach to match the commercial driveway to the west. March 11, 2004 SUBDIVISION ITEM NO.: 2 (Cont.) FILE NO.: S-45-A-56 3 E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer main extension required with easements for Lot 2 if service is required for the project. Contact Little Rock Wastewater at 688-1414 for additional details. Entergy: A 30-foot easement is required for all overhead 3-Phase electrical facilities. Contact Entergy for additional details. Center-Point Energy: Approved as submitted. SBC: Approved as submitted. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all meter connections including any metered connections off a private fire system. A water main extension will be required in order to provide service to this property. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Additional fire hydrants may be required. Contact the Little Rock Fire Department at 918-3752 for additional details. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Joe White was present representing the request. Staff presented an overview of the proposed preliminary plat indicating there were additional items necessary to complete the review. Staff noted the previous approval included the drives along Stagecoach Road aligning with drives located to the west. Staff requested the applicant revise the proposed plat to align the driveway on Stagecoach Road with the drive located to the west. Staff also requested the March 11, 2004 SUBDIVISION ITEM NO.: 2 (Cont.) FILE NO.: S-45-A-56 4 applicant indicate the zoning classification within the plat boundary and of abutting areas shown. Public Works comments were addressed. Staff stated the storm water detention ordinance would apply to the property and a grading permit in accordance with Section 29-186 (c) and (d) would be required prior to any land clearing or grading activities. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised preliminary plat to staff addressing the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated the proposed drive along Stagecoach Road to align with a drive located to the west. The applicant has also indicated the existing zoning classification within the proposed plat boundaries and of abutting parcels. The site is currently zoned C-3, General Commercial District, which allows the development of lots at a minimum of 14,000 square feet. The applicant has indicated the lot sizes ranging from 1.59 acres to 2.07 acres. The proposed minimum lot sizes are more than adequate to meet the minimum lot size per the Subdivision Ordinance. The applicant has indicated the development will share access through a 40-foot access and utility easement. The drive locations will be located on shared lot lines to allow the number of drives to be limited to one on each on the abutting streets. Staff is supportive of the proposed drive locations and access proposed. The applicant is requesting a variance from the Subdivision Ordinance. The applicant has indicated the creation of a lot without public street frontage. Proposed Lot 3 will be provided access through the mentioned 40-foot access and utility easement. Staff is supportive of the requested variance to allow the creation of a lot without public street frontage. Staff is supportive of the proposed request. The applicant has indicated a proposed preliminary plat for C-3 zoned property creating four individual lots and an access and utility easement to serve the development. The applicant has indicated a desire to create a commercial center style development with each of the buildings owning their own parcel. The proposed variance (creation of a lot without public street frontage) should have minimal to no adverse impact on the development of the lands due to the 40-foot access and utility easement being put in place. March 11, 2004 SUBDIVISION ITEM NO.: 2 (Cont.) FILE NO.: S-45-A-56 5 To staff’s knowledge there are no outstanding issues associated with the proposed request. Staff recommends approval of the proposed preliminary plat and the associated variance. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff recommends approval of the requested variance to allow the creation of a lot without public street frontage for proposed Lot 4. PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Joe White was present representing the request. There were no registered objectors present. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented a recommendation of approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff also presented a recommendation of approval of the requested variance to allow the creation of a lot without public street frontage for proposed Lot 4. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 3 FILE NO.: S-185-P NAME: Little Rock Port Subdivision Tract C Area 101 Revised Preliminary Plat LOCATION: North of Slone Drive, South of Lindsey Road DEVELOPER: Fleming Building Company of Arkansas 1001 West Fort Gibson Road Catoosa, OK 74015 ENGINEER: Garver Engineers, LLC 1010 Battery Street Little Rock, AR 72202 AREA: 59.43 acres NUMBER OF LOTS: 6 FT. NEW STREET: 1824 L.F. CURRENT ZONING: I-3, Industrial District PLANNING DISTRICT: 25 CENSUS TRACT: 40.07 VARIANCES/WAIVERS REQUESTED: A variance to allow a reduced front yard building line. A. PROPOSAL/REQUEST: Tract C was platted in 1974 and consists of approximately 60 acres. A 550,000 square foot warehouse with related rail and truck facilities was constructed by GE and has been utilized for 30 years. The Kansas City Life Insurance Company purchased Tract C and Applica presently utilizes the existing warehouse space. The old GE building is proposed to be included in a single lot (Lot C1) and the area south of Lot C1 is proposed as Lot C2. Lots C3 – C6 are located along the east edge of the property and will be used for four proposed warehouse buildings. The applicant has indicated a new industrial street (Trout Road) will be added to serve the four easterly lots from the west side. The applicant is requesting two phases; the development of Lots C3 and C6 in the first phase with Lots C4 and C5 developed in the second phase. The roadway and drainage improvements will be constructed in the first phase. March 11, 2004 SUBDIVISION ITEM NO.: 3 (Cont.) FILE NO.: S-185-P 2 B. EXISTING CONDITIONS: The site is located in the Port of Little Rock where there are numerous industrial buildings and activities. The site contains a large industrial building currently occupied by Applica. There is a large vacant grass covered area on the east and southern portion of the lot. There is a rail spur located along the eastern boundary of the property. Other uses in the area include industrial uses on I-3 zoned properties. Adjacent to the site, Lindsey Road and Sloane Drive are constructed to industrial road standards per the Master Street Plan. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. All abutting property owners and the College Station Progressive League were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Trout Road is to be constructed to the industrial street standards of the Master Street Plan and dedicated as a public street. 2. The ends of new Trout Road must be designed to facilitate truck-turning movements without crossing into the opposing lane. A larger radius with a throat width of 50 feet with a 160-foot taper is suggested. 3. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Site grading, and drainage plans will need to be submitted and approved prior to the start of construction. 4. Street improvement plans shall include signage and striping. Traffic Engineering must approve completed plans prior to construction. 5. Prepare a letter of pending development addressing streetlights as required by Section 31-403 of the Little Rock code. Contact Traffic Engineering at (501) 379-1813 (Steve Philpott) for more information regarding street light requirements. 6. Driveway locations and widths are acceptable under the traffic access and circulation requirements of Sections 30-43 and 31-210. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer main extension required, with easements, if service is March 11, 2004 SUBDIVISION ITEM NO.: 3 (Cont.) FILE NO.: S-185-P 3 required for the project. Contact Little Rock Wastewater Utility at 688-1414 for additional details. Entergy: No comment received. Center-Point Energy: Approved as submitted. SBC: Approved as submitted. Central Arkansas Water: A water main extension will be required. A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all meter connections including any metered connections off a private fire system. All Central Arkansas Water requirements in effect at the time of request for water service must be met. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional details. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) The applicant was present representing the request. Staff presented an overview of the proposed request indicating there were additional items necessary to complete the review. Staff requested the applicant provide the linear feet of internal street in the general notes section of the proposed preliminary plat. Staff also requested the applicant provide the names of recorded subdivisions abutting the plat area. Staff requested the applicant provide the source of water and the means of wastewater disposal in the general notes section of the preliminary plat. Public Works comments were addressed. Staff stated the ends of new Trout Road must be designed to facilitate truck-turning movements without crossing March 11, 2004 SUBDIVISION ITEM NO.: 3 (Cont.) FILE NO.: S-185-P 4 into the opposing lane. Staff stated the driveway locations and widths were acceptable under the traffic access and circulation requirements of Sections 30-43 and 31-210. Staff noted comments from other reporting departments and utilities. Staff suggested the applicant contact them individually for additional information. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plan to staff addressing the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated the source of water as Central Arkansas Water and the means of wastewater disposal as Little Rock Wastewater Utility. The applicant has also indicated the names of recorded subdivisions abutting the plat area. The proposed preliminary plat indicates the addition of 1824 linear feet of new street as a result of the plat. The applicant has satisfied Public Works with regard to street design and driveway locations. The applicant has indicated new Trout Road designed to facilitate truck-turning movements without crossing into the opposing lane. The applicant is requesting a variance to allow a reduced front yard building line. The applicant has indicated a thirty-nine foot building line adjacent to proposed Trout Road. The ordinance typically requires a fifty-foot front yard building line adjacent to the street. Staff is supportive of this request. The proposed development will internalize parking between the warehouse buildings. The new road will be constructed to industrial street standards and the reduced building line should have minimal to no adverse impact on the adjoining properties. Staff is supportive of the proposed request. The applicant has indicated the development of 59.43 acres into six (6) industrial lots. The lots are currently zoned I-3 which requires a minimum lot size of one (1) acre. The proposed lots are more than adequate to meet this requirement; ranging in size from 3.02 acres to 27.38 acres. To staff’s knowledge there are no outstanding issues associated with the proposed request. Staff feels if the proposed preliminary plat is approved as presented there should be minimal to no adverse impact on adjoining properties. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. March 11, 2004 SUBDIVISION ITEM NO.: 3 (Cont.) FILE NO.: S-185-P 5 Staff recommends approval of the requested variance to allow a reduced front yard building line, adjacent to Trout Road. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were no registered objectors present. Staff presented the item indicating the applicant had submitted a letter dated March 8, 2004 requesting the item be deferred to the April 22, 2004 Planning Commission Public Hearing. Staff stated the deferral would require a waiver of the By-Laws related to the late deferral request. Staff stated they were supportive of the By-law waiver and the deferral request. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 4 FILE NO.: S-686-D NAME: River Ridge Pointe Subdivision Lot 2 Replat LOCATION: On River Ridge Pointe DEVELOPER: Marlow Morgan 2200 Riverfront Drive #7201 Little Rock, AR 72201 ENGINEER: Ollen Dee Wilson 2523 North Willow Street North Little Rock, AR 72114 AREA: 5.0 acres NUMBER OF LOTS: 2 FT. NEW STREET: 0 CURRENT ZONING: R-2, Single-family PLANNING DISTRICT: 3 CENSUS TRACT: 22.01 VARIANCES/WAIVERS REQUESTED: 1. A variance to allow the creation of two pipe stem lots. 2. A variance to allow a reduced lot width of the pipe stem and a variance to allow an increased depth of the pipe stem. BACKGROUND: The Little Rock Planning Commission approved a preliminary plat for a site containing 64.3 acres and forty-four lots at their July 8, 1986, Public Hearing. The final plat for the area was reviewed and executed in September of 1987. The proposed site contained a single pipe stem lot with a fifty-foot width at the street and four hundred eighty-five feet of depth. The applicant proposed a twenty-foot access drive. The overall lot dimension outside the pipe stem averaged four hundred feet by nine hundred feet. The total lot contained five acres. March 11, 2004 SUBDIVISION ITEM NO.: 4 (Cont.) FILE NO.: S-686-D 2 A. PROPOSAL/REQUEST: The applicant is now proposing to split the previously final platted five acre lot. The proposed lot split will contain two pipe stem lots with a reduced lot width for a pipe stem and an increased depth of the pipe stem. Each lot stem will be approximately twenty-five feet. The applicant is proposing the placement of a single eighteen-foot access drive to serve the two lots. Each lot will contain approximately two and one-half acres. The applicant has indicated buildable areas on the proposed plat. B. EXISTING CONDITIONS: The site is vacant and tree covered. The terrain is very steep falling to the center of the proposed plat area and rising rapidly to the west of the site. There are easements located within the proposed plat area for both water and wastewater. The area is developed with single-family homes on large lots. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. All abutting property owners and the River Ridge Property Owners Association were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. No city services will be provided on the private access easement. Per current alley standards, 18-foot minimum pavement width is to be provided. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer main extension required, with easements, if service is required for the project. Contact Little Rock Wastewater at 688-1414 for additional details. Entergy: No comment received. Center-Point Energy: Approved as submitted. SBC: No comment received. March 11, 2004 SUBDIVISION ITEM NO.: 4 (Cont.) FILE NO.: S-686-D 3 Central Arkansas Water: Show existing platted utility easement. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. All Central Arkansas Water requirements in effect at the time of request for water service must be met. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Approved as submitted. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) The applicant was present representing the request. Staff briefly described the proposed development indicating there were additional items necessary to complete the review process. Staff requested the applicant provide the proposed source of water, means of wastewater disposal and the certificates of platting on the proposed plat. Staff also requested the applicant provide contours and the proposed buildable areas. Staff stated the site was very steep and questioned the buildability of the lots. Mr. Dee Wilson, representing the applicant, questioned the requirement of the minimum driveway width and the required location of the drive. Staff stated the fire department required a minimum of eighteen feet of paved surface and the drive would need to be extended to the property line of Lot 2B. Staff also noted the applicant would be required to contact the Little Rock Fire Department and receive written verification of the need for additional fire hydrants. Staff stated Central Arkansas Water had requested the written verification to assure adequate fire protection was in place. There was no additional discussion of the item. The Committee then forwarded the item to the full Commission for final action. March 11, 2004 SUBDIVISION ITEM NO.: 4 (Cont.) FILE NO.: S-686-D 4 H. ANALYSIS: The applicant submitted a revised plat to staff, as requested at the February 19, 2004 Subdivision Committee meeting, indicating the source of water, means of wastewater disposal and the certificates of platting. The applicant has indicated Central Arkansas Water as the source of water and the Little Rock Wastewater Utility as the means of wastewater disposal for the proposed development. The applicant has also indicated contours on the proposed plat along with the proposed buildable areas. The site has a valley running through the middle of the proposed plat area, limiting the buildable area of the lots. Even though the site has constraints due to elevation changes it appears there is sufficient area for construction of the new homes on the proposed lots. The applicant has also indicated an eighteen foot paved driveway extending from River Ridge Pointe to proposed Lot 2B. The drive will be a shared drive and is to be constructed within the fifty-foot area (twenty-five feet each) of the pipe stems proposed for the lots. The proposed pipe stems are labeled as an access and utility easement to allow services to each of the lots. The applicant has indicated the Fire Department is evaluating the site to determine if additional fire hydrants are needed to serve the proposed development. If additional fire hydrants are necessary they will be secured at the time of final platting. The proposed plat requires two variances from the Subdivision Ordinance. The plat contains a variance to allow the creation of a pipe stem lot and a variance from the minimum width of the pipe stem and the maximum depth of the pipe stem. Staff is supportive of the proposed requested variances. An eighteen-foot driveway will serve the proposed lots adequate; to meet the minimum alley widths per current city code. The lot area appears to be more than adequate to meet all required setbacks and have sufficient area for development. The previous plat included the development of the lot as a pipe-stem with a fifty-foot stem at the street and a twenty-foot access drive. Staff does not feel the replatting of the lot into two individual lots will have any adverse impact on the surrounding area. To Staff’s knowledge there are no outstanding issues associated with the proposed request. Staff recommends approval of the request to replat Lot 2 of the River Ridge Pointe Addition into Lots 2A and 2B and the associated variances. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the requirements outlined in paragraphs D, E and F of the above report. March 11, 2004 SUBDIVISION ITEM NO.: 4 (Cont.) FILE NO.: S-686-D 5 Staff recommends approval of the requested variance to allow the creation of pipe stem lots for Lots 2A and 2B. Staff recommends approval of the requested variance to allow a reduced width of the pipe stem for Lots 2A and 2B of the River Ridge Pointe Addition. Staff recommends approval of the requested variance to allow an increased depth of the pipe stem for Lots 2A and 2B of the River Ridge Pointe Addition. Staff recommends all issues related to the placement of fire hydrants be resolved prior to final platting. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were no registered objectors present. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented the item with a recommendation of approval of the request subject to compliance with the requirements outlined in paragraphs D, E and F of the above report. Staff presented recommendations of approval of the requested variance to allow the creation of pipe stem lots for Lots 2A and 2B of the River Ridge Pointe Addition, the requested variance to allow a reduced width of the pipe stem for Lots 2A and 2B of the River Ridge Pointe Addition and the requested variance to allow an increased depth of the pipe stem for Lots 2A and 2B of the River Ridge Pointe Addition. Staff also presented a recommendation that all issues related to the placement of fire hydrants be resolved prior to final platting. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 5 FILE NO.: S-867-EEEEE NAME: Chenal Valley Phase 2 Commercial Subdivision Revised Preliminary Plat LOCATION: On the Southeast Corner of Cantrell Road and Chenal Parkway DEVELOPER: Wal-Mart Store, Incorporated 702 S.W. 8th Street Bentonville, AR 72716-0550 ENGINEER: Carlson Consulting Engineers 7731 Highway 70, Suite 210 Bartlett, TN 38133 AREA: 28.63 acres NUMBER OF LOTS: 4 FT. NEW STREET: 0 CURRENT ZONING: C-3, With Conditions – General Commercial District with a site plan review PLANNING DISTRICT: 19 - Chenal CENSUS TRACT: 42.11 VARIANCES/WAIVERS REQUESTED: None requested. BACKGROUND: Chenal Valley Phase II Commercial – Preliminary Plat was reviewed and approved by the Little Rock Planning Commission on October 15, 1998. The original submission contained approximately 53.3 acres and included twenty lots of various zoning classifications. The applicant amended his request to be eight (8) lots and to only include the land area located on the southeast corner of Cantrell Road and Chenal Parkway, a large potion of the area currently under review. A final plat was executed for Lot 1 of the proposed preliminary plat area. Lot 1 contains 2.2 acres and was filed with the Pulaski County Clerk on December 31, 1998 (Plat Book F Page 412). March 11, 2004 SUBDIVISION ITEM NO.: 5 (Cont.) FILE NO.: S-867-EEEEE 2 A. PROPOSAL/REQUEST: The applicant proposes to revise the previously approved preliminary plat to include the development of four lots. The proposal includes Lots 2, 3 and 4 (Lot 1 was previously final platted). The lots range in size from 1.05 acres to 26.16 acres more or less. The new Wal-Mart Super center will be located on Lot 2. The applicant has indicated all required street improvements will be constructed in conjunction with the construction of the Wal-Mart Super center currently under construction. The applicant has also indicated no new drives from Cantrell Road or Chenal Parkway are proposed. The drives will remain as was previously approved by the Planning Commission at their October 31, 2001 Public Hearing related to the Wal-Mart Super center site plan review. B. EXISTING CONDITIONS: The site has been cleared for construction of the Wal-Mart Super Center. Chenal Parkway, in this area, is a two-lane road and Cantrell Road is a four-lane road with a center turn lane at the intersection of Chenal Parkway and Cantrell Road. Other uses in the area include a Quick Stop Service Station on the northwest corner and mini-warehouses on the northeast corner of Chenal Parkway and Cantrell Road. The southwest corner is zoned C-3, General Commercial and is currently undeveloped. There is an Entergy easement along the east property line with a church located further to the east of the site. Vacant O-2 zoned property is located to the south of the site with OS zoned property located between the office zoning and the single-family residential located further south and east of the proposed development. South and west of the proposed development are also single-family residences adjoining vacant O-2 and C-2 zoned property. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. All abutting property owners and the Aberdeen Court Property Owners Association, the Bayonne Place Property Owners Association, the Margeaux Property Owners Association and the DuQuesne Place Property Owners Association were notified of the public hearing. March 11, 2004 SUBDIVISION ITEM NO.: 5 (Cont.) FILE NO.: S-867-EEEEE 3 D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. No Comment. It appears there are no revisions to the approved right-of-way lines, curb cuts, or access easements as previously approved. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available not adversely affected. Contact Little Rock Wastewater Utility at 688-1414 for additional information. Entergy: Approved as submitted. Center-Point Energy: Approved as submitted. SBC: No comment received. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. The existing 15-foot-wide waterline easement (recorded as instrument no. 98-021076) should be shown. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Approved as submitted. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Mike Dedman was present representing the request. Staff gave an overview of the proposed development indicating to Mr. Dedman there were questions concerning the proposed preliminary plat. Staff questioned the grading easement located to the south. Mr. Dedman stated this was a previous March 11, 2004 SUBDIVISION ITEM NO.: 5 (Cont.) FILE NO.: S-867-EEEEE 4 agreement with Chenal Properties, which was abandoned when the city did not agree to allow off-site grading. Staff recommended the easement be removed. Staff also questioned if there was to be a phasing plan. Mr. Dedman stated the lots would be final platted all at one time. Staff requested the certificates of preliminary platting be included on the proposed preliminary plat. Mr. Dedman stated this issue would be corrected. The proposed revision to the Wal-Mart site was discussed with the proposed preliminary plat. Staff noted there were few outstanding issues related to this item and requested notification of property owners as required by the Planning Commission By-Laws. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised preliminary plat to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has removed the grading easement located to the south of the property and has included the certificates of preliminary platting. The applicant has also indicated lots will be developed in one phase. Staff is supportive of the proposed request. The proposed lot sizes meet the minimum requirements of the Subdivision Ordinances and the applicant has indicated the required setbacks per the zoning ordinance. The preliminary plat was approved for eight (8) lots. Staff feels the reduced number of lots will not have any adverse impact on the adjoining properties. In addition, most of the proposed plat area falls within the area zoned C-3, with conditions, which requires a site plan review of the proposed development prior to receiving a building permit. Proposed Lot 4 is a separate item on this agenda (Item No. 17 – File No. Z-5097- F); a request for a site plan review for a Murphy Oil Fueling Station. The applicant will be required to submit for a site plan review prior to the development of proposed Lot 3 if the condition of site plan review remains on the zoning as it currently exist. To staff’s knowledge there are no outstanding issues associated with the proposed request. The proposed lots meet with minimum requirements with regard to minimum lot size, front yard building line and minimum lot widths. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. March 11, 2004 SUBDIVISION ITEM NO.: 5 (Cont.) FILE NO.: S-867-EEEEE 5 PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were no registered objectors present. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented the item with a recommendation of approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 6 FILE NO.: S-1310-B NAME: Cantrell Loops Subdivision revised Preliminary Plat LOCATION: North of Cantrell Road at Taylor Loop Road DEVELOPER: Grayson Revocable Trust 5317 JFK Boulevard North Little Rock, AR 72116 ENGINEER: The Mehlburger Firm 201 South Izard Street Little Rock, AR 72201 AREA: 4.265 Acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 CURRENT ZONING: C-3 – General Commercial District and R-2 – Single-family PLANNING DISTRICT: 20 CENSUS TRACT: 42.05 VARIANCES/WAIVERS REQUESTED: A variance to allow the creation of a lot without public street frontage. BACKGROUND: The Little Rock Planning Commission reviewed and approved a preliminary plat for the Cantrell Loops Subdivision on May 31, 2001. The proposal included the subdivision of 6.54 acres along the north side of Cantrell Road (at the east leg of Taylor Loop Road) into two (2) lots for commercial development. The property was zoned R-2 and C-3. The applicant indicated a 60-foot access easement between Lots 1 and 2 as the primary access to the two-lot development. A second drive was proposed approximately 300 feet to the west along the frontage of Lot 1. The plat indicated a 100-foot front yard building line as required by the Highway 10 Design Overlay District Ordinance. A rezoning request for Lot 1 was also approved as a separate item on the agenda to rezone the site to Planned Commercial Development to allow for the construction of a Walgreen’s store. March 11, 2004 SUBDIVISION ITEM NO.: 6 (Cont.) FILE NO.: S-1310-B 2 Lot 1 was final platted as a part of the Walgreen’s development. Lot 2 has not been final platted. The applicant submitted a proposed Planned Commercial Development for Lot 2 of the site to be considered by the Planning Commission at their January 29, 2004 Public Hearing (Item No. E.1 – File No. Z-7022-A). Prior to the Commission meeting the applicant requested the item be deferred to the March 11, 2004 Public Hearing to allow time for submission of the currently requested preliminary plat. The applicant submitted a request on February 26, 2004, for the item to be amended to include the site plan of proposed Lot 2. A. PROPOSAL/REQUEST: The applicant proposes to revise a previously approved preliminary plat to allow a three (3) lot plat. Lot 1 was previously final platted and the applicant is proposing a further division of proposed Lot 2 into Lots 2 and 3. Proposed Lot 2 will require a variance from the Subdivision Ordinance to allow the creation of a lot without public street frontage. Proposed Lot 2 is currently zoned R-2, Single-family. The applicant has submitted a request to amend a previously filed PCD application to only include the development plan for proposed Lot 2 (Item No. E.1 – File No. Z-7022-A). The proposed preliminary plat indicates a 60-foot access easement to serve Lot 2. Proposed Lot 3 is currently zoned C-3, General Commercial District. The applicant has indicated the lot will be developed per the existing zoning. B. EXISTING CONDITIONS: The site is mostly wooded along the northern perimeter and vacant grass covered along Cantrell Road. There is a Walgreen’s Store located on Lot 1 of the development and the driveway to serve the development and a traffic signal has been installed at the intersection with Cantrell Road and Taylor Loop Road. There is a commercial development located to the east, with both occupied and vacant single-family residences to the west. There are commercial uses at the southwest corner of Cantrell Road and Taylor Loop Road, with a vacant single- family residence at the southeast corner. The property to the north is undeveloped and zoned R-2, Single-family District. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents concerning the proposed preliminary plat. All property owners located within 200-feet of the proposed development, all residents who could be identified March 11, 2004 SUBDIVISION ITEM NO.: 6 (Cont.) FILE NO.: S-1310-B 3 located within 300-feet of the proposed development, the Westchester/Heatherbrae, the Secluded Hills, the Westbury and the Charleston Height/North Rahling Road Neighborhood Associations were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Site grading, and drainage plans will need to be submitted and approved prior to the start of construction. 2. Storm water detention ordinance applies to this property. Show the proposed location for storm water detention facilities on the plan. 3. On site striping and signage plans should be forwarded to Public Works, Traffic Engineering for approval with the site development package. One-way traffic should be provided in the aisle areas near the drive through windows. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Entergy: No comment received. Center-Point Energy: Approved as submitted. SBC: No comment received. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. Contact Central Arkansas Water regarding the size and location of the water meter(s). A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all meter connections. Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Each parcel that does not have access to adequate public fire hydrants must have at least one private fire hydrant. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact Central Arkansas Water at 992-2438 for additional information. March 11, 2004 SUBDIVISION ITEM NO.: 6 (Cont.) FILE NO.: S-1310-B 4 Fire Department: Approved as submitted. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Frank Riggins was present representing the request. Staff gave an overview of the proposed request stating there were additional items necessary to compete the final review. Staff requested the applicant provide the front yard building line, the certificates of preliminary platting, the names of owners of all abutting lands, a metes and bounds legal description and the limits of the floodway/floodplain on the proposed preliminary plat. Staff also requested the applicant provide the proposed source of water and the means of wastewater disposal in the general notes section of the proposed preliminary plat. Public Works comments were addressed. Staff stated a grading permit in accordance with Section 29-186 (c) and (d) would be required prior to any land clearing or grading activities. Staff also stated the storm water detention ordinance would apply to the property. Staff reaffirmed comments from the item deferred from the January 29, 2004 Public Hearing concerning the potential development of a strip retail center located on proposed Lot 2. Staff stated the drive-through window was not acceptable since the location would cause conflicting traffic movements. Staff also questioned the treatment of the rear of the structure and the proposed openings. Staff stated the proposed access easement should not extend to the northern property line. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised preliminary plat to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated the front yard building line, the certificates of preliminary platting, the names of owners of all abutting lands and a metes and bounds legal March 11, 2004 SUBDIVISION ITEM NO.: 6 (Cont.) FILE NO.: S-1310-B 5 description of the proposed preliminary plat area. The applicant has also indicated no portion of the proposed plat area lies within the floodplain or floodway. The applicant has indicated the source of water as Central Arkansas Water and the means of wastewater disposal as Little Rock Wastewater Utility. The applicant has indicated the creation of a lot without public street frontage, which requires a variance from the Subdivision Ordinance. Staff is supportive of the requested variance. The development will be served by a sixty-foot access and utility easement with a cross access and parking easement to be filed between the three lots. The applicant has indicated a sign easement on proposed Lot 3 for proposed Lot 2 to allow signage along Cantrell Road. The sign will be a shared sign between the two developments consistent with Highway 10 Design Overlay District requirements, or a single ground mounted monument style sign, a maximum of ten feet in height and seventy-two square feet in area. The applicant has revised the proposed site plan for Lot 2 of the development, the previously deferred PCD (Item #E.1 – File No. Z-7022-A). The applicant has indicated the drive-through lane as a one-way traffic lane and striped parking to indicate such. The applicant has also indicated the rears of buildings will act as screening and no doors or windows will be place on the rear of the building other than those required by fire code. The applicant has indicated mechanical equipment will be placed in an area that will not be intrusive to the adjoining single-family zoned properties. The applicant has indicated the west and north property lines will be screened by a six foot wood fence with additional plantings of evergreens to further screen the site from adjoining properties. Staff is supportive of the proposed screening. Staff is supportive of the proposed preliminary plat and the proposed site plan for the revised planned development. Staff feels the proposed development should have minimal to no adverse impact if developed as proposed. The applicant has indicated required screening to shield the single-family zoned properties located to the west and north of the site. To staff’s knowledge there are no outstanding issues associated with the proposed request. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff recommends approval of the requested variance from the Subdivision Ordinance to allow the creation of a lot without public street frontage. March 11, 2004 SUBDIVISION ITEM NO.: 6 (Cont.) FILE NO.: S-1310-B 6 PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Frank Riggins was present representing the request. Staff presented the item and indicated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented a recommendation of approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff presented a recommendation of approval of the requested variance from the Subdivision Ordinance to allow the creation of a lot without public street frontage. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 7 FILE NO.: S-1409-A NAME: Madison Valley Subdivision Revised Preliminary Plat LOCATION: South of Taylor Loop Road on Montgomery Road DEVELOPER: Card Investment, LLC 12418 Cantrell Road Little Rock, AR 72223 ENGINEER: McGetrick and McGetrick Engineers 319 President Clinton Avenue, Suite 202 Little Rock, AR 72201 AREA: 24.59 acres NUMBER OF LOTS: 83 FT. NEW STREET: 2,850 LF CURRENT ZONING: R-2, Single-family PLANNING DISTRICT: 19 - Chenal CENSUS TRACT: 42.11 VARIANCES/WAIVERS REQUESTED: 1. A variance to allow double frontage lots. 2. A variance to allow an increased lot depth to width ratio for selected lots. 3. A variance to allow a reduced front yard building line for selected lots. BACKGROUND: The Little Rock Planning Commission reviewed and approved this site for a preliminary plat at their December 4, 2003 Public Hearing. The applicant proposed the subdivision of 19.2 acres into 75 single-family lots. The applicant indicated the average lot size to be 65-feet by 110-feet or 7,150 square feet. The proposed development was to add 2,850 linear feet of new street to the City. The development included ½ street construction to Montgomery Road adjacent to the site and the construction of three new residential streets. The applicant requested a portion of Montgomery Road right-of-way be abandoned. The area to the south is owned by Chenal Properties and their preliminary design of a proposed development did not indicate access to Montgomery Road. The applicant March 11, 2004 SUBDIVISION ITEM NO.: 7 (Cont.) FILE NO.: S-1409-A 2 indicated a right-of-way abandonment would be secured prior to development of the proposed lots affected by the right-of-way. A. PROPOSAL/REQUEST: The applicant is proposing a revision to the previously approved preliminary plat. The proposed revised preliminary plat includes the subdivision of 24.59 acres into 83 single-family lots. The proposed revision includes the addition of land to the development and increasing the overall average lot size within the development. The applicant is proposing three variances related to the Subdivision Ordinance. The applicant is requesting a variance to allow the creation of double frontage lots, a variance to allow a reduced front building line and a variance to allow an increased lot depth to width ratio for selected corner lots. The applicant has indicated the proposed subdivision will be constructed in two (2) phases. B. EXISTING CONDITIONS: The developer has begun construction of the previously approved preliminary plat, clearing and grading the site in preparation of installation of the basic infrastructure. The area contains a scattering of homes along Montgomery Road on acreage along the east side of the road. Pennwyck Subdivision is also located across Montgomery Road to the east. The Baptist Church property is located east of the site with the church owning most of the land adjoining the eastern boundary of the plat. The area to the west contains homes located on five plus acre tracts accessed by Carter Lane. To the north of the site along Taylor Loop Road is the Montessori School campus. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has received several informational phone calls from area residents concerning the proposed development. The Westchester/Heatherbrae Neighborhood Association and the Charleston Heights/North Rahling Road Neighborhood Association and all abutting property owners were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Taylor Loop is classified on the Master Street Plan as a collector street. Dedicate right-of-way to 30 feet from centerline and construct 1/2 of a 36 foot Street. Sidewalks are required. March 11, 2004 SUBDIVISION ITEM NO.: 7 (Cont.) FILE NO.: S-1409-A 3 2. Larger drainage piping and additional easements may be required to handle the anticipated up-stream flow to the site. Contact Public Works, David Hamilton, at 244-5402. 3. Provide calculations indicating the preliminary sizing of the detention basin. The basin should be built as part of the initial phase of the development. Easements for the inlet and outlet of the storm water detention facilities are required. 4. Holland Lane does not meet design standards for curvature and tangent distance between reverse curves. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer main extension required, with easements, if service is required for the project. Contact Little Rock Wastewater Utility at 688-1414 for additional details. Entergy: No comment received. Center-Point Energy: Approved as submitted. SBC: Approved as submitted. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. A water main extension will be required in order to provide service to this property. A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional details. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. March 11, 2004 SUBDIVISION ITEM NO.: 7 (Cont.) FILE NO.: S-1409-A 4 G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Pat McGetrick was present representing the request. Staff presented an overview indicating the requested revision was to add additional acreage to the previously approved preliminary plat. Staff requested additional information be included on the proposed preliminary plat including the name/address and source of title of the landowner. Staff also requested the applicant provide a phasing plan, if applicable. Public Works comments were addressed. Staff stated Taylor Loop Road was classified on the Master Street Plan as a minor arterial and one-half street construction would be required. Staff also stated sidewalks would be required. Staff stated proposed Holland Lane did not meet current design standards for curvature and tangent distance between reverse curves. Staff stated there were concerns with the total volumes of water. Mr. McGetrick stated the topography split at Gooch Drive. Staff recommended Mr. McGetrick meet with staff to ensure the proposed detention was adequate. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised preliminary plat to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated the name/address and source of title of the landowner. The applicant has also provided a phasing plan for the proposed development. The applicant has indicated the development will be constructed in two phases with the first phase containing the proposed detention and Lots 7 – 83. The second phase (Lots 1 – 6) will be constructed in the future. The applicant has indicated a 20-foot easement along the lot lines of proposed Lots 79 and 80 to allow sewer to be extended to the property located to the east. The applicant has also indicated the extension of public right-of-way to the north of Gavin Court to allow access to the site as well. The proposed easements and right-of-way will allow the eastern property owner access to city services and public streets should they decide at some point in the future to further subdivide their property. The applicant has revised the preliminary plat to address Public Works concerns related to Holland Lane. The applicant has shortened the proposed street length and added a cul-de-sac to the north. The applicant has also increased the proposed detention area to 20,000 square feet. March 11, 2004 SUBDIVISION ITEM NO.: 7 (Cont.) FILE NO.: S-1409-A 5 The applicant is requesting a reduced front building line for several of the proposed lots. The applicant has indicated a fifteen-foot front building line for Lots 2 – 44, 47 – 53, 72 – 77 and 82 – 83. The applicant has indicated with the development being developed with a neighborhood feel and all streets internal to the development, a reduced platted building line will act as a traffic calming device. Staff is supportive of the proposed request. The applicant is requesting a variance to allow an increased lot depth to width ratio for Lots 45, 46, 70, 79 and 80. The Subdivision Ordinance requires no lot be more than three times as deep as it is wide. On these lots, all corner lots, the applicant has not met this requirement and is requesting a variance to allow the proposed lot design. Staff is supportive of this request. The applicant has indicated two of the lots as double frontage lots. The proposed lots (Lots 5 and 6) will front on Montgomery Road and also abut Holland Lane. The lots will be accessed from Montgomery Road and a ten-foot no vehicular access easement will be placed along Holland Lane. Staff is supportive of the requested variance to allow the creation of these double frontage lots. Staff is supportive of the proposed preliminary plat. The applicant is proposing the development of 24.59 acres into 83 single-family residential lots resulting in a proposed density of 3.37 units per acre. The proposed development includes concession to allow the proposed property located to the east to redevelop at some point in the future should the owner elect to subdivide their existing parcel. To staff’s knowledge there are no outstanding issues associated with the proposed request. Staff recommends approval of the requested preliminary plat and the associated variances. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff recommends approval of the requested variance to allow the creation of double frontage lots for Lots 5 and 6. Staff recommends approval of the requested variance to allow an increased lot depth to width ratio for Lots 45, 46, 71, 79 and 80. Staff recommends approval of the requested variance to allow a reduced front yard building line for Lots 2 – 44, 47 – 53, 72 – 77 and 82 - 83. March 11, 2004 SUBDIVISION ITEM NO.: 7 (Cont.) FILE NO.: S-1409-A 6 PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Pat McGetrick was present representing the request. There were no registered objectors present. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented a recommendation of approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff also presented recommendations of approval of the requested variance to allow the creation of double frontage lots for Lots 5 and 6, the requested variance to allow an increased lot depth to width ratio for Lots 45, 46, 71, 79 and 80 and the requested variance to allow a reduced front yard building line for Lots 2 – 44, 47 – 53, 72 – 77 and 82 - 83. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 I T E M N O . : 8 F I L E N O . : S - 1 4 1 7 NAME: Amy Ridge Subdivision Preliminary Plat LOCATION: On the Southwest corner of Labette Drive and John Barrow Road DEVELOPER: Angelcity Development Corporation P.O. Box 10745 Jackson, TN 38308 ENGINEER: McGetrick and McGetrick Engineers 319 President Clinton Avenue, Suite 202 Little Rock, AR 72201 AREA: 6.75 acres NUMBER OF LOTS: 28 FT. NEW STREET: 1540 L.F. CURRENT ZONING: MF-18, Multi-family 18-Units per acre PLANNING DISTRICT: 11 CENSUS TRACT: 24.04 VARIANCES/WAIVERS REQUESTED: A variance to allow an increased lot depth to width ratio for Lots 22 and 23. BACKGROUND: A 10 acre site containing seven lots known as Barrow Plaza Addition was reviewed and approved for a preliminary plat by the Little Rock Planning Commission at their August 12, 1986 Public Hearing. Lots 1 and 2 have been final platted. The applicant has indicated the roadway was also dedicated through a metes and bounds legal description. A. PROPOSAL/REQUEST: The applicant is proposing the subdivision of this 6.75-acre parcel into 28 single- family lots. The lots will be served by the addition of 1,540 linear feet of new street. The applicant has indicated the average lot size will be 70 feet by 100 feet or 7,000 square feet. March 11, 2004 SUBDIVISION ITEM NO.: 8 (Cont.) FILE NO.: S-1417 2 Proposed Lots 22 and 23 will require a variance from the Subdivision Ordinance to allow an increased depth to width ratio. The site is currently zoned MF-18 which does not allow for single-family development. The applicant has indicated should the preliminary plat be approved the applicant will request to rezone the site to R-2, Single-family. B. EXISTING CONDITIONS: The site is tree covered, sloping upward to the southwest. There are multi-family units located to the west of the site accessed from Labette Manor Drive. There is a nursing home located to the north of the site adjacent to John Barrow Road. A POD is located on the corner of Labette and John Barrow Road currently housing medical equipment sales and service with a new building constructed south of the POD (currently zoned O-3) for an automobile customizing business. Also south of the site is an approved POD, the site of the new Central Arkansas Library, which is currently under construction. Labette Drive dead-ends into the site. The street has been constructed with curb and gutter adjacent to Lots 1 and 2, which were previously final platted. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. All abutting property owners and the John Barrow Neighborhood Association, the Twin Lakes “B” Property Owners Association, the Campus Place Neighborhood Association and the Twin Lakes B Special Improvement District were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. A small stub street is proposed to serve Lots 2 through 8. A tee type turn around should be provided at the southern end of the stub street. Labette Drive extension should be moved eastward to align with this stub. 2. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Site grading, and drainage plans will need to be submitted and approved prior to the start of construction. 3. Storm water detention ordinance applies to this property. Show the proposed location for storm water detention facilities on the plan. March 11, 2004 SUBDIVISION ITEM NO.: 8 (Cont.) FILE NO.: S-1417 3 4. Provide the direction of flow and all storm water flows (Q) entering and leaving the property. Easements are required for all storm drainage areas. 5. Prepare a letter of pending development addressing streetlights as required by Section 31-403 of the Little Rock code. Contact Traffic Engineering at (501) 379-1813 (Steve Philpott) for more information regarding street light requirements. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: A sewer main crosses the property. No construction within the easement unless sewer main is relocated. A sewer main extension is required with easements for the remainder of the development. Contact Little Rock Wastewater Utility at 688-1414 for additional information. Entergy: No comment received. Center-Point Energy: Approved as submitted. SBC: No comment received. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. An existing 12-inch diameter water main will have to be relocated to align with street rights-of-way or the streets will have to be aligned to the water main at its existing location. A Capital Investment Charge based on the size of connection(s) will apply to this project in addition to normal charges. A water main extension will be required in order to provide service to this property. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional details. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. March 11, 2004 SUBDIVISION ITEM NO.: 8 (Cont.) FILE NO.: S-1417 4 G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Pat McGetrick was present representing the request. Staff stated the site was currently zoned MF-18 which did not allow for the development of single- family residential. Staff stated if the proposed preliminary plat was approved, the applicant would be required to rezone the site to R-2 prior to development. Staff questioned the proposed location of Labette Drive. Staff stated there were currently water and sewer lines following a previous proposed alignment of Labette Drive and suggested Mr. McGetrick realign the street to follow the previous alignment. Mr. McGetrick stated the street had been dedicated through a metes and bounds description. Mr. McGetrick stated he would relocate the water and the lots would be platted around the existing sewer easement. Staff requested the short stub street proposed be removed and end in a cul-de- sac or a “T” turnaround. Staff also questioned the placement of the intersection of Labette Drive and the existing stubbed Labette Drive. Staff stated this proposed design appeared to cause sight distance problems at the intersection. Staff suggested Mr. McGetrick redesign the proposed intersection. Additional Public Works comments were addressed. Staff stated prior to development, a grading permit would be required and the storm water detention ordinance would apply to the development. Staff requested the applicant provide a preliminary storm water analysis for the proposed plat area. There were no additional items for discussion. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised preliminary plat to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated the location of Labette Drive was established by dedication of the right-of-way through a metes and bounds legal description. The applicant has also indicated the existing water and sewer lines and located lot lines along the existing easements. The revised preliminary plat indicates the short stub street as a cul-de-sac as requested by staff. The applicant has also indicated the intersection of Labette Drive with the existing stubbed Labette Drive more perpendicular thus minimizing sight distance problems. The proposed preliminary plat has indicated a variance from the Subdivision Ordinance to allow two of the lots to develop with an increased lot depth to width March 11, 2004 SUBDIVISION ITEM NO.: 8 (Cont.) FILE NO.: S-1417 5 ratio. Lots 22 and 23 will not meet the maximum three to one ratio (no lot may be more than three times as deep as it is wide). Staff is supportive of this request. The proposed lots are adjacent to a cul-de-sac, which typically result in smaller lot widths. The applicant has indicated a 25-foot front building line adjacent to the residential streets and a minimum of 30-feet adjacent to Labette Drive consistent with the minimum required building lines in the Subdivision Ordinance. Staff is supportive of the indicated front building lines. Staff is supportive of the proposed request. The applicant has indicated minimum lot sizes to meet the minimum requirements of the Subdivision Ordinance and the minimum lot widths per the ordinance. The applicant is requesting a variance related to lot depth to width ratio for two of the lots, which staff feels would not cause any adverse impact on the adjoining properties. The applicant has indicated a rezoning will be sought should the proposed preliminary plat be approved. Staff feels development of the site with a lesser density would have a positive effect on the adjoining properties. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff recommends approval of the requested variance to allow an increased depth to width ratio for Lots 22 and 23 of the Amy Ridge Subdivision. Staff recommends the site be rezoned to R-2, Single-family District prior to any development or grading activities on the site. PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Pat McGetrick was present representing the request. There were two registered objectors present. Staff presented the item and stated to their knowledge there were no outstanding issues associated with the proposed request. Staff presented a recommendation of approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff stated they were also supportive of the requested variance to allow an increased depth to width ratio for Lots 22 and 23 of the Amy Ridge Subdivision. Staff presented a recommendation that the site be rezoned to R-2, Single-family District prior to any development or grading activities on the site. March 11, 2004 SUBDIVISION ITEM NO.: 8 (Cont.) FILE NO.: S-1417 6 Ms. Carolyn Heitman representing the John Barrow Neighborhood Association addressed the Commission in opposition of the proposed request. She stated the Neighborhood Action Plan included the area as medical office and medical related businesses. Ms. Heitman stated the site was surrounded by business that catered to the medical community. She stated the proposed development would not compliment the neighborhood. Mr. George Brown addressed the Commission in opposition of the proposed development. He stated the homes were to be lease purchase homes. He sated the neighborhood did not need any additional rental units. Mr. Pat McGetrick addressed the Commission on behalf of the applicant. He stated the request as to develop the site as single-family units. He stated the site was currently zoned MF-18 which would allow the site to develop at a density much greater than the applicant was proposing. Mr. McGetrick stated if the preliminary plat was approved the applicant would then request to rezoning of the site. There was a general discussion of the proposed request. Ms. Cindy Dawson, Deputy City Attorney, stated the Commission’s role was to review subdivision applications to ensure their compliance with City ordinances. She cited Richard vs. the City of Little Rock stating if the proposed subdivision was in compliance then the Commission had no choice but to approve the request. Commissioner Floyd questioned the timing of the rezoning request. Staff stated if the plat was approved the applicant would then be required to seek rezoning to be heard by the Commission at a later date. Staff stated the approval of the plat did not constitute approval of the rezoning. A motion was made to approve the proposed preliminary plat as presented by staff. The motion carried by a vote of 8 ayes, 1 noes and 2 absent. March 11, 2004 ITEM NO.: 9 FILE NO.: S-1418 NAME: Stalcup Subdivision Preliminary Plat LOCATION: On the Southeast corner of Taylor Loop Road and Gooch Drive DEVELOPER: Mike Stalcup 15901 Taylor Loop Road Little Rock, AR 72223 ENGINEER: McGetrick and McGetrick Engineers 319 President Clinton Avenue, Suite 202 Little Rock, AR 72201 AREA: 0.91 acres NUMBER OF LOTS: 3 FT. NEW STREET: 0 CURRENT ZONING: R-2, Single-family PLANNING DISTRICT: 19 CENSUS TRACT: 42.11 VARIANCES/WAIVERS REQUESTED: A five (5) year deferral of Master Street Plan requirements to Taylor Loop Road and Gooch Drive. A. PROPOSAL/REQUEST: The applicant proposes to subdivide an existing parcel into three single-family lots. There is an existing home located on proposed Lot 1 and the applicant has indicated a new home will be moved to proposed Lot 2. Proposed Lot 3 will be held for future development. The applicant is requesting a five-year deferral of the Master Street Plan requirements to construct Taylor Loop Road and Gooch Drive. B. EXISTING CONDITIONS: The site contains an existing single-family structure located near the intersection of Taylor Loop and Gooch Drive. Other uses in the area include single-family residences on acreage. The area to the southeast has been cleared for development of a proposed single-family neighborhood. March 11, 2004 SUBDIVISION ITEM NO.: 9 (Cont.) FILE NO.: S-1418 2 Taylor Loop Road is an unimproved roadway with open ditches for drainage. Gooch Drive is also unimproved with open ditches also being utilized for drainage. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has received one informational phone call from an area resident concerning the proposed development. All abutting property owners, the Westchester/Heatherbrae and Charleston Height/North Rahling Road Neighborhood Associations were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Taylor Loop is classified on the Master Street Plan as a collector street. With the plat, dedicate right-of-way to 30 feet from centerline. Gooch Drive would be classified as a local street with a minimum right-of-way width of 25 feet from centerline at all points. 2. A 20 foot radial dedication of right-of-way is required at the intersection of the streets. 3. Prior to final platting, provide design of streets conforming to the Master Street Plan. Construct one-half street improvements to these streets including curb, gutter, and 5-foot sidewalks with the planned development. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Entergy: No comment received. Center-Point Energy: Approved as submitted. SBC: Approved as submitted. Central Arkansas Water: A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. The Little Rock Fire Department needs to evaluate this site to determine whether additional public fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Contact Central Arkansas Water at 992-2438 for additional information. March 11, 2004 SUBDIVISION ITEM NO.: 9 (Cont.) FILE NO.: S-1418 3 Fire Department: Approved as submitted. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Pat McGetrick was present representing the request. Staff stated the proposed plat was to subdivide approximately 1 acre into three single-family lots. Staff stated there were additional items necessary to complete the review including the addition of the names/address and source of title of the landowner, the names of recorded subdivisions abutting the proposed plat area and a phasing plan. Staff also requested the applicant provide buildable areas after the dedication of right-of-way and the required 30-foot front yard building line adjacent to Taylor Loop Road. Public Works comments were addressed. Staff stated they would not support a deferral of street improvements to Taylor Loop Road. Staff stated they would support a deferral of street improvements to Gooch Drive if the intersection were improved. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised preliminary plat to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated the name/address and source of title of the landowner. The applicant has also indicated the names of recorded subdivisions abutting the proposed preliminary plat area and indicated the plat will be developed in one phase. The applicant has indicated buildable areas after the dedication of right-of-way and the required 30-foot front yard building line adjacent to Taylor Loop Road and 25-foot front yard building line adjacent to Gooch Drive. The Subdivision March 11, 2004 SUBDIVISION ITEM NO.: 9 (Cont.) FILE NO.: S-1418 4 Ordinance requires a 25-foot front building line adjacent to a residential street and a 30-foot front building line adjacent to a collector street. The applicant has met the minimum requirements. The total lot area proposed ranges from 7,720 square feet to 14,678 square feet. The proposed lot sizes are adequate to meet the minimum requirements of the Subdivision Ordinance. The applicant has requested a five-year deferral of street improvements to Taylor Loop Road and Gooch Drive. Staff is not supportive of the requested deferral of street improvements to Taylor Loop Road. Staff is however, supportive of a deferral of street improvements to Gooch Drive. Staff would recommend the applicant provide improvements to the intersection of Gooch Drive and Taylor Loop Road at this time. To staff’s knowledge there are no other outstanding issues related to the proposed request. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff recommends the street improvements to Taylor Loop Road be constructed as a part of final platting. Staff recommends approval of the deferral of street improvements to Gooch Drive but recommends the intersection of Gooch Drive and Taylor Loop Road be constructed at this time. PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Pat McGetrick was present representing the request. There were no registered objectors present. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented a recommendation of approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff also presented a recommendation that the street improvements to Taylor Loop Road be constructed as a part of final platting. Staff presented a recommendation of approval of the deferral of street improvements to Gooch Drive but a recommendation that the intersection of Gooch Drive and Taylor Loop Road be constructed at the time of final platting. March 11, 2004 SUBDIVISION ITEM NO.: 9 (Cont.) FILE NO.: S-1418 5 There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 10 FILE NO.: S-1419 NAME: Diamond T Subdivision Preliminary Plat LOCATION: On Crystal Valley Road DEVELOPER: Diamond Development Company P.O. Box 26052 Little Rock, AR 72210 ENGINEER: McGetrick and McGetrick Engineers 319 President Clinton Avenue, Suite 202 Little Rock, AR 72201 AREA: 12.11 acres NUMBER OF LOTS: 48 FT. NEW STREET: 1550 L.F. CURRENT ZONING: R-2, Single-family PLANNING DISTRICT: 17 CENSUS TRACT: 42.08 VARIANCES/WAIVERS REQUESTED: None requested. A. PROPOSAL/REQUEST: The applicant proposes to subdivide 12.11 acres located on Crystal Valley Road into 48 single-family lots. The site is located outside the existing city limits of Little Rock and the applicant has indicated annexation will be sought if the proposed plat is approved. The applicant is proposing an average lot size of 7560 square feet and the minimum lot dimension of 63-feet by 120-feet. The applicant has indicated 1550 linear feet of new street as a part of the development. B. EXISTING CONDITIONS: The site is located on Crystal Valley Road outside the City limits. The City limits adjoin the site to the west (Eagle Hill Community) making annexation a possibility. The site is currently vacant. The site as well as the general area March 11, 2004 SUBDIVISION ITEM NO.: 10 (Cont.) FILE NO.: S-1419 2 contain rolling hills. There are single-family homes located across Crystal Valley Road as well as north and south of the site. There is a PCD located south of the site that appears to be functioning as a single-family residence. Crystal Valley Road is an unimproved roadway with open ditches for drainage. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. All abutting property owners, the Crystal Valley Neighborhood Association and Southwest Little Rock United for Progress were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. The preliminary plat shows right-of-way dedications and street improvements as required by the Master Street Plan. However, sidewalk construction is also required on Crystal Valley and on West Diamond Way west to Diamond Cove. 2. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Site grading, and drainage plans will need to be submitted and approved prior to the start of construction. 3. Storm water detention ordinance applies to this property. Show the proposed location for storm water detention facilities on the plan. Show easements for all drainage and detention facilities. 4. Prepare a letter of pending development addressing streetlights as required by Section 31-403 of the Little Rock code. Contact Traffic Engineering at (501) 379-1813 (Steve Philpott) for more information regarding street light requirements. 5. Obtain permits prior to doing any street cuts or curb cuts. Obtain barricade permit prior to doing any work in the right-of-way. Contact Traffic Engineering at (501) 379-1817 (Derrick Bergfield) for more information. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: The site is located outside the city limits and outside the service boundary. No comment. Entergy: No comment received. Center-Point Energy: Approved as submitted. March 11, 2004 SUBDIVISION ITEM NO.: 10 (Cont.) FILE NO.: S-1419 3 SBC: Approved as submitted. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. A water main extension will be required in order to provide service to this property. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Located outside the City Limits. The site must annex to receive City services. Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional details. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Pat McGetrick was present representing the request. Staff stated the request was for a preliminary plat located outside the corporate limits. Staff stated since the proposed plat was located within the city’s planning jurisdiction it was appropriate to review the plat and as a condition of approval the applicant would be required to seek annexation. Staff stated it should be clear that support of the plat did not constitute support of the annexation. Staff requested the applicant provide additional information related to the proposed preliminary plat. Staff requested the applicant provide a 30-foot front building line adjacent to Crystal Valley Road. Staff also requested the applicant provide the names of owners of unplatted tracts abutting the proposed plat area. Staff requested the applicant provide a phasing plan, if applicable. Public Works comments were addressed. Staff stated a grading permit would be required prior to any grading activities on the site. Staff also stated the right-of- way for Crystal Valley Road was not sufficient to meet the minimum requirements of the Master Street Plan. March 11, 2004 SUBDIVISION ITEM NO.: 10 (Cont.) FILE NO.: S-1419 4 There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised preliminary plat to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated a 30-foot front building line adjacent to Crystal Valley Road (a collector street on the Master Street Plan) and a 25-foot front building line adjacent to the interior street. The applicant is requesting a variance to allow an increased lot depth to width ratio for Lots 19 – 20, 24 – 27 and 33 – 36. These lots are corner lots at the ends of cul-de-sacs. The Subdivision Ordinance requires no lot may be developed at a ratio greater than three times the depth to width ratio. Staff feels the proposed requested variance will have minimal to no adverse impact on the adjoining properties. Staff is supportive of the proposed requested variance. Staff is supportive of the proposed preliminary plat. For the most part the proposed preliminary plat meets the minimum requirements of the Subdivision Ordinance with regard to minimum lot width, minimum lot depth and the minimum square footage required for an R-2, Single-family zoned property. The site is located outside the City limits and should the preliminary plat be approved, the applicant will file for annexation. Staff is not however, indicating support of the future annexation request. The request will be evaluated on its merits based on the cost/benefit analysis prepared at the time of the request for annexation. Development of the plat as proposed is conditioned upon annexation to the City since the developer proposes to utilize Little Rock sewer service. Otherwise, to staff’s knowledge there are no outstanding issues associated with the proposed request. Staff feels the proposed preliminary plat should have minimal to no adverse impact on adjoining properties. I. STAFF RECOMMENDATION: Staff recommends approval of the requested preliminary plat subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff recommends approval of the requested variance to allow Lots 19 – 20, 24 – 27 and 33 – 36 to develop with an increased lot depth to width ratio. March 11, 2004 SUBDIVISION ITEM NO.: 10 (Cont.) FILE NO.: S-1419 5 The property must be annexed to the City of Little Rock prior to any grading activities or development of the site. PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Pat McGetrick was present representing the request. There were no registered objectors present. Staff stated the applicant had submitted a letter dated March 10, 2004 requesting the item be deferred to the March 25, 2004 Public Hearing. Staff stated the applicant was requesting additional time to meet the adjoining property owners to discuss their concerns. Staff stated the requested deferral would require a waiver of the By-laws related to the late deferral request. Staff stated they were supportive of the requested By-law waiver and the deferral request. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 11 FILE NO.: S-1420 NAME: Woodland Farms Acres Subdivision Preliminary Plat LOCATION: On the East end of Pine View Place DEVELOPER: Todd Larson 7409 Eagle Point North Little Rock, AR 72216 ENGINEER: Jewell Engineers 300 South Rodney Parham Road Little Rock, AR 72205 AREA: 1.999 acres NUMBER OF LOTS: 5 FT. NEW STREET: 261 L.F. CURRENT ZONING: R-2, Single-family PLANNING DISTRICT: 1 CENSUS TRACT: 42.09 VARIANCES/WAIVERS REQUESTED: None requested. A. PROPOSAL/REQUEST: The proposed subdivision is the reconfiguration of Lots 144, 145, 146 and 147 of the Longlea Phase VIIIB Subdivision Plat into five lots. The proposed lots will be served by the extension of Pine View Place to the east ending in a “hammer head” turn-around. The applicant has indicated the lots to be approximately one- quarter to one-half acre in size with two lots north and three lots south of the newly extended Pine View Place. The applicant has indicated all lots to have a 25-foot platted building line adjacent to the street. B. EXISTING CONDITIONS: The site is vacant and tree covered with significant outcropping of rocks. The roadbed, curb and gutter are in place for a portion of Pine View Place east of the existing pavement. The lots north of the street are very steep falling significantly from northeast to southwest. The lots south of the street do not have a significant grade change. March 11, 2004 SUBDIVISION ITEM NO.: 11 (Cont.) FILE NO.: S-1420 2 The site is located in the Longlea Phase VIIIB Subdivision. The area is predominately built-out with single-family homes. The Longlea Subdivision was constructed in the early to mid-1990s. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has received several informational phone calls from area residents. All abutting property owners and the Secluded Hills Property Owners Association were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or additional grading activities at the site. Site grading, and drainage plans will need to be submitted and approved prior to construction. Grading plans should address the treatment of the cut bank at the end of the Tee. 2. Curb and gutter was constructed at some time in the past, but the street was not completed. Repair or replace any curb and gutter that is damaged in the public right-of-way prior to completion of paving. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Entergy: No comment received. Center-Point Energy: Approved as submitted. SBC: No comment received. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. A water main extension will be required. A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact Central Arkansas Water at 992-2438 for additional information. March 11, 2004 SUBDIVISION ITEM NO.: 11 (Cont.) FILE NO.: S-1420 3 Fire Department: Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional details. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) The applicant was present representing the request. Staff briefly described the proposed request to Committee members and indicated to the applicant there were additional items necessary to complete the review process. Staff requested the applicant provide the proposed source of water, means of wastewater disposal and the front yard building setback lines on the proposed preliminary plat. Staff also requested the applicant provide the average size of the lots and the minimum lot size in the general notes section of the proposed preliminary plat. Staff questioned if the lots would be developed in one phase. The applicant indicated all lots would be final platted upon completion of the required improvements. Staff noted curb and gutter were constructed at some time in the past, but the street was not completed. Staff stated the applicant would be required to install the new street and repair or replace any cub and gutter that was damaged in the public right-of-way prior to the completion of paving. H. ANALYSIS: The applicant submitted a revised preliminary plat to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated Central Arkansas Water as the source of water and the Little Rock Wastewater Utility as the means of wastewater disposal for the proposed development. The applicant has indicated a twenty-five foot front yard building line adjacent to the street. The Subdivision Ordinance requires a twenty- five foot front yard building line to meet minimum requirements. The applicant has presented to staff the requested information concerning the treatment of the hillside at the end of Pine View Cove. The proposed street does not extend to the east beyond the proposed lots. The applicant has indicated March 11, 2004 SUBDIVISION ITEM NO.: 11 (Cont.) FILE NO.: S-1420 4 terracing and walls consistent with the City’s Land Alteration Ordinance. The area to the east is under a separate ownership and ending the street in this manner should allow development of this parcel at some point in the future should owners desire to develop the site. To Staff’s knowledge there are no outstanding issues associated with the proposed request. The applicant is proposing the placement of five homes on two acres and to develop the lots in a single phase. The area was previously approved for the development of four lots each containing approximately one-half acre. The proposed lots sizes (ranging from 0.24 to 0.45 acres) are more than adequate to meet the minimum lot size required by the Subdivision Ordinance. Staff feels the proposed subdivision should have minimal to no adverse impact on the surrounding area. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were no registered objectors present. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented the item with a recommendation of approval subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 12 FILE NO.: S-1421 NAME: Green Diamond Subdivision Preliminary Plat LOCATION: On Crystal Valley Road DEVELOPER: Diamond Development Company P.O. Box 26052 Little Rock, AR 72210 ENGINEER: McGetrick and McGetrick Engineers 319 President Clinton Avenue, Suite 202 Little Rock, AR 72201 AREA: 7.10 acres NUMBER OF LOTS: 30 FT. NEW STREET: 840 L.F. CURRENT ZONING: R-2, Single-family PLANNING DISTRICT: 17 CENSUS TRACT: 42.08 VARIANCES/WAIVERS REQUESTED: A variance to allow an increased lot depth to width ratio for Lots 14 – 17. A. PROPOSAL/REQUEST: The applicant proposes to subdivide 7.10 acres into 30 lots located outside the city limits of Little Rock. The applicant has indicated annexation will be sought should the preliminary plat be approved. The applicant proposes an average lot size of 61-feet by 132-feet resulting in an average square footage of 8052 square feet. The applicant has indicated a 30-foot front building line adjacent to Crystal Valley Road (a collector street) and 25-foot front building line adjacent to the interior residential street (Greenway Cove). The applicant is requesting a variance from the lot depth to width requirement of the Subdivision Ordinance for Lots 14 – 17. March 11, 2004 SUBDIVISION ITEM NO.: 12 (Cont.) FILE NO.: S-1421 2 B. EXISTING CONDITIONS: The site is located on Crystal Valley Road outside the City limits. The City limits adjoin the site to the south across Crystal Valley making annexation a possibility. The site has an abandoned single-family home located along Crystal Valley Road with the remainder of the site vacant. The site as well as the general area contain rolling hills. There are single-family homes located across Crystal Valley Road as well as to the west of the site. Crystal Valley Road is an unimproved roadway with open ditches for drainage. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. All abutting property owners, the Crystal Valley Neighborhood Association and Southwest Little Rock United for Progress were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. The preliminary plat shows right-of-way dedications and street improvements as required by the Master Street Plan. However, sidewalk construction is also required. 2. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Site grading, and drainage plans will need to be submitted and approved prior to the start of construction. 3. Storm water detention ordinance applies to this property. Show the proposed location for storm water detention facilities on the plan. Show easements for all drainage and detention facilities. 4. Prepare a letter of pending development addressing streetlights as required by Section 31-403 of the Little Rock code. Contact Traffic Engineering at (501) 379-1813 (Steve Philpott) for more information regarding street light requirements. 5. Obtain permits prior to doing any street cuts or curb cuts. Obtain barricade permit prior to doing any work in the right-of-way. Contact Traffic Engineering at (501) 379-1817 (Derrick Bergfield) for more information. March 11, 2004 SUBDIVISION ITEM NO.: 12 (Cont.) FILE NO.: S-1421 3 E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: The site is located outside the city limits and outside the service boundary. No comment. Entergy: No comment received. Center-Point Energy: Approved as submitted. SBC: Approved as submitted. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. A water main extension will be required in order to provide service to this property. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Located outside the City Limits. The site must annex to receive City services. Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional details. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Pat McGetrick was present representing the request. Staff stated the request was for a preliminary plat located outside the corporate limits. Staff stated since the proposed plat was located within the city’s planning jurisdiction it was appropriate to review the plat and as a condition of approval the applicant would be required to seek annexation. Staff stated it should be clear that support of the plat did not constitute support of the annexation. Staff requested the applicant provide additional information related to the proposed preliminary plat. Staff requested the applicant provide a 30-foot front building line adjacent to Crystal Valley Road. Staff also requested the applicant March 11, 2004 SUBDIVISION ITEM NO.: 12 (Cont.) FILE NO.: S-1421 4 provide the names of owners of unplatted tracts abutting the proposed plat area. Staff requested the applicant provide a phasing plan, if applicable. Public Works comments were addressed. Staff stated a grading permit would be required prior to any grading activities on the site. Staff also stated the right-of- way was not sufficient to meet the minimum requirements of the Master Street Plan for Crystal Valley Road. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised preliminary plat to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated a 30-foot front building line adjacent to Crystal Valley Road as required by the Subdivision Ordinance. Crystal Valley Road is classified on the Master Street Plan as a collector street, which per the Subdivision Ordinance requires a 30-foot front building line. The applicant has indicated a 25-foot front building line adjacent to the internal street (Greenway Cove) as required by the Subdivision Ordinance. The applicant is seeking a variance to allow four of the lots to develop with an increased lot depth to width ratio. Lots 14 – 17 are located on a cul-de-sac with a reduced street width. The lots do meet the minimum requirement for lot width at the building line (60-feet) as required by the Subdivision Ordinance. Staff feels the proposed lots developing with an increased depth to width ratio should have minimal to no adverse impact on adjoining properties and is supportive of the requested variance. Staff is supportive of the proposed preliminary plat. For the most part the proposed preliminary plat meets the minimum requirements of the Subdivision Ordinance with regard to minimum lot width, minimum lot depth and the minimum square footage required for an R-2, Single-family zoned property. The applicant has indicated the site is located outside the City limits and should the preliminary plat be approved, the applicant will file for annexation. Staff is not however, indicating support of the future annexation request. The request will be evaluated on its merits based on the cost/benefit analysis prepared at the time of the request for annexation. Development of the plat as proposed is conditioned upon annexation to the City since the developer proposes to utilize Little Rock sewer service. March 11, 2004 SUBDIVISION ITEM NO.: 12 (Cont.) FILE NO.: S-1421 5 Otherwise, to staff’s knowledge there are no outstanding issues associated with the proposed request. Staff feels the proposed preliminary plat should have minimal to no adverse impact on adjoining properties. I. STAFF RECOMMENDATION: Staff recommends approval of the requested preliminary plat subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff recommends approval of the requested variance to allow Lots 14 – 17 to develop with an increased lot depth to width ratio. The property must be annexed to the City of Little Rock prior to any grading activities or development of the site. PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Pat McGetrick was present representing the request. There were no registered objectors present. Staff stated the applicant had submitted a letter dated March 10, 2004 requesting the item be deferred to the March 25, 2004 Public Hearing. Staff stated the applicant was requesting additional time to meet the adjoining property owners to discuss their concerns. Staff stated the requested deferral would require a waiver of the By-laws related to the late deferral request. Staff stated they were supportive of the requested By-law waiver and the deferral request. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 13 FILE NO.: S-185-Q NAME: Little Rock Port Lease Area 3 Subdivision Site Plan Review LOCATION: 9001 Lindsey Road DEVELOPER: Agriliance LLC 402 Fork River Road Sherwood, AR 72120 ENGINEER: Garver Engineers, LLC 1010 Battery Street Little Rock, AR 72202 AREA: 14.2 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 CURRENT ZONING: I-3, Industrial District PLANNING DISTRICT: 25 CENSUS TRACT: 40.07 VARIANCES/WAIVERS REQUESTED: None requested. A. PROPOSAL/REQUEST: Agriliance, LLC has leased a building from Logistic Services, which is the agent of record for all facilities within the Port Authority complex. The site contains an old fertilizer building currently owned by the City through the Little Rock Port Authority. The applicant is in the process of remodeling the building to be used for bulk storage. The applicant has secured a five-year lease on the property with a renewal clause of another five years. For Agriliance, LLC to manage the use of the building it is necessary for them to place a small portable office building (60 foot by 12 foot) on the site. The applicant has indicated the building will be secured and skirted to give the appearance of a permanent office. Truck scales will be added to the site adjacent to the new building. B. EXISTING CONDITIONS: The site is located in the Port of Little Rock where there are numerous industrial buildings and activities. The site is vacant with buildings located to the east and March 11, 2004 SUBDIVISION ITEM NO.: 13 (Cont.) FILE NO.: S-185-Q 2 west of the proposed building location. There is a rail spur located along the western boundary of the property. Other uses in the area include industrial uses on I-3 zoned properties. Adjacent to the site, Lindsey Road is constructed to industrial road standards per the Master Street Plan; dead-ending nearby to an industrial site at the Arkansas River. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. All abutting property owners and the College Station Progressive League were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. No comment on proposed building addition. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer main extension required, with easements, if service is required for the project. Contact Little Rock Wastewater Utility at 688-1414 for additional details. Entergy: A 30-foot easement is required for existing overhead line. Maintain a 10-foot building line from overhead line. Center-Point Energy: Approved as submitted. SBC: Approved as submitted. Central Arkansas Water: Contact Central Arkansas Water at 992-2438 regarding the size and location of the water meter. Fire Department: Approved as submitted. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. March 11, 2004 SUBDIVISION ITEM NO.: 13 (Cont.) FILE NO.: S-185-Q 3 Landscape: Landscaping will be required in association with required on-site parking. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) The applicant was present representing the request. Staff presented an overview of the proposed request indicating the use was for the placement of an additional structure on an existing site necessitating a multiple building site plan review for the proposed development. Staff stated there were few outstanding issues associated with the proposed request. Staff requested details concerning signage, any proposed fencing and locations of any outdoor storage. Staff also requested the applicant indicate the location of the proposed building related to the proposed future access route to properties located to the west. Staff noted the Port Authority had submitted a letter indicating a 60-80 foot access route to serve the tracts to the west was critical for the long term use of the river access area. There was no further discussion of the item and the Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plan to staff addressing the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated the location of the proposed office building and the location of the proposed scales. The applicant has indicated a future right-of-way 60 feet to allow access to properties located to the west which are currently undeveloped and owned by the Little Rock Port Authority. The properties are currently zoned I-3 and shown on the Port’s Master Plan for future development. The applicant has indicated the placement of a building containing equipment for the scales and a proposed office location. The scales will be located adjacent to the future right-of-way. The placement in this location will allow sufficient traffic movement for truck traffic entering and exiting the scales after loading of materials. The applicant has indicated there will be no new fencing, no additional signage and no new areas of outdoor storage located on the site. The applicant has indicated building signage will be added to identify the company. The proposed signage will comply with wall signage allowed in industrial zones or not more than ten percent of the building façade area. March 11, 2004 SUBDIVISION ITEM NO.: 13 (Cont.) FILE NO.: S-185-Q 4 Staff is supportive of the proposed request as is the Little Rock Port Authority. The applicant is in the process of refurbishing an old building located at the Port to be utilized in their operation. The applicant has contracted with the Port with a five-year lease agreement renewable at the end of five years for an additional five years. The proposed development should have minimal impact on the adjoining properties. The proposed use is industrial in nature as are other activities in the area. I. STAFF RECOMMENDATION: Staff recommends approval of the proposed request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were no registered objectors present. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented the item with a recommendation of approval of the proposed request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 14 FILE NO.: S-1065-C NAME: Chenonceau Commercial Lots 1 and 2 Subdivision Site Plan Review LOCATION: On the Southeast corner of Cantrell Road and Chenonceau Boulevard DEVELOPER: Flake Family Partnership 225 West Capitol Avenue Little Rock, AR 72201 ENGINEER: White-Daters and Associates #24 Rahling Circle Little Rock, AR 72223 AREA: 3.22 acres NUMBER OF LOTS: 2 FT. NEW STREET: 0 CURRENT ZONING: C-3, General Commercial District PLANNING DISTRICT: 19 - Chenal CENSUS TRACT: 42.11 VARIANCES/WAIVERS REQUESTED: None requested. BACKGROUND: A two lot preliminary plat was approved by the Little Rock Planning Commission at their May 16, 1995 Public Hearing. The proposal included a commercial and office subdivision on a 16.66-acre tract. The site has frontages on both Cantrell Road and Chenonceau Boulevard. One interior cul-de-sac street, approximately 500 feet in length was proposed within the subdivision. Lots ranged in size from 0.8 acres to 2.14 acres, with the average lot size being 1.44 acres. The Final Plat for Lot 1 was executed on January 29, 1996. The Final Plat for Lot 2 was executed on December 19, 2003. A. PROPOSAL/REQUEST: The applicant is proposing the construction of two buildings on this site which was previously final platted as two lots. The applicant is proposing the construction of a 2,700 square foot bank building located on the corner of Cantrell Road and Chenonceau Boulevard and the construction of a retail building containing 12,000 square feet. The retail building is situated where it March 11, 2004 SUBDIVISION ITEM NO.: 14 (Cont.) FILE NO.: S-1065-C 2 cross the lot line requiring the applicant to seek a multiple building site plan review. The proposed site plan indicates two sign locations, one on Chenonceau Boulevard, the second is proposed at the intersection of Cantrell Road and Chenonceau Boulevard. The applicant has indicated building setbacks along Cantrell Road conforming to required setback of the Highway 10 Design Overlay District requirements. The applicant has indicated 120 parking spaces for the proposed development. B. EXISTING CONDITIONS: The site is undeveloped and is heavily wooded and contained in a large area currently zoned for non-residential uses. The northern two-thirds of the overall area is zoned C-3; the southern one-third of the area is zoned O-2. The land to the east, south and southwest is all zoned R-2. Across Chenonceau Boulevard to the west is a MF-18 zoned tract currently under development. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. All residents who could be identified located within 300-feet of the site, the Aberdeen Court Property Owners Association, the Bayonne Place Property Owners Association, the Margeaux Property Owners Association, the Maywood Manor Neighborhood Association and the DuQuesne Place Property Owners Association and all owners of property located within 200-feet of the site were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Chenonceau is classified on the Master Street Plan as a minor arterial. A minimum dedication of right-of-way 45 feet from centerline plus 10 foot additional for a right turn lane will be required. 2. Highway 10 at Chenonceau has been approved for a traffic signal when warrants are met. The proposed development located at a signalized intersection will require an additional left turn and right turn lane on Cenonceau. Provide a plan showing additional lanes, right-of-way and 5-foot sidewalk. 3. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Site grading, and drainage plans will need to be submitted and approved prior to March 11, 2004 SUBDIVISION ITEM NO.: 14 (Cont.) FILE NO.: S-1065-C 3 the start of construction. 4. Storm water detention ordinance applies to this property. Show the proposed location for storm water detention facilities on the plan. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Entergy: Approved as submitted. Center-Point Energy: Approved as submitted. SBC: Approved as submitted. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZA) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact Carroll Keatts at 992-2431 if you would like to discuss backflow prevention requirements for this project. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Approved as submitted. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: Areas set aside for buffer and landscaping appear to meet with the landscape ordinance and the Highway 10 Design Overlay District standards. March 11, 2004 SUBDIVISION ITEM NO.: 14 (Cont.) FILE NO.: S-1065-C 4 Screening is required due to the residential use along the eastern perimeter of the site. This screening to be a six (6) foot high opaque screen, either a wooden fence with its face side directed outward, a wall, or dense evergreen plantings. An automatic irrigation system to water landscaped areas will be required. Prior to a building permit being issued, it will be necessary to provide an approved landscape plan stamped with the seal of a Registered Landscape Architect. The City Beautiful Commission recommends preserving as many existing trees as feasible on this tree-covered site. Credit toward fulfilling Landscape Ordinance requirements can be given when properly preserving trees of six (6) inch caliper or larger. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Joe White was present representing the applicant. Staff stated the request was a multiple building site plan review since one of the buildings was proposed to cross an existing lot line. Staff requested the applicant provide additional information concerning the proposed development. Staff requested the applicant indicate dumpster screening, the proposed days and hours of operation and details of any proposed signage. Staff also stated the proposed side yard landscaping strip along the eastern property line did not meet the required Highway 10 Design Overlay District Standards. Staff stated the required landscaping strip along the eastern property line should be an average of twenty- five feet. Staff suggested the applicant reduced the area set aside along the western perimeter (adjacent to Chenonceau Boulevard) to increase the area along the eastern perimeter. Staff stated the platted utility easement would have to be abandoned through Board of Directors action. Public Works comments were addressed. Staff stated Chenonceau was scheduled for signalization, which would require an additional turn lane. Staff requested the applicant provide right-of-way for the additional lanes. Mr. White questioned if the right-of-way could come from the existing median. Staff stated narrowing the median was an option. Staff stated the proposed driveway location along Cantrell Road was acceptable. Landscaping comments were addressed. Staff noted the areas set aside for buffer and landscaping appeared to meet the minimum landscape ordinance and the Highway 10 Design Overlay District requirements. Staff stated screening would be required along the eastern property line. March 11, 2004 SUBDIVISION ITEM NO.: 14 (Cont.) FILE NO.: S-1065-C 5 There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plan to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated an increased side yard buffer adjacent to the residentially zoned property to the east. The applicant has indicated a twenty-five average buffer, consistent with the Highway 10 Design Overlay District requirements. The applicant has indicated screening along the eastern property line sufficient to provide year around screening to the residentially zoned properties located to the east. Staff is supportive of the proposed landscaping and buffering. The applicant has indicated a single-ground mounted monument sign adjacent to Cantrell Road, consistent with signage allowed by the Highway 10 Design Overlay District or a maximum of ten feet height and seventy-two square feet in area. The applicant has indicated a second sign located on Chenonceau Boulevard also a maximum of ten feet in height and seventy-two square feet in area. Staff is supportive of the proposed signage. The applicant has indicted two dumpster locations on the proposed site plan. The first is located near the northern end of the retail building. The applicant has indicated the days and hours of operation to be from 7:00 am to 9:00 pm seven days per week. Staff is supportive of the proposed dumpster locations and the days and hours of operation. Staff would however, recommend the dumpsters be serviced during daylight hours to minimize the impact on the single-family homes located to the east. A 25-foot utility and access easement was final platted as a part Lots 1 and 2 of the Chenonceau Commercial Subdivision. The applicant is requested the easement be abandoned as a part of the site plan review process. The applicant will follow through with abandonment to the Board of Directors if recommended for approval by the Commission. Staff is supportive of the request. The applicant has indicated cross access will be provided for both access and parking. The applicant has not indicated if the additional turn lane will be added to Chenonceau Boulevard. Public Works has indicated the Chenonceau Boulevard and Cantrell Road intersection is scheduled for signalization when warrants are met. Staff feels the addition of a left and right turn lane at the intersection is critical to facilitate traffic movement in the area. Staff recommends the additional turn lanes be added to Chenonceau Boulevard. March 11, 2004 SUBDIVISION ITEM NO.: 14 (Cont.) FILE NO.: S-1065-C 6 To Staff’s knowledge there are no outstanding issues associated with the proposed request. Staff feels the development should have minimal to no adverse impact on adjoining properties if the required infrastructure is put in place to facilitate traffic and buffers are put as proposed to protect the adjoining properties. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff recommends the right and left turn lanes be added to Chenonceau Boulevard to enhance traffic movement in the area. Staff recommends the dumpsters service be limited to daylight hours. Staff recommends approval of the requested abandonment of the access and utility easement located within the proposed site. PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Joe White was present representing the request. There were no registered objectors present. Staff stated the applicant had submitted a letter dated March 8, 2004 requesting the item be deferred to the April 22, 2004 Planning Commission Public Hearing. Staff stated the deferral request would require a waiver of the By-laws related to the late deferral request. Staff stated the applicant requested additional time to work with an adjoining property owner. Staff stated an application would be filed on March 15, 2004 related to the adjoining site and would be heard by the Commission at their April 22, 2004 Public Hearing. Staff stated they were supportive of the By-Law Waiver and the deferral request. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 15 FILE NO.: S-1229-A NAME: Barrow Road Apartments Subdivision Site Plan Review LOCATION: On the West side of John Barrow Road, South of Tanya Drive DEVELOPER: WTH Development 8503 Asher Avenue Little Rock, AR 72204 ENGINEER: Roberts and Williams Associates Landscape Architects 1501 North University Avenue Little Rock, AR 72207 AREA: 13 Acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 L.F. CURRENT ZONING: MF-12 PLANNING DISTRICT: 11 CENSUS TRACT: 24.04 VARIANCES/WAIVERS REQUESTED: None requested. BACKGROUND: The applicant proposed to construct 34 buildings of multi-family housing on this 25.57 acre property located on the west side of John Barrow Road, just south of Tanya Drive. The site was zoned MF-12 (Multi-family Residential – 12 units per gross acre) on January 3, 1978 with Ordinance No. 13,393 adopted by the Little Rock Board of Directors. The west 110 feet of the property ownership was left as R-2 zoning, when the remainder of the property was zoned, to serve as a buffer between this site and the single-family property to the west. The applicant proposed to develop multi-family residences on the site. The density proposed was under the twelve units per gross acre as allowed by the City’s Zoning Ordinance. The request was to be heard by the Planning Commission at their January 21, 1999 Public Hearing but was withdrawn by the applicant prior to the Public Hearing. March 11, 2004 SUBDIVISION ITEM NO.: 15 (Cont.) FILE NO.: S-1229-A 2 A. PROPOSAL/REQUEST: The applicant is proposing to develop this 34-acre site in a two-part development. The site is currently zoned MF-12 which allows for the development of multi- family housing at a density of 12-units per acre. The applicant has indicated a desire to develop 20.64 acres as a Planned Residential Development (Z-3173-C – Item #19) and the remaining 13.16 acres as a multiple building multi-family residential development. The applicant has indicated the development of the multi-family portion of the site with 126 units (9.6 units per acre). The proposed site plan includes signage for both the single-family subdivision and the multi-family development. Signage will be located near the drive into the multi-family development and at the entrance to the single-family subdivision. The proposed site plan includes a clubhouse, two lakes and two play ground recreational spaces. The development also contains a series of pedestrian trails connecting the multi-family and the single-family development. The clubhouse and pool will be developed as a part of a property owners association through the planned residential development allowing both the single-family homes and the multi-family residents access to the facilities. B. EXISTING CONDITIONS: The site is vacant and tree covered sloping from the north and south to the center of the site. There is a developed nursing home located at the northeast corner of the site. Park View High School is located to the northeast of the site and single-family homes are located to the southeast. To the south of the site is an area zoned MF-24 with a welding shop and a separate building containing a contractor’s office. Single-family homes are located along West 29th Street to the south of the site. To the west of the site are also single-family homes in the Twin Lakes/Campus Place Neighborhood. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has received several phone calls in opposition of the proposed use from area residents. All residents who could be identified located within 300-feet of the site, the John Barrow Neighborhood Association, the Campus Place Property Owners Association, the Twin Lakes “B” Property Owners Association, Twin Lakes B Special Improvement District and all owners of property located within 200-feet of the site were notified of the public hearing. March 11, 2004 SUBDIVISION ITEM NO.: 15 (Cont.) FILE NO.: S-1229-A 3 D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. The proposed street from John Barrow going west to the last apartment entrance should be designed as a 36 foot collector street. The remainder can be 31 foot as shown on the plan. 2. Provided curve data for the collector street. The standard radius for a normal crown is 275 feet with a 100-foot tangent between reverse curves. 3. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Site grading, and drainage plans will need to be submitted and approved prior to the start of construction. 4. Alteration of the water course will require approval from the Little Rock District of the US Army Corps of Engineers prior to start of work. 5. Storm water detention applies to the proposed development. Assuming the 0.67-acre lake will serve as detention for the apartment complex, a wider drainage easement for the lake to the John Barrow right-of-way will be required. 6. John Barrow Road is classified on the Master Street Plan as a minor arterial. A minimum dedication of right-of-way 45 feet from centerline will be required. 7. Repair, replace, or provide any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. 8. Prepare a letter of pending development addressing streetlights as required by Section 31-403 of the Little Rock code. Contact Traffic Engineering at (501) 379-1813 (Steve Philpott) for more information regarding street light requirements. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: A private sewer main crosses the property. The private sewer main must be relocated and dedicated to Little Rock Wastewater Utility as a public sewer main with easements. Capacity Contribution Analysis required, contact Little Rock Wastewater Utility at 688-1414 for additional details. Entergy: No comment received. Center-Point Energy: Approved as submitted. SBC: No comment received. March 11, 2004 SUBDIVISION ITEM NO.: 15 (Cont.) FILE NO.: S-1229-A 4 Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. The facilities on-site in the area of the apartments will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. A water main extension will be required in order to provide service to this property. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional details. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: Areas set aside for buffer and landscaping appear to meet with the landscape and buffer requirements. Screening is required along the southern perimeter of the site adjacent to the residentially zoned properties. A six (6) foot high opaque screen, either a wall, or wooden fence with its face side directed outward, or dense evergreen plantings, is required. An automatic irrigation system to water landscaped areas will be required. Prior to a building permit being issued, it will be necessary to provide an approved landscape plan stamped with the seal of a Registered Landscape Architect. The City Beautiful Commission recommends preserving as many existing trees as feasible on this tree-covered site. Credit toward fulfilling Landscape Ordinance requirements can be given when properly preserving trees of six (6) inch caliper or larger. March 11, 2004 SUBDIVISION ITEM NO.: 15 (Cont.) FILE NO.: S-1229-A 5 G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Barry Williams was present representing the request. Staff stated there were two items related to the site, one a single-family development, the second a multi-family site plan review. Staff stated the two items were reviewed separate and would be discussed together. Staff noted there were additional items necessary on each item to complete the review process. Staff first requested additional information for the site plan review. Staff requested the applicant provide details of signage, fencing and a phasing plan, if applicable. The staff also requested the applicant provide the lot size and total building coverage in the general notes section of the site plan. Mr. Williams noted the proposed multi-family units would be constructed as split- level units to better adhere to the terrain. Mr. Williams stated the maximum building height would be 35-feet. Staff requested the applicant provide maximum building height, front yard building lines and total buildable areas for the proposed PRD portion of the development. Staff stated since the request was a PRD there were no setbacks except those imposed at the time of approval. Staff requested the applicant provide details of any proposed signage associated with the new single-family development. Staff requested the applicant provide details concerning lot sizes and the source of water and the means of wastewater disposal. Public Works comments were addressed. Staff stated the proposed street extending west from John Barrow Road should be designed to a 36-foot collector street. Mr. Williams stated the desire of the developers was to narrow the streets to reduce speeds. Staff stated they could support the reduced standard in the single-family portion of the development but the street adjacent to the multi-family should be wider. Staff questioned the watercourse proposed on the site plan. Staff stated the storm water detention ordinance would apply to the site. Staff stated a wider drainage easement for the lake to John Barrow Road right-of-way would be required. Mr. Williams stated the desire was to allow the lake to serve as detention as well as a water feature. Landscaping comments were addressed for the apartment site. Staff noted there would not be any landscaping required for the PRD (single-family) portion of the development. Staff noted the areas set aside for buffering appeared to meet the landscape ordinance requirements for the multi-family portion of the development. Staff also noted screening would be required along the southern perimeter where the site’s multi-family portion adjoined single-family zoned property. March 11, 2004 SUBDIVISION ITEM NO.: 15 (Cont.) FILE NO.: S-1229-A 6 There were no further items for discussion. The Committee then forwarded each item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plan to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated details concerning the proposed signage. The applicant has indicated signage consistent with signage allowed in multi-family zones or not to exceed twenty-four square feet in sign area and six feet in height. The applicant indicated there would not be any fencing as a part of the development except in areas, around the lake/detention for security if necessary. The applicant has also indicated fencing will not be added to the recreational areas unless required for safety. The applicant has indicated the development of the site with fourteen buildings both two and three story. The applicant has indicated the maximum building height will be 35-feet on all structures. Due to the topography of the site, seven of the buildings will be two stories on the front and three stories on the back; maximizing the site without developing the site with towering buildings. The applicant has indicated seven of the buildings as two story buildings. The applicant has indicated a total building coverage of 220,500 square feet. The applicant has indicated a total lot area of 573,467 square feet. The minimum lot area per family per the zoning ordinance requires a minimum lot area of 3600 square feet per family or 453,600 square feet. The proposed minimum lot area exceeds the required minimum lot area per the zoning ordinance. The applicant has also indicated the minimum building setback and building separation, which also exceed the minimum requirements. The applicant has indicated the minimum building setback of 64.7 feet from John Barrow Road and 86.5 feet from the southern property line. The zoning ordinance requires a minimum setback from the property line of 25-feet. The minimum building separation allowed is ten feet. The applicant has indicated a minimum building separation of 26.7 feet. The applicant has indicated a playground area on the proposed site plan to serve the multi-family development. The applicant has also indicated a play and recreational area located in Tract C adjacent to the clubhouse office and pool. The applicant has also indicated pedestrian trails through out the development connecting the single-family and multi-family portions of the development. The applicant has indicated these amenities as a part of the Planned Residential Development (Item #19 – File No. Z-3173-C) but has indicated both the single- March 11, 2004 SUBDIVISION ITEM NO.: 15 (Cont.) FILE NO.: S-1229-A 7 family and the multi-family developments will have access to use the facilities. This too exceeds the minimum requirements of the ordinance. The applicant has indicated 252 parking spaces as a part of the development. The minimum parking requirement for a multi-family development of 126 units would be one and one-half spaces per unit or 189 parking spaces. The applicant has provided two spaces per unit, more than adequate to serve the proposed development. The applicant has indicated a 35-foot buffer along the southern perimeter of the site to remain undisturbed for a large portion of the area. The applicant has indicated the undisturbed buffer will not be maintained in the area around the lake or where the overflow exits the lake to John Barrow Road. Staff feels this appropriate. The applicant has indicated year around screening will be provided to buffer the single-family zoned properties to the south. The applicant has also included a tract on the site plan that will not be developed to buffer the single- family to the west. Staff is supportive of the proposed development. Staff feels with the overall development plan, the development of single-family and multi-family in an integrated neighborhood the development should be successful due the mixture of residential uses. The applicant has also included amenities for the overall development to provide recreational activities for the single-family and the multi- family uses. The applicant has exceeded the minimum requirements of the ordinance and staff feels if the development is constructed as proposed including the single-family portion of the development, there should be minimal to no adverse impact on adjoining properties. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were several registered objectors present. Staff presented the item along with a related site plan review (Item # 15 – File No. S-1229-A) indicating support for the rezoning request and the site plan review request. Staff stated they were supportive of reducing the rear radius to 75-feet and narrowing the street to 31-feet of pavement. Staff stated the applicant had indicated the request for the reduced standard was to act as a traffic calming device and the reduced street standard would comply with minor residential street standards. March 11, 2004 SUBDIVISION ITEM NO.: 15 (Cont.) FILE NO.: S-1229-A 8 Mr. Barry Williams addressed the Commission on behalf of the applicant. He stated the desire of the development was to develop the site with a mix of single-family and multi- family units. He stated the proposed development included a clubhouse and pool area that would be shared by the apartment dwellers as well as the single-family homeowners. He stated the development also included a series of trails and pathways to connect the two developments and allow for integration of the neighborhood. Ms. Carolyn Heitman addressed the Commission in opposition of the proposed development. She stated the Barrow Road Neighborhood was not in support of the proposed development. Ms. Heitman stated traffic was the primary concern of the Neighborhood Association. She stated the desire was to allow the area to develop with less intense uses. Ms. Heitman stated the John Barrow Road Neighborhood Association had met with the developers but the other Association’s in the area had not met with the developers. She requested the Commission defer the item until the developer had met with all the affected neighborhoods and the neighborhoods had the opportunity to discuss the potential project. Mr. George Brown addressed the Commission in opposition of the proposed request. He stated the neighborhood did not want additional apartments. He stated the area currently had 1000 plus apartments which were not fully occupied. He stated traffic was currently a nightmare and the addition of more apartments would only compound the problem. Ms. Francis Harris-Waddell addressed the Commission in opposition of the proposed request. She stated the neighborhood located to the west of the site had signed a petition, which had been given to the Commission. She stated the petition contained 100 percent of the homeowners, which would be directly affected by the proposed development. Ms. Waddell stated apartments would have a devastating effect on the single-family homes in the area. Commissioner Rector stated the discussion was not related to the apartments. He stated the site was zoned for multi-family housing and the proposed development had met all the minimum requirements of the subdivision ordinance for a site plan review. He stated the Commission had no choice but to approve the proposed apartment development. He stated the Commission could discuss the single-family portion of the request which was a rezoning request to down zone approximately two-thirds of the site. Ms. Waddell questioned the square footage of the homes, the estimated sales price, the number of bedrooms and if the homes would have garages. Mr. Brad Norris of the Campus Place Neighborhood Association addressed the Commission in opposition of the proposed request. He stated his neighborhood had not had the opportunity to meet with the developers and discuss the proposed site plan. He March 11, 2004 SUBDIVISION ITEM NO.: 15 (Cont.) FILE NO.: S-1229-A 9 requested the Commission defer the item until all the affected neighborhoods had the opportunity to meet with the developers. Chairman Mizan questioned the concerns of the neighborhood. He asked if they were related to issues raised by Ms. Waddell. Mr. Norris stated those were a few of the issues. He stated others were related to landscaping, buffering, detention, and building design. Mr. Kevin Howard, the applicant, addressed the Commission to answer questions related to the proposed development. He stated the homes would be two to four bedroom homes and range in size from 1,100 square feet to 1,800 square feet. He stated the estimated sales price was from $100,000 to $140,000. He stated the lots averaged in size from 8,200 square feet to 11,000 square feet. He stated the development would establish a homeowners association to ensure the green spaces and clubhouse were maintained properly. There was a general discussion concerning the drainage, detention and the proposed lake areas. There was also a general discussion concerning the placement of sidewalks within the proposed development. The applicant indicated sidewalks and trails would be used through out the development to allow for connectivity. Mr. Williams stated the request was to allow the clubhouse within the planned development portion of the request. He stated the apartments would be developed in two phases with seven buildings being constructed in the first phase and six buildings in the second phase. He stated the clubhouse and pool would also be constructed in the first phase to ensure the development of the single-family portion of the site. He stated once the PRD was established the developer would have no choice but to construct the single-family portion of the development or return to the Commission for a rezoning. There were questions related to the street and the narrowness of the proposed street. Staff stated the proposed development would handle less than 1300 cars per day, much less than a standard residential street. Staff stated the narrow street was acceptable and the curves and radius, if increased to 75-feet, would also be acceptable. Commissioner Adcock questioned if no parking signs would be available. Staff stated parking would typically be allowed on one side of the street. Mr. Williams stated if Public Works required three lanes at the intersection this would not be an issue. He stated the right-of-way would be in place to allow a 36-foot street at the intersection. There was a general discussion concerning the proposed management of the apartment development. Mr. Howard stated the developers had not executed a contract but were interviewing potential management firms. He stated two were local firms. March 11, 2004 SUBDIVISION ITEM NO.: 15 (Cont.) FILE NO.: S-1229-A 10 Chairman Mizan stated a condition of the approval would be the developer meet with the neighborhood prior to the Board of Directors meeting. A motion was made to approve the requested site plan review as amended. The motion carried by a vote of 8 ayes, 1 noe and 2 absent. March 11, 2004 ITEM NO.: 16 FILE NO.: S-1416 NAME: Black Subdivision Site Plan Review LOCATION: 2807 Willow Springs Road DEVELOPER: Donald W. Black, Sr. 2807 Willow Springs Road Little Rock, AR 72206 ENGINEER: Donald W. Brooks 20820 Arch Street Pike Hensley, AR 72065 AREA: 10.0 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 CURRENT ZONING: Area not zoned PLANNING DISTRICT: 28 CENSUS TRACT: 40.06 VARIANCES/WAIVERS REQUESTED: A waiver of boundary street improvements to Willow Springs Road. A. PROPOSAL/REQUEST: The site is located outside the City limits in an area where the City has Subdivision Control but does not exercise zoning. The applicant has submitted a request for a multiple building site plan review for the placement of a 73-foot by 38-foot (triple wide) manufactured home. The site contains approximately ten acres, more than adequate to meet the Arkansas Department of Health requirements for septic tank installation. B. EXISTING CONDITIONS: The site contains an existing single-family structure with several outbuildings. Other uses in the area include single-family homes both “stick-built” and manufactured homes all on acreage. Willow Springs Road is an unimproved roadway with open ditches for drainage and no sidewalk in place. March 11, 2004 SUBDIVISION ITEM NO.: 16 (Cont.) FILE NO.: S-1416 2 C. NEIGHBORHOOD COMMENTS: As of this writing, staff has received one informational phone call concerning the proposed use from an area resident. Southwest Little Rock United for Progress and all owners of property located within 200-feet of the site were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Willow Springs Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required. 2. Public Works would support a one-time waiver of Boundary Street Improvements for this multiple building site plan. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: The site is located outside the service area. No comment. Entergy: No comment received. Center-Point Energy: Approved as submitted. SBC: Approved as submitted. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. The Fire Department having jurisdiction needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Located outside the City limits. No comment. County Planning: No comment received. CATA: No comment received. March 11, 2004 SUBDIVISION ITEM NO.: 16 (Cont.) FILE NO.: S-1416 3 F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) The applicant was not present. Staff stated there were no outstanding issues associated with the proposed request. Staff stated the request was to place a triple wide manufactured home on a ten-acre parcel where an existing residence stood. Staff stated the request was located in an area where the City exercised subdivision control but not zoning. Staff noted they had contacted the applicant and requested the structure be placed a minimum of thirty feet from the new property line once right-of-way was dedicated and the applicant indicated this would not be an issue. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant has indicated the new home will be placed a minimum of thirty feet from the new property line near the southwest portion of the site. A new driveway will be extended from Willow Springs Road to serve the new residence. The applicant has indicated a covered parking pad will be added at a later date, near the northeast corner of the home. Staff is supportive of the proposed request. The proposed placement of a second residence on the site (a 38 foot by 78 foot manufactured home) should have minimal to no adverse impact on the surrounding area. The use is consistent with other uses in the area since the area contains both “stick built” and manufactured homes. The site contains sufficient land area to contain a septic system, which will be required by the Arkansas Department of Health. Typically two acres are required for a septic system to perk thus the ten acre site should be more than adequate to service the two homes. The applicant is requesting a one-time waiver of boundary street improvements to Willow Springs Road. Staff is supportive of this request. The applicant is proposing the placement of a second residence on the site and is not proposing a subdivision at this time. Staff feels the requirement of boundary street improvements at this time is unwarranted and supports a one-time waiver of the street improvement requirement. March 11, 2004 SUBDIVISION ITEM NO.: 16 (Cont.) FILE NO.: S-1416 4 To staff’s knowledge there are no outstanding issues associated with the proposed request. Staff feels the proposed addition of the manufactured home should have minimal to no adverse impact on the surrounding area. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff recommends approval of the requested one-time waiver of boundary street improvements to Willow Springs Road. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were no registered objectors present. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented the item with a recommendation of approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff also presented a recommendation of approval of the requested one-time waiver of boundary street improvements to Willow Springs Road. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 17 FILE NO.: Z-5097-F NAME: Murphy Oil Company USA Fueling Station Zoning Site Plan Review LOCATION: On the Southeast corner of Cantrell Road and Chenal Parkway DEVELOPER: Wal-Mart Store, Incorporated 702 S.W. 8th Street Bentonville, AR 72716-0550 ENGINEER: Carlson Consulting Engineers 7731 Highway 70, Suite 210 Bartlett, TN 38133 CURRENT ZONING: C-3, with conditions - General Commercial District with site plan review. ALLOWED USES: General Commercial PROPOSED ZONING: C-3 PROPOSED USE: C-3, General Retail – Construction of a Murphy Oil Fueling Station VARIANCES/WAIVERS REQUESTED: None requested. BACKGROUND: On December 20, 1988, the Board of Directors adopted Ordinance No. 15,603, which rezoned several tracts of land as a part of the Deltic Master Plan from Residential zoning to various multi-family, office and commercial zoning districts. That action rezoned 7.860 acres located at the southeast corner of Highway 10 and Chenal Parkway from R-2 to C-3. The approval of the C-3 zoning was conditioned upon a site plan review, by the Planning Commission, prior to development and a provision of a 40-foot landscaped setback adjacent to Highway 10 and the Chenal Parkway. Ordinance No. 16,459 rezoned additional properties contained within the proposed site. The Ordinance was approved by the Board of Directors on July 20, 1993, and rezoned 8.7051 acres from R-2 to C-3, General Commercial. March 11, 2004 SUBDIVISION ITEM NO.: 17 (Cont.) FILE NO.: Z-5097-F 2 Ordinance No. 18,628, adopted by the Board of Directors on January 2, 2002, rezoned an additional 10.92 acres from R-2 to C-3, General Commercial. This area was to the south of the C-3 zoned property and adjacent to Chenal Parkway. At the time of rezoning the applicant also requested and was approved rezoning further south. The zoning approved was O-2 on 10 plus acres adjacent to the Parkway and 10 plus acres of OS zoning nearer the single-family neighborhood to the east. As a condition of the 1988 zoning, approximately six (6) acres of the site was subject to site plan review. The applicant submitted a proposed site plan for review by the Little Rock Planning Commission at their October 31,2002 Public Hearing. The Commission approved the proposed site plan with a modification to the pole height of the proposed lighting in the parking lot. The applicant intended to develop the 28.4 acres as a 210,396 square foot Wal-Mart Super center, associated parking and service areas. The parking lot consisted of 988 parking spaces, including 24 handicap accessible parking spaces. Two driveways were to provide access to the proposed project from Cantrell Road and two driveways from Chenal Parkway. The southernmost driveway on Chenal Parkway will align opposite the existing Northfield Drive and is proposed to be signalized. This drive would be a shared drive with the currently undeveloped property to the south (zoned O-2), thus helping to limit future access points on the Parkway. A. PROPOSAL/REQUEST: The applicant is proposing the placement of a single story 440 square foot kiosk on Lot 4 of the proposed Chenal Valley Phase 2 Commercial Subdivision (S-867- EEEEE - Item #5). The applicant has indicated the station will include two 20,000-gallon tanks located on the southwest corner of the canopy. There will be eight fuel islands, and two of these islands will be for diesel fuel only. A large landscape berm is provided on the west side of the lot to help screen the lot from the residential area across Chenal Parkway. The applicant is proposing a dumpster that will be enclosed in brick with wooden doors with a maximum height of six feet. The canopy columns will be wrapped in the same type brick that is proposed for the Wal-Mart Super center. The proposed site plan includes the placement of a single location for dispensing air and water and a separate location for a phone booth. The applicant has indicated a single ground mounted sign located near the northern drive and a sign easement for the Wal-Mart signage on proposed Lot 4. The applicant has indicated wall signage to include a logo sign fronting Chenal Parkway and pricing information signage on the Chenal Parkway façade of the canopy. March 11, 2004 SUBDIVISION ITEM NO.: 17 (Cont.) FILE NO.: Z-5097-F 3 B. EXISTING CONDITIONS: The site has been cleared for construction for the Wal-Mart Super Center. Chenal Parkway, in this area, is a two-lane road and Cantrell Road is a four-lane road with a center turn lane at the intersection of Chenal Parkway and Cantrell Road. Other uses in the area include a Quick Stop Service Station on the northwest corner and mini-warehouses on the northeast corner of Chenal Parkway and Cantrell Road. The southwest corner is zoned C-3, General Commercial and is currently undeveloped. Vacant O-2 zoned property is located to the south of the site with OS zoned property located between the office zoning and the single- family residential located further southeast. South and west of the proposed development are also single-family residences adjoining vacant O-2 and C-2 zoned property across Chenal Parkway. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. All residents who could be identified located within 300-feet of the site, the Aberdeen Court Property Owners Association, the Bayonne Place Property Owners Association, the Margeaux Property Owners Association and the DuQuesne Place Property Owners Association and all owners of property located within 200-feet of the site were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Driveway locations and widths are acceptable. Left turns will be allowed in the northern most drive if the island is removed. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Entergy: Approved as submitted. Center-Point Energy: Approved as submitted. SBC: No comment received. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. Contact Central Arkansas March 11, 2004 SUBDIVISION ITEM NO.: 17 (Cont.) FILE NO.: Z-5097-F 4 Water regarding the size and location of the water meter. The meter location may be different than that shown on the plans. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. The existing waterline easement should be shown. No sign may be located within the existing waterline easement and in any case must be located at least 5 feet of the existing 16-inch water main. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Approved as submitted. County Planning: No comment received. CATA: No comment. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: Areas set aside for buffer and landscaping appear to meet with the landscape and buffer requirements. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) The applicant was present representing the request. Staff stated the request was to review placement of a building on a proposed lot currently zoned C-3, with conditions (site plan review). Staff requested the applicant provide additional information concerning the dumpster screening on the proposed site plan. Staff also requested the proposed sign easements be relocated outside the existing right-of-way and easements. Staff questioned the proposed retaining wall. The applicant stated the wall would be approximately 11 feet at the south end tapering to 0 at the north end. Staff questioned if the proposed phone would be visible from the street side. The applicant indicated it would not be visible. Staff also questioned if the lights from the canopy reflect downward. The applicant indicated due to elevations from the site and the parkway the lights would not reflect onto the parkway or to the adjoining homes. Landscaping comments were addressed. Staff noted the areas set aside for buffers appeared to meet minimum ordinance requirements. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. March 11, 2004 SUBDIVISION ITEM NO.: 17 (Cont.) FILE NO.: Z-5097-F 5 H. ANALYSIS: The applicant has submitted a revised site plan to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated screening for the dumpster as required by ordinance or at least two feet above the finished grade of the container. The applicant has also relocated the proposed sign easements outside the right-of-way and proposed easements as requested by staff. Staff is supportive of the proposed request. The applicant has submitted a zoning site plan review adhering to all requirements of the zoning ordinance with regard to signage, setbacks and landscaping. The applicant has indicated a single-ground mounted sign located near the northern drive of the lot. The sign proposed is a six-foot by six-foot sign somewhat less than signage allowed under the Chenal Parkway Design Overlay District. The applicant has also indicated wall signage adjacent to Chenal Parkway consistent with signage allowed in commercial zones. The applicant has indicated less than ten percent of the façade area will be covered with wall signage, consistent with wall signage allowed per the zoning ordinance. The proposed site plan indicates a 440 square foot kiosk for the sale of fuel. The applicant has indicated there will be sales of snacks and cigarettes from the site. The applicant has indicated parking for three cars on the proposed site plan. The typical minimum parking requirement for a 440 square foot retail establishment would be one space. The proposed parking appears adequate to meet the parking demand. The proposed site plan also indicates a location for air and water and a telephone booth. The proposed location should not be visible from the parkway due to terrain in the proposed location. The applicant is proposing the placement of a Murphy Oil Fueling Center with eight fuel islands, and two of the islands will be for diesel fuel only. The applicant has worked with Public Works staff to address concerns of circulation and access for ingress/egress to the site. To staff’s knowledge there are no outstanding issues associated with the proposed request. Staff feels if the site is developed as proposed there should be minimal to no adverse impact on the adjoining properties. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. March 11, 2004 SUBDIVISION ITEM NO.: 17 (Cont.) FILE NO.: Z-5097-F 6 PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were no registered objectors present. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented the item with a recommendation of approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 18 FILE NO.: Z-5097-G NAME: Wal-Mart Revised Zoning Site Plan Review LOCATION: On the Southeast corner of Cantrell Road and Chenal Parkway DEVELOPER: Wal-Mart Store, Incorporated 702 S.W. 8th Street Bentonville, AR 72716-0550 ENGINEER: Carlson Consulting Engineers 7731 Highway 70, Suite 210 Bartlett, TN 38133 CURRENT ZONING: C-3, with conditions – General Commercial District with site plan review. ALLOWED USES: General Commercial PROPOSED ZONING: C-3 PROPOSED USE: C-3, General Retail – Wal-Mart Super center VARIANCES/WAIVERS REQUESTED: A variance to allow an off premise sign. BACKGROUND: On December 20, 1988, the Board of Directors adopted Ordinance No. 15,603, which rezoned several tracts of land as a part of the Deltic Master Plan from Residential zoning to various multi-family, office and commercial zoning districts. That action rezoned 7.860 acres located at the southeast corner of Highway 10 and Chenal Parkway from R-2 to C-3. The approval of the C-3 zoning was conditioned upon a site plan review, by the Planning Commission, prior to development and a provision of a 40-foot landscaped setback adjacent to Highway 10 and the Chenal Parkway. Ordinance No. 16,459 rezoned additional properties contained within the proposed Wal-Mart site. The Ordinance was approved by the Board of Directors on July 20, 1993, and rezoned 8.7051 acres from R-2 to C-3, General Commercial. March 11, 2004 SUBDIVISION ITEM NO.: 18 (Cont.) FILE NO.: Z-5097-G 2 Ordinance No. 18,628, adopted by the Board of Directors on January 2, 2002, rezoned an additional 10.92 acres from R-2 to C-3, General Commercial. This area was to the south of the C-3 zoned property and adjacent to Chenal Parkway. At the time of rezoning the applicant also requested and was approved rezoning further south. The zoning approved was O-2 on 10 plus acres adjacent to the Parkway and 10 plus acres of OS zoning nearer the single-family neighborhood to the east. As a condition of the 1988 zoning, approximately six (6) acres of the site was subject to site plan review. The applicant submitted a proposed site plan for review by the Little Rock Planning Commission at their October 31,2002 Public Hearing. The Commission approved the proposed site plan with a modification to the pole height of the proposed lighting in the parking lot. The applicant intended to develop the 28.4 acres as a 210,396 square foot Wal-Mart Super center, associated parking and service areas. The parking lot consisted of 988 parking spaces, including 24 handicap accessible parking spaces. Two driveways were to provide access to the proposed project from Cantrell Road and two driveways from Chenal Parkway. The southernmost driveway on Chenal Parkway would align opposite the existing Northfield Drive and is proposed to be signalized. This drive would be a shared drive with the currently undeveloped property to the south (zoned O-2), thus helping to limit future access points on the Parkway. Improvements would be provided on Chenal Parkway and Cantrell Road as coordinated with the City of Little Rock. The development was to be buffered from surrounding developments by the required landscape buffer areas and internal landscaping. Additionally, the storm water detention area was proposed to be located to the east of the building within the existing Entergy easement. The addition of low height landscaping within the clear-cut area would provide a visual enhancement to the Highway 10 Corridor. The placement of the landscaping would provide a significant buffer to those properties lying to the east of the development. Additionally, the OS zoned area to the south of the property would provide a substantial buffer immediately south of the proposed Wal-Mart building. By orienting the building to face Chenal Parkway, the building was located at the furthest possible distance from those properties to the west and southwest of the development. A. PROPOSAL/REQUEST: The applicant is now proposing to revise the previously approved Wal-Mart site plan to remove a portion of the previously approved site plan and create a total of four lots (Item No. 5 – File No. S-867-EEEEE), three related to the Wal-Mart site and ownership. The applicant has indicated drives for ingress and egress will remain as previously approved by the Commission on October 31, 2002. The applicant has also indicated there will be no change in required buffer areas or areas set-aside for landscape. The applicant is requesting a variance to allow the placement of an off premise sign. The sign is located on Lot 4 of the March 11, 2004 SUBDIVISION ITEM NO.: 18 (Cont.) FILE NO.: Z-5097-G 3 proposed Chenal Valley Phase 2 Commercial Subdivision Revised Preliminary Plat (Item No. 5 – File No. S-867-EEEEE). B. EXISTING CONDITIONS: The site has been cleared for construction of the Wal-Mart Super Center. Chenal Parkway, in this area, is a two-lane road and Cantrell Road is a four-lane road with a center turn lane at the intersection of Chenal Parkway and Cantrell Road. Other uses in the area include a Quick Stop Service Station on the northwest corner and mini-warehouses on the northeast corner of Chenal Parkway and Cantrell Road. The southwest corner is zoned C-3, General Commercial and is currently undeveloped. There is an Entergy easement along the east property line with a church located further to the east of the site. Vacant O-2 zoned property is located to the south of the site with OS zoned property located between the office zoning and the single-family residential located further south and east of the proposed development. South and west of the proposed development are also single-family residences adjoining vacant O-2 and C-2 zoned property. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. The Aberdeen Court Property Owners Association, the Bayonne Place Property Owners Association, the Margeaux Property Owners Association, the Maywood Manor Neighborhood Association and the DuQuesne Place Property Owners Association and all owners of property located within 200-feet of the site were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. No comment on revised site plan showing two additional out-parcel lots. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Entergy: Easements required. Contact Entergy for additional details. Center-Point Energy: Approved as submitted. SBC: No comment received. March 11, 2004 SUBDIVISION ITEM NO.: 18 (Cont.) FILE NO.: Z-5097-G 4 Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Approved as submitted. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: All previous comment apply. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Mike Dedman was present representing the request. Staff gave an overview of the proposed development indicating the proposed site plan was being submitted to remove the area designated as Lots 3 and 4 (S-867-EEEEE – Item #5) from the previously approved site plan. The proposed revision to the Wal-Mart site was discussed with the proposed preliminary plat. Staff noted there were few outstanding issues related to the proposed Wal-Mart site plan and requested notification of property owners as required by the Planning Commission By-Laws. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plan to Staff addressing most of the issues raised at the Subdivision Committee meeting. As a part of the previous approval the applicant has provided a copy of the lease agreement between Entergy indicating the use of the eastern fifty feet of the Entergy right-of-way. The agreement states “vegetation growth may not exceed 12-feet in height” and that “Entergy and its successors will not cut any trees, plants or natural vegetative growth within the Green Belt Buffer if such would result in the buffer not being in compliance with the applicable buffer ordinance of the City of Little Rock”. March 11, 2004 SUBDIVISION ITEM NO.: 18 (Cont.) FILE NO.: Z-5097-G 5 As was previously approved the applicant has indicated interior islands of the parking area will conform to the three hundred (300) square feet area requirement. The applicant has indicated access will be provided to the previously platted lot (Lot 1 Chenal Valley Phase II Commercial Subdivision). The drive will be located adjacent to Lot 1 and the Wal-Mart development will not take access from this drive. The applicant is proposing two ground-mounted signs. One is to be located at the intersection of Chenal Parkway and Northfield Drive the second near the primary drive from Cantrell Road. The sign proposed for Northfield Drive is proposed at forty (40) square feet in area, well within the Chenal Overlay District requirements for signage (maximum of eight (8) feet in height and one hundred (100) square feet in area). The site will be located in a sign easement on Lot 4 of the proposed preliminary plat area (S-867-EEEEE – Item #5). The sign proposed along Cantrell Road is proposed at six (6) feet in height and seventy- two (72) square feet in area, complying with the Highway 10 Design Overlay District requirements. Site lighting has been addressed. The applicant has indicated 400-watt metal halide fixtures on 30-foot black steel poles will provide site lighting. The applicant states fixtures shall contain all horizontal bulbs with flat lenses to control glare and over spill of lighting. The site plan states lights will be directed away from adjoining properties and no floodlights will be used. The applicant has indicated 988 parking spaces as part of the development. The typical minimum parking required would be 701 spaces. The proposed parking is more than sufficient to meet the typical minimum parking required by the Zoning Ordinance. The applicant has indicated all comments provided by Public Works will be adhered to. The Traffic Engineer has determined road improvements will be required as a part of the development. Chenal Parkway is to be widened to a four (4)-lane roadway at the point when the traffic counts reach 12,000 cars per day. A traffic signal will be installed at the intersection of Chenal Parkway and Cantrell Road in the near future. The landscaping, building setbacks and signage conform to all provisions of the Chenal Overlay District and the Highway 10 Overlay District. Otherwise, to Staff’s knowledge, there are no outstanding issues associated with the proposed site plan review. Staff is supportive of the proposed site plan and feels the applicant has met the intent of the ordinance with regard to setbacks, buffer requirements, landscaping requirements, parking ratios and all other technical aspects of the ordinance. March 11, 2004 SUBDIVISION ITEM NO.: 18 (Cont.) FILE NO.: Z-5097-G 6 I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff recommends approval of the requested variance to allow an off premise sign for the proposed development. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were no registered objectors present. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented the item with a recommendation of approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff also presented a recommendation of approval of the requested variance to allow an off premise sign for the proposed development. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 19 FILE NO.: Z-3173-C NAME: Sage Meadows Long-form PD-R LOCATION: On the West side of John Barrow Road, South of Tanya Drive DEVELOPER: WTH Development 8503 Asher Avenue Little Rock, AR 72204 ENGINEER: Roberts and Williams Associates Landscape Architects 1501 North University Avenue Little Rock, AR 72207 AREA: 21 Acres NUMBER OF LOTS: 56 FT. NEW STREET: 2910 L.F. CURRENT ZONING: MF-12 ALLOWED USES: Multi-family Residential at a density of 12 units per acre PROPOSED ZONING: PD-R PROPOSED USE: Single-family residential at 2.66 units per acre – 56 units VARIANCES/WAIVERS REQUESTED: None requested. BACKGROUND: The applicant previously proposed to construct 34 buildings of multi-family housing on a 25.57 acre property located on the west side of John Barrow Road, just south of Tanya Drive. The site was zoned MF-12 (Multi-family Residential – 12 units per gross acre). The west 110 feet of the property ownership was left as R-2 zoning, when the remainder of the property was zoned, to serve as a buffer between this site and the single-family property to the west. March 11, 2004 SUBDIVISION ITEM NO.: 19 (Cont.) FILE NO.: Z-3173-C 2 The applicant proposed to develop multi-family residences on the site. The density proposed was under the twelve units per gross acre as allowed by the City’s Zoning Ordinance. The request was to be heard by the Planning Commission at their January 21, 1999 Public Hearing but was withdrawn by the applicant prior to the Public Hearing. On May 3, 1994, the Little Rock Planning Commission approved a Conditional Use Permit to allow Four Oaks Living Center to locate on the northeast portion of the site. The facility was to be constructed with a 140 bed facility and is held under a separate ownership. A. PROPOSAL/REQUEST: The applicant is now proposing to develop this 34-acre site in a two-part development. The site is currently zoned MF-12 which allows for the development of multi-family housing at a density of 12-units per acre. The applicant has indicated a desire to develop 20.64 acres as a Planned Residential Development for single-family homes and the remaining 13.16 acres as a multiple building multi-family residential development (S-1229-A – Item #15). The applicant has indicated the development of the PRD portion of the site with 56 units of single-family homes. The proposed site plan includes signage for both the single-family subdivision and the multi-family development. Signage will be located near the drive into the multi-family development and at the entrance to the single-family subdivision. The proposed site plan includes a clubhouse, two lakes and two play ground recreational spaces. The development also contains a series of pedestrian trails connecting the multi-family and the single-family development. The clubhouse and pool will be developed as a part of a property owners association through the Planned Residential development allowing both the single-family homes and the multi-family residents access to the facilities. B. EXISTING CONDITIONS: The site is vacant and tree covered sloping from the north and south to the center of the site. There is a developed nursing home located at the northeast corner of the site. Park View High School is located to the north east of the site and single-family homes are located to the southeast. To the south of the site is an area zoned MF-24 with a welding shop and a separate building containing a contractor’s office. Single-family homes are located along West 29th Street to the south of the site. To the west of the site are also single-family homes in the Twin Lakes/Campus Place Neighborhood. March 11, 2004 SUBDIVISION ITEM NO.: 19 (Cont.) FILE NO.: Z-3173-C 3 C. NEIGHBORHOOD COMMENTS: As of this writing, staff has received several phone calls in opposition of the proposed use from area residents. All residents who could be identified located within 300-feet of the site, the John Barrow Neighborhood Association, the Campus Place Property Owners Association, the Twin Lakes “B” Property Owners Association, Twin Lakes B Special Improvement District and all owners of property located within 200-feet of the site were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. The proposed street from John Barrow going west to the last apartment entrance should be designed as a 36 foot collector street. The remainder can be 31 foot as shown on the plan. 2. Provided curve data for the collector street. The standard radius for a normal crown is 275 feet with a 100-foot tangent between reverse curves. 3. The residential street curve radius at the northwest corner of the development does not meet the standard 150-foot radius. 4. Monique Drive was originally planned to connect through to John Barrow. The connection should be shown on the plat. 5. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Site grading, and drainage plans will need to be submitted and approved prior to the start of construction. 6. Show the location and preliminary sizing for all storm drains. Easements must be provided for all storm drains. Assuming the 0.48-acre lake will serve as detention for the residential subdivision, easements are likewise required for that drainage. 7. Prepare a letter of pending development addressing streetlights as required by Section 31-403 of the Little Rock code. Contact Traffic Engineering at (501) 379-1813 (Steve Philpott) for more information regarding street light requirements. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Private sewer main crossing property. Must be relocated and dedicated to Little Rock Wastewater Utility as a public sewer main with easements. Capacity Contribution Analysis required, contact Little Rock Wastewater Utility at 688-1414 for additional details. March 11, 2004 SUBDIVISION ITEM NO.: 19 (Cont.) FILE NO.: Z-3173-C 4 Entergy: No comment received. Center-Point Energy: Approved as submitted. SBC: No comment received. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. The facilities on-site in the area of the apartments will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. A water main extension will be required in order to provide service to this property. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional details. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: This request is located in the I-430 Planning District. The Land Use Plan shows Low Density Residential for this property. The applicant has applied for a Planned Residential Development for a new single-family subdivision. The request does not require a change to the Land Use Plan. The total density calculated for the proposal falls within the 6 - 10 dwelling unit per acre range of the LDR category. City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the John Barrow Neighborhood Action Plan. The Housing and Neighborhood Revitalization goal lists an objective of reviewing the appropriateness of existing zoning classifications. The action statement recommends that existing zoning classifications be reviewed to determine if the classifications compromise the interest to revitalize or stabilize housing in the area. Landscape: No comment. March 11, 2004 SUBDIVISION ITEM NO.: 19 (Cont.) FILE NO.: Z-3173-C 5 G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Barry Williams was present representing the request. Staff stated there were two items related to the site zoned MF-12, one a single-family development, the second a multi-family site plan review. Staff stated the two items were reviewed separate and would be discussed together. Staff noted there were additional items necessary on each item to complete the review process. Staff first requested additional information for the site plan review. Staff requested the applicant provide details of signage, fencing and a phasing plan, if applicable. The staff also requested the applicant provide the lot size and total building coverage in the general notes section of the site plan. Mr. Williams noted the proposed multi-family units would be constructed as split-level units to better adhere to the terrain. Mr. Williams stated the maximum building height would be 35-feet. Staff requested the applicant provide maximum building height, front yard building lines and total buildable areas for the proposed PRD portion of the development. Staff stated since the request was a PRD there were no setbacks except those imposed at the time of approval. Staff requested the applicant provide details of any proposed signage associated with the new single-family development. Staff requested the applicant provide details concerning lot sizes and the source of water and the means of wastewater disposal. Public Works comments were addressed. Staff stated the proposed street extending west from John Barrow Road should be designed to a 36-foot collector street. Mr. Williams stated the desire of the developers was to narrow the streets to reduce speeds. Staff stated they could support the reduced standard in the single-family portion of the development but the street adjacent to the multi-family should be wider. The proposed site plan does not connect Monique Drive through the development to John Barrow Road. Staff and the applicant agree it is better for the connection not to be made to reduce cut-through traffic and enhance the overall development. The applicant has also requested the street at the northwest corner of the development not meet the 150-foot radius requirement. The applicant has indicated this will enhance the development as well by acting as a traffic calming device and slowing traffic through the area. Staff questioned the watercourse proposed on the site plan. Staff stated the storm water detention ordinance would apply to the site. Staff stated a wider drainage easement for the lake to John Barrow Road right-of-way would be required. Mr. Williams stated the desire was to allow the lake to serve as detention as well as a water feature. March 11, 2004 SUBDIVISION ITEM NO.: 19 (Cont.) FILE NO.: Z-3173-C 6 Landscaping comments were addressed for the apartment site. Staff noted there would not be any landscaping required for the PRD (single-family) portion of the development. Staff noted the areas set aside for buffering appeared to meet the landscape ordinance requirements. Staff also noted screening would be required along the southern perimeter where the site adjoined single-family zoned property. There were no further items for discussion. The Committee then forwarded each item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plan to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated the maximum build areas of the single-family development. The applicant has indicated a 25-foot front building line and eight foot side yard setbacks. The applicant has also indicated a 25-foot rear yard setback. The applicant has indicated the maximum building height of 35-feet. The setbacks and building height are consistent with typical minimum requirements of the Subdivision Ordinance for platting of single-family zoned property. The applicant has also indicated the minimum lot size as 66-feet by 125-feet or 8250 square feet, more than adequate to meet the typical minimum lot size square footage. The applicant has indicated the clubhouse to be included in the planned development. The clubhouse, and a recreational area are included in Tract “C” of the development. The applicant has indicated a property owners association will be established to maintain the tracts and the clubhouse. The applicant has indicated both the single-family and the multi-family will have access to these amenities. The applicant has also included pedestrian trails through out the development connecting the single-family and the multi-family portion of the proposed development. The applicant has indicated a single subdivision sign to be located near the entrance to the proposed single-family subdivision. This sign will comply with signage allowed for single-family subdivision or not to exceed thirty-two square feet in sign area and six feet in height according to the applicant. The applicant has indicated there is not a Bill of Assurance in effect for the proposed property. A final plat for the site has never been filed. Staff is supportive of the proposed development. Staff feels with the overall development plan, the development of single-family and multi-family in an intergraded neighborhood the development should be successful due the mixture of residential uses. The applicant has also included amenities for the overall March 11, 2004 SUBDIVISION ITEM NO.: 19 (Cont.) FILE NO.: Z-3173-C 7 development to provide recreational activities for the residential and the multi-family uses. The applicant has exceeded the minimum requirements of the ordinance and staff feels if the development is constructed as proposed including the single-family portion of the development there should be minimal to no adverse impact on adjoining properties. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff recommends the curve radius for the street at the northwest corner of the development meet the standard 150-foot radius. Any fencing construction through the PD-R shall comply with ordinance standards for single-family zoning. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were several registered objectors present. Staff presented the item along with a related site plan review (Item # 15 – File No. S-1229-A) indicating support for the rezoning request and the site plan review request. Staff stated they were supportive of reducing the rear radius to 75-feet and narrowing the street to 31-feet of pavement. Staff stated the applicant had indicated the request for the reduced standard was to act as a traffic calming device and the reduced street standard would comply with minor residential street standards. Mr. Barry Williams addressed the Commission on behalf of the applicant. He stated the desire of the development was to develop the site with a mix of single-family and multi- family units. He stated the proposed development included a clubhouse and pool area that would be shared by the apartment dwellers as well as the single-family homeowners. He stated the development also included a series of trails and pathways to connect the two developments and allow for integration of the neighborhood. Ms. Carolyn Heitman addressed the Commission in opposition of the proposed development. She stated the Barrow Road Neighborhood was not in support of the proposed development. Ms. Heitman stated traffic was the primary concern of the Neighborhood Association. She stated the desire was to allow the area to develop with less intense uses. Ms. Heitman stated the John Barrow Road Neighborhood Association had met with the developers but the other Association’s in the area had not met with the developers. She requested the Commission defer the item until the developer had met with all the affected neighborhoods and the neighborhoods had the opportunity to discuss the potential project. March 11, 2004 SUBDIVISION ITEM NO.: 19 (Cont.) FILE NO.: Z-3173-C 8 Mr. George Brown addressed the Commission in opposition of the proposed request. He stated the neighborhood did not want additional apartments. He stated the area currently had 1000 plus apartments which were not fully occupied. He stated traffic was currently a nightmare and the addition of more apartments would only compound the problem. Ms. Francis Harris-Waddell addressed the Commission in opposition of the proposed request. She stated the neighborhood located to the west of the site had signed a petition, which had been given to the Commission. She stated the petition contained 100 percent of the homeowners, which would be directly affected by the proposed development. Ms. Waddell stated apartments would have a devastating effect on the single-family homes in the area. Commissioner Rector stated the discussion was not related to the apartments. He stated the site was zoned for multi-family housing and the proposed development had met all the minimum requirements of the subdivision ordinance for a site plan review. He stated the Commission had no choice but to approve the proposed apartment development. He stated the Commission could discuss the single-family portion of the request which was a rezoning request to down zone approximately two-thirds of the site. Ms. Waddell questioned the square footage of the homes, the estimated sales price, the number of bedrooms and if the homes would have garages. Mr. Brad Norris of the Campus Place Neighborhood Association addressed the Commission in opposition of the proposed request. He stated his neighborhood had not had the opportunity to meet with the developers and discuss the proposed site plan. He requested the Commission defer the item until all the affected neighborhoods had the opportunity to meet with the developers. Chairman Mizan questioned the concerns of the neighborhood. He asked if they were related to issues raised by Ms. Waddell. Mr. Norris stated those were a few of the issues. He stated others were related to landscaping, buffering, detention, and building design. Mr. Kevin Howard, the applicant, addressed the Commission to answer questions related to the proposed development. He stated the homes would be two to four bedroom homes and range in size from 1,100 square feet to 1,800 square feet. He stated the estimated sales price was from $100,000 to $140,000. He stated the lots averaged in size from 8,200 square feet to 11,000 square feet. He stated the development would establish a homeowners association to ensure the green spaces and clubhouse were maintained properly. March 11, 2004 SUBDIVISION ITEM NO.: 19 (Cont.) FILE NO.: Z-3173-C 9 There was a general discussion concerning the drainage, detention and the proposed lake areas. There was also a general discussion concerning the placement of sidewalks within the proposed development. The applicant indicated sidewalks and trails would be used through out the development to allow for connectivity. Mr. Williams stated the request was to allow the clubhouse within the planned development portion of the request. He stated the apartments would be developed in two phases with seven buildings being constructed in the first phase and six buildings in the second phase. He stated the clubhouse and pool would also be constructed in the first phase to ensure the development of the single-family portion of the site. He stated once the PRD was established the developer would have no choice but to construct the single-family portion of the development or return to the Commission for a rezoning. There were questions related to the street and the narrowness of the proposed street. Staff stated the proposed development would handle less than 1300 cars per day, much less than a standard residential street. Staff stated the narrow street was acceptable and the curves and radius, if increased to 75-feet, would also be acceptable. Commissioner Adcock questioned if no parking signs would be available. Staff stated parking would typically be allowed on one side of the street. Mr. Williams stated if Public Works required three lanes at the intersection this would not be an issue. He stated the right-of-way would be in place to allow a 36-foot street at the intersection. There was a general discussion concerning the proposed management of the apartment development. Mr. Howard stated the developers had not executed a contract but were interviewing potential management firms. He stated two were local firms. Chairman Mizan stated a condition of the approval would be the developer meet with the neighborhood prior to the Board of Directors meeting. A motion was made to approve the requested rezoning as amended. The motion carried by a vote of 8 ayes, 1 noe and 2 absent. March 11, 2004 ITEM NO.: 20 FILE NO.: Z-3459-H NAME: Home Depot – Revised Conditional Use Permit LOCATION: Mabelvale Plaza at I-30 OWNER/APPLICANT: Home Depot USA, Inc./Greenberg Farrow Architecture PROPOSAL: A revision to Home Depot’s previously approved conditional use permit is requested to allow for the removal of a portion of a 50 foot wide land use buffer along the site’s western perimeter. PUBLIC NOTIFICATION: All owners of property located within 200 feet of the site, all residents within 300 feet who could be identified and the SWLR United for Progress, Pinedale and Mavis Circle Neighborhood Associations were notified of the request. SUBDIVISION COMMITTEE COMMENT: (FEBRUARY 19, 2004) The applicant was present. Staff presented the item and noted the plan needed to be modified to more clearly show the proposed new property line, the location of the Home Depot sign and the width of the remaining landscape strip on the western perimeter. There were no other issues. The Committee forwarded the item to the full Commission. STAFF REPORT: On April 3, 2003, the Planning Commission approved a conditional use permit allowing Home Depot to construct a new home center on this C-3 zoned 12± acre tract. The approved development included a 102,513 square foot building, 34,643 square feet of garden center and 426 parking spaces. Parking has since been expanded to 458 spaces. At the time of the original approval, the properties adjacent to the west (between Home Depot and Mabelvale Pike) were all zoned R-2 Single Family. Home Depot was required to place a 50-foot wide buffer and a 6 foot tall screening fence along its west perimeter where adjacent to the residential properties. Since that date, some of the adjacent properties have been rezoned to C-3. A preliminary plat application has been filed to subdivide those adjacent properties into new commercial lots. A portion of the Home Depot property is proposed to be added to the new lots through this plat. See file No. S-993-K, Mabelvale March 11, 2004 SUBDIVISION ITEM NO.: 20 (Cont.) FILE NO.: Z-3459-H 2 Business Park and Shopping Center revised preliminary plat, which is also on this agenda. Home Depot is requesting approval of a revision to its C.U.P., allowing up to 40 feet of the western buffer to be eliminated and that area to be removed from the Home Depot site and added to the new lots. The proposed change only affects the portion of the Home Depot site which is adjacent to the C-3 zoned properties. The required buffer and screening will remain in place where the adjacent properties are zoned R-2. Staff is supportive of the revision. Since the adjacent properties are now zoned C-3, no land use buffer or screening are required. A 10-foot wide landscape strip will remain along the affected portion of the Home Depot site; exceeding the Landscape Ordinance minimum requirement of a 9 foot strip. On February 25, 2004, the applicant submitted a revised site plan clearly showing the new property line, landscape strip and sign location. All comply with Ordinance standards. To staff’s knowledge there are no outstanding issues. STAFF RECOMMENDATION: Staff recommends approval of the requested revision subject to compliance with the conditions previously required when the C.U.P. was originally approved on April 3, 2003 (Z-3459-F). PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was not present. There were no objectors present. Staff informed the Commission that the applicant had failed to send the required notices and the item needed to be deferred. There was no further discussion. The item was placed on the Consent Agenda and approved for deferral to the March 25, 2004 Commission meeting. The vote was 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 21 FILE NO.: LU04-12-01 Name: Land Use Plan Amendment - 65th Street - West Planning District Location: Southeast Corner of Col. Glenn and Shackleford Roads Request: Light Industrial to Commercial and Service Trades District Source: Kevin Huchingson, Dickson Flake & Partners The applicant has petitioned to defer this item to the April 22, 2004 Planning Commission Meeting. Staff recommends placing this item on the consent agenda for deferral. PLANNING COMMISSION ACTION: (March 11, 2004) The item was placed on the consent agenda for deferral to the April 22, 2004 Planning Commission meeting. A motion was made to approve the consent agenda and was approved with a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 21.1 FILE NO.: Z-5703-A NAME: Shackleford Commercial Long-form PCD LOCATION: On the Southeast corner of Colonel Glenn Road and Shackleford Road DEVELOPER: Shackleford and Colonel Glenn LLC c/o Dickson Flake Partners P.O. Box 3546 Little Rock, AR 72203 ENGINEER: White-Daters and Associates #24 Rahling Circle Little Rock, AR 72223 AREA: 11.4 Acres NUMBER OF LOTS: 2 FT. NEW STREET: 0 CURRENT ZONING: R-2, Single-family ALLOWED USES: Non-conforming commercial use and single-family residential PROPOSED ZONING: PCD and C-3 PROPOSED USE: General Commercial and Office/Showroom/Warehouse VARIANCES/WAIVERS REQUESTED: None requested. The applicant submitted a letter dated February 25, 2004, requesting this item be deferred to the April 22, 2004 Public Hearing. Staff is supportive of this request. PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Joe White was present representing the request. There were no registered objectors present. Staff stated the applicant had submitted a letter dated February 25, 2004, requesting the item be deferred to the April 22, 2004 Public Hearing. Staff stated they were supportive of the request. March 11, 2004 SUBDIVISION ITEM NO.: 21.1 (Cont.) FILE NO.: Z-5703-A 2 There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 22 FILE NO.: Z-6219-A NAME: Bella Rosa Drive Long-form PCD LOCATION: On the Southwest corner of Cantrell Road and Bella Rosa Drive DEVELOPER: HWY 107 Associates, LLC 3801 Woodland Heights Little Rock, AR 72212 ENGINEER: McGetrick and McGetrick Engineers 319 President Clinton Avenue, Suite 202 Little Rock, AR 72201 AREA: 7.5 Acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 CURRENT ZONING: R-2, Single-family ALLOWED USES: Single-family residential PROPOSED ZONING: PCD PROPOSED USE: Office/Warehouse – Mini-warehouse development VARIANCES/WAIVERS REQUESTED: None requested. BACKGROUND: The Planning Commission previously reviewed and denied a request to rezone the site from R-2, Single-family to POD to allow the site to develop with limited office space, conditioned storage and mini-storage. The proposal included the placement of 102,775 square feet of improvements, containing approximately 18,000 square feet of office and office/warehouse space, including an on-site manager’s office and apartment comprising approximately 1,600 square feet. The balance of the project was to be self-storage units. March 11, 2004 SUBDIVISION ITEM NO.: 22 (Cont.) FILE NO.: Z-6219-A 2 The applicant proposed the perimeter of the two buildings located adjacent to Cantrell Road to be constructed of “drivet” wall system over a steel super structure mixed with glass office front. The roof system was to be a flat roof hidden behind a metal parapet. The self-storage units were proposed as metal system over a steel structure with access provided by overhead doors. A. PROPOSAL/REQUEST: The site contains 7.5 acres located on the southwest corner of Cantrell Road and Bella Rosa Drive. The applicant intends to develop the site with a total of 82,800 square feet of office/retail and mini-warehouse buildings. The site will contain a single building of office/retail containing a total of 29,000 square feet and an office/managers residence for the mini-warehouse development. A second building will contain 28,000 square feet of conditioned storage accessed from interior halls. There are three buildings of stand-alone mini-warehouse buildings containing a total of 25,800 square feet of space. The total building coverage proposed is 34.3 percent with 27 percent of the site designated as landscaped/green space area. The site contains 117 parking spaces with 19 spaces proposed for boat and RV storage. The applicant has indicated the days and hours of operation from 7 am to 8 pm seven days per week. The mini-warehouse will have 24-hour access. B. EXISTING CONDITIONS: The site is vacant with trees around the perimeters of the property. The site is relatively flat with a creek running along the western and southern perimeters. The property to the east of the site (across Bella Rosa Drive) is vacant and has been cleared. Further to the west is the Seven Acres Business Park zoned POD and developed with a mix of commercial and office uses. To the southeast are single-family homes adjoining the northern bank of the creek. To the south of the site (across the creek) are vacant lands and single-family homes fronting Bella Rosa Drive. To the west of the proposed site (west of the creek) are also vacant lands fronting Cantrell Road. North of the site are single-family homes on large acreages. Cantrell Road is a four-lane roadway with a center turn lane. There are no sidewalks in place fronting the site. Bella Rosa Drive is a narrow unimproved roadway with open ditches for drainage and no sidewalks. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. All residents who could be identified located within 300-feet of the site, the March 11, 2004 SUBDIVISION ITEM NO.: 22 (Cont.) FILE NO.: Z-6219-A 3 Westchester/Heatherbrae Neighborhood Association, Secluded Hills Property Owners Association, Charleston Height/North Rahling Road Neighborhood Association and all owners of property located within 200-feet of the site were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. The proposed land use would classify Bella Rosa Drive on the Master Street Plan as a commercial street. Dedicate right-of-way to 30 feet from centerline. 2. Cantrell Road is classified on the Master Street Plan as a principal arterial. A minimum dedication of right-of-way to 55 feet from centerline will be required. Ten feet additional right-of-way will be required for a right turn lane. 3. A 20 feet radial dedication of right-of-way is required at the intersection of the streets. 4. Provide design of street conforming to the Master Street Plan. Construct one-half street improvement to these streets including 5-foot sidewalks with the planned development. This would include a standard right turn lane on Cantrell, and construction to collector standards on Bella Rosa. 5. A special Grading Permit for Flood Hazard Areas will be required per Section 8-283 prior to any land clearing or grading activities at the site. Site grading, and drainage plans will need to be submitted and approved prior to the start of construction. 6. In the floodplain, the minimum Finish Floor elevations will be required to be shown on plat and grading plans. 7. In accordance with Section 31-176, floodway areas must be shown as floodway easements or be dedicated to the public. In addition, a 25-foot wide access easement is required adjacent to the floodway boundary. 8. Storm water detention ordinance applies to this property. Show the proposed location for storm water detention facilities on the plan. 9. Prepare a letter of pending development addressing streetlights as required by Section 31-403 of the Little Rock code. Contact Traffic Engineering at (501) 379-1813 (Steve Philpott) for more information regarding street light requirements. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Entergy: A 15-foot Entergy easement is required. Contact Entergy at March 11, 2004 SUBDIVISION ITEM NO.: 22 (Cont.) FILE NO.: Z-6219-A 4 954-5158 for additional information. Center-Point Energy: Approved as submitted. SBC: Approved as submitted. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. The facilities on-site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. A Capital Investment Charge based on the size of the connection(s) will apply to this project in addition to normal charges. This fee will apply to all meter connections including any metered connections off the private fire system. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZA) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact Carroll Keatts at 992-2431 if you would like to discuss backflow prevention requirements for this project. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Maintain a 20-foot access and a 20-foot gate opening. Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional details concerning turning radius. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: This request is located in the Chenal Planning District. The Land Use Plan shows Transition for this property. The applicant has applied for a Planned Commercial Development for offices and mini-warehouses. March 11, 2004 SUBDIVISION ITEM NO.: 22 (Cont.) FILE NO.: Z-6219-A 5 The request does not require a change to the Land Use Plan. However, the development needs to occur at a small scale and intensity low enough to minimize the impact of development on neighboring properties. City Recognized Neighborhood Action Plan: The property under review is not located in an area covered by a City of Little Rock recognized neighborhood action plan. Landscape: If sufficient vegetation exists along the floodway (western perimeter of the site) that would satisfy the year around screening requirement, additional evergreen plantings or a 6-foot high wooden fence requirement may be wavered, should this area be shown to be preserved. However, a six (6) foot high opaque screen, either a wall, or wooden fence with its face side directed outward, or dense evergreen plantings, is required if insufficient vegetation exists in the floodway area. The proposed interior landscaping falls short of the eight percent landscaping requirement. This is a requirement of the landscape ordinance. Interior islands should be generally distributed throughout the vehicular use area. Landscape islands are to be a minimum of 150 square feet in area and a minimum width of seven and one-half feet. Building landscaping cannot count towards fulfilling interior landscaping requirements. An automatic irrigation system to water landscaped areas will be required. Prior to a building permit being issued, it will be necessary to provide an approved landscape plan stamped with the seal of a Registered Landscape Architect. The City Beautiful Commission recommends preserving as many existing trees as feasible on this tree-covered site. Credit toward fulfilling Landscape Ordinance requirements can be given when properly preserving trees of six (6) inch caliper or larger. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Pat McGetrick was present representing the request. Staff presented an overview of the request stating the request was a Planned Commercial Development to allow the site to develop with an office/warehouse development and mini-warehouse units on the rear. Staff requested Mr. McGetrick provide additional information to complete the review process. Staff requested additional March 11, 2004 SUBDIVISION ITEM NO.: 22 (Cont.) FILE NO.: Z-6219-A 6 information concerning signage, fencing and proposed dumpster location. Staff also requested information concerning any proposed outdoor storage. Staff stated they would recommend limiting the proposed uses of the office/warehouse building to O-3 uses with the ten percent accessory uses listed in the O-3 zoning district. Public Works comments were addressed. Staff stated a dedicated easement would be required adjacent to the floodway. Staff also stated a grading permit for flood hazard area would be required prior to development. Staff requested the applicant provide the minimum finished floor elevation for the proposed buildings. Landscaping comments were addressed. Staff noted the proposed building landscaping was not sufficient to meet the ordinance requirement. The perimeter buffer requirement was discussed. Mr. McGetrick stated there was a 150-foot natural area adjoining the creek. Staff stated the buffer would be required to provide year around screening. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plan to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated the proposed signage will be located in the front yard area near the intersection of Cantrell Road and Bella Rosa Drive and will be consistent with signage allowed in the Highway 10 Design Overlay District or a single ground mounted monument style sign a maximum of ten feet in height and one hundred square feet in area. Staff is supportive of the requested signage. The applicant has also indicated the location of the proposed dumpster and indicated the dumpster will be screened as required by the current Zoning Ordinance (on a minimum of three sides at least two feet above the finished container height). The applicant has indicated an eight-foot chain link fence along the southern and western property lines adjacent to the creek. The applicant has indicated the building will be used as screening on the street side of Bella Rosa Drive. The buildings will be single story and constructed of decorative block to enhance the development and provide security to the site. The remainder of the site will also be constructed of split face block. The development is proposed with a flat roof hidden by a parapet. The applicant has indicated the development will be constructed to give an office appearance. March 11, 2004 SUBDIVISION ITEM NO.: 22 (Cont.) FILE NO.: Z-6219-A 7 Staff is supportive of the proposed fencing and screening of the eastern property line. The rear of the site will be gated, limiting access to the mini-warehouse development. The gate will maintain a minimum of twenty-feet of opening to allow access by the Little Rock Fire Department. The proposed site plan indicates nineteen parking spaces designated for parking of boat and RV storage. The proposed location is at the rear of the site adjacent to the designated floodway. The proposed location will have little to no visibility from Cantrell Road and will be screened by the proposed buildings from Bella Rosa Drive. Staff is supportive of the limited placement of nineteen parking spaces for boat and RV storage on the site. The applicant has indicated the minimum floor elevation will be set above the 100-year floodplain. The applicant has also indicated a dedication of a twenty- five foot easement adjacent to the floodway as required by existing city ordinances. The applicant has indicated additional building landscaping to meet the minimum requirements of the Landscape Ordinance. The applicant has indicated a forty-foot landscape buffer along Cantrell Road and a one hundred foot building line to satisfy the Highway 10 Design Overlay District requirements. The proposed site plan indicates 117 parking spaces and 98 designated for customer parking. The proposed site would typically require seventy-two parking spaces for the office/retail building based on the typical parking required for an office development or one space per four hundred square feet of gross floor area. The mini-warehouse development would typically require thirty-two parking spaces or six spaces plus one space per two thousand square feet of gross floor area. The total typical parking required would be one hundred eight parking spaces. Staff feels the proposed parking is adequate to meet the proposed parking demand of the development. Mini-warehouse developments typically do not generate a great parking demand and most customers are parking at their individual unit loading and unloading belongs. Staff recommends the applicant limit the development of the office/retail building to O-3 uses and the selected accessory uses, limited to ten percent of the gross floor area. The site is shown on the City’s Future Land Use Plan as Transitional, which allows for development of residential and office uses. Staff feels even though the site is proposed as a PCD limiting the commercial, the mini-warehouse portion of the development, to the rear and screened by the office uses to the front, the development will maintain an overall office feel. The applicant has indicated through building elevations the rear of the site will be screened and none of the commercial uses will be visible from Cantrell Road. March 11, 2004 SUBDIVISION ITEM NO.: 22 (Cont.) FILE NO.: Z-6219-A 8 Only through this scenario does staff feel comfortable allowing this development to locate on this site. The applicant has indicated there is not a Bill of Assurance in effect for the proposed site. Otherwise, to staff’s knowledge, there are no outstanding issues related to the proposed development. The proposed development if developed with office uses located along the roadways and commercial uses on the interior of the site should have minimal to no adverse impact on adjoining properties. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the staff report. Staff recommends the 29,000 square foot office/retail building be limited to O-3 uses and ten percent of the total square footage utilized by the listed O-3 accessory uses. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were no registered objectors present. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented the item with a recommendation of approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff also presented a recommendation that the 29,000 square foot office/retail building be limited to O-3 uses and allowed ten percent of the total square footage to be utilized by the listed O-3 accessory uses. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 23 FILE NO.: Z-6376-A NAME: Gilbert Acres Subdivision Revised Short-form PD-R LOCATION: On Gamble Road, South of Stacey Lane DEVELOPER: Rymor LLC P.O. Box 241667 Little Rock, AR 72223 ENGINEER: McGetrick and McGetrick Engineers 319 President Clinton Avenue, Suite 202 Little Rock, AR 72201 AREA: 0.433 Acres NUMBER OF LOTS: 2 FT. NEW STREET: 0 CURRENT ZONING: PD-R ALLOWED USES: Residential Eight Units PROPOSED ZONING: Revised PD-R PROPOSED USE: Residential Eight Units and the creation of a two-lot plat. VARIANCES/WAIVERS REQUESTED: None requested. BACKGROUND: Ordinance No. 17,579, adopted by the Little Rock Board of Directors on October 21, 1997, established Coleman Short-form PD-R. The site was to develop as a planned residential development with two buildings containing eight townhouse units accessed by a single drive from Gamble Road. The site has developed in this manner under a single lot and single ownership. A. PROPOSAL/REQUEST: The applicant proposes the revision to a previously approved Planned Residential Development to allow the creation of a two-lot plat. Currently there are eight townhouse units on the site and the applicant is proposing to split the tract into two lots; each lot containing four units. The site contains mailbox units March 11, 2004 SUBDIVISION ITEM NO.: 23 (Cont.) FILE NO.: Z-6376-A 2 on each individual proposed lot as well as a pad for trash bins. The existing sign is located on proposed Lot 1. The applicant has provided a sign easement and is not requesting any additional signage for Lot 2. The site will share the existing single drive, which will be dedicated as a cross access and utility easement. B. EXISTING CONDITIONS: The site contains an existing residential development containing eight units. There is a single drive within the development with four units on the north and four units on the south. The units are two story townhouse units. Other uses in the area include residential and office uses. There are single-family detached homes located to the south of the site and a multi-family development similar to the applicant’s located to the west. There are office uses located to the north of the site adjacent to the development and across Stacey Lane. There is an auto detail shop located to the east of the site on O-3 zoned property owned by a nearby automobile dealership. There is a large apartment complex located to the west of the site. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. All residents who could be identified located within 300-feet of the site, the Gibralter Heights/Point West/Timber Ridge and the Parkway Place Neighborhood Associations and all owners of property located within 200-feet of the site were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. No additional comments on proposed lot split. Current development meets Public Works requirements. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Entergy: No comment received. Center-Point Energy: Approved as submitted. SBC: No comment received. March 11, 2004 SUBDIVISION ITEM NO.: 23 (Cont.) FILE NO.: Z-6376-A 3 Central Arkansas Water: If existing meters are on a different parcel than the one that is served, the meters would need to be relocated to the parcel served at the expense of the developer. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional details. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: This request is located in the Ellis Mountain Planning District. The Land Use Plan shows Multi-family for this property. The applicant has applied for a revision to an existing Planned Residential Development. The request does not require a change to the Land Use Plan. City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the Rock Creek Neighborhood Action Plan. The Residential Development goal of creating an aesthetically pleasing and well-planned neighborhood listed an objective of maintaining the quality of the neighborhood and also listed an action statement of using Multi-family development as a buffer between residential and non-residential uses. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Pat McGetrick was present representing the request. Staff presented the item indicating there were additional items needed on the proposed site plan. Staff questioned if there would be any additional signage for the second lot. Staff also requested the applicant label the mail kiosk and the trash bin pad on the proposed site plan. Staff stated the name/address and source of title be included on the proposed site plan. Staff noted comments from Central Arkansas Water and the Little Rock Fire Department indicating Mr. McGetrick should contact each of these agencies should he have any questions. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. March 11, 2004 SUBDIVISION ITEM NO.: 23 (Cont.) FILE NO.: Z-6376-A 4 H. ANALYSIS: The applicant submitted a revised site plan to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated a sign easement on the site plan to allow Lot 2 rights to the sign located on proposed Lot 1. The applicant has also labeled the mail kiosk and the trash bin pad as requested by staff. The proposed site plan includes the name/address and source of title of the property owner as requested. Staff is not supportive of the proposed request. The previous approval included the development as a single development under a single ownership. Staff feels the proposed development should be maintained as a single tract to ensure a single ownership. Historically, the City has not had good luck with small developments with multiple owners. The trend has been that developments that are allowed multiple owners have not been maintained in similar manners, which has caused blight to the area. If the lot is split there is no guarantee the development will not end up with multiple owners. Staff feels to avoid any potential future issues, the request should be denied and the tract remain as a single development. I. STAFF RECOMMENDATION: Staff recommends denial of the request. PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Pat McGetrick was present representing the request. There were no registered objectors present. Staff presented the item with a recommendation of denial. Mr. McGetrick addressed the Commission on behalf of the applicant. He stated the site was fully developed as indicated by staff. He stated the desire was to create two lots allowing a building on each lot. He stated the owner did not intend to sell any of the lots but there was no guarantee that he would maintain ownership. He stated the subdivision of the site should not have any adverse impact on the adjoining properties. There was no further discussion of the item. A motion was made to approve the request as filed. The motion failed by a vote of 0 ayes, 9 noes and 2 absent. March 11, 2004 ITEM NO.: 24 FILE NO.: Z-6554-B NAME: Bowman Kanis Retail Center Revised Long-form PCD LOCATION: On the Northwest corner of Kanis Road and Bowman Road DEVELOPER: Dickson Flake Partners 1200 West Capitol Little Rock, AR 72202 ENGINEER: White-Daters and Associates #24 Rahling Circle Little Rock, AR 72223 AREA: 8.1 Acres NUMBER OF LOTS: 7 FT. NEW STREET: 0 CURRENT ZONING: O-3, PCD and C-3, with conditions ALLOWED USES: O-3 and C-2 permitted uses with a 300-foot by 150-foot no build area at the intersection PROPOSED ZONING: C-3, O-3 and Revised PCD PROPOSED USE: Creation of an eight (8)-lot plat with Lot 1 to develop as a PCD for USA Drug, Lot 7 to develop with O-3 listed uses and Lots 2 – 6 and 8 to develop with C-3 listed uses. VARIANCES/WAIVERS REQUESTED: 1. A variance to allow reduced driveway spacing for Lot 1. 2. A variance to allow the creation of a lot without public street frontage. 3. A variance to allow site grading without a proposed development. 4. A variance to allow a vertical cut greater than ordinance standard. BACKGROUND: On October 20, 1998, the Little Rock Board of Directors adopted Ordinance No. 17,850 rezoning an 11.25-acre tract to O-3 and C-3 on the northwest corner of Kanis and Bowman Roads. The proposal included the development of the site with a 300 foot by 150 foot no build area at the intersection of Kanis and Bowman Roads. The site had limited driveways onto Kanis Road. The eastern drive, located approximately 200-feet March 11, 2004 SUBDIVISION ITEM NO.: 24 (Cont.) FILE NO.: Z-6554-B 2 west of the Kanis/Bowman Road intersection, was proposed as a right-turn exit only. The western driveway, located approximately 300 feet west of the Kanis/Bowman intersection, was to be a service entrance/exit only. The approval also limited the permitted uses to those listed in the “C-2” Shopping Center District. A proposal which included this tract of land was reviewed and approved by the Commission earlier this year but was not forwarded to the Board of Directors for final action. The applicant proposed to rezone the site from various zoning classifications to PCD to allow the development of a home center on the site. Ordinance No. 18,985 adopted November 18, 2003, established the Bowman and Kanis Retail Center Long-form PCD. The Planning Commission heard the proposal at their October 16, 2003 Public Hearing and forwarded a recommendation of approval to the Board of Directors. The applicant proposed a seven-lot plat through the Planned Development process. Lots 1 - 6 were zoned C-3, General Commercial and Lot 7 was zoned O-3, General Office. The applicant proposed a USA Drug to locate on Lot 1 (an allowable use under the C-3 zoning classification) but the building was proposed to be located within the area previously approved as a no-build zone (300-foot by 150-foot). The applicant indicated only one lot would be developed under the proposed development plan and requested Lot 1 be designated with PCD zoning (with C-3 uses as alternative uses) retaining the C-3 and O-3 zoning on the other six lots. A. PROPOSAL/REQUEST: The applicant proposes to revise the previously approved PCD to allow the addition of gas pumps to the original USA Drug PCD. The applicant also intends to add an additional 1.8 acres to the previously approved preliminary plat with land area located to the north of previously proposed Lot 7. The applicant has removed the building from the 300-foot by 150-foot no build zoned and has indicated the gas pumps outside this area as well. The proposed lot (Lot 8)will be served by a shared access and utility easement located on the east and south property lines. B. EXISTING CONDITIONS: The site contains an existing non-conforming nursery. The property is located in an area of mixed zoning and extremely varied uses. The intensely commercial Chenal Parkway/Bowman Road intersection is directly north of the site. Uses in this area include a wide variety of retail commercial businesses such as Sam’s, Wal-Mart, Garden Ridge and Best Buy. Across Bowman, at the northeast corner March 11, 2004 SUBDIVISION ITEM NO.: 24 (Cont.) FILE NO.: Z-6554-B 3 of Kanis and Bowman Road is a PCD, which has developed as an office/warehouse/retail center. The C-3 and PCD zoned properties to the south; contain a variety of uses including offices, office/warehouse and mini- warehouses. The area to the west of the site contains single-family homes on large tracts. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. The Gibralter Heights/Point West/Timber Ridge Neighborhood Association, the Parkway Place Property Owners Association, all owners of property located within 200-feet of the site and all residents located within 300-feet of the site were notified of the Public Hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. The standard conditions shown on the plans as "Public Works Notes" apply to the project. 2. On Bowman, street improvements should match the improvements made to the east. In addition to the lanes shown, dual left turns should be provided for in the design. 3. Per the previous approval, the northern-most driveway should be moved south away from the property line. 4. Street Improvement plans shall include signage, striping and modifications to the signal. Traffic Engineering must approve completed plans prior to construction. 5. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Site grading, and drainage plans will need to be submitted and approved prior to the start of construction. Terracing, cut and fill slopes must comply with the land alteration ordinance. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Entergy: No comment received. Center-Point Energy: Approved as submitted. SBC: No comment received. March 11, 2004 SUBDIVISION ITEM NO.: 24 (Cont.) FILE NO.: Z-6554-B 4 Central Arkansas Water: The facilities on-site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. A Capital Investment Charge based on the size of connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Please submit two copies of the plans for the private fire line to Central Arkansas Water for review. Contact Central Arkansas Water regarding procedures for installation of private fire line. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. Central Arkansas Water requests that a 15-foot-wide utility easement be dedicated adjoining the west lot line of Lot 7 to accommodate an existing 2- inch water main. A water main extension would be required to serve Lot 6. All Central Arkansas Water requirements in effect at the time of request for water service must be met. This development will have minor impact on existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Additional fire hydrants may be required. Contact the Little Rock Fire Department at 918-3752 for additional details. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: This request is located in the Ellis Mountain Planning District. The Land Use Plan shows Mixed Office Commercial for this property. The applicant has applied for a revision to an existing Planned Commercial Development to add gas pumps. The request does not require a change to the Land Use Plan. City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the Rock Creek Neighborhood Action Plan. The Office and Commercial Development goal seeks to maintain the residential integrity of the neighborhood with the objective of adhering to the Future Land Use plan and lists an action statement of requiring developments in the neighborhood to adhere to the Future Land Use plan. March 11, 2004 SUBDIVISION ITEM NO.: 24 (Cont.) FILE NO.: Z-6554-B 5 Landscape: Areas set aside for landscaping and buffers appear to meet city requirements. An automatic irrigation system to water landscaped areas will be required. Prior to a building permit being issued, it will be necessary to provide an approved landscape plan stamped with the seal of a Registered Landscape Architect. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Joe White was present representing the request. Staff presented the request to the Committee members indicating the requested revision was to allow the addition of gas pumps to the original Lot 1 of the development and to add additional acreage with an additional lot to the previously approved preliminary plat. Staff requested Mr. White provide additional information to complete the review process. Staff stated details concerning proposed signage should be provided (height/area) on the proposed site plan. Staff also requested the total area of each lot be provided on the proposed site plan. Public Works comments were addressed. Staff stated Bowman Road should be constructed to match the improvements located to the east of the site. Staff also requested the applicant provide dual left turn lanes at the intersection. Staff also stated a grading permit would be required prior to development of the site. Mr. White stated he was requesting a variance to allow the entire site to be graded without specific developments for Lots 2 – 8. Mr. White stated the cut would be approximately a fifty foot cut. He stated a three to one slope could be achieved without benching. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plan to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated signage details on the proposed site plan. The applicant has indicated signage will be consistent with signage allowed in commercial zones or a maximum of thirty-six feet in height and one hundred sixty square feet in area. Staff is not supportive of the proposed signage. Staff would recommend the signage be limited to a maximum of ten feet in height and one hundred square March 11, 2004 SUBDIVISION ITEM NO.: 24 (Cont.) FILE NO.: Z-6554-B 6 feet in area. Staff feels with the development of eight lots on this corner and each individual lot having a separate free standing sign the maximum signage allowed in commercial zones would cause visual clutter to the area. The proposed development includes the development of a lot without public street frontage. The lot is also requesting an off premise sign easement. Staff is supportive of this proposed lot configuration and sign location. The applicant has indicated the total lot area on each of the proposed lots. The lots range in size from 0.56 acres to 4.05 acres. The proposed lots are currently zoned PCD, O-3 and C-3. The applicant has indicated sufficient area to meet the minimum lot size requirement per the zoning ordinance. The applicant has also indicated a twenty-five foot platted building line adjacent to the roadways. The proposed front yard building line is adequate to meet the minimum requirements of the zoning ordinance. The applicant has indicated the days and hours of operation to be from 5:00 am to 1:00 am seven days per week. The applicant has also indicated the garbage collection will be scheduled from 7:00 am to 6:00 pm to limit the impact on the single-family homes located to the south and west of the site. The applicant has indicated a maximum building height of 35-feet consistent with maximum building heights allowed by the O-3 and C-3 zoning district. The applicant has also indicated site lighting will be low level and directional, directed inward away from residentially zoned properties. The proposed site plan for the USA Drug Store (Lot 1) indicates a total building square footage of 10,500 square feet and a total of 105 parking spaces. The typical minimum parking required for a building of this sized based on one space per three hundred square feet of gross floor area would be 35 parking spaces. As indicated in the background section, a 150-foot by 300-foot area was previously designated as a no build area. The applicant has indicated 51 parking spaces within the previously set no-build zone. This area was also limited to uses listed in the C-2 Shopping Center District zoning classification. The applicant is proposing the placement of a drug store with gas pumps. Although this is an allowable use under the C-3 zoning district a convenience store with gas pumps (the most direct comparison) is not an allowable use under the C-2 zoning district. The previously approved PCD requested C-3 uses as alternative uses for the site. The applicant is requesting a fifty-foot cut along the western edge of the property, which is a variance from the Land Alteration Ordinance. The applicant is also requesting to be allowed to grade Lots 2 – 8 without a specific development. Staff is not supportive of this request. The Land Alteration Ordinance specifically prohibits indiscriminate clearing of property. The ordinance also states cuts or March 11, 2004 SUBDIVISION ITEM NO.: 24 (Cont.) FILE NO.: Z-6554-B 7 fills shall be limited to ten feet in height or fifteen feet if architectural stone is included to protect the vertical face. Staff is not supportive of this request. Staff is not supportive of the proposed request. Staff feels the placement of gas pumps at this location is not in keeping with the desired development pattern previously approved. The historical development pattern has been to keep the hard commercial uses east of Bowman Road and allow commercial uses to step down west of Bowman Road. Staff feels if this intense development is allowed to locate west of Bowman Road the domino effect will take place resulting in Kanis Road being lined with commercial uses. I. STAFF RECOMMENDATION: Staff recommends denial of the request as filed. PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Joe White was present representing the request. There were no registered objectors present. Staff stated they were requesting the item be deferred to the March 25, 2004 Public Hearing to allow additional time to review additional information submitted by the applicant related to the requested cut and fill of the site. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 25 FILE NO.: Z-7225-A NAME: Grace Presbyterian Church Long-form POD LOCATION: 9301 Rodney Parham Road DEVELOPER: Grace Presbyterian Church 9301 Rodney Parham Road Little Rock, AR 72205 ENGINEER: The Holloway Firm, Inc. 200 Cassey Drive Maumelle, AR 72113 AREA: 4.5 Acres NUMBER OF LOTS: 2 FT. NEW STREET: 0 CURRENT ZONING: R-2, Single-family ALLOWED USES: Single-family and non-conforming church use PROPOSED ZONING: POD PROPOSED USE: Church and office use VARIANCES/WAIVERS REQUESTED: A variance to allow an existing sign to be located off premise identifying the use of proposed Lot 1 and located on proposed Lot 2. BACKGROUND: The Little Rock Board of Adjustment reviewed a sign variance to permit a ground- mounted sign, which exceeded the maximum height allowed under Section 36-553 of the Little Rock Code of Ordinances. The applicant proposed the placement of a single ground mounted ten-foot sign with a total area of forty-eight square feet west of the eastern access drive. The application was amended to include the placement of a second sign on the site. The applicant’s request to maintain the existing sign location and place the second sign on the site was approved. March 11, 2004 SUBDIVISION ITEM NO.: 25 (Cont.) FILE NO.: Z-7225-A 2 A. PROPOSAL/REQUEST: The site located at 9301 North Rodney Parham Road is currently a single tract of land and occupied by Grace Presbyterian Church. The applicant is proposing to develop the site as a POD to allow the creation of a two-lot plat and the construction of an office building to be leased to the State Presbytery. The applicant has indicated the new building will be 5,025 square feet and single story. There are no new drives proposed as a part of the development. The existing drive will be platted as an access and utility easement to allow access from the existing church lot to North Rodney Parham Road. The applicant has indicated a sign easement on proposed Lot 2 for an existing sign located on the site identifying the church. Signage will also be placed on proposed Lot 2 identifying the new office use. B. EXISTING CONDITIONS: The site is located south of Rodney Parham Road at the intersection with Reservoir Road. The driveway aligns with the traffic signal at Rodney Parham Road and Reservoir Road. Other uses in the area include a mixture of uses. To the north there is a strip retail center. To the east are office uses with residential uses on the top floor. To the south are duplex units along Rosenlinn Drive and single-family homes located along Burnside and Kordsmeier Court. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has received several phone calls requesting additional information from area residents. All residents who could be identified located within 300-feet of the site, the Treasure Hills and Santa Fe Neighborhood Associations and all owners of property located within 200-feet of the site were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Rodney Parham is classified on the Master Street Plan as a minor arterial. A minimum dedication of right-of-way 45 feet from centerline will be required at all points along the frontage. 2. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. March 11, 2004 SUBDIVISION ITEM NO.: 25 (Cont.) FILE NO.: Z-7225-A 3 E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Entergy: A 10-foot underground or a 15-foot overhead easement is required. Contact Entergy at 954-5158 for additional information. Center-Point Energy: Approved as submitted. SBC: No comment received. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all meter connections including any metered connections off the private fire system. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional details. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: This request is located in the Rodney Parham Planning District. The Land Use Plan shows Public Institutional for this property. The applicant has applied for a Planned Office Development for a religious use office building. The request does not require a change to the Land Use Plan. City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the West Markham Neighborhood Action Plan. The Land Use goal lists an action statement of limiting non-residential development to areas shown for non-residential uses on the Future Land Use Plan. March 11, 2004 SUBDIVISION ITEM NO.: 25 (Cont.) FILE NO.: Z-7225-A 4 Landscape: A six (6) foot high opaque screen, either a wall, or wooden fence with its face side directed outward, or dense evergreen plantings, is required along the southern perimeter of the site. An automatic irrigation system to water landscaped areas will be required. Prior to a building permit being issued, it will be necessary to provide an approved landscape plan stamped with the seal of a Registered Landscape Architect. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) The applicant was present representing the request. Staff presented an overview of the proposed development indicating additional items were needed to complete the review process. Staff requested additional information related to the proposed preliminary plat. Staff requested the applicant provide the means of wastewater disposal, the source of water and details of any proposed fencing. Staff also requested the applicant indicated any proposed dumpster on the site. Public Works comments were discussed. Staff stated Rodney Parham Road was classified on the Master Street Plan as a minor arterial and dedication of right-of-way 45-feet from the centerline would be required. Staff also stated any damaged sidewalks or curb and gutter must be repaired prior to occupancy. Landscaping comments were addressed. Staff stated a six (6) foot high screen would be required along the southern perimeter of the site adjacent to residentially zoned properties. Staff also stated irrigation would be required to water landscaped areas. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised preliminary plat and revised preliminary site plan to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated the source of water as Central Arkansas Water and the means of wastewater disposal as Little Rock Wastewater Utility. The applicant has indicated no new fencing will be added as a result of the project. The applicant has indicated screening will be added along the southern property line as required by the zoning ordinance to screen adjoining single-family zoned properties. The applicant has indicated no new dumpsters will be added to the site as a result of the new construction of the 5,025 square foot office building. March 11, 2004 SUBDIVISION ITEM NO.: 25 (Cont.) FILE NO.: Z-7225-A 5 The proposed development includes the construction of a new office building to serve as the State Offices of the Presbyterian Church. The proposed new office building will be constructed in the same architectural style and building materials as the existing church. The applicant has indicated construction of twenty-nine new parking spaces as well. Typical minimum parking requirements for an office building of this size would be twelve parking spaces. The proposed new parking is more than adequate to serve the new building. There is existing parking located on the site for the church facility and the site will provide a cross access parking agreement between the two lots. This should minimize any concerns of parking on the site and any potential future problems, which may arise concerning parking between the two lots. The applicant has indicated an existing sign will be located on proposed Lot 2. The applicant has indicated a sign easement to allow the sign to remain and is requesting a variance to allow an off premise sign. Staff is supportive of this request. Staff feels the existing sign is located in an area that will cause minimal to no adverse impact on the proposed lot. The applicant has not indicated proposed signage details concerning signage for the proposed office building located on proposed Lot 2. Staff recommends this signage be limited to signage allowed in office zones or a maximum of six feet in height and sixty-four square feet in area. The applicant has indicated there is not a Bill of Assurance in effect for the proposed site. The area has not been final platted and is held in a metes and bounds legal description. Otherwise, to staff’s knowledge there are no outstanding issues associated with the proposed request. The applicant has indicated the new construction adjacent to Rodney Parham Road away from the residential properties located to the south. The applicant has indicated construction of a single-story building, which should minimize the impact on the adjoining homes. The applicant has indicated building setbacks more than adequate to meet typical setbacks for office zoned properties and buffers adequate to meet the minimum required buffers for office properties adjacent to single-family properties. Staff feels the proposed development should have minimal to no adverse impact on adjoining properties. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff recommends signage be limited to signage allowed in office zones or a maximum of six feet in height and sixty-four square feet in area. Staff recommends approval of the requested variance to allow an off premise sign on proposed Lot 2 to serve proposed Lot 1. March 11, 2004 SUBDIVISION ITEM NO.: 25 (Cont.) FILE NO.: Z-7225-A 6 PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were no registered objectors present. Staff presented the item indicating to their knowledge there are no outstanding issues associated with the proposed request. Staff presented a recommendation of approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff presented a recommendation that signage be limited to signage allowed in office zones or a maximum of six feet in height and sixty-four square feet in area and a recommendation of approval of the requested variance to allow an off premise sign on proposed Lot 2 to serve proposed Lot 1. Staff also presented a recommendation of approval of the requested variance to allow an off premise sign for the proposed development. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 26 FILE NO.: Z-7327-B NAME: Shear Magic Revised Short-form PD-C LOCATION: 1911 West 2nd Street DEVELOPER: Mr. Robert Hardin Hardin and Grace, P.A. 410 West Third Street, Suite 200 Little Rock, AR 72201 ENGINEER: Ollen Dee Wilson P.O. Box 604 North Little Rock, AR 72215-0604 AREA: 0.25 Acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 CURRENT ZONING: PCD – Planned Commercial Development ALLOWED USES: Residential and Single Chair Beauty Shop PROPOSED ZONING: Revised PCD PROPOSED USE: Residential, Single Chair Beauty Shop and Massage Therapist VARIANCES/WAIVERS REQUESTED: None requested. BACKGROUND: The applicant’s proposal to rezone the site to Planned Commercial Development (PCD) to convert an existing duplex to a mix of commercial and residential uses was approved by the Board of Directors at their January 21, 2003, Public Hearing by the adoption of Ordinance No. 18,805. The applicant proposed one unit to be used as a residence and the second unit to be used Tuesday through Saturday as a one chair, single operator, beauty salon (approximately 900 square feet). The applicant proposed the days and hours of operation to be Tuesday through Saturday from 7:00 am to 8:00 pm. March 11, 2004 SUBDIVISION ITEM NO.: 26 (Cont.) FILE NO.: Z-7327-B 2 The applicant proposed the placement of two (2) parking spaces on the site located in the rear of the structure adjacent to the alley. The applicant did not propose any signage as a part of the development except signage on the building façade indicating the entrance on the unit, which would house the beauty salon. A. PROPOSAL/REQUEST: The applicant now proposes to revise the previously approved PCD to allow a massage therapist to locate within the existing beauty shop. The applicant has indicated the massage therapist will use one of the existing rooms within the beauty shop portion of the structure and operate during the same hours as the beauty shop. The second unit of the duplex will remain residential. The applicant has also indicated a revision to the previously approved parking plan. The applicant has indicated a twenty foot by twenty foot concrete parking pad located off the street near the back of the property. The applicant has indicated the addition of four parking spaces on the existing gravel parking area lying immediately behind and to the east of the parking pad and to add a concrete circular driveway at the front of the property exiting onto West Second Street, which will add two additional parking spaces for customers. The applicant has indicated West Second Street is a dead end street just east of the site. The property immediately east of the site is unoccupied. B. EXISTING CONDITIONS: The site is an existing residential unit with a single-chair beauty shop located on the lower level. There is parking in the rear yard of the structure and a gravel circular drive located in the front of the structure. There are both non-residential and residential uses located in the area with a multi-tenant multi-family structure located to the west of the site, a converted single-family structure to a multiple tenant structure located to the north of the site, a boarded and abandoned single- family structure located to the east of the site and a photography studio located south of the site. Gary Huston Electric is located to the south and east of the site with his lot and fencing extending to West 2nd Street and commercial vehicles are being parked in this area. There are single-family homes located in the area, west of Summit Street and north of West 2nd Street. The streets in the area (Battery Street and West 2nd Street) are narrow unimproved roadways with Battery Street being no wider than an alley at the rear of the site. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has received one informational phone call from an area resident. All property owners within 200 feet of the site, all residents within March 11, 2004 SUBDIVISION ITEM NO.: 26 (Cont.) FILE NO.: Z-7327-B 3 300 feet of the site, who could be identified and the Capitol View/Stifft Station Neighborhood Association were notified of the Public Hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Per previous comments, future construction will require improvements to Battery and West Second Street per Master Street Plan. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Entergy: Approved as submitted. Center-Point Energy: Approved as submitted. SBC: No comment received. Central Arkansas Water: Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZA) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact Carroll Keatts at 992- 2431 if you would like to discuss backflow prevention requirements for this project. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Approved as submitted. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: This request is located in the Heights Hillcrest Planning District. The Land Use Plan shows Office for this property. The applicant has applied for a revision to an existing Planned Commercial Development to allow a message therapist. March 11, 2004 SUBDIVISION ITEM NO.: 26 (Cont.) FILE NO.: Z-7327-B 4 The request does not require a change to the Land Use Plan. The use applied for is an accessory use to the existing beauty shop. The beauty shop is a use that is permitted in Office as a Planned Zoning District, and will not change the footprint of the existing structure. City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the Capital View / Stifft Station Neighborhood Action Plan. The Community Preservation goal listed an objective of preserving the housing stock in the neighborhood that is supported by an action statement calling for the no net loss of housing units due to changes in land use. The revision of an existing PCD does not reduce the housing stock of the neighborhood. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) The applicant was not present. Staff briefly described the proposed request indicating there were no outstanding issues associated with the proposed request. Staff noted the request was to include changes to the site plan for additional parking and to add a massage therapist use to the approved planned development. Staff noted the massage therapist would utilize space in the existing beauty shop and the top floor of the unit would remain residential. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant is requesting to add an additional use to the approved uses for the site while maintaining the residential portion of the proposed development. The applicant has requested to add a massage therapist as an allowable use to the Planned Commercial Development, which will utilize space in the existing beauty shop area. The top floor of the structure will remain as a residential unit. The applicant has also indicated the addition of a circular driveway located in the front of the structure to be constructed of a hard surface if approved. The applicant has also indicated the addition of four parking spaces, in the rear of the structure, which will remain gravel. Staff is supportive of the proposed parking. The applicant has constructed a twenty by twenty foot parking pad in the rear which will eliminate tracking of the proposed gravel onto the City street. Staff also supports the circular drive located in the front of the structure. West Second Street dead-ends to the east of this site minimizing concerns of through traffic conflicts. March 11, 2004 SUBDIVISION ITEM NO.: 26 (Cont.) FILE NO.: Z-7327-B 5 To Staff’s knowledge there are no outstanding issues associated with the proposed request. The applicant is requesting the revision to add a massage therapist as an allowable use to the site, which will operate during the current hours of operation of the beauty salon. The applicant has indicated the second unit will remain as a residential unit and the overall character of the structure will not change. The applicant is not requesting any additional signage as a part of the proposed development. Staff feels the addition of a massage therapist, as an allowable use to the list of uses for the site should have minimal to no adverse impact on the adjoining properties. The applicant has indicated there is not a Bill of Assurance in effect for the subdivision, which would conflict with the proposed request. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were no registered objectors present. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented a recommendation of approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff presented a recommendation of approval of the requested variance to allow an off premise sign for the proposed development. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 27 FILE NO.: LU04-01-02 Name: Land Use Plan Amendment - River Mountain Planning District Location: North side of Highway 10, East of Taylor Loop Road Request: Transition to Commercial Source: John Rees PROPOSAL / REQUEST: Land Use Plan amendment in the River Mountain Planning District from Transition to Commercial. The Commercial category includes a broad range of retail and wholesale sales of products, personal and professional services, and general business activities. Commercial activities vary in type and scale, depending on the trade area that they serve. The applicant wishes to develop the property for strip retail with offices and warehouses in the back. Prompted by this Land Use Amendment request, the Planning Staff expanded the area of review to include the area to the south fronting Cantrell Road. This expansion would recognize the existing uses fronting Cantrell Road. EXISTING LAND USE AND ZONING: The applicant’s property is vacant land currently zoned R-2 Single Family and is 8.93 acres ± in size. The expanded area also includes a restaurant, antique store, and a house located on the north side of Cantrell Road west of Pinnacle Valley Road. The property to the north and east consists of large-lot single-family houses along Pinnacle Valley Road and houses built on traditional sized lots on Pine Mountain Road. The property along the south side of Cantrell Road consists of vacant land along Ison Creek, houses along Westbury Drive, a bank zoned Planned Commercial Development at Jerry Drive, a church zoned R-2 with a C.U.P., a second bank closer to Taylor Loop Road zoned PCD, and a house zoned R-2 on the southeast corner of the Taylor Loop / Cantrell Road intersection. A shopping center zoned C-3 General Commercial is located southwest of the amendment area at the northeast corner of the Taylor Loop / Cantrell Road intersection. The land to the west is vacant property zoned R-2. FUTURE LAND USE PLAN AND RECENT AMENDMENTS: On August 19, 2003 a change was made from Transition to Commercial at 14410 Cantrell Road less than 1/10 of a mile to the east of the applicant’s property to accommodate proposed development. On February 18, 2003 multiple changes were made from Transition and Low March 11, 2004 SUBDIVISION ITEM NO.: 27 (Cont.) FILE NO.: LU04-01-02 2 Density Residential to Suburban Office, Single Family, Commercial, Park / Open Space, Low Density Residential, Office, and Public Institutional along Cantrell Road within a 1 mile radius of the amendment area to recognize existing conditions. On April 20, 1999 a change was made from Single Family and Low Density Residential, to Commercial, Office, Multifamily, and Park / Open Space on Cantrell at Black Road about a ½ mile east of the property in question to recognize existing conditions. The expanded amendment area is shown as Transition on the Future Land Use Plan. Ison Creek running along the east side of the applicant’s property is shown as Park / Open Space along the creek floodway. The property to the north is shown as Single Family while the property to the east is shown as Transition. The land on the south side of Cantrell Road from Ison Creek to Taylor Loop Road is shown as Park / Open Space, Single Family, Suburban Office, Public Institutional and Commercial. The property at the north side of the Taylor Loop / Cantrell Road intersection is shown as Commercial. The land to the west is shown as Single Family. An area shown as Transition near the northwest corner of the Taylor Loop / Cantrell Road intersection is the subject of another item on this agenda for a change to Commercial. MASTER STREET PLAN: Cantrell Road is shown on the Master Street Plan as a Principal Arterial and is built as a four-lane highway with an additional center turn lane. Pinnacle Valley Road is shown as a Minor Arterial and is built as a rural two-lane road and would be subject to half-street improvements in order to bring the road into conformance with Master Street Plan Standards. A Class III bikeway is shown on Pinnacle Valley Road from State Highway 300 to Cantrell Road. Although, a Class III bikeway does not require any additional right-of-way or paving, but would require bike lanes to marked on the street and would also require additional signage. PARKS: The Little Rock Parks and Recreation Master Plan of 2001 shows the Taylor Loop Park located a short distance to the southwest of the applicant’s property. Taylor Loop Park is about 35.0+ acres. Taylor Loop Park is listed as an undeveloped Community Park intended to remain as a passive open space parcel of undeveloped land and is designed to serve the open space needs of several neighborhoods. March 11, 2004 SUBDIVISION ITEM NO.: 27 (Cont.) FILE NO.: LU04-01-02 3 The plan also shows a Potential Greenbelt along the floodway of Ison Creek running parallel to Pinnacle Valley Road along the east side of the expanded amendment area. Development of the study area will need to respect the integrity of the drainage system located in the 100-year flood plain of the creek as well as the integrity of the Potential Greenbelt shown in the plan. HISTORIC DISTRICTS: There are no city recognized historic districts that would be affected by this amendment. City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the River Mountain Neighborhood Action Plan. The Sustainable Natural Environment goal listed an objective of promoting the vigorous enforcement of the Landscaping & Excavation Ordinance. This action could result in the removal of trees in order to accommodate the development of uses possible in the Commercial land use category. ANALYSIS: The application area is located in close proximity to two intersections between Minor Arterials with a Principal Arterial. In addition, areas shown as Commercial have expanded recently and further reduced the area shown as Transition as well as reducing the potential for future residential development on the north side of Cantrell Road. The proposed change from Transition to Commercial located to the southwest of the area covered by this application will also have the same effect. Since a large amount of the property shown as Commercial in the vicinity of the applicant’s property is developed with existing Commercial uses the properties not developed for businesses will face increased pressure to develop for non-residential uses. All of these changes will result in a large strip of non- residential development on the north side of Cantrell Road from an area east of Pinnacle Valley Road to an area west of Taylor Loop Road. The first 300 feet of the applicant’s property and the expanded study area are located in the Highway 10 Design Overlay District. Any development of the property within 300 feet of Cantrell Road would need to conform to the design standards of the Highway 10 DOD. In areas shown as Transition, a Planned Zoning District is required unless an application conforms to the Design Overlay standards. The design standards of the Highway 10 DOD are intended to protect the scenic value of the Highway 10 DOD through the requirement of PZD’s. March 11, 2004 SUBDIVISION ITEM NO.: 27 (Cont.) FILE NO.: LU04-01-02 4 The amendment proposed for the study area would place Commercial uses next to developing and existing Single Family uses to the north. Since Commercial is a more intense use than Single Family, any non-residential development in the study area should be done in a manner which will protect and buffer the residential areas from any Commercial uses. In addition, although the vacant land to the west is not yet developed, the integrity of future Single Family should also be protected. The applicant’s property was the subject of a Land Use Plan Amendment for a change from Transition to Suburban Office. It was a part of a Future Land Use review along Cantrell Road presented to the Planning Commission on January 9, 2003. The change to Suburban Office affecting the applicant’s property was denied at that meeting based on Staff recommendation. It was determined that the Transition land use category allowed for office development similar to the requirements found in the Suburban Office category but also allowed residential development. Although the Transition category allows for both office and residential development, the pattern of development in areas shown as Transition along Cantrell Road has favored the creation of new office spaces. However, the areas shown as Transition do not eliminate the possibility of future residential development along Cantrell Road. This amendment would not only expand the amount of land shown as Commercial, but it would reduce the amount of land available for office development along the Cantrell Road corridor and eliminate the possibility of future residential development in the area shown as Transition covered by this amendment. A change to Commercial would reduce the buffer between the intense uses fronting Cantrell Road and the less intense uses located to the north. NEIGHBORHOOD COMMENTS: Notices were sent to the following neighborhood associations: Pleasant Valley Property Owners Association, River Valley Property Owners Association, Pankey Community Improvement Association, Piedmont Neighborhood Association, Pleasant Forest Neighborhood Association, Secluded Hills Property Owners Association, Walton Heights-Candlewood Neighborhood Association, Westbury Neighborhood Association, Westchester/Heatherbrae Property Owners Association, Charleston Heights/North Rahling Rd N.A., and Chenal Ridge Property Owners Association. Staff has received one comment from area residents that was neutral. March 11, 2004 SUBDIVISION ITEM NO.: 27 (Cont.) FILE NO.: LU04-01-02 5 STAFF RECOMMENDATIONS: Staff believes the change is not appropriate. This application would result in a strip of commercial development along the north side of Cantrell Road from Pinnacle Valley Road to an area west of Taylor Loop Road. PLANNING COMMISSION ACTION: (March 11, 2004) The item was placed on the consent agenda for deferral to the April 22, 2004 Planning Commission meeting. A motion was made to approve the consent agenda and was approved with a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 27.1 FILE NO.: Z-7500-A NAME: Rees Development Long-form PCD LOCATION: North of Cantrell Road, West of Pinnacle Valley Road DEVELOPER: Rees Development Company 12115 Hinson Road Little Rock, AR 72212 ENGINEER: McGetrick and McGetrick Engineers 319 President Clinton Avenue, Suite 202 Little Rock, AR 72201 AREA: 8.93 Acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 CURRENT ZONING: R-2, Single-family ALLOWED USES: Single-family residential PROPOSED ZONING: PCD PROPOSED USE: Commercial, Office/Warehouse VARIANCES/WAIVERS REQUESTED: None requested. BACKGROUND: A request was withdrawn by the applicant prior to the October 16, 2003, Planning Commission Public Hearing. The applicant proposed the development of a smaller portion of this site with an office/warehouse building and mini-warehouse units. A. PROPOSAL/REQUEST: The owner plans to develop a 23,200 square foot commercial/office building along Cantrell Road and 52,916 square feet of office/warehouse space in two buildings in the rear. The applicant is proposing the placement of eighty-eight parking spaces to serve the commercial/office building and one hundred eighty-nine parking spaces in the rear to serve the office/warehouse buildings. March 11, 2004 SUBDIVISION ITEM NO.: 27.1 (Cont.) FILE NO.: Z-7500-A 2 The applicant has indicated a maximum building height of twenty-five feet and the hours of operation from 7 am to 7 pm seven days per week. The applicant has indicated a single ground mounted monument style sign located in the front yard area of the proposed development consistent with signage allowed in the Highway 10 Design Overlay District. The applicant has indicated a drive-through lane on the eastern end of the commercial/office building. B. EXISTING CONDITIONS: The site is vacant and cleared with a large creek running along the northern and eastern portions of the site. There is a strip retail center located to the west of the site and a restaurant located to the east of the site. North of the creek are single-family homes accessed by Pinnacle Valley Road. There are office uses and small scale commercial uses located to the south of the site (across Cantrell Road) and a small church. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has received one informational phone call from an area resident concerning the proposed development. All residents who could be identified located within 300-feet of the site, the Westchester/Heatherbrae, Secluded Hills and Charleston Heights/North Rahling Road Neighborhood Associations and all owners of property located within 200-feet of the site were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Cantrell Road is classified on the Master Street Plan as a principal arterial. Dedication of right-of-way to 55 feet from centerline will be required. Provide a plan showing the existing and proposed right-of-way lines. 2. The proposed driveway should align with Jerry Drive. Show the location of Jerry Drive on the proposed site plan. 3. Provide design of street conforming to the Master Street Plan. Construct one-half street improvement to the street including a 5-foot sidewalk with the planned development. 4. Provide existing topographic information at maximum five-foot contour interval. Show the limits of the 100-year floodway and floodplain and floodplain elevations along the channel. March 11, 2004 SUBDIVISION ITEM NO.: 27.1 (Cont.) FILE NO.: Z-7500-A 3 5. A Sketch Grading and Drainage Plan will be required per Section 29-186 (e). Show the fill contours, finished floor elevations, slope treatment for stream banks, floodwalls, and any other proposed grading improvements. 6. In accordance with Section 31-176, floodway areas must be shown as floodway easements or be dedicated to the public. In addition, a 25-foot wide access easement is required adjacent to the floodway boundary. 7. A special Grading Permit for Flood Hazard Areas will be required per Section 8-283 prior to construction. Do not commence land clearing or grading without first obtaining a permit. 8. Storm water detention ordinance applies to this property. The project would qualify for a contribution in-lieu of construction at the time of the building permit. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Entergy: A 15-foot Entergy easement is required. Contact Entergy at 954-5158 for additional information. Center-Point Energy: Approved as submitted. SBC: Approved as submitted. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. The facilities on-site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all meter connections including any metered connections off the private fire system. Please submit four copies of the plans for the fire protection system to Central Arkansas Water for review. Contact Central Arkansas Water regarding procedures for installation of fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. Fire sprinkler systems, which do not contain additives such as antifreeze, shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. This development will have minor impact on the existing water March 11, 2004 SUBDIVISION ITEM NO.: 27.1 (Cont.) FILE NO.: Z-7500-A 4 distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Of particular note is the 57-1/2-foot wide easement for the raw water line that crosses this site. There are two large raw water lines in this easement. Two access/air release vaults on the site must be maintained outside the paved area in a manner that will allow them to function properly. No encroachment of buildings, including rooflines, signs, light poles or other structures on foundations will be allowed within this easement. Paved parking and driveways are allowed. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional details. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: This request is located in the Pinnacle Planning District. The Land Use Plan shows Transition for this property. The applicant has applied for a Planned Commercial Development for strip retail with offices and warehouses in the back. A land use plan amendment for a change to Commercial is a separate item on this agenda (Item No. 27 – File No. LU04-20-02). City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the River Mountain Neighborhood Action Plan. The Sustainable Natural Environment goal listed an objective of promoting the vigorous enforcement of the Landscaping & Excavation Ordinance. This action could result in the removal of trees in order to accommodate the development of uses possible in the Commercial land use category. Landscape: The proposed land use buffer along the western perimeter abutting residential property is less than the 25-feet average width required by the Highway 10 Overlay District Ordinance. An additional minimum 300 square foot interior landscaping island will be required within the center of the proposed parking lot nearest Cantrell Road. A 3-foot wide landscape strip is required between the building and public parking areas. Considerable flexibility is allowed with this requirement. March 11, 2004 SUBDIVISION ITEM NO.: 27.1 (Cont.) FILE NO.: Z-7500-A 5 An irrigation system to water landscaped areas is required. Prior to obtaining a building permit, it will be necessary to provide landscape plans stamped with the seal of a registered landscape architect. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Pat McGetrick was present representing the request. Staff presented an overview of the proposed request indicating there were additional items necessary to complete the review process. Staff requested the applicant provide details concerning any proposed signage. Staff also requested the applicant provide a 25-foot floodway easement adjacent to the creek. Staff noted the comment from Central Arkansas Water indication the corner of the building was located within an existing water easement. Public Works comments were addressed. Staff stated Cantrell Road was classified on the Master Street Plan as a principal arterial and dedication of right-of-way would be required. Staff also requested the proposed drive align with Jerry Drive to the south. Staff questioned the amount of fill required for the site. Mr. McGetrick stated the development would require approximately 3-feet of fill. Mr. McGetrick stated a wall would be constructed along the rear to maintain the grade and resolve any issues related to slope. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plan to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated a 25-foot easement adjacent to the floodway. The applicant has also indicated a wall located along the creek to minimize concerns of erosion. The applicant has also indicated alignment of the proposed driveway to align with Jerry Drive located to the south of the proposed development. The applicant has indicated the site area is held in a metes and bounds legal description and there is not a Bill of Assurance which would effect the development of the site. The applicant has indicated a single ground mounted monument style sign consistent with the Highway 10 Design Overlay District standards. The applicant has indicated signage a maximum of ten feet in height and one hundred square feet in area. March 11, 2004 SUBDIVISION ITEM NO.: 27.1 (Cont.) FILE NO.: Z-7500-A 6 The applicant has not removed the corner of the building located within the existing Central Arkansas Water easement. The site plan indicates a fifty-foot easement and an additional seven and one-half foot easement on the site plan. No construction may take place within an existing easement without approval. Staff recommends the building be shortened to remove the corner of the building from the easement. Staff is not supportive of the proposed request. Staff feels the proposed development is too intense for the site. Staff is supportive of the proposed development adjacent to Cantrell Road and some development in the rear but not the placement of two buildings in this area. Staff feels the proposed site would be better served developing in a lesser intensity to the rear eliminating the proposed 12,150 square foot building. This would allow lesser intrusion to the creek area and additional areas set aside for green space. The rear of site is somewhat visible from Pinnacle Valley Road, a well-traveled road accessing three parks. Staff feels the city should make every effort to maintain the beauty of this roadway for visitors to our area. The applicant has indicated eighty-eight parking spaces to serve the commercial/office building. The applicant has not indicated a mix of office and commercial uses in the front building so staff has to assume the building will be developed with one hundred percent commercial uses. Staff is not supportive of allowing the site to develop at this intensity. Staff would recommend the applicant indicate a use mix consistent with the existing Land Use classification. The existing Land Use classification, Transitional, would allow for office development with commercial uses as accessory uses. Staff feels the proposed development should develop with O-3 uses and the allowable ten percent accessory uses. Typical minimum parking requirements for a commercial/office building would be seventy-seven parking spaces based on one space per three hundred square feet of gross floor area (commercial standards). The typical minimum parking requirement for an office/warehouse development would be thirty-two parking spaces. The applicant has indicated one hundred eighty-nine parking spaces substantially more than the typical minimum parking requirement. Staff feels the applicant should greatly reduce the number of parking spaces in this area to eliminate the “sea of asphalt” and enhance scenic beauty of the site. Staff feels the proposed request is too intense for this site and if developed in this manner would have a detrimental impact on the adjoining properties and roadways. I. STAFF RECOMMENDATION: Staff recommends denial of the request as submitted. March 11, 2004 SUBDIVISION ITEM NO.: 27.1 (Cont.) FILE NO.: Z-7500-A 7 PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Pat McGetrick was present representing the request. Staff stated the applicant had submitted a letter dated March 10, 2004 requesting the item be deferred to the April 22, 2004 Public Hearing. Staff stated the applicant was requesting additional time to work with staff to minimize their concerns. Staff stated the requested deferral would require a waiver of the By-laws related to the late deferral request. Staff stated they were supportive of the requested By-law waiver and the deferral request. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 28 FILE NO.: Z-7579 NAME: IUOE Short-form POD LOCATION: 5516 West 11th Street DEVELOPER: International Union of Operating Engineers 5516 West 11th Street Little Rock, AR 72204 ENGINEER: Donald W. Brooks 20820 Arch Street Pike Hensley, AR 72065 AREA: 0.25 Acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 CURRENT ZONING: R-3, Single-family ALLOWED USES: Single-family and non-conforming meeting hall PROPOSED ZONING: PD-O PROPOSED USE: Office/Showroom/Warehouse, Meeting Facility and General and Professional Office Uses VARIANCES/WAIVERS REQUESTED: Deferral of Master Street Plan requirements to West 11th and Taylor Streets until future redevelopment of the site. A. PROPOSAL/REQUEST: The applicant proposes to rezone the site from R-3, Single-family to PD-O (Planned Office Development – Single User) for subsequent users such as a medical equipment sales and supply business, insurance agency, real estate broker or any other office showroom activity that could require some storage as a part of their operation. The applicant has also requested general and professional office uses as potential uses for the site. Currently the site has a circular drive extending from West 11th Street to Taylor Street. The applicant is requesting to allow this drive to continue to function as a March 11, 2004 SUBDIVISION ITEM NO.: 28 (Cont.) FILE NO.: Z-7579 2 one-way drive entering from West 11th Street and exiting to Taylor Street. The applicant is requesting a deferral of the required street improvements until the site is redeveloped with a new building or substantial modification to the existing structure. The applicant has indicated parking on the site plan for six (6) cars constructed of a hard surface material and landscaped per the current Landscape Ordinance. The applicant has indicated signage adjacent to West 11th Street consistent with signage allowed in office zones. The applicant has also indicated cosmetic modifications will be made to the front of the building to enhance the overall appearance of the building. The applicant has requested fencing be allowed in the future should security of the site become an issue. B. EXISTING CONDITIONS: The site contains an existing metal building with a single driveway accessing the site. The drive is a narrow driveway extending from West 11th Street to Taylor Street. Other uses in the area are a mix of residential, office and commercial uses. There is a multi-family complex located to the south of the site, a large church complex located to the west of the site and office uses located to the north of the site. To the east, adjacent to Fair Park, is a large office warehouse building and a carwash is located to the northeast. Both Taylor and West 11th Streets are unimproved roadways with open ditches for drainage. There are not sidewalks in place adjacent to the site. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has received one informational phone call concerning the proposed use of the site. All residents who could be identified located within 300-feet of the site, the Oak Forest and War Memorial Neighborhood Associations and all owners of property located within 200-feet of the site were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. The proposed land use would classify West 11th and Taylor Streets on the Master Street Plan as a commercial street. Dedicate right-of-way to 30 feet from centerline. March 11, 2004 SUBDIVISION ITEM NO.: 28 (Cont.) FILE NO.: Z-7579 3 2. A 20 foot radial dedication of right-of-way is required at the intersection of the streets. 3. Any future construction or re-development of the site will require construction of one-half street improvement to these streets including 5-foot sidewalks in accordance with the Master Street Plan. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Entergy: Approved as submitted. Center-Point Energy: Approved as submitted. SBC: Approved as submitted. Central Arkansas Water: Contact Central Arkansas Water if larger and/or additional water meter(s) are required. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZA) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact Carroll Keatts at 992- 2431 if you would like to discuss backflow prevention requirements for this project. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional details. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: This request is located in the I-630 Planning District. The Land Use Plan shows Mixed Use for this property. The applicant has applied for a Planned Development - Office for an office development. March 11, 2004 SUBDIVISION ITEM NO.: 28 (Cont.) FILE NO.: Z-7579 4 The request does not require a change to the Land Use Plan. City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the Oak Forest Neighborhood Action Plan. The plan does not list any goals, objectives, or actions statements relevant to this case. Landscape: Landscape and buffer requirements will need to be satisfied in association with the development of a parking area. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) The applicant was not present. Staff briefly described the proposed request stating there were few outstanding issues associated with the proposed request. Staff stated they had contacted the applicant indicating a need for a parking plan. Staff stated the applicant had indicated parking for six (6) cars would be added to the proposed site plan and resubmitted as requested. There was no further discussion of the item and the Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised site plan to staff indicating parking sufficient for six (6) cars including one handicap parking space. The applicant has also indicated parking lot landscaping as required by the Landscape Ordinance. Staff is supportive of the proposed parking and landscaping. The applicant has stated there is no new fencing proposed as a part of the development but is requesting fencing be allowed around the parking area should security become an issue in the future. The applicant is requesting a six foot chain link fence be added should a fence be placed on the site around the parking area. The applicant has indicated the days and hours of operation to be from 7:00 am to 7:00 pm six days per week. The applicant has also stated if the site is utilized as a meeting facility the hours would possibly extend to 10:00 pm but would not be utilized on a daily basis. The applicant has indicated the immediate user of the site would be a medical equipment sales and supply business, which has limited traffic to the site. The site will store medical equipment and deliver to the client’s home as phone sales are received. The applicant has indicated there are very few customers who actually access the site to view the equipment. The applicant has also requested alternative uses for the site including single user general and professional office users, real estate broker or real estate office use. Staff feels the requested uses would have minimal to no adverse impact on the area. Each of the requested uses also has limited customer traffic accessing March 11, 2004 SUBDIVISION ITEM NO.: 28 (Cont.) FILE NO.: Z-7579 5 the site and most of the sales activities take place off site. The applicant has also requested a meeting facility as an alternative use for the site. The proposed parking (6 spaces) is not sufficient to meet the typical minimum parking demand for a meeting facility. The typical minimum parking required for a meeting facility would be one space per one hundred square feet of gross floor area. Staff would recommend the applicant provide parking sufficient to meet the typical minimum parking demand for the use if redeveloped in this manner. The applicant has requested a deferral of the required street improvements until the site is redeveloped. Staff is supportive of this request. The applicant has indicated dedication of right-of-way per the Master Street Plan and staff feels the proposed change in use would not create a nexus for the required street improvements. The applicant has requested signage as a part of the proposed development located along West 11th Street. The proposed signage is consistent with signage allowed in office zones or a maximum of six feet in height and sixty-four square feet in area. Staff is supportive of the proposed signage and placement. The applicant has indicted cosmetic rehabilitation will be constructed on the building. The front façade will be removed and replace with a more attractive façade and front entrance. The overall building footprint will not change. Staff is supportive of this minor modification. To staff’s knowledge there are no outstanding issues associated with the proposed request. The applicant has indicated there is not a Bill of Assurance for the property that would prohibit the proposed development. The proposed use change, to a single-user office use, should have minimal to no adverse impact on the adjoining properties. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff recommends approval of the requested deferral of street improvements until redevelopment of the site. Staff recommends parking be provided for the alternative uses based on typical minimum parking requirements per the zoning ordinance. March 11, 2004 SUBDIVISION ITEM NO.: 28 (Cont.) FILE NO.: Z-7579 6 PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented the item with a recommendation of approval subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff also presented recommendations of approval of the requested deferral of street improvements until redevelopment of the site and that parking be provided for the alternative uses based on typical minimum parking requirements per the zoning ordinance. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 29 FILE NO.: Z-7580 NAME: Holleman Short-form PD-C LOCATION: 4115 Baseline Road DEVELOPER: Ronnie Holleman 4115 Baseline Road Little Rock, AR 72209 ENGINEER: Donald W. Brooks 20820 Arch Street Pike Hensley, AR 72065 AREA: 0.42 Acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 CURRENT ZONING: R-2, Single-family ALLOWED USES: Single-family Residential PROPOSED ZONING: PD-C PROPOSED USE: Single-family Residential and Truck Rental and Leasing VARIANCES/WAIVERS REQUESTED: None requested. A. PROPOSAL/REQUEST: The site contains an existing single-family structure being used as a home/office for Brothers A/C and Heating. In the past the applicant has operated a beauty/tanning salon at this location. The request is currently to allow the placement of five box moving vans for rental and lease. The existing office for the heating and air company will be used for the truck rental. A large portion of the front yard area has been constructed of a hard surface material. B. EXISTING CONDITIONS: The site contains a single-family home being used as a home office for the applicant’s heating and air business. The front yard area was previously covered with concrete. Other uses in the area included commercial and residential uses. March 11, 2004 SUBDIVISION ITEM NO.: 29 (Cont.) FILE NO.: Z-7580 2 There are single-family homes located to the east and south of the site. There is a large vacant O-3 zoned tract of land across Baseline Road. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. All residents who could be identified located within 300-feet of the site, the Cloverdale Neighborhood Association, the West Baseline Neighborhood Association, Southwest Little Rock United or Progress and all owners of property located within 200-feet of the site were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. No comment on proposed use change. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Entergy: Approved as submitted. Center-Point Energy: Approved as submitted. SBC: Approved as submitted. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all meter connections including any metered connections off a private fire system. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) or on site fire protection will be required. If additional fire facilities are required, they will be installed at the Developer's expense. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Approved as submitted. County Planning: No comment received. CATA: No comment received. March 11, 2004 SUBDIVISION ITEM NO.: 29 (Cont.) FILE NO.: Z-7580 3 F. ISSUES/TECHNICAL/DESIGN: Planning Division: This request is located in the Geyer Springs - East Planning District. The Land Use Plan shows Commercial for this property. The applicant has applied for a Planned Commercial Development for a truck rental business. The request does not require a change to the Land Use Plan. City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the Upper Baseline Neighborhood Action Plan. The plan does not list any goals, objectives, or actions statements relevant to this case. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) The applicant was not present. Staff stated there were few technical issues related to the site and staff had contacted the applicant to discuss the outstanding issues. Staff stated the request was for the placement of three to five box moving vans in the front yard of the existing residence/office. Staff stated the front yard area was currently paved. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant has indicated the placement of five moving vans on the site. The applicant has indicated the vans will be placed in the front yard area, which is currently paved of a hard surface material. The applicant has indicated the existing office used for the owner’s heating and air conditioning business will also act as the leasing office for the truck rental. The proposed site plan includes an asphalt parking area (66-feet by 87-feet). The site plan includes a setback on Baseline Road of 87-feet. The applicant has indicated the trucks will utilize the portion of the site near the existing structure (away from the road) to display the trucks. Staff is not supportive of the proposed request. Staff feels the proposed C-4 uses is not appropriate for the area. There are still a large number of single- family homes located to the east and south of the site and staff feels the placement of this intense use in this area will adversely impact the residents. March 11, 2004 SUBDIVISION ITEM NO.: 29 (Cont.) FILE NO.: Z-7580 4 There is an approved PD-C located to the west of the site for an existing welding shop. The use was a non-conforming use and the rezoning request was approved to recognize an existing use, not to add a new use to the area. The site has been used for commercial activities in the past all of which were indoor activities. Staff feels to add an outdoor activity to the site would not be in character with the neighborhood. The area is very diverse with large areas of open space located along Baseline Road. Staff feels the placement of this activity would be better served in an area not adjoining single-family homes. I. STAFF RECOMMENDATION: Staff recommends denial of the proposed request. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was not present. There were no registered objectors present. Staff stated the applicant had submitted a letter dated February 27, 2004 requesting the item be deferred to the March 25, 2004, 2004 Public Hearing. Staff stated they were supportive of the request. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 30 FILE NO.: Z-7581 NAME: Back Short-form POD LOCATION: 1111 Autumn Road DEVELOPER: Lawrence Back 6 Oakmont Court Little Rock, AR 72212 ENGINEER: Donald W. Brooks 20820 Arch Street Pike Hensley, AR 72065 AREA: 2.24 Acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 CURRENT ZONING: R-2, Single-family ALLOWED USES: Non-conforming Office and Warehouse Uses PROPOSED ZONING: POD PROPOSED USE: O-3 uses plus additional selected C-1 uses VARIANCES/WAIVERS REQUESTED: 1. Deferral of Master Street Plan improvements to Autumn Road and Kanis Road. 2. Deferral of construction of a hard surface parking for the site until redevelopment. The applicant submitted a letter dated February 27, 2004 requesting this item be deferred to the April 22, 2004 Public Hearing. Staff is supportive of this request. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was not present. There were no registered objectors present. Staff stated the applicant had submitted a letter dated February 27, 2004 requesting the item be deferred to the April 22, 2004 Public Hearing. Staff stated they were supportive of the request. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 31 FILE NO.: Z-7582 NAME: Gardner Short-form PD-R LOCATION: 705 Beechwood Street DEVELOPER: Steve Gardner 1109 North Polk Street Little Rock, AR 72205 ENGINEER: Donald W. Brooks 20820 Arch Street Pike Hensley, AR 72065 AREA: 0.25 Acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 CURRENT ZONING: R-5 ALLOWED USES: Multi-family residential at 36 units per acre PROPOSED ZONING: PD-R PROPOSED USE: Three-family Residence VARIANCES/WAIVERS REQUESTED: None requested. A. PROPOSAL/REQUEST: The applicant proposes to remove and rebuild an existing structure originally built as a single car garage and two separate storage units on the back northeast corner of the property located at 705 Beechwood Street. The applicant has indicted the current structure is in disrepair and not able to be used in it’s intended manner. The applicant proposes to replace the existing one level structure with a similar single car garage with three storage units on the first level and an additional living space in a new second level. The structure is proposed at 40 feet by 15 feet and sitting three feet from the northern property line. The applicant also has indicated a two-foot setback from the rear (east) property line. The existing garage is a front-loading garage but the applicant has indicated the new garage will be rear loaded accessed from the alley. The garage will provide parking for the above living space. March 11, 2004 SUBDIVISION ITEM NO.: 31 (Cont.) FILE NO.: Z-7582 2 The applicant has indicated in keeping with the architectural look of the main living structure (a duplex), the proposed garage apartment will be built in the same Arts and Craftsman style. The applicant has indicated the exterior of the new structure will be constructed of lap siding with a six-inch reveal. The roof will be red three tab shingles, which are consistent with the main structure. The windows will be vinyl double hung and the doors will be standard thirty inch six panel. B. EXISTING CONDITIONS: The site contains an existing duplex residence with a dilapidated garage located on the northeast property line. There is a functioning alley located to the rear of the structure and Beechwood Street is a standard Hillcrest Street with curb, gutter and sidewalk in place along the property frontage. The area contains a mix of uses from single-family to commercial. There is an apartment house located across Beechwood Street and single-family homes are located to the north and south of the home. There are single-family homes located to the east of the site, across the alley fronting Ash Street. The Hillcrest Shopping area is located just south of the site with a mix of residential, office and retail uses. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. All residents who could be identified located within 300-feet of the site, the Hillcrest Residents Neighborhood Association and all owners of property located within 200-feet of the site were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: No Comment. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Entergy: Approved as submitted. Center-Point Energy: Approved as submitted. SBC: Approved as submitted. March 11, 2004 SUBDIVISION ITEM NO.: 31 (Cont.) FILE NO.: Z-7582 3 Central Arkansas Water: Contact Central Arkansas Water at 992-2438 if larger and/or additional water meter(s) are required. Fire Department: Approved as submitted. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: This request is located in the Heights/Hillcrest Planning District. The Land Use Plan shows Multifamily for this property. The applicant has applied for a Planned Development - Residential for a new garage apartment and additional parking off the alley. The request does not require a change to the Land Use Plan. City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the Hillcrest Neighborhood Action Plan. The Zoning and Land Use chapter listed a goal of enforcing the city’s land-use and zoning policies to preserve the unique scale of the neighborhood. This application will allow the city to review the merits and impact of the applicant’s proposed development on the neighborhood. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) The applicant was not present. Staff briefly described the proposed request to the Committee members and stated there were very few outstanding issues associated with the proposed request and they had contacted the applicant to resolve those issues. The Committee questioned if the existing residence would be owner occupied. Staff stated this was not a requirement. Staff noted the requirement of owner occupation was related to R-2 and R-3 zoned properties not R-5 zoned property. Staff stated based on the available square footage of the lot the applicant would be entitled to develop the site with three units as proposed. There was no further discussion of the item and the Committee then forwarded the item to the full Commission for final action. March 11, 2004 SUBDIVISION ITEM NO.: 31 (Cont.) FILE NO.: Z-7582 4 H. ANALYSIS: The applicant has indicated the proposed structure will be located approximately three feet from the northern property line and two feet from the existing alleyway. The applicant has also indicated the garage will be rear loaded accessing the alley for entry. The site plan includes the placement of two additional parking spaces in the rear of the structure also accessed from the alley. There is one parking spaces located in the front of the structure accessed from Beechwood Street. The proposed development would typically require four parking spaces. The proposed parking is adequate to meet the typical minimum parking demand. The applicant has indicated the existing duplex structure will remain as such with the addition of the third living space above the newly constructed garage. The applicant has indicated the proposed new structure will be constructed of similar building materials as the existing structure located on the site in keeping with the architectural style of the area. The applicant has submitted a building elevation and staff recommends this elevation become a part of the approved site plan. The applicant has indicated there is not a Bill of Assurance in effect for the subdivision. Staff is supportive of the proposed development. The property is currently zoned R-5, Urban Residential District, which allows for development at a density of not more than thirty-six units per acre. The ordinance also requires the site to contain two thousand five hundred square feet of land area per dwelling unit. The applicant has a seventy-five by one hundred forty foot lot, adequate to meet this minimum lot area requirement. The applicant has indicated sufficient parking to meet the demand for three units and the applicant has not requested any signage as a part of the development. The proposed development will be in keeping with development in the area. The requested use is an allowable use under the current zoning. Staff feels the proposed development should have minimal to no adverse impact on the adjoining properties if developed in this manner. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff recommends the proposed building elevation become a part of the approved site plan. March 11, 2004 SUBDIVISION ITEM NO.: 31 (Cont.) FILE NO.: Z-7582 5 PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were no registered objectors present. Staff stated they had received two phone calls in support of the proposed request and to their knowledge there are no outstanding issues associated with the proposed request. Staff presented the item with a recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. Staff also presented a recommendation that the proposed building elevation become a part of the approved site plan. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 32 FILE NO.: Z-7583 NAME: Marshall Short-form PD-R LOCATION: 5045 Stanley Drive DEVELOPER: Donald Marshall 8419 Baseline Road. Little Rock, AR 72209 ENGINEER: Terry Burrus Architects 1202 South Main Street Little Rock, AR 72202 AREA: 0.16 Acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 CURRENT ZONING: R-5 ALLOWED USES: Multi-family development at 36-units per acre PROPOSED ZONING: PD-R PROPOSED USE: Private laundry facility to serve existing multi-family development. VARIANCES/WAIVERS REQUESTED: None requested. A. PROPOSAL/REQUEST: The applicant proposes the construction of a private laundry facility on this existing vacant lot. The laundry facility will serve the existing apartment units located on Stanley Drive; owned by the applicant. The applicant has indicated a means of security will be added to the facility either through a card swipe or a keypad entry to further ensure only residents of the apartment development may have access to the laundry facility. The proposed site plan indicates a fenced area to the rear and future construction of a maintenance building. The applicant has indicated there will be no outdoor storage of any type related to repair of the existing units or equipment necessary for upkeep of the units. March 11, 2004 SUBDIVISION ITEM NO.: 32 (Cont.) FILE NO.: Z-7583 2 B. EXISTING CONDITIONS: The site is vacant with two drives leading to a previously constructed foundation. The site appears to once have housed a duplex unit as is common in the area. The north side of Stanley Drive has apartment units in four-plex and eight-plex style; the south side of Stanley Drive has duplex style units. Stanley Drive was previously a through street but now does not connect because the Board of Directors allowed the placement of bollards to stop through traffic. This was put in place as a crime deterrent several years ago. Other uses in the area include single-family to the south and multi-family to the north. There is a large area of vacant land located to the east of the proposed laundry facility appearing to once have been residences and at some point leveled and never reconstructed. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents concerning the proposed use. All residents who could be identified located within 300-feet of the site, Southwest Little Rock United for Progress and all owners of property located within 200-feet of the site were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. Sidewalks with appropriate handicap ramps are required. 2. Under the traffic access and circulation requirements of Sections 30-43 and 31-210, only one drive apron would be allowed. The other apron must be removed as part of the construction. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer available, not adversely affected. Entergy: No comment received. Center-Point Energy: Approved as submitted. SBC: Approved as submitted. March 11, 2004 SUBDIVISION ITEM NO.: 32 (Cont.) FILE NO.: Z-7583 3 Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZA) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact Carroll Keatts at 992-2431 if you would like to discuss backflow prevention requirements for this project. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Place fire hydrants per code. Contact the Little Rock Fire Department at 918-3752 for additional details. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: This request is located in the Geyer Springs - East Planning District. The Land Use Plan shows Single Family for this property. The applicant has applied for a Planned Development - Residential to add a private laundry facility to serve existing multifamily units. The request does not require a change to the Land Use Plan. City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the Upper Baseline Neighborhood Action Plan. The plan does not list any goals, objectives, or actions statements relevant to this case. Landscape: The plan submitted fails to provide the minimum nine (9) foot wide land use buffer and perimeter landscape strips along the southern, eastern, and western property lines. A six (6) foot high opaque screen, either a wall, or wooden fence with its face side directed outward, or dense evergreen plantings, is required along the southern, eastern, and western perimeters of the site. March 11, 2004 SUBDIVISION ITEM NO.: 32 (Cont.) FILE NO.: Z-7583 4 G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) The applicant was not present. Staff stated they had met with the applicant prior to the Subdivision Committee meeting to discuss outstanding issues. Staff stated the request was to place a private laundry facility on the site to serve an existing apartment development. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plan to staff addressing most of the concerns raised. The applicant has removed one of the drives located along the eastern portion of the site and located a sidewalk to access the proposed mail kiosk located on the east side of the building. The applicant is requesting the western drive remain to access the rear of the site. The applicant has indicated future construction of a maintenance building enclosed within a six-foot fence. The applicant has indicated the maintenance building will be constructed for storage and repairs. The applicant has indicated there will be no outdoor storage of lumber, appliances or any other items within this area. The applicant has indicated the drive will be marked and signed for no parking to further ensure residents only are utilizing the facility. The applicant has indicated the site will be secured by a card swiping or keypad access code security method. The applicant will install this means to secure the site limiting the use of the facility to residents only. The proposed request is consistent with other multi-family developments, which provide a laundry facility to meet the needs of their residents. The applicant has not requested signage as a part of the development, further indicating his desire for the facility to be used by residents only. The applicant has indicated only wall signage will be utilized indicating the facility as a private facility to serve the residents of the adjoining apartments. The applicant has indicated there is not a Bill of Assurance that would prohibit the proposed development. Staff is supportive of the request. The applicant has worked to minimize concerns of staff. Staff feels the proposed request should have minimal to no adverse impact on the adjoining properties. The request for a private laundry facility to serve the residents of the nearby apartments owned by the applicant is consistent with other developments providing on-site laundry facilities. To staff’s knowledge there are no outstanding issues associated with the proposed request. March 11, 2004 SUBDIVISION ITEM NO.: 32 (Cont.) FILE NO.: Z-7583 5 I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Terry Burruss was present representing the request. There were no registered objectors present. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented the item with a recommendation of approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 33 FILE NO.: LU04-18-01 Name: Land Use Plan Amendment - Ellis Mountain Planning District Location: North of Kanis Road, southeast of Pride Valley Road Request: Single Family to Suburban Office Source: Bill Greenwood PROPOSAL / REQUEST: Land Use Plan amendment in the Ellis Mountain Planning District from Single Family to Suburban Office. The Suburban Office category provides for low intensity development of office or office parks in close proximity to lower density residential areas to assure compatibility and require a Planned Zoning District. The applicant wishes to convert an existing structure into an office. Prompted by this Land Use Amendment request, the Planning Staff expanded the area of review to include area north to the proposed Pride Valley Road extension to link the application area to the area shown as Suburban Office north of the applicant’s property. EXISTING LAND USE AND ZONING: The property is a house on a large lot currently zoned R-2 Single Family and O-2 Office and Institutional District and is .65 acres ± in size. The expanded area is zoned O-2 on Kanis at the proposed Pride Valley extension. The land to the north consists of vacant land along Kanis Road zoned O-2 Office and Institutional along both sides of Kanis Road while the land to the east is zoned R-2 for houses located on both sides of Pride Valley Road. The land to the south and west consists of large lot single-family homes on Kanis Road and a Conditional Use Permit for the Baker Elementary School southwest of the applicant’s property. FUTURE LAND USE PLAN AND RECENT AMENDMENTS: On June 17, 2003 a change was made from Single Family & Multifamily to Low Density Residential at the end of Wellington Hills Road about 1 mile northwest of the area in question to accommodate proposed development. On July 3, 2001 a change was made from Low Density Residential, Mixed Office March 11, 2004 SUBDIVISION ITEM NO.: 33 (Cont.) FILE NO.: LU04-18-01 2 Commercial, and Neighborhood Commercial to Single Family in an area bounded by Bowman Road, Panther Creek, Cooper Orbit Road, and Brodie Creek starting about 1 mile south of the applicant’s property to recognize existing conditions. On February 15, 2000 a change was made from Single Family to Low Density Residential on West Glen Drive and Gamble Road about 1 mile southeast of the application area to accommodate proposed development. On January 4, 2000 a change was made from Office to Mixed Office Commercial at 15500 Chenal Parkway about a ½ mile northwest of the study area to accommodate proposed development. The applicant’s property is shown as Single Family on the Future Land Use Plan. The land to the north is shown as Suburban Office, while the land to the east and south is shown as Single Family. The land to the west is shown as Public Institutional. The area shown as Suburban Office at 15500 Chenal Parkway located less that ¼ of a mile northwest of the application area is under consideration by the Planning Commission for a change to Commercial. MASTER STREET PLAN: Kanis Road is shown on the Master Street Plan as a Minor Arterial and would be subject to half street improvements in order to conform to the Master Street Plan. Pride Valley Road is shown as a Collector street with a Proposed Collector shown to connect the completed portion of Pride Valley Road to Kanis Road. Pride Valley Road east of the applicant’s property is built to Master Street Plan standards but ends at a dead end along the northern boundary of the study area. There are no bikeways shown that would be affected by the proposed Land Use Plan Amendment. PARKS: The Little Rock Parks and Recreation Master Plan of 2001 includes public school property, such as the Baker Elementary School located across the street southwest of the applicant’s property, as an element in the eight-block strategy of providing park and open space facilities within eight blocks of all residents of the City of Little Rock. HISTORIC DISTRICTS: There are no city recognized historic districts that would be affected by this amendment. March 11, 2004 SUBDIVISION ITEM NO.: 33 (Cont.) FILE NO.: LU04-18-01 3 City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the Rock Creek Neighborhood Action Plan. The Office and Commercial Development goal seeks to maintain the residential integrity of the neighborhood with the objective of adhering to the Future Land Use plan and lists an action statement of requiring developments in the neighborhood to adhere to the Future Land Use plan. ANALYSIS: This application would result in the expansion of Suburban Office already shown to the north of Kanis Road. The possibility for the expansion of the area shown as Suburban Office on the opposite side of Kanis Road is limited by the Public Institutional shown for Baker Elementary School to the south and the area shown as Park / Open Space shown for the Rock Creek floodplain to the north. If the Pride Valley Extension were built, the properties at Kanis and Pride Valley would face pressure to develop for non-residential uses. A change to Suburban Office would allow non-residential uses at the potential intersection, protect the integrity of the residential area to the east, and avoid more intense non-residential development in close proximity to the school. The close proximity of this application area would be affected by the proposed change from Suburban Office to Commercial located at 15500 Chenal Parkway. If approved, the amendment on Chenal Parkway would reduce the area shown as Suburban Office by about 13.5 + acres. Currently 24.42 + acres are shown as Suburban Office with 14.92 + acres on the north side and 9.5 + acres on the south side of the road. The reduction in acreage would result in 1.42 + acres on the north side and leave the 9.5 + on the south side for a new total of 10.92 + acres of Suburban Office shown. If both amendments are approved the total amount of Suburban Office shown on Kanis and Pride Valley Road would be 19.79 + acres. If the proposed change to Suburban Office is approved and the adjacent proposed change to Commercial is not approved, the total acreage shown as Suburban Office would be 33.29 + with a gain of 8.87 + acres. Since most of the amendment area is already zoned O-2, this change would partially reflect existing conditions. NEIGHBORHOOD COMMENTS: Notices were sent to the following neighborhood associations: Gibraltar/Pt. West/Timber Ridge, Parkway Place Property Owners Association, Spring Valley Manor Property Owners Association, Carriage Creek Property Owners March 11, 2004 SUBDIVISION ITEM NO.: 33 (Cont.) FILE NO.: LU04-18-01 4 Association, St. Charles Property Owners Association, SW Little Rock UP, and WCLR Coalition of Neighborhoods. Staff has not received comments from area residents or Neighborhood Associations. STAFF RECOMMENDATIONS: Staff believes the change is appropriate. This amendment will recognize existing zoning and protect the integrity of the Single Family uses to the east. PLANNING COMMISSION ACTION: (March 11, 2004) The item was placed on the consent agenda for approval. A motion was made to approve the consent agenda and was approved with a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 33.1 FILE NO.: Z-7584 NAME: G & S Builders Short-form PD-O LOCATION: North of Kanis Road, Southeast of Pride Valley Road DEVELOPER: G & S Builders 2723 Foxcroft Suite 104 Little Rock, AR 72205 ENGINEER: McGetrick and McGetrick Engineers 319 President Clinton Avenue, Suite 202 Little Rock, AR 72201 AREA: 0.65 Acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 CURRENT ZONING: R-2, Single-family ALLOWED USES: Single-family residential PROPOSED ZONING: PD-O PROPOSED USE: General contractors office – with no outdoor storage VARIANCES/WAIVERS REQUESTED: None requested. A. PROPOSAL/REQUEST: The applicant proposes the conversion of an existing single-family structure to an office use for a general contractor as his primary office without outdoor storage of equipment or supplies. A 52-foot by 24-foot garage will be added to the rear of the structure connected with a covered breezeway. The applicant is also proposing the placement of six outdoor parking spaces in the rear of the structure and two parking spaces in the front of the structure. A gate will be added to the site to secure the rear of the site. A six-foot wood fence will be added along the perimeter of the site to screen and secure the site. The applicant has indicated six to eight employees and the days and hours of operation from 7:00 am to 6:00 pm Monday through Saturday. The applicant is requesting general and professional office uses as alternative uses March 11, 2004 SUBDIVISION ITEM NO.: 33.1 (Cont.) FILE NO.: Z-7584 2 for the site. The proposed garage will be utilized as parking and limited storage of materials. The applicant has indicated a single ground mounted sign located in the front yard area consistent with signage allowed in office zones. B. EXISTING CONDITIONS: The site contains an existing single-family structure with a single access from Kanis Road. The development is this area is very rural in character. There is a single-family home located to the east of the site also accessed from Kanis Road. There are single-family homes located to the north of the site in the Parkway Place/Wood Creek Neighborhoods. Vacant O-2 zoned property is located to the west of the site. To the south of the site is a non-conforming gun shop and Baker Elementary School is located to the southeast. Kanis Road is an unimproved roadway in this area with no sidewalks and open ditches for drainage. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has received one informational phone call from an area resident concerning the proposed use of the property. All residents who could be identified located within 300-feet of the site, the Parkway Place Neighborhood Association and all owners of property located within 200-feet of the site were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer main extension required, with easements, if service is required for the project. Contact Little Rock Wastewater Utility at 688-1414 for additional details. Entergy: Provide a 15-foot easement from the property line. (Center of pole to outside conductor is 5-feet plus OSHA 10-foot minimum clearance adds to 15-feet from property.) Contact Entergy for additional details. Center-Point Energy: Approved as submitted. March 11, 2004 SUBDIVISION ITEM NO.: 33.1 (Cont.) FILE NO.: Z-7584 3 SBC: No comment received. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request for water service must be met. A Capital Investment Charge based on the size of connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. A Capital Investment Charge based on the size of the meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all meter connections including any metered connections off the private fire system. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Contact Central Arkansas Water at 992-2438 for additional information. Fire Department: Approved as submitted. County Planning: No comment received. CATA: No comment received. F. ISSUES/TECHNICAL/DESIGN: Planning Division: This request is located in the Ellis Mountain Planning District. The Land Use Plan shows Single Family for this property. The applicant has applied for a Planned Office Development for conversion of an existing structure into an office. A land use plan amendment for a change to Suburban Office is a separate item on this agenda (Item No. 33 – File No. - LU04-18-01). City Recognized Neighborhood Action Plan: The applicant’s property lies in the area covered by the Rock Creek Neighborhood Action Plan. The Office and Commercial Development goal seeks to maintain the residential integrity of the neighborhood with the objective of adhering to the Future Land Use plan and lists an action statement of requiring developments in the neighborhood to adhere to the Future Land Use plan. Landscape: The northern perimeter landscape strip width falls short of the minimum six foot nine inch (6 foot-9inch) width allowed. March 11, 2004 SUBDIVISION ITEM NO.: 33.1 (Cont.) FILE NO.: Z-7584 4 A six (6) foot high opaque screen, either a wall, or wooden fence with its face side directed outward, or dense evergreen plantings, is required along the southern perimeter of the site. G. SUBDIVISION COMMITTEE COMMENT: (February 19, 2004) Mr. Pat McGetrick was present representing the request. Staff presented an overview of the proposed development indicating additional items were necessary to complete the review process. Staff requested the applicant provide additional information concerning the proposed location of any dumpster, fencing and outdoor storage. Mr. McGetrick stated there would not be any outdoor storage on the site. He stated the only storage proposed was limited storage within the proposed garage. Public Works comments were addressed. Staff noted a dedication of right-of- way to meet the Master Street Plan requirements would be required. Staff stated a dedication of 45-feet from centerline would be required. Landscape comments were addressed. Staff stated perimeter landscaping of a minimum of six feet and nine inches would be required along the northern perimeter of the site. Staff also noted screening would be required along the southern perimeter. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plan to staff addressing most of the issues raised at the February 19, 2004 Subdivision Committee meeting. The applicant has indicated a seven-foot landscaping strip along the northern perimeter of the site sufficient to meet the minimum requirement of six feet nine inches. The applicant has also indicated a six-foot wood fence along the perimeter of the site to act as screening and security for the site. The proposed site plan includes a gate located along the northern portion of the site near the front corner of the building. The applicant has indicated the gate will be added for security. The applicant has indicated eight on-site parking spaces and the addition of a 52-foot by 24-foot garage. The applicant has indicated four parking spaces will be located in the garage and the garage will also be used for limited storage of materials. The applicant has indicated there will not be any outdoor storage of materials or equipment on the site. The entire rear of the site will remain grass covered and a buffer for the adjoining single-family properties. March 11, 2004 SUBDIVISION ITEM NO.: 33.1 (Cont.) FILE NO.: Z-7584 5 The applicant has indicated there are six to eight employees of the company. The proposed parking (twelve parking spaces) is sufficient to meet the typical minimum parking demand for an office building. Based on a total square footage of the existing structure a total of six parking spaces would typically be required if developed as an office use. Staff feels the proposed parking is adequate to meet the typical minimum parking demand. The applicant is proposing the placement of a single ground mounted sign located in the front yard area. The proposed sign is consistent with signage allowed in office zones or a maximum of six feet in height and sixty-four square feet in area. Staff is supportive of the proposed signage. The proposed site plan indicates a dedication of 20-feet of additional right-of-way adequate to meet the minimum requirement of the Master Street Plan for a Minor Arterial Street. To staff’s knowledge there are no outstanding issues associated with the proposed request. The applicant has indicated landscaped areas sufficient to meet the minimum ordinance requirements and screening placed to protect adjoining single-family zoned properties. The applicant has also indicated dedication of right-of-way sufficient to meet the Master Street Plan requirement. Staff is supportive of the proposed development. The site adjoins O-2 zoned property to the north and staff feels the proposed low intensity office use would act as a buffer and have limited to no adverse impact on the adjoining properties. I. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Pat McGetrick was present representing the request. There were no registered objectors present. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented the item with a recommendation of approval of the request subject to compliance with the conditions outlined in paragraphs D, E and F of the above report. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 34 FILE NO.: Z-7585 NAME: The River Tower Long-form PD-R LOCATION: On the Northeast corner of River Bend Road and River Front Drive DEVELOPER: The Hathaway Group 1001 North University Avenue Little Rock, AR 72207 ENGINEER: White-Daters and Associates #24 Rahling Circle Little Rock, AR 72223 AREA: 3.2 Acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 CURRENT ZONING: O-3, General Office ALLOWED USES: General Office PROPOSED ZONING: PD-R PROPOSED USE: Twelve Story Residential Condo Development (50 - Units Total) VARIANCES/WAIVERS REQUESTED: None requested. The applicant submitted a letter dated February 23, 2004, requesting this item be deferred to the April 22, 2004 Public Hearing to allow additional time for final design of the building and to provide building elevations. Staff is supportive of this request. PLANNING COMMISSION ACTION: (MARCH 11, 2004) Mr. Joe White was present representing the request. There were registered objectors present. Staff stated the applicant submitted a letter dated February 23, 2004, requesting the item be deferred to the April 22, 2004 Public Hearing to allow additional time for final design of the building and to provide building elevations. Staff stated they were supportive of the requested deferral. March 11, 2004 SUBDIVISION ITEM NO.: 34 (Cont.) FILE NO.: Z-7585 2 There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 35 FILE NO.: Z-4175-G NAME: Arkansas Hospice Long-form POD Time Extension Request LOCATION: At the North end of Dover Drive, West of 36th Street DEVELOPER: Arkansas Hospice 2200 Fort Roots Drive North Little Rock, AR 72114-1709 ARCHITECT: Witsell Evans Rasco 901 West 3rd Street Little Rock, AR 72201 AREA: 9.7 Acres NUMBER OF LOTS: 1 FT. NEW STREET: 110 L.F. (cul-de-sac) CURRENT ZONING: POD ALLOWED USES: Arkansas Hospice Facility BACKGROUND: On August 1, 1995, the Board of Directors adopted Ordinance No. 16,939 rezoning the site from MF-18 to POD for development of the Hospice Home Care (Arkansas Hospice) facilities. The multiple building site plan included the following: x office building x two (2) impatient care facility buildings x chapel building x childcare building x medical equipment building x grounds maintenance building x future additional impatient care facility building site x 122 parking spaces No development began during the official time frame for submission of a final development plan and the previously approved POD officially expired. On April 19, 2001, the Little Rock Planning Commission reviewed a request to reestablish the POD zoning for the site and to allow the development to take place as a March 11, 2004 SUBDIVISION ITEM NO.: 35 (Cont.) FILE NO.: Z-4175-G 2 two-phase development. As was previously requested, the applicant proposed to develop the site to accommodate residential inpatient care for the terminally ill. The phases included the development of Arkansas Hospice Offices (21,406 square feet) and an inpatient care facility (24,385 square feet and 20 beds). The second phase of the development included construction of an additional 21,000 square foot inpatient care facility (20 beds) a chapel and maintenance building. The applicant indicated all building design would be residential in character. The Little Rock Board of Directors approved the proposed development plan by the adoption of Ordinance No. 18,497 on June 5, 2001. A. PROPOSAL/REQUEST: The applicant submitted a letter dated January 12, 2004, requesting an extension be granted for submission of the final development plan. The applicant has indicated for the project to be successful, significant economic and regulatory goals must be attained. The applicant has indicated these goals will require additional time to accomplish. As per Section 36-454(e) of the Code, the applicant shall have three years from the date of passage of the ordinance approving the preliminary approval to submit the final development plan. Requests for extension of time shall be submitted in writing to the Planning Commission, which may grant extensions of not more than two years. The applicant has requested the maximum time extension allowed by ordinance or a two-year time extension. B. EXISTING CONDITIONS: The property is undeveloped and wooded. There is a church to the south along the west side of Dover Drive and single-family residences along the east side of this street. There is undeveloped MF-12 zoned property to the north, with the Good Shepard nursing home facility further north along Aldersgate Road. There is a lake and the Kensington Place Neighborhood immediately east of the site. The Our Way, Inc. independent living facilities are located to the west. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. The John Barrow, Kensington Place and Sewer District #147 Neighborhood Associations were notified of the public hearing. March 11, 2004 SUBDIVISION ITEM NO.: 35 (Cont.) FILE NO.: Z-4175-G 3 D. STAFF RECOMMENDATION: Staff recommends approval of the requested two (2) year time extension. All previous conditions, comments and recommendations will continue to be in effect for the POD. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were no registered objectors present. Staff stated to their knowledge there are no outstanding issues associated with the proposed request. Staff presented the item with a recommendation of approval of the requested two (2) year time extension. Staff stated all previous conditions, comments and recommendations will continue to be in effect for the POD. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 36 FILE NO.: Z-4923-A NAME: Summit Mall Revised PCD Time Extension Request LOCATION: On the Southwest corner of Shackleford Road and I-430 DEVELOPER: Summit Mall Co., LLC & Construction Developers, Inc. c/o Simon Development Group 115 West Washington Street Indianapolis, IN 46204 ENGINEER: McGetrick and McGetrick Engineers 319 President Clinton Avenue, Suite 202 Little Rock, AR 72201 AREA: 97 Acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 CURRENT ZONING: PCD ALLOWED USES: Commercial – Shopping Mall The applicant submitted a letter dated February 24, 2004, requesting this item be withdrawn from consideration. Staff is supportive of this request. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were no objectors present. Staff presented the item indicating the applicant had submitted a letter dated February 24, 2004, requesting this item be withdrawn from consideration. Staff stated they were supportive of the request. Ms. Kathlean Oleson representing the League of Women’s Voters of Pulaski County questioned the zoning status of the proposed site. Ms. Cindy Dawson, Deputy City Attorney, stated she was unable to answer the question at this time. She stated the site had been under litigation and she was not one of the litigator’s for the case. She stated she would have to defer all question to Mr. Tom Carpenter, City Attorney. Ms. Olsen stated once Mr. Carpenter had completed his review she felt the decision should be made public through announcement at a Board of Directors meeting or a Planning Commission Public Hearing. March 11, 2004 SUBDIVISION ITEM NO.: 36 (Cont.) FILE NO.: Z-4923-A 2 There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent. March 11, 2004 ITEM NO.: 37 FILE NO.: Z-4454-A NAME: Miller Short-form PCD Revocation Request LOCATION: 15122 Cantrell Road DEVELOPER: Charles Enoch Miller 14116 Taylor Loop Road Little Rock, AR 72223 ENGINEER: White-Daters and Associates 24 Rahling Circle Little Rock, AR 72223 AREA: 1.29 Acres NUMBER OF LOTS: 0 FT. NEW STREET: 1 CURRENT ZONING: POD ALLOWED USES: Cosmetology School and Single-family Residential PROPOSED ZONING: R-2, Single-family PROPOSED USE: Single-family residential VARIANCES/WAIVERS REQUESTED: None requested. BACKGROUND: Ordinance No. 18,564 adopted by the Little Rock Board of Directors on September 18, 2001, rezoned the site from R-2, Single-family to POD (Planned Office Development), which would allow the applicant to utilize one of the existing structures as a cosmetology school. The applicant proposed to use the westernmost structure as the school, and continue to use the smaller eastern structure as a single-family residence. A. PROPOSAL/REQUEST: The applicant submitted a request dated January 13, 2004, requesting the current zoning be revoked and the previous R-2, Single-family zoning classification be restored. The applicant has indicated the proposed March 11, 2004 SUBDIVISION ITEM NO.: 37 (Cont.) FILE NO.: Z-4454-A 2 cosmetology school previously approved will not be developed on this site and has requested the existing POD zoning classification be revoked and the original R-2, Single-family zoning classification be restored. Currently both structures on the site are rented as single-family units. The previous approval for the cosmetology school did not list single-family as an allowable use. The applicant is requesting the zoning change to allow both structures to be marketed as single-family uses. B. EXISTING CONDITIONS: There are two (2) existing single-family residential structures on the site, with two (2) access points from Cantrell Road. There is an undeveloped R-2 zoned property to the north and west, with Rummell Road further west. There are single-family residences across Cantrell Road to the south. There are office uses (POD’s) to the east along the north side of Cantrell Road. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area residents. The Westchester/Heatherbrae and Secluded Hills Neighborhood Associations and all owners of property located within 200-feet of the site were notified of the public hearing. D. STAFF RECOMMENDATION: Staff recommends approval of the request for the revocation of the current POD zoning classification and the restoration of the zoning classification to R-2, Single-family. PLANNING COMMISSION ACTION: (MARCH 11, 2004) The applicant was present representing the request. There were no registered objectors present. Staff presented the item indicating to their knowledge there are no outstanding issues associated with the proposed request. Staff presented a recommendation of approval of the request for the revocation of the current POD zoning classification and the restoration of the zoning classification to R-2, Single-family. There was no further discussion of the item. The item was placed on the Consent Agenda and approved as presented by staff by a vote of 9 ayes, 0 noes and 2 absent.