HomeMy WebLinkAboutpc_02 09 2023
LITTLE ROCK PLANNING COMMISSION
SUMMARY AND MINUTE RECORD
FEBRUARY 9, 2023
4:00 P.M.
I. Roll Call and Finding of a Quorum
A Quorum was present there being eleven (11) members present.
II. Members Present: Harold Betton
Jimmy Brown
Todd Hart
Marlon D. Haynes
Kat Hodge
Paul Latture
Alicia McDonald
Diana M. Thomas
Michael Vickers
Robby Vogel
Pamela Whitaker
Members Absent: None
City Attorney: Shawn Overton
III. Approval of the Minutes of the January 12, 2023 Meeting of the Little Rock
Planning Commission. The Minutes were approved as presented.
LITTLE ROCK PLANNING COMMISSION
AGENDA
FEBRUARY 9, 2023
OLD BUSINESS:
Item Number: File Number: Title:
A. Z-5502-J West Kanis Storage – Revised PD-C
West of 17301 Kanis Road
B. Z-9739 Love Family Care Facility – Special Use Permit
5918 Drexel Avenue
C. Z-9747 York Accessory Dwelling – Conditional Use Permit
319 S. Valmar Street
D. Z-9746 Rivera Event Center – Conditional Use Permit
7521 Geyer Springs Road
E. Z-9535-A Ranch Creek Townhomes – PD-R
West side of Tulley Cove, North of 16,100 Cantrell Road
NEW BUSINESS:
Item Number: File Number: Title:
1. S-1914-A Lot 1, O. Jack Hartsell III, Inc. Subdivision – Replat
7100 Beck Road
2. Z-9751 Masterminds Real Estate, LLC Duplex – Conditional Use
Permit
1914 Dennison Street
3. Z-9755 HCS, Inc. Duplexes – Conditional Use Permit
Northwest corner of West 46th Street and Foster Street
4. Z-7500-I Hamilton Station – POD
North of 14800 Cantrell Road
Agenda, Page Two
NEW BUSINESS: (Continued)
Item Number: File Number: Title:
5. Z-4156-C GSBC – Hair Salon – PDC
5901 West 57th Street
6. Z-5817-L Cantrell West Retail Center – PCD
15122 Cantrell Road
7. Appeal of Lots 33R and 34R, Grandview Addition –
Lot Recombination
5120 / 5200 Grandview Street
February 9, 2023
ITEM NO.: A FILE NO.: Z-5502-J
NAME: West Kanis Storage – Revised PD-C
LOCATION: 17301 Kanis Road
DEVELOPER:
Tisdale Properties & Development
43 Chenal Circle
Little Rock, AR 72223
OWNER/AUTHORIZED AGENT:
Olan Asbury (Agent)
P.O. Box 241087
Little Rock, AR 72223
SURVEYOR/ENGINEER:
White-Daters Engineers
24 Rahling Circle,
Little Rock, AR 72223
AREA: 13.54 NUMBER OF LOTS: 2 FT. NEW STREET: 0 LF
WARD: N/A PLANNING DISTRICT: 18 CENSUS TRACT: 42.25
CURRENT ZONING: PD-C (Planned Development – Commercial)
VARIANCE/WAIVERS: None requested.
BACKGROUND:
On November 8, 2021 the Planning Commission approved zoning the property from R-2
to PD-C including a waiver for the required ½ street improvements to Kanis Road. The
Board of Directors approved the PD-C request on January 18, 2022. The previously
approved PD-C development included 11 mini-warehouse buildings and an office building
with associated parking and access from Kanis Road.
February 9, 2023
ITEM NO.: A (Cont.) FILE NO.: Z-5502-J
2
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant proposes to revise the PD-C for the property located at 17301 Kanis
Road to allow the development of an additional 8.26 acres to the west to include
seven (7) additional mini-warehouse buildings and additions to two (2) of the
previously approved mini-warehouse buildings.
B. EXISTING CONDITIONS:
The site is vacant and cleared of structures and trees. A single driveway along the
northeast edge of the property provides access from Kanis Road. A centrally
located pond covers a good portion of the eastern section of the site from north to
south and drains into a creek running southeast serving as a tributary to Rock
Creek. The creek runs North to south parallel to the pond dividing the western
portion of the site. Properties to the north and east of the development includes
commercial, and office use zoned uses and properties to the south and west
include residential uses. The property to the north directly across Kanis Road
owned by Entergy, zoned R-2 and O-2 and includes electrical transmission lines
traversing in a north/south direction.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 200 feet of the site and all neighborhood
associations registered with the City of Little Rock were notified of the public
hearing.
D. ENGINEERING COMMENTS:
1. Provide finished floor elevations (FFE) for all buildings on site plan and
grading and drainage plans.
2. Show all flood plain boundaries and flood zones on site plan and grading and
drainage plans.
3. A grading permit must be obtained prior to initiation of work. Grading permits
are issued by the Planning and Development Dept. at 723 West Markham
Street after approval of sediment and erosion control plans, grading and
drainage plans, land survey, drainage study, and soil loss calculations per
City’s stormwater management and drainage manual. Contact Planning and
Development Dept., Civil Engineering Private Development at 501-371-4817
or at 501-918-5348 or Permits@littlerock.gov to schedule an appointment for
issuance or to answer any questions. Permit cost is based on total project
area at $100.00 for the less than ½ acre, $200.00 for ½ to 1 acre, and $200.00
for the first acre and $100.00 for each additional acre for project greater than
1 acre.
February 9, 2023
ITEM NO.: A (Cont.) FILE NO.: Z-5502-J
3
4. Any work involving one (1) or more acres of disturbed area requires a State
of Arkansas NPDES permit. Contact the Arkansas Department of
Environmental Quality, NPDES branch at 501-682-0744 for applications and
information about General Stormwater Discharge Construction Permit
#ARR150000.
5. Damage to public and private property due to hauling operations or
operations of construction related equipment from a construction site shall be
repaired by the responsible party prior to the issuance of a certificate of
occupancy.
6. Provide as-built plans and data entry template of newly installed or modified
public and private stormwater drainage system prior to issuance of the
certificate of occupancy. The as-built plans should contain information as
found on the City of Little Rock website at https://www.littlerock.gov/city-
administration/city-departments/public-works/applications-details-and-
manuals/. Provide the as-built plans and data entry template to Planning
and Development Dept., Civil Engineering Private Development by email to
csmith@littlerock.gov and cc dwarner@littlerock.gov. If you have any
questions or desire additional information, please do not hesitate to contact
Planning and Development Dept., Civil Engineering Private Development at
501-371-4817 or at 501-918-5348 or email Permits@littlerock.gov.
7. A maintenance bond for 50% of total construction costs for all completed
public street and drainage improvements within City right of way and as-built
storm drainage infrastructure plans shall be provided to the Department of
Planning and Development before the issuance of a final certificate of
occupancy.
8. A drainage study showing all hydrologic and hydraulic calculations for the
proposed storm sewer pipe system, detention ponds and structures, and
inlets is required. For final drainage report, sign, date, and seal the report per
AR State Board of Professional Engineers and Professional Surveyors rules
Article 12, Section B (1) (a). Provide engineer's certification statement saying
this drainage report was conducted by yourself or directly under your
supervision and attesting to the accuracy of the information within this report.
9. Per City Rev. Code 29-99, stormwater detention for developments
is required. Provide stormwater detention infrastructure to satisfy this
requirement.
10. The Department requires three (3) phase sediment and erosion control (SEC)
plans to be submitted for all construction projects showing best management
practices (BMPs) for mitigating sediment runoff and erosion along with
vegetation specifications for temporary and permanent soil stabilization.
Phase 1 SEC plans shall show SEC BMPs during the stripping, clearing,
grubbing, and rough grading of the site. Phase 2 SEC plans shall show SEC
February 9, 2023
ITEM NO.: A (Cont.) FILE NO.: Z-5502-J
4
BMPs during construction of utilities, buildings, roadway infrastructure and
drainage infrastructure. Phase 3 SEC Plans shall show SEC BMPs for final
grading, seeding, and landscaping of the site.
11. Sediment and Erosion Control plans shall also show the pertinent information
as outlined in ADEQ ARR150000 Permit Part II section A-4-H (1-14) and Part
II section A-4-I-2 (A-B).
12. A Special Flood Hazard Development Permit (SFHA) is required to be
obtained to prior to beginning construction. Contact Pulaski County Planning
and Development Department’s floodplain administrator at 501-340-8265
(3200 Brown Street Little Rock, AR 72204) to obtain a SFHA permit.
13. Due to the proposed structures being located within the 100-year floodplain,
an elevation certificate of the finished floor elevation for each structure must
be provided to the Pulaski County Planning & Development Department’s
floodplain administrator prior to the issuance of a certificate of occupancy.
Contact Pulaski County Planning and Development Department’s floodplain
administrator at 501-340-8265 (3200 Brown Street Little Rock, AR 72204).
14. Development or fill within the floodway is prohibited. Contact Pulaski County
Planning and Development Department’s floodplain administrator at
501-340-8265 (3200 Brown Street Little Rock, AR 72204) to verify
compliance with Pulaski County’s flood hazard damage prevention and
control ordinances and codes. Dedication of additional right of way per City’s
master street plan for a minor arterial will be required for future boundary
street improvements.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: Submit plans and specifications for
proposed sewer infrastructure to LRWRA for review and approval.
Entergy: No comments received.
Summit Utilities: No comments.
AT & T: No comments received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
2. Please submit plans for water facilities and/or fire protection system to Central
Arkansas Water for review.
February 9, 2023
ITEM NO.: A (Cont.) FILE NO.: Z-5502-J
5
3. Plan revisions may be required after additional review.
4. Contact Central Arkansas Water regarding procedures for installation of water
facilities and/or fire service.
5. Approval of plans by the Arkansas Department of Health Engineering Division
and Little Rock Fire Department is required.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1.
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building
or facilities exceeding 30 feet or three stories in height shall have at least two
means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provide with two separate and approved fire apparatus access roads.
February 9, 2023
ITEM NO.: A (Cont.) FILE NO.: Z-5502-J
6
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead
Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be
provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access
road gates. Gates securing the fire apparatus access roads shall comply with
all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one
person.
4. Gate components shall be maintained in an operable condition at all times
and replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices
shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock
unless they are capable of being opened by means of forcible entry tools or
when a key box containing the keys to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code
official.
8. Electric gate operators, where provided, shall be listed in accordance with
UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
Exception: Projects having a gross building area of up to 124,000 square
feet that have a single approved fire apparatus access road when all
building are equipped throughout with approved automatic sprinkler
systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of the
February 9, 2023
ITEM NO.: A (Cont.) FILE NO.: Z-5502-J
7
maximum overall diagonal dimension of the lot or area to be served, measured in
a straight line between accesses.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal’s Office
(Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram
501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comments received.
County Planning:
1. Obtain Driveway permit form Pulaski County Public Works for new driveway off
Kanis Road.
2. Provide AHD septic permit for wastewater system.
3. Obtain West Pulaski Volunteer Fire Department Approval.
4. Provide CAW approval for water service.
5. Submit a copy of the SWPPP for this project.
6. Obtain flood permit for buildings/fill inside the 100 year floodplain.
7. Verify development does not violate any existing covenants/restrictions listed in the
Independence Farms Subdivision Bill of Assurance.
8. Show State Plane Coordinates for two section or quarter section corners.
9. Verify Flood panel information Zone shows to be AE Zone not AH.
10. Show certificates of owner, surveying accuracy and engineering accuracy.
11. Include owner's name and address on certificate.
12. Any city required half street improvements to Kanis Road will need to be reviewed
and approved by the County Public Works Department prior to construction.
13. Show property owners for abutting property.
14. Show existing property zoning.
15. Provide storm drainage plan.
16. Pay $33.00 review fee.
F. BUILDING CODES/LANDSCAPE:
Building Code: No comments received.
February 9, 2023
ITEM NO.: A (Cont.) FILE NO.: Z-5502-J
8
Landscape:
1. Any new site development must comply with the City’s minimal landscape and
buffer ordinance requirements.
2. A land use buffer six (6) percent of the average width / depth of the lot will be
required when an adjacent property has a dissimilar use of a more restrictive
nature. The properties to the south, east, and west are zoned R-2. As a
component of all land use buffer requirements, opaque screening, whether a
fence or other device, a minimum of six (6) feet in height shall be required upon
the property line side of the buffer. A minimum of seventy (70) percent of the
land use buffer shall be undisturbed. In addition to the required screening,
buffers are to be landscaped at the rate of one (1) tree and three (3) shrubs for
every thirty (30) linear feet. Easements cannot count toward fulfilling this
requirement. The plantings, existing and purposed, shall be provided within
the landscape ordinance of the city, section 15-81.
More than 70% of the of the existing south and west buffers are showing
to be disturbed.
3. Street buffers will be required at six (6) percent of the average depth of the lot.
The minimum dimension shall be one-half (½) the full width requirement but in
no case be less than nine (9) feet.
4. An automatic irrigation system to water landscaped areas shall be required for
developments of one (1) acre or larger.
5. The development of two (2) acres or more requires the landscape plan to be
stamped with the seal of a Registered Landscape Architect.
6. The City Beautiful Commission recommends preserving as many existing trees
as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper
or larger.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
The request is in the Ellis Mountain Planning District. The Land Use Plan shows
Suburban Office (SO) and Park/Open Space (PK/OS) for the requested area. The
Suburban Office (SO) category shall provide for low intensity development of office
or office parks in close proximity to lower density residential areas to assure
compatibility. A Planned Zoning District is required. The Park/Open Space
February 9, 2023
ITEM NO.: A (Cont.) FILE NO.: Z-5502-J
9
(PK/OS) category includes all public parks, recreation facilities, greenbelts, flood
plains, and other designated open space and recreational land. The request is to
amend and expand an existing Planned Commercial Development (PCD) District
(self-storage) to allow expansion into an area zoned R-2, Single Family District.
Surrounding the application area, the Land Use Plan shows Suburban Office (SO)
to the west. Mixed Office Commercial (MOC) is shown on the Plan map to the
east. Across Kanis Road to the north the Plan map shows Commercial (C) then
Park/Open Space (PK/OS) then Office (O) use (from east to west). To the south
is Residential Low Density (RL). The Suburban Office (SO) category shall provide
for low intensity development of office or office parks in close proximity to lower
density residential areas to assure compatibility. A Planned Zoning District is
required. Immediately to the west is land zoned R-2, Single Family with houses
then C-3. Then beyond that is General Commercial District land with an auto repair
business, house, and vacant land. The Mixed Office Commercial (MOC) category
provides for a mixture of office and commercial uses to occur. Acceptable uses are
office or mixed office and commercial. A Planned Zoning District is required if the
use is mixed office and commercial. Beyond the R-2 zoned land owned by
Entergy (transmission line), is land zoned Planned Commercial Development
(PCD) District with a Costco. The Commercial (C) category provides for a broad
range of retail and wholesale sales of products, personal and professional
services, and general business activities. Commercial activities vary in type and
scale, depending on the trade area that they serve. The land across Kanis Road
is zoned O-2, Office and Institutional District, and Planned Office Development
(POD) District. There are some houses that have been converted into businesses,
such as a pet care facility and a halfway house. The Residential Low Density (RL)
category provides for single family homes at densities not to exceed 6 dwelling
units per acre. Such residential development is typically characterized by
conventional single family homes but may also include patio or garden homes and
cluster homes, provided that the density remain less than 6 units per acre. The
land to the south is large-tract single-family houses zoned R-2, Single Family
District.
Master Street Plan: To the north is Kanis Road, It is shown as a Minor Arterial on
the Master Street Plan. A Minor Arterial provides connections to and through an
urban area and their primary function is to provide short distance travel within the
urbanized area. Entrances and exits should be limited to minimize negative effects
of traffic and pedestrians on Kanis Road since it is a Minor Arterial. This street
may require dedication of right-of-way and may require street improvements for
entrances and exits to the site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
February 9, 2023
ITEM NO.: A (Cont.) FILE NO.: Z-5502-J
10
Historic Preservation Plan: There are no existing historic sites on, or in proximity
to, this land.
H. ANNALYSIS:
The applicant proposes to revise the PD-C for the property located at 17301 Kanis
Road to allow the development of an additional 8.26 acres to the west to include
seven (7) additional mini-warehouse buildings and additions to two (2) of the
previously approved mini-warehouse buildings.
The site is vacant and cleared of structures and trees. A single driveway along the
northeast edge of the property provides access from Kanis Road. A centrally
located pond covers a good portion of the eastern section of the site from north to
south and drains into a creek running southeast serving as a tributary to Rock
Creek. The creek runs North to south parallel to the pond dividing the western
portion of the site. Properties to the north and east of the development includes
commercial, and office use zoned uses and properties to the south and west
include residential uses. The property to the north directly across Kanis Road
owned by Entergy, zoned R-2 and O-2 and includes electrical transmission lines
traversing in a north/south direction.
The applicant proposes to extend the eastern portion of the proposed development
west to 25 feet of the border the Rock Creek floodway to include approximately
0.28 acres for two (2) additional mini-warehouse structures and additions to two
(2) of the previously approved structures. with a fenced enclosure. The site plan
shows the development extending west across the Rock Creek floodway to include
an additional 8.26 acres to include five (5) mini-warehouse structures and an
access drive connecting to Kanis Road to the north.
The site plan shows that the applicant proposes that the creek will be rerouted to
drain into the floodway. Stormwater detention ponds are shown to be located in
the southeast and southwest edges of the property to collect additional run-off from
the site. All development is proposed to the located at least 25 feet from the edge
of the existing floodway area.
The applicant proposes that the overall development will contain eighteen (18)
mini-warehouse storage structures and an office structure with an on-site
manager’s residence. The site plan shows a fenced enclosure around the eastern
portion of the development extending south from a twenty-four (24) hour access
gate around the structures and bordering the Rock Creek floodway.
The applicant notes there are five (5) parking spaces. Section 36-502(3)(c) of the
City’s Zoning Ordinance would typically require three (3) parking spaces for office
use. Staff believes the parking is sufficient to serve the proposed building.
February 9, 2023
ITEM NO.: A (Cont.) FILE NO.: Z-5502-J
11
Applicant notes trash collection will be accomplished with a residential style
container for the office/apartment.
There will be no dumpster located at the site. Any new dumpsters must be
screened as per Section 36-523 (d) of the City’s Zoning Ordinance.
Applicant notes all sight lighting will be low-level and directed away from adjacent
properties.
A monument sign is proposed along West Kanis Road near the office and on the
outside wall of the office/apartment. All signs in commercial zones must conform
to Section 36-555 of the City’s Zoning Ordinance.
The applicant provided responses and additional information to all issues raised
during staff’s review of the application. To staff’s knowledge there are no
outstanding issues.
Staff is not supportive of the requested revised (PD-C) Planned Development –
Commercial zoning. Staff does not view the request as reasonable. Although
there are other mini-warehouse related uses in this immediate area, staff feels that
the applicant’s proposed expansion of this development will proliferate this type of
use and have an adverse impact on the area.
The proposed development is similar other commercial properties located within
the relatively small commercial area along the Kanis Road corridor between the
Chenal Parkway intersection (east) and the Rahling Road intersection (west), two
(2) of these properties currently have existing mini-warehouse type uses, with
additional properties containing mini-warehouse type developments to the north
and south of Chenal Parkway. Staff believes that there are enough self-storage
uses within this small commercial area. The proposed use will only add to the
proliferation of existing mini warehouse uses. Staff believes that the previously
approved PD-C for the property will better serve the small area of use.
I. STAFF RECOMMENDATION:
Staff recommends denial of the requested revised PD-C zoning.
PLANNING COMMISSION ACTION: (FEBRUARY 9, 2023)
Staff informed the Commission that the applicant requested the application be withdrawn,
without prejudice. Staff supported the withdrawal request. The item was placed on the
Consent Agenda for withdrawal, without prejudice. The vote was 10 ayes, 0 nays and
1 absent. The application was withdrawn, without prejudice.
February 9, 2023
ITEM NO.: B FILE NO.: Z-9739
NAME: Love Family Care Facility – Special Use Permit
LOCATION: 5918 Drexel Avenue
DEVELOPER:
Veronica Love
5918 Drexel Avenue
Little Rock, AR 72209
OWNER/AUTHORIZED AGENT:
Veronica Love – Owner
AREA: 0.28 acre NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF
WARD: 2 PLANNING DISTRICT: 14 CENSUS TRACT: 41.08
CURRENT ZONING: R-2
VARIANCE/WAIVERS: None requested.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
A Special Use Permit is requested to allow a home healthcare facility to be
operated in a single-family residence located at an R-2 zoned property.
B. EXISTING CONDITIONS:
The property contains a 1,416 square foot, one-story brick structure at the corner
of Drexel Avenue and Geyer Springs Road. The residence has a rear yard which
is fenced, and a drainage easement running along the backside of the property.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 200 feet of the site and all neighborhood
associations registered with the City of Little Rock were notified of the public hearing.
February 9, 2023
ITEM NO.: B (Cont.) FILE NO.: Z-9739
2
D. ENGINEERING COMMENTS: No comments.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments received.
Entergy: No comments received.
Summit Utility: No comments.
AT & T: No comments received.
Central Arkansas Water:
No Objections. All Central Arkansas Water requirements in effect at the time of
request for water service must be met.
Fire Department: No comments.
Parks and Recreation: No comments received.
County Planning: No comments.
F. BUILDING CODES/LANDSCAPE:
Building Code: No comments received.
Landscape: No comments.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division: No comments.
H. ANALYSIS:
The applicant is requesting a Special Use Permit to allow a home healthcare facility
to be operated in a single-family residence located at an R-2 zoned property
located at 5918 Drexel Avenue.
The property contains a 1,416 square foot, one-story brick structure at the corner
of Drexel Avenue and Geyer Springs Road. The residence has a rear yard which
is fenced, and a drainage easement running along the backside of the property.
February 9, 2023
ITEM NO.: B (Cont.) FILE NO.: Z-9739
3
The proposed home healthcare facility will have a maximum of six (6) clients at
any given time. The applicant proposes to have a caregiver onsite 24 hours per
day, 7 days per week. The level of care needed per each resident will determine
how many schedules (units) or hours of care will take place at the residence. There
will also be an administrator and or registered nurse on call. Their staffing will be
administered by Home Health Care of Arkansas, who has over 35 caregivers
employed in the area. According to the applicant, there will always be a caregiver
onsite. Some employees will be responsible for cleaning, cooking, and laundry
duties, while other will be assigned to do direct personal care for the clients.
The residence has three bedrooms and two full bathrooms for use by the clients.
The applicant states that each room will house two people and is spacious enough
for two twin beds and all their belongings.
Including the garage, there are six available parking spaces. Additionally, the
applicant states the rear yard could be paved and used for parking if needed.
No signage beyond that allowed in single family zones will be permitted.
Section 36-3 of the City’s Zoning Ordinance defines a Family Care Facility as a
facility which provides resident services in a family-like environment to six (6) or
fewer individuals and not more than two (2) staff personnel. These individuals
require a minimal level of supervision and are provided service and supervision in
accordance with their individual needs. According to Section 36-54(e)(2), the site
and location criteria for Family Care Facility are as follows:
a. This use may be located only in a single-family dwelling.
b. Medical or counseling needs must be provided off-site.
c. No physical changes in the residence are permitted which would provide other
than sleeping accommodations.
d. Drives and parking shall not exceed that required by ordinance for a single-
family residence.
e. The number and spacing of existing similar facilities in the neighborhood.
f. Existing zoning and land use patterns.
g. Area-wide availability of facilities providing like services.
h. Provision for readily accessible public or quasi-public transportation.
i. The fire marshal must approve use of the residence for the proposed family
care facility.
February 9, 2023
ITEM NO.: B (Cont.) FILE NO.: Z-9739
4
Section 36-54 (e)(4) a. states the following:
Separation, spacing and procedural requirements for family care facilities, group
care facilities, group homes, parolee or probationer housing facilities and
rooming, lodging and boarding facilities will be determined by the planning
commission so as not to adversely impact the surrounding properties and
neighborhood. Unless the commission determines that a different area is more
appropriate, a neighborhood shall be defined as an area incorporating all
properties lying within one thousand five hundred (1,500) feet of the site for which
the permit is requested.
Staff feels that the proposed family care facility is too intense for the residential
setting and will have an adverse impact on the general area.
To staff’s knowledge, there are no similar types of family care facilities / living
facilities within 1,500 feet of the subject property.
I. STAFF RECOMMENDATION:
Staff recommends denial of the Special Use Permit to allow a family care family
home at 5918 Drexel Avenue.
PLANNING COMMISSION ACTION: (DECEMBER 8, 2022)
The applicant was not present. There were no persons present registered in
opposition. Staff informed the Commission that the applicant failed to send the
required notices to surrounding property owners as required. Therefore, staff
recommended the application be deferred to the January 12, 2023 agenda. There
was no further discussion. The item remained on the consent agenda and was
deferred as recommended by staff. The vote was 7 ayes, 0 nays, 3 absent and
1 open position.
PLANNING COMMISSION ACTION: (JANUARY 12, 2023)
The applicant was not present. There were no persons present registered in
opposition. Staff informed the Commission that the applicant failed to send the
required notices to surrounding property owners as required. Therefore, staff
recommended the application be deferred to the February 9, 2023 agenda. There
was no further discussion. The item remained on the consent agenda and was
deferred as recommended by staff. The vote was 10 ayes, 0 nays, 0 absent and
1 open position.
February 9, 2023
ITEM NO.: B (Cont.) FILE NO.: Z-9739
5
PLANNING COMMISSION ACTION: (FEBRUARY 9, 2023)
Staff informed the Commission that the applicant requested the application be withdrawn.
Staff supported the withdrawal request. The item was placed on the Consent Agenda for
withdrawal. The vote was 10 ayes, 0 nays and 1 absent. The application was withdrawn.
February 9, 2023
ITEM NO.: C FILE NO.: Z-9747
NAME: York Accessory Dwelling – Conditional Use Permit
LOCATION: 319 Valmar Street
DEVELOPER:
Erica York (Owner)
319 Valmar Street
Little Rock, AR 72205
OWNER/AUTHORIZED AGENT:
Erica York (Owner)
319 Valmar Street
Little Rock, AR 72205
AREA: 0.13 acre NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF
WARD: 3 PLANNING DISTRICT: 9 CENSUS TRACT: 48
CURRENT ZONING: R-3
VARIANCE/WAIVERS:
1. Variance to allow the accessory dwelling to exceed the maximum thirty (30) percent
rear yard coverage.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant is requesting a conditional use permit to allow an accessory dwelling
on the R-3 zoned property located at 319 Valmar Street.
B. EXISTING CONDITIONS:
The property is occupied by a one-story brick and frame residence. The
residence is approximately 1,336 square feet in area. A driveway provides
access from Valmar Street and extends the length of the residence along the
north property line. A one-story frame garage structure was recently removed
from the rear yard area.
February 9, 2023
ITEM NO.: C (Cont.) FILE NO.: Z-9747
2
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 200 feet of the site and all neighborhood
associations registered with the City of Little Rock were notified of the public hearing.
D. ENGINEERING COMMENTS: No comments.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority:
1. We have a sewer line in the rear of the property and no easement is shown.
Entergy: No comments received.
Summit Utility: No comments.
AT & T: No comments received.
Central Arkansas Water: No Objections.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal’s Office
(Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram
501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comments received.
County Planning: No comments received.
F. BUILDING CODES/LANDSCAPE:
Building Code: No comments received.
February 9, 2023
ITEM NO.: C (Cont.) FILE NO.: Z-9747
3
Landscape: No comments.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division: No comments.
H. ANALYSIS:
The applicant is requesting a conditional use permit to allow an accessory dwelling
on the R-3 zoned property located at 319 Valmar Street. The property is occupied
by a one-story brick and frame residence. The residence is approximately
1,336 square feet in area. A driveway provides access from Valmar Street and
extends the length of the residence along the north property line. A one-story
frame garage and shed structure no longer exists in the rear yard area. The
applicant notes the principal structure will be leased for a minimum of one (1) year,
most likely to a UAMS hospital resident/fellow in town for training. The property
owner will occupy the accessory dwelling as their main residence.
The applicant proposes to construct a two-story accessory dwelling in the within the
rear yard area. The accessory dwelling will be 26.33 feet by 28.33 feet (746 square
feet) in area with a 2-car garage on the lower level. The dwelling will also contain
two (2) bedrooms and one (1) bath on the second level. The proposed accessory
dwelling structure will be located from 6.00 feet to 7.12 feet from the side (north)
property line, 11 feet from the rear (east) property line and range from 8.14 feet to
9.20 feet from the south property line. The site plan indicates the accessory dwelling
will be 30.55 feet from the principal structure which provides ample maneuvering
room between the principal dwelling and the accessory dwelling utilizing the access
drive from Valmar Street.
The applicant is requesting one (1) variance with the proposed conditional use
permit. Section 36-156(2)(c) of the City’s Zoning Ordinance requires that accessory
dwellings in the R-1 through R4-A districts not occupy more than thirty (30) percent
of the required rear yard area (rear 25 feet of the lot). The proposed accessory
building will occupy thirty-five (35) percent of the required rear yard. Staff considers
this variance to be minor in nature. Staff supports the variance request.
Staff is supportive of the requested conditional use permit and minor variance
request to allow construction of an accessory dwelling on the site. Staff views the
request as reasonable. The general area contains a mixture of residential types
and zoning, including rental properties. R-4 and PRD zoned properties are located
in the general neighborhood area, which contain multi-unit rental properties. The
February 9, 2023
ITEM NO.: C (Cont.) FILE NO.: Z-9747
4
proposed accessory dwelling will not be out of character with the surrounding
properties and should have no adverse impact on the neighborhood.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested Conditional Use Permit subject
to the comments and conditions noted in paragraph E, and the staff analysis,
of the agenda staff report.
PLANNING COMMISSION ACTION: (JANUARY 12, 2023)
The applicant was present. There were no persons present registered in opposition in
attendance. Staff informed the Commission that the applicant submitted a letter to staff
on December 29, 2022, requesting this application be deferred to the February 9, 2023
Planning Commission Agenda. Staff supported the deferral request. There was no
further discussion. The item remained on the consent agenda and was deferred as
recommended by staff. The vote was 10 ayes, 0 nays, 0 absent and 1 open position.
PLANNING COMMISSION ACTION: (FEBRUARY 9, 2023)
The applicant was present. There were no persons present registered in opposition. Staff
presented the item and a recommendation of approval as outlined in the “staff
recommendation” above. There was no further discussion. The item remained on the
consent agenda for approval as recommended by staff, including all staff comments and
conditions. The vote was 10 ayes, 0 nays and 1 absent.
February 9, 2023
ITEM NO.: D FILE NO.: Z-9746
NAME: Rivera Event Center – Conditional Use Permit
LOCATION: 7521 Geyer Springs Road
DEVELOPER:
Jesus Rivera
7521 Geyer Springs Road
Little Rock, AR 72209
(501) 859-5264
OWNER/AUTHORIZED AGENT:
Jesus Rivera
7521 Geyer Springs Road
Little Rock, AR 72209
(501) 859-5264
SURVEYOR/ENGINEER:
Joe White / Joe White and Associates
25 Rahling Circle, Suite A-2
Little Rock, AR 72203
(501) 214-9141
AREA: 1.19 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF
WARD: 2 PLANNING DISTRICT: 13 CENSUS TRACT: 20.02
CURRENT ZONING: C-3
VARIANCE/WAIVERS: No variances requested.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant is requesting a Conditional Use Permit to allow the use of an existing
single-story C-3 zoned commercial building for an event center.
February 9, 2023
ITEM NO.: D (Cont.) FILE NO.: Z-9746
2
B. EXISTING CONDITIONS:
The property is currently developed containing a 7,850 square foot commercial
building, paved parking lot for up to (91) vehicles, and two (2) access drives
connecting to Geyer Springs Road along the west perimeter of the property.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 200 feet of the site and all neighborhood
associations registered with the City of Little Rock were notified of the public
hearing.
D. ENGINEERING COMMENTS:
Existing building and site shall comply with accessibility requirements per AR Fire
Prevention Code 3411.4.2 which includes: one accessible building entrance, one
accessible route from the accessible building entrance to the accessible parking
aisles and stalls and providing required number of accessible parking stalls and
aisles. These requirements are to be provided to the maximum extent technically
feasible on site.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments.
Entergy: No comments received.
Summit Energy: No comments received.
AT & T: No comments received.
Central Arkansas Water: NO OBJECTIONS; All Central Arkansas Water
requirements in effect at the time of request for water service must be met.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
February 9, 2023
ITEM NO.: D (Cont.) FILE NO.: Z-9746
3
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal’s Office
(Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram 501-918-
3756 Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comments received.
County Planning: No comments received.
F. BUILDING CODES/LANDSCAPE:
Building Code: No comments received.
Landscape: No Comments.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division: No comments.
H. ANALYSIS:
The applicant is requesting a Conditional Use Permit to allow the use of an existing
single-story C-3 zoned commercial building for an event center.
February 9, 2023
ITEM NO.: D (Cont.) FILE NO.: Z-9746
4
The property is currently developed containing a 7,850 square foot commercial
building, paved parking lot for up to (91) vehicles, and two (2) access drives connecting
to Geyer Springs Road along the west perimeter of the property.
The site plan shows an existing parking configuration including ninety-one (91)
spaces which exceeds the required minimum. Staff believes the current number
of parking spaces will be sufficient to serve the proposed uses.
The applicant proposes to host events such as wedding receptions, baptisms,
birthday parties, Quincereas, and graduation parties with hours of operation
between 12:00 p.m. and 12:00 a.m. Fridays through Sundays. The applicant
notes that the building is currently finished out with an estimated maximum
occupancy of 500 which will be regulated by the fire code and that “booking
operations” will be held in the space Monday through Thursday.
The applicant notes that the renter (host) of the event will be responsible for service
of food or beverages served at the events and that no alcoholic beverages or food
service will be provided at the events by the owner of the building.
The proposed site plan shows a proposed screened dumpster located at the
southeast corner of the developed lot. The dumpster must be screened as per
Section 36-523 of the City’s Zoning Ordinance.
All new site lighting is low level and directed away from adjacent properties per
ordinance requirements.
The site plan shows existing signage between the existing Geyer Springs Road
access drives. All new signage on the property must comply with Section 36-555
of the zoning ordinance (signs permitted in Commercial zones).
The applicant provided responses and additional information to all issues raised
during staff’s review of the application. The applicant requested no variances
with the proposed Conditional Use Permit.
Staff is supportive of the requested Conditional Use Permit to allow the
development of an event venue in the existing commercial building. Staff views
the request as reasonable. The property is in an area surrounded by similar uses
and zoning, with similar commercial developments adjacent to the property to the
north, west, and south long Geyer Springs Road. Staff believes the proposed use
will have no adverse impact on the surrounding properties.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested Conditional Use Permit to allow the
proposed event center use, subject to compliance with the comments and
February 9, 2023
ITEM NO.: D (Cont.) FILE NO.: Z-9746
5
conditions outlined in paragraph E, and the staff analysis, of the agenda staff
report.
PLANNING COMMISSION ACTION: (JANUARY 12, 2023)
The applicant was not present. There were no persons present registered in
opposition. Staff informed the Commission that the applicant failed to send the
required notices to surrounding property owners as required. Therefore, staff
recommended the application be deferred to the February 9, 2023 agenda. There
was no further discussion. The item remained on the consent agenda and was
deferred as recommended by staff. The vote was 10 ayes, 0 nays, 0 absent and
1 open position.
PLANNING COMMISSION ACTION: (FEBRUARY 9, 2023)
The applicant was present. There were no persons present registered in opposition. Staff
presented the item and a recommendation of approval as outlined in the “staff
recommendation” above. There was no further discussion. The item remained on the
consent agenda for approval as recommended by staff, including all staff comments and
conditions. The vote was 10 ayes, 0 nays and 1 absent.
February 9, 2023
ITEM NO.: E FILE NO.: Z-9535-A
NAME: Ranch Creek Townhomes – PD-R
LOCATION: West side of Tulley Cove, North of 16100 Cantrell Road
DEVELOPER:
Newcap Land Holdings, LLC
PO Box 241667
Little Rock, AR 72223
OWNER / AUTHORIZED AGENT:
TLC, LLC – Owner
Joe White & Associates – Agent
SURVEYOR / ENGINEER:
Joe White & Associates
25 Rahling Circle, Suite A-2
Little Rock, AR 72223
AREA: 1.9 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF
WARD: 4 PLANNING DISTRICT: 1 CENSUS TRACT: 42.05
CURRENT ZONING: R-2
VARIANCE / WAIVERS: None requested.
A. PROPOSAL / REQUEST / APPLICANT’S STATEMENT:
The applicant proposes to rezone 1.9 acres from “R-2” Single Family District to
Planned Development – Residential (PD-R) to allow the construction of three (3)
multi-family buildings, with fifteen (15) units in the development.
B. EXISTING CONDITIONS:
The site is currently undeveloped and wooded. The property contains varying
degrees of slope.
February 9, 2023
ITEM NO.: E (Cont.) FILE NO.: Z-9535-A
2
C. NEIGHBORHOOD COMMENTS:
All owners of property located within 200 feet of the site and all neighborhood
associations registered with the City of Little Rock were notified of the public
hearing.
D. ENGINEERING COMMENTS:
1. Provide finished floor elevations (FFE) for all buildings on plat, site plan, and
grading and drainage plans at least one foot above base flood elevation or
more per flood insurance study and FEMA FIRM panel.
2. A Special Flood Hazard Development Permit is required to be obtained to
prior to beginning construction. The Special Flood Hazard Development
Permit application can be found at https://www.littlerock.gov/city-
administration/city-departments/public-works/. Special Flood Hazard
Development Permits are issued by the Public Works Department at
701 West Markham Street and no fee collected for issuance. Contact Vince
Floriani in Public Works at 501-371-4823 or VFloriani@littlerock.gov to
schedule an appointment for issuance or to answer any questions.
3. Due to the proposed structure being located within the 100 year floodplain,
an elevation certificate of the finished floor elevation must be provided to the
Public Works Department at 701 West Markham Street prior to the issuance
of a certificate of occupancy. Contact Vince Floriani in Public Works at
501-371-4823 or VFloriani@littlerock.gov to schedule an appointment for
issuance or to answer any questions.
4. Per City Code, 13-57, variances for development in the regulatory floodway
are prohibited unless (1) All requirements of 44 CFR 65.12 are first met or (2)
(a) A no rise certificate signed and sealed by a professional engineer licensed
to practice in the State of Arkansas is submitted to document that no increase
in base flood elevation would result from granting a variance for the proposed
development (b) protective measures are employed to minimize damages
during flooding events and (c) the variance does not result in adverse impact
to other lands.
5. In accordance with Section 31-176, floodway areas must be shown as
floodway easements or be dedicated to the public. In addition, a 25-foot-wide
drainage and access easement is required adjacent to the floodway
boundary.
6. Alteration of the water course will require approval from the Little Rock District
of the US Army Corps of Engineers prior to start of work.
7. The proposed alteration of the floodway will require flood map revisions.
Obtain a conditional letter of map revision and no rise certification approval
from Little Rock Public Works Department’s floodplain administrator and the
February 9, 2023
ITEM NO.: E (Cont.) FILE NO.: Z-9535-A
3
Federal Emergency Management Agency prior to issuance of a grading
permit and/or a building permit. An approved letter of map revision must be
obtained prior to issuance of a certificate of occupancy.
8. Per City Code 29-186 (c), a grading permit is required for land alteration on
properties within the designated floodplain without exception. Grading
permits are issued by the Planning and Development Dept. at 723 West
Markham Street after approval of sediment and erosion control plans, grading
and drainage plans, land survey, drainage study, and soil loss calculations
per City’s stormwater management and drainage manual. Contact Planning
and Development Dept., Engineering Division at 501-371-4817 or at
501-918-5348 or Permits@littlerock.gov to schedule an appointment for
issuance or to answer any questions. Permit cost is based on total project
area at $100.00 for the less than ½ acre, $200.00 for ½ to 1 acre, and $200.00
for the first acre and $100.00 for each additional acre for project greater than
1 acre. Any work involving one (1) or more acres of disturbed area requires
a State of Arkansas NPDES permit. Contact the Arkansas Department of
Environmental Quality, NPDES branch at 501-682-0744 for applications and
information about General Stormwater Discharge Construction Permit
#ARR150000.
9. Damage to public and private property due to hauling operations or
operations of construction related equipment from a construction site shall be
repaired by the responsible party prior to the issuance of a certificate of
occupancy.
10. A maintenance bond for 50% of total construction costs for all completed
public street and drainage improvements within City right of way and as-built
storm drainage infrastructure plans shall be provided to the Department of
Planning and Development before the issuance of a final certificate of
occupancy.
11. A drainage study showing all hydrologic and hydraulic calculations for the
proposed storm sewer pipe system, detention ponds and structures, and
inlets is required. For final drainage report, sign, date, and seal the report per
AR State Board of Professional Engineers and Professional Surveyors rules
Article 12, Section B (1) (a). Provide engineer's certification statement saying
this drainage report was conducted by yourself or directly under your
supervision and attesting to the accuracy of the information within this report.
12. Per City Rev. Code 29-99, stormwater detention for developments is
required. Provide stormwater detention infrastructure to satisfy this
requirement.
13. The Department requires three (3) phase sediment and erosion control (SEC)
plans to be submitted for all construction projects showing best management
practices (BMPs) for mitigating sediment runoff and erosion along with
vegetation specifications for temporary and permanent soil stabilization.
February 9, 2023
ITEM NO.: E (Cont.) FILE NO.: Z-9535-A
4
Phase 1 SEC plans shall show SEC BMPs during the stripping, clearing,
grubbing, and rough grading of the site. Phase 2 SEC plans shall show SEC
BMPs during construction of utilities, buildings, roadway infrastructure and
drainage infrastructure. Phase 3 SEC Plans shall show SEC BMPs for final
grading, seeding, and landscaping of the site.
14. Sediment and Erosion Control plans shall also show the pertinent information
as outlined in ADEQ ARR150000 Permit Part II section A-4-H (1-14) and Part
II section A-4-I-2 (A-B).
E. UTILITIES / FIRE DEPARMENT / PARKS / COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments.
Entergy: No comments received.
Summit Energy: No comments.
AT&T: No comments received.
Central Arkansas Water:
All Central Arkansas Water requirements in effect at the time of request for water
service must be met. Please submit plans for water facilities to Central Arkansas
Water for review. Plan revisions may be required after additional review. Contact
Central Arkansas Water regarding procedures for installation of water facilities.
Approval of plans by Central Arkansas Water, the Arkansas Department of Health
Engineering Division and Little Rock Fire Department is required.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
February 9, 2023
ITEM NO.: E (Cont.) FILE NO.: Z-9535-A
5
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
30’ Tall Buildings - Maintain aerial fire apparatus access roads as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1
– D105.4
D105.1 Where Required. Where the vertical distance between the grade
plane and the highest roof surface exceed 30’, approved aerial fire apparatus
access roads shall be provided. For the purposes of this section the highest roof
surfaces shall be determined by measurement to the eave of a pitched roof, the
intersection of a roof to the exterior wall, or the top of the parapet walls, whichever
is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26’, exclusive of shoulders, in the immediate vicinity of the
building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes
meeting this condition shall be located within a minimum of 15 feet and a maximum
of 30 feet from the building, and shall be positioned parallel to one entire side of
the building. The side of the building on which the aerial fire apparatus access
road is positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located
over the aerial fire apparatus access road or between the aerial fire apparatus road
and the building. Other obstructions shall be permitted to be places with the
approval of the fire code official.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead
Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be
provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
February 9, 2023
ITEM NO.: E (Cont.) FILE NO.: Z-9535-A
6
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access
road gates. Gates securing the fire apparatus access roads shall comply with
all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one
person.
4. Gate components shall be maintained in an operable condition at all times
and replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices
shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock
unless they are capable of being opened by means of forcible entry tools or
when a key box containing the keys to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code
official
8. Electric gate operators, where provided, shall be listed in accordance with
UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
Multi-Family Residential Developments
As per Appendix D, Section D106.1 of the 2012 Arkansas Fire Prevention
Code Vol. 1. Projects having more than 100 dwelling units. Multiple-family
residential projects having more than 100 dwelling units shall be equipped
throughout with two separate and approved fire apparatus access roads.
Exception: Projects having up to 200 dwelling units may have a single
approved fire apparatus access road when all building, including nonresidential
occupancies are equipped throughout with approved automatic sprinkler systems
installed in accordance with Section 903.3.1.1 or 903.3.1.2
As per Appendix D, Section D106.2 of the 2012 Arkansas Fire prevention
Code Vol. 1. Projects having more than 200 dwelling units. Multiple-family
residential projects having more than 200 dwelling units shall be provided with two
February 9, 2023
ITEM NO.: E (Cont.) FILE NO.: Z-9535-A
7
separate and approved fire apparatus access roads regardless of whether they
are equipped with an approved automatic sprinkler system.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal’s Office
(Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram
501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1.
F. BUILDING CODES / LANDSCAPE:
Building Code: No comments received.
Landscape:
1. Any new site development must comply with the City’s minimal landscape and
buffer ordinance requirements.
2. The City Beautiful Commission recommends preserving as many existing trees
as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper
or larger.
G. TRANSPORTATION / PLANNING:
Rock Region Metro: No comments received.
Planning Division:
The request is in the River Mountain Planning District.
The Land Use Plan shows Residential Low Density (RL) for the requested area.
The Residential Low-Density category provides for single family homes at
densities not to exceed 6 dwelling units per acre. Such residential development is
typically characterized by conventional single-family homes but may also include
patio or garden homes and cluster homes, provided that the density remains less
than 6 units per acre. The application is to rezone from Single Family District
(R-2) to Planned Development - Residential (PD-R) for the development of
townhomes. This site is in the Highway 10 Design Overlay District.
Surrounding the application area, the Land Use Plan shows RL to the north and
east. North is the developed single-family Terra Bella subdivision, to the east is
the developed single-family Thomas Park subdivision, both zoned R-2. To the
south of the application area is Taylor Loop Creek shown as Park/Open Space on
February 9, 2023
ITEM NO.: E (Cont.) FILE NO.: Z-9535-A
8
the Plan Map. South of Taylor Loop Creek, the Land Use Plan shows Transition
(T). Transition is a land use plan designation that provides for an orderly transition
between residential uses and other more intense uses. The Park Open Space
category includes all public parks, recreation facilities, greenbelts, flood plains, and
other designated open space and recreational land. This land is the floodway of
Taylor Loop Creek. Transition was established to deal with areas which contain
zoned residential uses and nonconforming nonresidential uses. A Planned Zoning
District is required unless the application conforms to the Design Overlay
standards. Uses that may be considered are low-density multi-family residential
and office uses if the proposals are compatible with quality of life in nearby
residential areas. Southeast are two offices developed as Planned Development-
Office (PD-O), for single office use or building.
Master Street Plan:
To the south is Cantrell Road and is shown as a Principal Arterial on the Master
Street Plan. Principal Arterial roads are designed to serve through traffic and to
connect major traffic generators or activity centers within urbanized areas. Since
these roads are designed for through traffic and are generally located three or
more miles apart, dedication of additional right-of-way is required to allow for future
expansion to six through lanes plus left and right turn lanes. Right-of-way of 110
feet is required but may vary due to topography, floodway or other constraints
eliminating or reducing future adjacent development. Sidewalks are required on
both sides. This street may require dedication of right-of-way and may require
street improvements for entrances and exits to the site.
Bicycle Plan: Cantrell Road is shown as a Class I Bike Path. Class I Bike Paths
are designated for the sole use of bicycles that is physically separated from
vehicular lanes.
Historic Preservation Plan: There are no existing historic sites on, or in proximity
to, this land.
H. ANALYSIS:
The applicant proposes to rezone the 1.9 acre property located at the west side
of Tulley Cove, north of 16100 Cantrell Road from "R-2" Single Family District
to "PD-R" Planned Development - Residential District. The property is part of
the Taylor Loop Creek Addition (Lot 2 – unrecorded), which is currently
undeveloped and wooded. Most of the property resides in the 100-year floodplain,
with the floodway running along the south end of the development.
The applicant proposes to construct three (3) three-story structures on the property
with a total of 15 single family residential units available for use. One of the
buildings will house five (5) of the units, while the other two will have four (4) and
February 9, 2023
ITEM NO.: E (Cont.) FILE NO.: Z-9535-A
9
six (6) units, respectively. Each of the units will be individually owned, and the
trash service for the property will be handled by waste and recycling containers at
each unit.
A development of this type calls for twenty-two (22) parking spaces; Ranch Creek
Townhomes will have thirty-seven (37) parking spaces, with thirty (30) spaces
shown in the fifteen (15) garages at each unit. Seven (7) spaces at the site will be
reserved for guests (two of these will be handicap spaces).
The proposed buildings will have a minimum front setback, per Highway 10 overlay
standards, at one hundred (100) feet. The rear setback, also per Highway 10
overlay standards, will be forty (40) feet. The side setbacks will be thirty-five
(35) feet.
In addition to the development, the developer will construct a bridge to cross Taylor
Loop Creek, similar to the bridge upstream serving Tulley Cove.
The applicant provided responses and additional information to all
issues raised during staff's review of the application. To staff's knowledge
there are no outstanding issues. The applicant is requesting no variances
with the proposed PD-R rezoning.
Staff is supportive of the requested PD-R zoning to allow the 15-unit residential
development. Staff views the request as reasonable. The property is in an
area of mixed uses and zoning. The proposed development should prove to
be compatible with the surrounding uses and zoning. Staff believes the
proposed PD-R zoning will have no adverse impact on the general area and
should prove to be a good transition use between the more intense uses along
Cantrell Road and the single family uses to the north.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested PD-R zoning, subject to
compliance with the comments and conditions outlined in paragraphs D, E and
F, and the staff analysis, of the agenda staff report.
PLANNING COMMISSION ACTION: (JANUARY 12, 2023)
The applicant was present. There were no persons present registered in opposition in
attendance. Staff informed the Commission that the applicant submitted a letter to staff
on January 11, 2023, requesting this application be deferred to the February 9, 2023
Planning Commission Agenda. Staff supported the deferral request. There was no
further discussion. The item remained on the consent agenda and was deferred as
recommended by staff. The vote was 10 ayes, 0 nays, 0 absent and 1 open position.
February 9, 2023
ITEM NO.: E (Cont.) FILE NO.: Z-9535-A
10
PLANNING COMMISSION ACTION: (FEBRUARY 9, 2023)
Staff informed the Commission that the applicant requested the application be withdrawn.
Staff supported the withdrawal request. The item was placed on the Consent Agenda for
withdrawal. The vote was 10 ayes, 0 nays and 1 absent. The application was withdrawn.
February 9, 2023
ITEM NO.: 1 FILE NO.: S-1914-A
NAME: Lots 1R, O. Jack Hartsell III, Inc. Subdivision – Replat
LOCATION: 7100 Beck Road
DEVELOPER:
O. Jack Hartsell, III
c/o Harrison Kemp
221 West 2nd Street, Suite 408
Little Rock, AR 72201
OWNER/AUTHORIZED AGENT:
O. Jack Hartsell, III – Owner
Ryan Kiernan – Owner
Harrison Kemp – Agent
SURVEYOR/ENGINEER:
E. S. Stan Cunningham, Jr.
2105 Lorance Drive
Little Rock, AR 72206
AREA: 0.42 acre NUMBER OF LOTS: 2 FT. NEW STREET: 0 LF
WARD: N/A PLANNING DISTRICT: 1 CENSUS TRACT: 42.05
CURRENT ZONING: R-2
VARIANCE/WAIVERS: None requested.
BACKGROUND:
On February 25, 2021 a lot split was recorded, splitting 3.75 acres at the northwest corner
of Beck Road and County Farm Road into two (2) lots (Lots 1R and 2R, O. Jack Hartsell
III, Inc. Subdivision). The lot split was approved by The City’s Planning Department and
the Pulaski County Planning Department. On August 18, 2022, the property owner, O.
Jack Hartsell III, sold the north 88 feet of Lot 1R to Ryan Kiernan, creating a lot split for
Lot 1R. The second lot split was not reviewed nor approved by the City or the County.
February 9, 2023
ITEM NO.: 1 (Cont.) FILE NO.: S-1914-A
2
Based on the fact that a third lot was created (from the original 3.75 acre property), the
second replat issue needs to be approved by the Planning Commission.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant proposes to replat Lot 1R, O. Jack Hartsell III, Inc. subdivision by
splitting the lot into two (2) lots.
B. EXISTING CONDITIONS:
The proposed Lot 1RA contains a two-story single family residence (7100 Beck
Road). The proposed Lot 1RB is undeveloped. Foundation work for a new single
family residence has begun on Lot 1RB.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property abutting the site and all neighborhood associations
registered with the City of Little Rock were notified of the public hearing.
D. ENGINEERING COMMENTS:
1. No comments.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments received.
Entergy: No comments received.
Summit Utilities: No objection to replat.
AT & T: No comments received.
Central Arkansas Water: NO OBJECTIONS; All Central Arkansas Water
requirements in effect at the time of request for water service must be met.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
February 9, 2023
ITEM NO.: 1 (Cont.) FILE NO.: S-1914-A
3
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
One- or Two-Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code
Vol. 1, One- or Two-Family dwelling residential developments. Developments
of one- or two-family dwellings where the number of dwelling units exceeds 30
shall be provided with two separate and approved fire apparatus access roads,
and shall meet the requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling units on a single public or
private fire apparatus access road and al dwelling units are equipped
throughout with an approved automatic sprinkler system in
accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the
Arkansas Fire Code, access from two directions shall not be required.
2. The number of dwelling units on a single fire apparatus access road shall
not be increased unless fire apparatus access roads will connect with
future development, as determined by the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal’s Office
(Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram
501-918-3756 Number and Distribution of Fire Hydrants as per Table C10.
Parks and Recreation: No comments received.
February 9, 2023
ITEM NO.: 1 (Cont.) FILE NO.: S-1914-A
4
County Planning:
1. Provide a bill of assurance.
2. Provide Pulaski County certificate of Final Approval.
3. Property is too small to have its own septic system. Provide and show a utility
easement to the septic system this residence will connect to.
F. BUILDING CODES/LANDSCAPE:
Building Code: No comments received.
Landscape: No comments.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division: No comments.
H. ANALYSIS:
The applicant proposes to replat Lot 1R, O. Jack Hartsell III, Inc. subdivision by
splitting the lot into two (2) lots. The existing Lot 1R was part of a previous staff-
level lot split, therefore, this second lot split must be reviewed and approved by the
Planning Commission. The applicant is proposing the two (2) lots as follows:
Lot 1RA – 11,438.78 square feet (0.26 acre)
Lot 1RB – 7,149.21 square feet (0.16 acre)
The proposed Lot 1RA contains a two-story single family home and was sold to
Ryan Kiernan on August 18, 2022 by O. Jack Hartsell, III. Mr. Hartsell retained
ownership of the proposed Lot 1RB. Mr. Hartsell recently began foundation work
for a new single family residence on Lot 1RB.
Section 36-254 (d) (4) of the City’s Zoning Ordinance requires a minimum lot width
of 50 feet, a minimum lot depth of 100 feet, and a minimum lot area of 6,000 square
feet. Both of the proposed lots conform with ordinance standards. No variances
are requested with the proposed replat.
Both Lots 1RA and 1RB will be serviced by separate septic sewer systems. Both
lots had successful percolation tests and both lots have been permitted by the
Department of Health for the installation of septic tanks and field lines. The
Department’s documentation was provided to staff by the applicant. A septic
February 9, 2023
ITEM NO.: 1 (Cont.) FILE NO.: S-1914-A
5
system easement is proposed on the rear portion of Lot 1RB for part of the field
lines for the septic system on Lot 1RA. The septic system for the proposed house
on Lot 1RB will be located in the front yard area.
Staff is supportive of the requested replat/lot split. Staff views the request as
reasonable. Both of the proposed lots conform with ordinance standards and the
applicant is requesting no variances. The proposed replat/lot split should have no
adverse impact on the surrounding properties.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested replat, subject to the comments and
conditions in paragraph E, and the staff analysis, of the agenda staff report.
PLANNING COMMISSION ACTION: (FEBRUARY 9, 2023)
Harrison Kemp was present representing the applicant. There were four (4) objectors
present. Staff presented the application with a recommendation of approval.
Matt Enderlin addressed the commission stating that he was opposed to the replat of a
900 square foot house and opposed any small houses in the area.
Bob Woolsey addressed the commission stating that he was opposed to the small tract
and construction of a “tiny” house in the area which would harm the neighborhood.
Travis Moore addressed the commission stating that he was opposed and that a small lot
and house were too small for the area.
Kendall Jones addressed the commission stating that a partition has been circulated in
the area in opposition to the proposed replat and tiny house. She also stated that this
type of subdivision of the land will set a negative precedent in the area.
Harrison Kemp addressed the commission representing the applicant stating that the
application is for a replat of the lots and not for a small house and that the lots as proposed
meets the ordinance standards.
There was a discussion by the Planning Commission regarding the size of the lot, septic
system approval by the state, any regulations regarding a house on the property and
conformity of the replat in relation to the governing ordinance. There was a motion to
approve the application, including all staff comments and conditions. The motion passed
by a vote of 8 ayes, 1 nay, and 2 recuse. The application was approved.
February 9, 2023
ITEM NO.: 2 FILE NO.: Z-9751
NAME: Masterminds Real Estate, LLC – Duplex – Conditional Use Permit
LOCATION: 1914 Dennison Street
DEVELOPER:
Gerald Little
Masterminds Real Estate, LLC
5217 District View Drive
Fort Worth, TX 76123
OWNER/AUTHORIZED AGENT:
Gerald Little (Owner)
Masterminds Real Estate, LLC
5217 District View Drive
Fort Worth, TX 76123
SURVEYOR/ENGINEER:
Ed Lofton
15414 Oakcrest Lane
Little Rock, AR 72206
AREA: 0.16 acre NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF
WARD: 1 PLANNING DISTRICT: 8 CENSUS TRACT: 11
CURRENT ZONING: R-3
VARIANCE/WAIVERS: None requested.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant is requesting a conditional use permit to allow construction of a
duplex on R-3 zoned property.
February 9, 2023
ITEM NO.: 2 (Cont.) FILE NO.: Z-9751
2
B. EXISTING CONDITIONS:
The property is located in an area of mixed zoning and uses, including R-4, R-5,
O-3, C-3 and I-2/I-3 zonings. A large area of R-4 zoning is located two (2) blocks
to the east.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 200 feet of the site and all neighborhood
associations registered with the City of Little Rock were notified of the public
hearing.
D. ENGINEERING COMMENTS: No comments.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments received.
Entergy: No comments received.
Summit Utilities: No comments.
AT & T: No comments received.
Central Arkansas Water:
1. NO OBJECTIONS; All Central Arkansas Water requirements in effect at the
time of request for water service must be met.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
February 9, 2023
ITEM NO.: 2 (Cont.) FILE NO.: Z-9751
3
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
One- or Two-Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code
Vol. 1, One- or Two-Family dwelling residential developments. Developments
of one- or two-family dwellings where the number of dwelling units exceeds 30
shall be provided with two separate and approved fire apparatus access roads,
and shall meet the requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling units on a single public or
private fire apparatus access road and al dwelling units are equipped
throughout with an approved automatic sprinkler system in
accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the
Arkansas Fire Code, access from two directions shall not be required.
2. The number of dwelling units on a single fire apparatus access road shall
not be increased unless fire apparatus access roads will connect with
future development, as determined by the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal’s Office
(Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram
501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comments received.
County Planning: No comments.
F. BUILDING CODES/LANDSCAPE:
Building Codes: No comments received.
February 9, 2023
ITEM NO.: 2 (Cont.) FILE NO.: Z-9751
4
Landscape: No comments.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division: No comments.
H. ANALYSIS:
The applicant is requesting a conditional use permit to allow construction of a
duplex on R-3 zoned property. The property is located in an area of mixed zoning
and uses, including R-4, R-5, O-3, C-3 and I-2/I-3 zonings. A large area of R-4
zoning is located two (2) blocks to the east.
The site plan indicates a lot width of 50 feet and a lot depth of 140 feet (7,000
square feet in area). The applicant proposes to build a two-story, 2,420 square
foot duplex with each unit measuring 1,210 square feet in area. The applicant will
not reside at the property and intends to rent/lease both units.
The site plan shows a front building setback of forty (40) feet. All remaining
building setbacks comply with ordinance requirements for structures in the R-3
Zoning District.
The applicant notes the building height will not exceed thirty-five (35) feet.
The applicant proposes to develop a driveway containing four (4) parking spaces,
extending from Dennison Street. Section 36-502 of the City’s Zoning Ordinance
requires a minimum of three (3) parking spaces for a duplex use. The proposed
parking complies with the ordinance requirement.
No signage is proposed at this time. Any future signage must comply with Section
36-551 of the City’s Zoning Ordinance (signs permitted in residential one – and
two – family zones).
To Staff’s knowledge, there are no outstanding issues associated with this
application. The applicant is requesting no variances with this request. Staff
believes the proposed duplex structure is an appropriate use for this property. The
duplex will not be out of character and represents only a minor increase in density.
Most properties south of I-630 looking south to W 30th Street and west from S Park
Street looking east to S State Street contain R-4, R-6 and PDR zoning and uses.
West of the site contain additional R-3 and I-2 zoning and uses. Staff feels the
proposed duplex will have no adverse impact on the subdivision or
surrounding uses.
February 9, 2023
ITEM NO.: 2 (Cont.) FILE NO.: Z-9751
5
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested conditional use permit, subject to
compliance with the comments and conditions outlined in paragraph E, and the
staff analysis, of the agenda staff report.
PLANNING COMMISSION ACTION: (FEBRUARY 9, 2023)
The applicant was present. There were no persons present registered in opposition. Staff
presented the item and a recommendation of approval as outlined in the “staff
recommendation” above. There was no further discussion. The item remained on the
consent agenda for approval as recommended by staff, including all staff comments and
conditions. The vote was 10 ayes, 0 nays and 1 absent.
February 9, 2023
ITEM NO.: 3 FILE NO.: Z-9755
NAME: HCS Inc. Duplexes – Conditional Use Permit
LOCATION: Northwest corner of West 46th Street and Foster Street
DEVELOPER:
HCS Inc.
PO Box 46074
Little Rock, AR 72214
OWNER/AUTHORIZED AGENT:
HCS Inc – (Owner)
Jess Griffin – Griffin Engineering (Agent)
11719 Hinson Road, Suite 130E
Little Rock, AR 72212
SURVEYOR/ENGINEER:
Jess Griffin – Griffin Engineering
11719 Hinson Road, Suite 130E
Little Rock, AR 72212
AREA: 1.64-acre NUMBER OF LOTS: 9 FT. NEW STREET: 0 LF
WARD: 6 PLANNING DISTRICT: 11 CENSUS TRACT: 24.05
CURRENT ZONING: R-3
VARIANCE/WAIVERS: None requested.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant is requesting a conditional use permit to allow for the
construction of nine (9) duplex structures on nine (9) lots (one (1) per
lot) at 4524 Foster Street, Lots 10 through 18, Block 13, Euclid Place
Addition.
B. EXISTING CONDITIONS:
The property is located within a residential neighborhood which contains mostly
single-family dwellings and some commercial structures. The site is currently
February 9, 2023
ITEM NO.: 3 (Cont.) FILE NO.: Z-9755
2
developed containing a dwelling with a garage out building and perimeter fencing.
The site is mostly open with large lawn areas to the south and east adjacent to the
dwelling.
C. NEIGHBORHOOD NOTIFICATION:
All owners of property located within 200 feet of the site and all neighborhood
associations registered with the City of Little Rock were notified of the public
hearing.
D. ENGINEERING COMMENTS:
1. Contact Planning and Development Dept., Engineering Division at
501-371-4817 or at 501-918-5348 for inspections of any work in the public
right-of-way prior to placement of concrete or asphalt or for on-site clarification
of requirements prior to commencing work. Failure to do so can result in
removal of any improperly placed concrete or asphalt at the expense of the
owner or contractor.
2. Any work involving one (1) or more acres of disturbed area requires a State
of Arkansas NPDES permit. Contact the Arkansas Department of
Environmental Quality, NPDES branch at 501-682-0744 for applications and
information about General Stormwater Discharge Construction Permit
#ARR150000.
3. Boundary street improvements are required per master street plan for a local
street along West 46th Street and Weldon Avenue. Boundary street
improvements shall include, but not be limited to, reconstruction of one-half
section of the abutting street if the existing street is not up to city standards.
Repair, replace, or extend existing damaged, missing, and noncompliant curb
and gutter, sidewalk, access ramps or concrete driveway aprons within the
public right-of-way adjacent to the site. Remove abandoned driveway cuts
and replace with curb, gutter, and sidewalk. All work within the public right-of-
way shall conform to City of Little Rock Public Works Standard Details and
ADA guidelines.
4. Additional right of way shall be dedicated to the City of Little Rock per master
street plan for a local street along West 46th Street and Weldon Avenue for
half-street improvements. Total right of way required from centerline of street
is 25 feet.
5. Damage to public and private property due to hauling operations or operations
of construction related equipment from a construction site shall be repaired
by the responsible party prior to the issuance of a certificate of occupancy.
6. Obtain Traffic Control (barricade) permits prior to doing any work on city
streets or in the right-of-way. Contact Traffic Engineering at 501-379-1800 for
more information.
February 9, 2023
ITEM NO.: 3 (Cont.) FILE NO.: Z-9755
3
7. A grading permit might be required prior to initiation of work. Grading permits
are issued by the Planning and Development Dept. at 723 West Markham
Street after approval of sediment and erosion control plans, grading and
drainage plans, land survey, drainage study, and soil loss calculations per
City’s stormwater management and drainage manual. Contact Planning and
Development Dept., Engineering Division at 501-371-4817 or at
501-918-5348 or Permits@littlerock.gov to schedule an appointment for
issuance or to answer any questions. Permit cost is based on total project
area at $100.00 for the less than ½ acre, $200.00 for ½ to 1 acre, and $200.00
for the first acre and $100.00 for each additional acre for project greater than
1 acre.
8. The Department requires three (3) phase sediment and erosion control (SEC)
plans to be submitted for all construction projects showing best management
practices (BMPs) for mitigating sediment runoff and erosion along with
vegetation specifications for temporary and permanent soil stabilization.
Phase 1 SEC plans shall show SEC BMPs during the stripping, clearing,
grubbing, and rough grading of the site. Phase 2 SEC plans shall show SEC
BMPs during construction of utilities, buildings, roadway infrastructure and
drainage infrastructure. Phase 3 SEC Plans shall show SEC BMPs for final
grading, seeding, and landscaping of the site.
9. Sediment and Erosion Control plans shall also show the pertinent information
as outlined in ADEQ ARR150000 Permit Part II section A-4-H (1-14) and Part
II section A- 4-I-2 (A-B).
10. A drainage study showing all hydrologic calculations for the site and all
hydraulic calculations for the proposed storm sewer pipe system, swales and
ditches, detention ponds, outlet structures, and inlets is required per City’s
stormwater management and drainage manual. For final drainage report,
sign, date, and seal the report per AR State Board of Professional Engineers
and Professional Surveyors rules Article 12, Section B (1) (a). Provide
engineer's certification statement saying this drainage report was conducted
by yourself or directly under your supervision and attesting to the accuracy of
the information within this report.
11. Per City Code 31-434, a 50% maintenance bond for all street and stormwater
infrastructure shall be submitted to Department engineering staff prior to
recording of the final plat. Before the 50% maintenance bond can be
accepted, a contract unit bid price for every street and stormwater
infrastructure construction item within the public right of way shall be
submitted to Department engineering staff for review and approval.
12. Per City Code 31-117, as built stormwater drainage infrastructure
information/data shall be submitted to the Department of Planning and
Development Engineering Division prior to recording of the final plat. This
information shall include but not limited to pipe inverts, length of pipe, size of
pipe, type of pipe, and type of inlets.
February 9, 2023
ITEM NO.: 3 (Cont.) FILE NO.: Z-9755
4
13. Per City Code 31-206 (f), “Property line corners at street intersections shall be
rounded with a radius of at least twenty (20) feet.”
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments received.
Entergy: No comments received.
Summit Energy: No comments received.
AT & T: No comments received.
Central Arkansas Water:
All Central Arkansas Water requirements in effect at the time of request for water
service must be met. The Little Rock Fire Department needs to evaluate this site
to determine whether additional public and/or private fire hydrant(s) will be
required. If additional fire hydrant(s) are required, they will be installed at the
Developer's expense.
14. If a fire hydrant is required on Weldon Ave or if fire sprinklers are
required in the duplexes a water main extension will be required
on Weldon Ave. They will be installed at the Developer's expense.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
February 9, 2023
ITEM NO.: 3 (Cont.) FILE NO.: Z-9755
5
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
One- or Two-Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code
Vol. 1, One- or Two-Family dwelling residential developments. Developments
of one- or t wo-family dwellings where the number of dwelling units exceeds 30
shall be provided with two separate and approved fire apparatus access roads,
and shall meet the requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling units on a single public or
private fire apparatus access road and al dwelling units are equipped
throughout with an approved automatic sprinkler system in accordance
with Section 903.3.1.1,903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code,
access from two directions shall not be required.
The number of dwelling units on a single fire apparatus access road shall not be
increased unless fire apparatus access roads will connect with future development,
as determined by the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal’s Office (Capt.
Tony Rhodes 501-918- 3757, or Fire Marshal Derek N. Ingram 501-918-3756
Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comments received.
County Planning: No comments.
F. BUILDING CODES/LANDSCAPE:
Building Code: No comments Received.
Landscape: No Comment.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments.
February 9, 2023
ITEM NO.: 3 (Cont.) FILE NO.: Z-9755
6
Planning Division: No comments.
H. ANALYSIS:
The applicant is requesting a conditional use permit to allow for the construction of
nine (9) duplex structures on nine (9) lots (one (1) per lot) at 4524 Foster Street,
Lots 10 through 18, Block 13 Euclid Place.
The property is located within a residential neighborhood which contains mostly
single-family dwellings and some commercial structures. The site is currently
developed containing a dwelling with a garage out building and perimeter fencing.
The site is mostly open with large lawn areas to the south and east adjacent to the
dwelling.
The applicant proposes to develop the 1.64 acre “L” shaped area which is bordered
to the east by Foster Street, to the south by West 46th Street, and west by Weldon
Street with a single-family lot to the north. The site plan show a single 2,348 square
foot duplex structure on each platted lot at two (2) stories in height.
The duplex structures will be located 25 feet back from the front property lines,
5 feet from the side property lines and 25 feet back from the rear property lines. All
proposed setbacks will conform with Section 36- 255 (R-3 zoning standards) of the
City’s Zoning Ordinance. The building heights are not to exceed 35 feet.
The applicant is proposing that each unit have a single car garage centered in the
front of the structure with paved access drives connecting to the adjacent Weldon
and Foster streets. The garage space within the duplex and proposed paved
driveways will provide parking for two (2) vehicles per unit. Section 36-502 requires
a minimum of three (3) parking spaces for each duplex. The parking as proposed
will be sufficient to serve the development.
No new fencing is proposed for the development.
No dumpster is proposed for the site and trash will be collected using standard City
of Little Rock garbage collection.
There is no signage proposed for the development.
Any site lighting must be low-level and directed away from the adjacent properties.
To staff’s knowledge, there are no outstanding issues associated with this
application. The property is designated as “RL” Residential Low Density per the
City’s Future Land Use Plan. Staff believes the proposed duplex structures located
at 4525 Foster Street are appropriate uses for this property and not be out of
character with the general area.
February 9, 2023
ITEM NO.: 3 (Cont.) FILE NO.: Z-9755
7
Staff is supportive of the requested conditional use permit to allow the duplex
development with the following boundary street improvements to be included:
1. Construction of one-half street improvements for each abutting street if the
existing street, is not up to city standards.
2. Repair, replace, or extend existing damaged, missing, and noncompliant curb
and gutter, sidewalk, access ramps or concrete driveway aprons within the
public right-of-way adjacent to the site.
3. Remove abandoned driveway cuts and replace with curb, gutter, and sidewalk.
All work within the public right-of-way shall conform to City of Little Rock Public
Works Standard Details and ADA guidelines.
4. Additional right of way shall be dedicated to the City of Little Rock per the
Master. Street plan for a local street along West 46th Street and Weldon
Avenue for half-street improvements. Total right of way required from
centerline of street is 25 feet.
Staff believes the proposed duplexes will have no adverse impact on the
residentially zoned properties or other surrounding uses. The applicant is
requesting no variances with the proposed development.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested CUP, subject to compliance with the
comments and conditions outlined in paragraphs D, and E, and the staff analysis,
in the agenda staff report.
PLANNING COMMISSION ACTION: (FEBRUARY 9, 2023)
Jesse Griffin was present, representing the application. There was eight (8) objectors
present. Staff presented the application with a recommendation of approval.
Savannah Wilkerson, Reba Lewis, Jennifer Wilkerson, Donald Scott, Beulah Scott,
James Murray, Anthony Thompson, and Kim Scott addressed the Commission in
opposition to the application. They stated that the proposed nine (9) duplexes will
decrease property values, cause traffic issues, increase crime, and fill the area with
people who have no connection to the neighborhood which will impact the current
property owners quality of life.
Jesse Griffin addressed the Commission representing the application. He briefly
described the project, noting that the R-3 zoned property already contained the lots and
was bordered by single family homes and that the duplexes will contribute to the area’s
growth.
February 9, 2023
ITEM NO.: 3 (Cont.) FILE NO.: Z-9755
8
There was a discussion by the Planning Commission regarding the street improvements,
number of duplexes being proposed, and how the proposed density compared to the
City’s Future Land Use Plan for the area.
There was a motion to approve the application as recommended by staff, including all
staff comments and conditions. The motion failed by a vote of 0 ayes, and 11 nays. The
application was denied.
February 9, 2023
ITEM NO.: 4 FILE NO.: Z-7500-I
NAME: Hamilton Station – POD
LOCATION: 14524 Cantrell Road
DEVELOPER:
Pinnacle Valley Shoppes, LLC
John Rees
11719 Hinson Road, Suite 130
Little Rock, AR 72212
OWNER/AUTHORIZED AGENT:
Pinnacle Valley Shoppes, LLC - Owner
Jess Griffin - Agent
SURVEYOR/ENGINEER:
Jess Griffin, PE
11719 Hinson Road, Suite 130
Little Rock, AR 72212
AREA: 10.67 acres NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF
WARD: 4 PLANNING DISTRICT: 1 CENSUS TRACT: 42.05
CURRENT ZONING: PCD and R-2
VARIANCE/WAIVERS: None requested.
BACKGROUND:
On August 31, 2017, the Planning Commission denied a proposed rezoning of this
property titled The Hamilton Apartments Long-form PD-R, a proposed 250 unit multifamily
development. The applicant appealed the Planning Commission’s decision to the Board
of Directors, but that request was withdrawn by the applicant.
On June 8, 2020, the applicant filed a second rezoning request for The Hamilton
Apartments – PD-R. On September 24, 2020 the Planning Commission withdrew the
PD-R rezoning at the request of the applicant.
February 9, 2023
ITEM NO.: 4 (Cont.) FILE NO.: Z-7500-I
2
On February 10, 2022, the Planning Commission approved an application for the
Hamilton Station – PCD (Z-7500-H) to allow mix commercial uses and mini-warehouse
development. The application was denied by the Board of Directors on March 15, 2022.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant proposes rezone 10.67 acres from R-2/PCD to POD. The developer
will construct a forty-thousand (40,000) square foot commercial building on the
4.96 acres within the western portion of the overall property to contain O-3
permitted uses with office showroom/warehouse and office/warehouse.
B. EXISTING CONDITIONS:
The property is currently undeveloped and partially tree covered. Some site work
has taken place, with fill material being placed on the 5.71 acre portion of the
overall site to the east. North, east and west of the site contain R-2 zoning and
uses. South of the site contains a mixture of commercial uses and zoning with
frontage along Cantrell Road.
C. NEIGHBORHOOD COMMENTS:
All owners of property located within 200 feet of the site and all neighborhood
associations registered with the City of Little Rock were notified of the public
hearing.
D. ENGINEERING COMMENTS:
1. Provide finished floor elevations (FFE) for all buildings on plat, site plan, and
grading and drainage plans at least one foot above base flood elevation or
more per flood insurance study and FEMA FIRM panel.
2. At the completion of the filling activities and prior to issuance of the final
Certificate of Occupancy or final approval, a letter of map revision (LOMR)
application must be submitted and approved by FEMA.
3. Due to the proposed structure being located within the 100-year floodplain,
an elevation certificate of the finished floor elevation must be provided to the
Public Works Department at 701 West Markham Street prior to the issuance
of a certificate of occupancy. Contact Vince Floriani in Public Works at
501-371-4823 or VFloriani@littlerock.gov to schedule an appointment for
issuance or to answer any questions.
4. Any work involving one (1) or more acres of disturbed area requires a
State of Arkansas NPDES permit. Contact the Arkansas Department of
Environmental Quality, NPDES branch at 501-682-0744 for applications and
February 9, 2023
ITEM NO.: 4 (Cont.) FILE NO.: Z-7500-I
3
information about General Stormwater Discharge Construction Permit
#ARR150000.
5. For future development for phase two to the east of the site, a Special Flood
Hazard Development Permit is required to be obtained to prior to
beginning construction. The Special Flood Hazard Development Permit
application can be found a thttps://www.littlerock.gov/city-administration/city-
departments/public-works/. Special Flood Hazard Development Permits are
issued by the Public Works Department at 701 West Markham Street and no
fee collected for issuance. Contact Vince Floriani in Public Works at
501-371-4823 or VFloriani@littlerock.gov to schedule an appointment for
issuance or to answer any questions.
6. A grading permit must be obtained prior to initiation of work for future
development for phase two to the east of the site. Grading permits are issued
by the Planning and Development Dept. at 723 West Markham Street after
approval of sediment and erosion control plans, grading and drainage plans,
land survey, drainage study, and soil loss calculations per City’s stormwater
management and drainage manual. Contact Planning and Development
Dept., Engineering Division at 501-371-4817 or at 501-918-5348 or
Permits@littlerock.gov to schedule an appointment for issuance or to answer
any questions. Permit cost is based on total project area at $100.00 for the
less than ½ acre, $200.00 for ½ to 1 acre, and $200.00 for the first acre and
$100.00 for each additional acre for project greater than 1 acre.
7. Damage to public and private property due to hauling operations or
operations of construction related equipment from a construction site shall be
repaired by the responsible party prior to the issuance of a certificate of
occupancy.
8. A drainage study showing all hydrologic and hydraulic calculations for the
proposed storm sewer pipe system, detention ponds and structures, and
inlets is required. For final drainage report, sign, date, and seal the report per
AR State Board of Professional Engineers and Professional Surveyors rules
Article 12, Section B (1) (a). Provide engineer's certification statement saying
this drainage report was conducted by yourself or directly under your
supervision and attesting to the accuracy of the information within this report.
9. The Department requires three (3) phase sediment and erosion control (SEC)
plans to be submitted for all construction projects showing best management
practices (BMPs) for mitigating sediment runoff and erosion along with
vegetation specifications for temporary and permanent soil stabilization.
Phase 1 SEC plans shall show SEC BMPs during the stripping, clearing,
grubbing, and rough grading of the site. Phase 2 SEC plans shall show SEC
BMPs during construction of utilities, buildings, roadway infrastructure and
drainage infrastructure. Phase 3 SEC Plans shall show SEC BMPs for final
grading, seeding, and landscaping of the site.
February 9, 2023
ITEM NO.: 4 (Cont.) FILE NO.: Z-7500-I
4
10. Sediment and Erosion Control plans shall also show the pertinent information
as outlined in ADEQ ARR150000 Permit Part II section A-4-H (1-14) and Part
II section A-4-I-2 (A-B).
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments received.
CenterPoint Energy: No comments received.
Summit Utilities: No comments.
AT & T: No comments received.
Central Arkansas Water:
1. Grading of the eastern lot is denied. Resubmit plans addressing the
comments below for further consideration.
2. CAW has critical, large, raw water lines on this property that are used to
supply water to the treatment plant. Field locate the lines and indicate
location of the lines on the plan. Include water line easements on the plan.
Field verify depth of pipelines.
3. Indicate existing and proposed contours on the plan. Fill will not be allowed
in the easement. If cuts are required, maintain a minimum of 36-inches of fill
over the pipelines.
4. No structure or footing shall be located within the easement or within 15-ft of
the pipelines.
5. Owner to provide a geotechnical engineer to examine the site to study the
potential increased loads on the pipes due to fill, adjacent structures and
dynamic loads during and after construction, and provide recommendations
to minimize additional burden on the pipes that are acceptable to CAW.
6. Submit final site and grading plan to be reviewed for approval by CAW.
7. All construction work, including earthwork, shall be observed by CAW.
Contact CAW, Andrew Pownall, prior to any work in this area.
The following comments are for the lot on the western side of the property:
8. Please submit plans for water facilities and/or fire protection system to Central
Arkansas Water for review. Plan revisions may be required after additional
review. Contact Central Arkansas Water regarding procedures for installation
February 9, 2023
ITEM NO.: 4 (Cont.) FILE NO.: Z-7500-I
5
of water facilities and/or fire service. Approval of plans by the Arkansas
Department of Health Engineering Division and Little Rock Fire Department
is required.
9. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height.
Building or facilities exceeding 30 feet or three stories in height shall have at least
two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provide with two separate and approved fire apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square
feet that have a single approved fire apparatus access road when all
building are equipped throughout with approved automatic sprinkler
systems.
February 9, 2023
ITEM NO.: 4 (Cont.) FILE NO.: Z-7500-I
6
D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of the
maximum overall diagonal dimension of the lot or area to be served, measured in
a straight line between accesses.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal’s Office
(Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram
501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comments received.
County Planning: No comments.
F. BUILDING CODES/LANDSCAPE:
Building Code: No comments received.
Landscape:
1. Any new site development must comply with Chapter 15 of the City’s Landscape
Ordinance.
2. Any variance request from Chapter 15 of the City’s Landscape Ordinance will require
a variance application to the Little Rock City Beautiful Commission.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
The request is in the River Mountain Planning District.
The Land Use Plan shows Transition (T) and Residential Low Density (RL) for the
requested area. Transition provides for an orderly transition between residential
uses and other more intense uses. A Planned Zoning District is required unless
the application conforms to the Design Overlay standards. Uses that may be
considered are low-density multi-family residential and office uses if the proposals
are compatible with quality of life in nearby residential areas. The Residential Low
Density category provides for single family homes at densities not to exceed
6 dwelling units per acre. Such residential development is typically characterized
February 9, 2023
ITEM NO.: 4 (Cont.) FILE NO.: Z-7500-I
7
by conventional single-family homes but may also include patio or garden homes
and cluster homes, provided that the density remains less than 6 units per acre.
The application is to rezone from R-2, Single Family District to POD, Planned
Office Development.
Surrounding the application area, the Land Use Plan Map shows Residential Low
Density (RL) developed to the west and north. These areas are developed with
single-family houses. Partially developed Transition (T) area to the east. Mixed
Office Commercial (MOC), Commercial (C), Mixed Use (MX) areas with dine-in
and drive-thru restaurants, strip commercial and small offices to the south along
Cantrell Rd.
Master Street Plan:
Access will be taken from the south through an adjacent property.
Bicycle Plan:
The Master Bike Plan shows an existing Class 1 Path traversing the southwest
corner. Class I Bike Paths are designated for the sole use of bicycles that is
physically separated from vehicular lanes. This path provides access from Cantrell
Rd on the south to Waterside Dr on the north.
Historic Preservation Plan:
There are no historic structures or districts in the area.
H. ANALYSIS:
The applicant proposes rezone 10.67 acres from R-2/PCD to POD. The developer
will construct a forty-thousand (40,000) square foot commercial building on the
4.96 acres within the western portion of the overall property to contain O-3
permitted uses with office showroom/warehouse and office/warehouse.
During Phase I, the applicant is also requesting permission to regrade and clean
up the remaining 5.71 acre portion of the overall property to the east, shown as
Phase II on the site plan for future use. The applicant notes special permission
will be obtained from Central Arkansas Water (CAW) prior to any construction
activities conducted within utility easements.
The western 4.96 acre portion of the overall property is currently undeveloped and
tree covered. Some site work has taken place with fill material being placed on
the 5.71 acre area to the east. R-2 zoning and uses are contained north, east and
February 9, 2023
ITEM NO.: 4 (Cont.) FILE NO.: Z-7500-I
8
west of the site. South of the site contains a mixture of existing commercial
developments at 14524 through 14810 Cantrell Road. The property is not located
in the Highway 10 Design Overlay District.
The site plan indicates that an area of fifteen-thousand (15,000) square feet
(“Building Section A”) will contain only spaces for office use. The remaining
twenty-five (25,000) square feet, (“Building Section B”) will contain additional office
spaces’ including Office Showroom/Warehouse and Office Warehouse.
The proposed building height will be sixty-five (65) feet and be constructed of brick,
stone, glass and metal on the rear of the building. The site plan shows a setback
over one-hundred (100) feet from the north (rear) property line, over eighty (80)
feet from the south (front) property line, eighty-one (81) feet from the west property
line and over sixteen (16) feet from what will be Phase II of the development.
The applicant notes that the hours of operation will be from 7:00am to 8:30pm
daily.
The main entrance to the proposed development will be at the southwest corner
of the overall property, through the Pinnacle Creek Shopping Center property at
14810 Cantrell Road. In addition, the developer will construct an emergency
access to the west and bike path further to the west in the southwest corner of the
development. The applicant is proposing 113 parking spaces. Staff feels the
proposed parking is sufficient to serve this use.
The applicant notes that there will be a forty-one (41) foot enhanced undisturbed
buffer along the west property line. Low and mid-level evergreen plantings will be
required within this area to help screen this development from the single family
residences to the west. All other buffer and landscaped areas will conform with
ordinance requirements.
The applicant notes that there will be a retaining wall along the east side of the
proposed enhanced undisturbed buffer. The retaining wall will have an average
height of eight (8) feet. There will be an eight (8) foot high opaque fence on top of
the retaining wall. Evergreen plantings (Emerald Arborvitae) will be placed inside
the screening fence. The evergreen plantings will have a six (6) foot height at the
time of planting, with a height of approximately 15 to 20 feet in maturity. Staff
believes that this with the enhanced undisturbed buffer will provide adequate
screening for the residential properties to the west.
There will be a dumpster area located near the northwest corner of the developed
area. The applicant notes that the dumpster area will be screened as per
ordinance requirements.
February 9, 2023
ITEM NO.: 4 (Cont.) FILE NO.: Z-7500-I
9
Any site lighting must be low-level and directed away from adjacent properties.
All signage must conform with Section 36-553 of the City’s Zoning Ordinance
(sings allowed in office zones). Since the property has no direct street frontage,
wall signs will be allowed on the south and east sides of the multi-tenant office
building. A ground-mounted sign will be allowed at the entry drive at the southwest
corner of the development.
The applicant is proposing an access easement and bike path construction at the
southwest corner of the development. The bike path will be constructed as per
Master Street Plan requirements.
Floodway is located along the north and east property boundaries. Any portion of
the proposed development will be located at least 25 feet back from the floodway.
A stormwater detention area with easement will be located at the northwest corner
of the development.
The applicant previously submitted (previous application) a traffic study for the
proposed development to staff. The traffic study concluded the following:
“The traffic associated with the development of Hamilton Station has
minimal impact to the traffic operations at the intersection of Cantrell
Road and Taylor Loop Road.”
The Department of Planning and Development staff engineer agreed at that time
with the conclusions of the traffic study from the consultant.
Staff requested that the applicant submit an amended traffic study addressing the
current proposal. Staff cannot support the application prior to an amended traffic
study with a favorable review for the proposed Phase I development.
The applicant is requesting no variances with the proposed POD rezoning.
The eastern 5.71 acres of the overall property is shown as Phase II of the proposed
POD development. This portion of the site will need to be brought back to the
Planning Commission for approval when development is proposed.
Staff is generally supportive of the proposed POD development. The proposed
development is less intense than the previous PCD request. However, staff cannot
support the application until an amended traffic study is submitted and approved
by the staff engineer. The proposed office development, with office
showroom/warehouse and office warehouse, will be less intense than the previous
PCD proposal, and will serve as more of a transitional use between the heavy
commercial uses along Cantrell Road and the single-family residences to the north
and west.
February 9, 2023
ITEM NO.: 4 (Cont.) FILE NO.: Z-7500-I
10
I. STAFF RECOMMENDATION:
Staff recommends denial of the requested POD zoning, until an approved
amended traffic study is completed.
PLANNING COMMISSION ACTION: (FEBRUARY 9, 2023)
Jesse Griffin was present, representing the application. There was one (1) objector
present. Staff presented the application with a recommendation of denial. The applicant
deferred their time to the opposition for comments.
Kent Brunen addressed the Commission in opposition to the application. He stated that
represented the neighborhood association adjacent to the site and that the proposed
development as submitted has drainage issues, an inaccurate grading plan , and that the
required undisturbed buffers were not in the condition represented by the applicant. He
stated that multiple proposals have been presented to the commission for this property
and that the surrounding property owners concerns have yet to be addressed along with
the ongoing site issues.
Jesse Griffin addressed the Commission representing the application. He briefly
described the project, noting that the applicant had submitted several variations of uses
for the site and that the site was in transition regarding any grading or drainage. He stated
that the applicant will provide the buffers as required once a final plan or use has been
approved by the commission.
There was a discussion by the Planning Commission regarding the landscaping, site
access, grading, and if the requested traffic study had been submitted by the applicant
as requested by staff.
There was a motion to approve the application, including all staff comments and
conditions. The motion denied by a vote of 4 ayes, and 7 nays. The application was
denied.
February 9, 2023
ITEM NO.: 5 FILE NO.: Z-4156-C
NAME: GSBC – Hair Salon – PD-C
LOCATION: 5901 W 57th Street
DEVELOPER:
Greater Second Baptist Church, Incorporated (Owner)
5615 Geyer Springs Road
Little Rock, AR 72209
OWNER/AUTHORIZED AGENT:
Marvin Jarret (Agent)
Greater Second Baptist Church, Incorporated
5615 Geyer Springs Road
Little Rock, AR 72209
SURVEYOR/ENGINEER:
Harbor Environmental & Safety
5800 Evergreen Drive
Little Rock, AR 72205
AREA: 0.40 acre NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF
WARD: 2 PLANNING DISTRICT: 13 CENSUS TRACT: 20.01
CURRENT ZONING: R-2 (CUP)
VARIANCE/WAIVERS: None requested.
BACKGROUND:
On February 26, 2015, the Little Rock Planning Commission approved a conditional use
permit to allow the residential building on the R-2 zoned lot to be utilized as a food pantry,
church office, and meeting space and storage by Greater Second Baptist Church located
on the north east corner of W 57th Street.
February 9, 2023
ITEM NO.: 5 (Cont.) FILE NO.: Z-4156-C
2
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant is proposing to rezone the 0.40 acre site from R-2 (CUP) to PD-C to
allow a hair salon (barber/beauty) located at 5901 W 57th Street.
B. EXISTING CONDITIONS:
The property contains an existing one-story, 1,424 square foot single-family
residence. An existing driveway provides access along W 57th Street. Properties
east and south contain and R-2 zoning and uses. Properties to the west along
Geyer Springs Road contain R-2, O-1, O-2 and I-2 zoning. A large church complex
is located to the north across W 57th Street.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property within 200 feet of the site and all neighborhood associations
registered with the City of Little Rock were notified of the public hearing.
D. ENGINEERING COMMENTS:
1. Provide accessible parking stalls where parking is provided in accordance with
2012 Arkansas Fire Prevention Code Sections 3411 and 1106.
2. Provide accessible route from the accessible parking stalls’ aisles to existing
building’s accessible entrance in accordance with Section 402 & 502 of ICC
A117.1-2017 and 2012 Arkansas Fire Prevention Code Sections 1104.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments received.
Entergy: No comments received.
Summit Energy: No comments received.
AT & T: No comments received.
Central Arkansas Water: No comments.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
February 9, 2023
ITEM NO.: 5 (Cont.) FILE NO.: Z-4156-C
3
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height.
Building or facilities exceeding 30 feet or three stories in height shall have at least
two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provide with two separate and approved fire apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square
feet that have a single approved fire apparatus access road when all
building are equipped throughout with approved automatic sprinkler
systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of the
maximum overall diagonal dimension of the lot or area to be served, measured in
a straight line between accesses.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal’s Office
(Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram
501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comments received.
February 9, 2023
ITEM NO.: 5 (Cont.) FILE NO.: Z-4156-C
4
County Planning: No comments.
F. BUILDING CODES/LANDSCAPE:
Building Code: No comments received.
Landscape:
1. Any new site development must comply with the City’s minimal landscape and
buffer ordinance requirements.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
The request is in the 65th Street East Planning District.
The Future Land Use Plan Map shows Public/Institutional (PI) for the requested
area. This category includes public and quasi-public facilities that provide a variety
of services to the community such as schools, libraries, fire stations, churches,
utility substations, and hospitals. The application is to rezone from R-2, Single
Family District to PD-C, Planned Development-Commercial.
Surrounding the application area north of W 57th Street, the Land Use Plan shows
Public/Institutional (PI) and Residential Low Density (RL). A church and single-
family houses are located on this land. Residential Low Density (RL) to the east
and south of the application site. Single-family houses are on most of these tracts.
Across Geyer Springs Rd to the west are small areas of Office (O) and
Public/Institutional (PI). A church and a few businesses are on this land.
Commercial (C) is shown between Geyer Springs Road and University Avenue
and along the South University Avenue Corridor. This land is mostly developed
along University Avenue with some vacant land along Geyer Springs Road.
Master Street Plan:
On the north is W 57th St. a Local Street on the Master Street Plan.
Local public street which is abutted by non-residential or residential use which is
more intense than duplex or two-unit residential is considered a Commercial
Street. These streets have the same design standard as a Collector. Right-of-way
is 60’. Sidewalks are required on both sides. At the time of site development
dedication of additional ROW or improvements may be required.
February 9, 2023
ITEM NO.: 5 (Cont.) FILE NO.: Z-4156-C
5
Bicycle Plan:
There are no Bike Routes in the vicinity.
Historic Preservation Plan:
There are no historic districts in the area. There are several potentially contributing
homes to the north on Sunnydale Dr.
H. ANALYSIS:
The applicant proposes to rezone a 0.40 acre site from R-2 (CUP) to PD-C to allow
a hair salon (barber/beauty) on the property. The property contains an existing
one-story, 1,424 square foot single-family residence. An existing driveway
provides access along W 57th Street. Properties east and south contain and R-2
zoning and uses. Properties to the west along Geyer Springs Road contain R-2,
O-1, O-2 and I-2 zoning. A large church complex is located to the north across W
57th Street.
The church currently owns the property which was approved for Conditional Use
Permit in February 2015. The existing CUP allows a food pantry, church office, a
meeting space and storage uses operated by Greater Second Baptist Church
(GSBC). The applicant notes the hair salon will not be owned or operated by the
church. The hair salon will be independently owned and operated.
The hair salon will contain four (4) employees utilizing four (4) work stations. The
operating hours will be from 10:00am to 8:00pm, Tuesday through Saturday.
The applicant provided to staff an example the long-term parking agreement to be
provided to the future owner and operator of the hair salon along with a parking
plan for the facility. The proposed salon will utilize a small portion of the large
church parking lot located immediately to the west. The parking plan provides six
(6) dedicated spaces for the hair salon to be located along the west side of the
building adjacent to a handicap access ramp which enters the proposed hair salon.
Staff feels the parking provided is sufficient to serve this use. The church will
remain in compliance for required parking for the church use.
The applicant is proposing no additional signage at this time. Any future signage
must comply with Section 36-553 of the City’s Zoning Ordinance (Signs allowed in
office and institutional zones).
Any new site lighting must be low-level and directed away from adjacent
properties.
February 9, 2023
ITEM NO.: 5 (Cont.) FILE NO.: Z-4156-C
6
The applicant notes standard City trash collection will be provided weekly. No
dumpster is proposed at this time. Any new dumpster must comply with Section
36-523 of the City’s Zoning Ordinance.
Staff is supportive of the requested PD-C zoning. Staff feels that this is a good
location for a barber/beauty use to serve the community at large. There are
additional barber/beauty uses to the west along Geyer Springs Road and further
along Geyer Springs Road as it veers north of GSBC. Staff feels that the proposed
use should have no adverse impact on surrounding properties. Ample parking for
the church is provided along W 57th Street located on the east and west sides of
the church. Additional church parking is provided to the south of W 57th Street.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested PD-C zoning, subject to compliance
with the comments and conditions outlined in paragraphs D, E and F, and the staff
analysis, of the agenda staff report.
PLANNING COMMISSION ACTION: (FEBRUARY 9, 2023)
Marvin Jarrett was present, representing the application. There was one (1) objector
present. Staff presented the application with a recommendation of approval. The
applicant deferred their time to the opposition for comments.
Troy Laha addressed the Commission in opposition to the application. He stated that the
board he represented was opposed to the use and why a church was operating a salon.
Marvin Jarrett addressed the Commission representing the application. He briefly
described the project, noting that the church was not operating the salon and that the
owner of the salon business was attempting to purchase the property in the future.
There was a motion to approve the application as recommended by staff, including all
staff comments and conditions. The motion passed by a vote of 10 ayes, 0 nays, and
1 absent. The application was approved.
February 9, 2023
ITEM NO.: 6 FILE NO.: Z-5817-L
NAME: Cantrell West Retail Center – PCD
LOCATION: 15122 Cantrell Road
DEVELOPER:
Rees Commercial
11719 Hinson Road, Suite 130
Little Rock, AR 72212
OWNER/AUTHORIZED AGENT:
Jesse Griffin
Griffin Engineering
11719 Hinson Road, Suite 130E
Little Rock, AR 72212
(501) 690-3456
SURVEYOR/ENGINEER:
Jesse Griffin
Griffin Engineering
11719 Hinson Road, Suite 130E
Little Rock, AR 72212
(501) 690-3456
AREA: 3.803 acres NUMBER OF LOTS: 3 FT. NEW STREET: 0 LF
WARD: 4 PLANNING DISTRICT: 1 CENSUS TRACT: 42.05
CURRENT ZONING: PD-O/R-2
VARIANCE/WAIVERS:
1. Variance to allow two (2) ground-mounted, monument type signs.
2. Variance to allow more than 30% of land use buffers to be disturbed.
3. Variance to allow a retaining wall to be greater than 15’ feet in height without block
face and no terraces.
4. Variance to allow reduced driveway separation.
February 9, 2023
ITEM NO.: 6 (Cont.) FILE NO.: Z-5817-L
2
BACKGROUND:
On July 16, 2020, the Planning Commission voted to approve a request to rezone this
property from PD-O and R-2 to PCD, to allow the property to be subdivided into three (3)
lots with a restaurant development on each lot. The rezoning request was denied by the
Board of Directors. On December 9, 2021 the applicant submitted a revised site plan with
a request to rezone the property from R-2 to PD-O. On February 10, 2022 the Planning
Commission voted to approve the request to rezone the property from R-2 to PD-O with
conditions. The rezoning request was referred back to the Planning Commission by the
Board of Directors on May 17, 2022.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant proposes to rezone a 3.803-acre property from PD-O/R-2 to PCD
located at the Northeast corner of Cantrell Road and Rummel Road. The rezoning
is to allow for a future commercial retail development with a main retail structure,
and an auto service center structure.
B. EXISTING CONDITIONS:
The property is currently divided into three (3) tracts with a majority of the property
cleared and graded. Tract # 1 is a 0.58-acre R-2 zoned undeveloped tract which
is mostly wooded and is located on the west border of the site adjacent to Rummel
Road and north side of Cantrell Road. Tract # 2 is a PD-O zoned lot centrally
located on the north side of Cantrell Road with a gravel access drive. Tract # 3 is
located at the eastern edge of the overall site with a paved access connecting to
Cantrell Road to the south. The property is bordered to the east by commercially
zoned properties and mostly R-2 zoned properties to the north and west across
Rummel Road. To the south of the property across Cantrell Road is a mixture of
residential and commercial zoned properties.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 200 feet of the site and all neighborhood
associations registered with The City of Little Rock were notified of the public
hearing.
D. ENGINEERING COMMENTS:
1. Any work involving one (1) or more acres of disturbed area requires a State
of Arkansas NPDES permit. Contact the Arkansas Department of
Environmental Quality, NPDES branch at 501-682-0744 for applications and
information about General Stormwater Discharge Construction Permit
#ARR150000.
February 9, 2023
ITEM NO.: 6 (Cont.) FILE NO.: Z-5817-L
3
2. Damage to public and private property due to hauling operations or
operations of construction related equipment from a construction site shall be
repaired by the responsible party prior to the issuance of a certificate of
occupancy.
3. Whenever access to State Highways is needed for residential or commercial
purposes, an access driveway permit is required. These permits are issued
by the Permit officer for the District in which the driveway will be located.
Please contact ARDOT District 6 permit officer at 501-569-2266.
4. A special permit is issued for work on the Arkansas Department of
Transportation right of way that is not an access driveway. The permit is
issued by the Permit officer for the District in which the special permit is
requested. Please contact ARDOT District 6 permit officer at 501-569-2266.
5. The Department requires three (3) phase sediment and erosion control (SEC)
plans to be submitted for all construction projects showing best management
practices (BMPs) for mitigating sediment runoff and erosion along with
vegetation specifications for temporary and permanent soil stabilization.
Phase 1 SEC plans shall show SEC BMPs during the stripping, clearing,
grubbing, and rough grading of the site. Phase 2 SEC plans shall show SEC
BMPs during construction of utilities, buildings, roadway infrastructure and
drainage infrastructure. Phase 3 SEC Plans shall show SEC BMPs for final
grading, seeding, and landscaping of the site.
6. Sediment and Erosion Control plans shall also show the pertinent information
as outlined in ADEQ ARR150000 Permit Part II section A-4-H (1-14) and Part
II section A-4-I-2 (A-B).
7. Per City Rev. Code 29-99, stormwater detention for developments is
required. Provide stormwater detention infrastructure to satisfy this
requirement. Provide grading and drainage plans showing the location of
stormwater detention, collection, and conveyance facilities and site discharge
location.
8. A drainage study showing all hydrologic calculations for the site and all
hydraulic calculations for the proposed storm sewer pipe system, swales and
ditches, detention ponds, outlet structures, and inlets is required per City’s
stormwater management and drainage manual. For final drainage report,
sign, date, and seal the report per AR State Board of Professional Engineers
and Professional Surveyors rules Article 12, Section B (1) (a). Provide
engineer's certification statement saying this drainage report was conducted
by yourself or directly under your supervision and attesting to the accuracy of
the information within this report.
9. Per City Code 31-210 (e) (1) for arterial streets, a lot will require six hundred
twenty-five (625) feet of frontage for two (2) drives. If two driveways are still
desired for this site by the developer, a variance request will have to be filed
February 9, 2023
ITEM NO.: 6 (Cont.) FILE NO.: Z-5817-L
4
with the application for the planning commission’s consideration per City
Code 31-210 (j).
10. Per City Code 31-210 (e) (1) for arterial streets, driveway spacing shall be
three hundred (300) feet. Driveway spacing shall be centerline to centerline
or centerline to right of way of an intersecting collector street or street of
higher classification. Minimum spacing from the property line shall be one
hundred fifty (150) feet. Maximum driveway width is thirty-six (36) feet.
Revise driveways to meet above requirement accordingly.
11. “If proposed retaining walls shown on plans are equal to or above four feet
tall measured from the bottom of the footing or leveling layer or if there is
surcharge loading for a retaining wall less than four feet tall measured from
the bottom of the footing or leveling layer, the Department requires retaining
wall design plans by an Arkansas licensed professional engineer showing
plan, profile, and cross sectional views of the wall with special details, design
loading calculations clearly showing all required factors of safety are met or
exceed per state building codes. A separate building permit-accessory
structure will be required for the retaining walls along with inspections by
Department engineering staff during their construction.”
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments received.
Entergy: No comment received.
Summit Utilities: No comment.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
2. Provide a 15-ft utility easement along the Cantrell Rd and Rummel Rd road
frontages.
3. The Little Rock Fire Department needs to evaluate this site to determine
whether additional public and/or private fire hydrant(s) will be required. If
additional fire hydrant(s) are required, they will be installed at the Developer's
expense.
February 9, 2023
ITEM NO.: 6 (Cont.) FILE NO.: Z-5817-L
5
4. Please submit plans for water facilities and/or fire protection system to Central
Arkansas Water for review. Plan revisions may be required after additional
review.
5. Contact Central Arkansas Water regarding procedures for installation of water
facilities and/or fire service. Approval of plans by the Arkansas Department of
Health Engineering Division and Little Rock Fire Department is required.
6. If there are facilities that need to be adjusted and/or relocated, contact Central
Arkansas Water. That work would be done at the expense of the developer.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building
or facilities exceeding 30 feet or three stories in height shall have at least two
means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provide with two separate and approved fire apparatus access roads.
February 9, 2023
ITEM NO.: 6 (Cont.) FILE NO.: Z-5817-L
6
Exception: Projects having a gross building area of up to 124,000 square
feet that have a single approved fire apparatus access road when all
building are equipped throughout with approved automatic sprinkler
systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of the
maximum overall diagonal dimension of the lot or area to be served, measured in
a straight line between accesses.
30’ Tall Buildings - Maintain aerial fire apparatus access roads as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1
– D105.4
D105.1 Where Required. Where the vertical distance between the grade plane
and the highest roof surface exceed 30’, approved aerial fire apparatus access
roads shall be provided. For the purposes of this section the highest roof surfaces
shall be determined by measurement to the eave of a pitched roof, the intersection
of a roof to the exterior wall, or the top of the parapet walls, whichever is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26’, exclusive of shoulders, in the immediate vicinity of the
building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes meeting
this condition shall be located within a minimum of 15 feet and a maximum of 30
feet from the building, and shall be positioned parallel to one entire side of the
building. The side of the building on which the aerial fire apparatus access road is
positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located over
the aerial fire apparatus access road or between the aerial fire apparatus road and
the building. Other obstructions shall be permitted to be places with the approval
of the fire code official.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead
Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be
provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal’s Office
(Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram
501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1.
February 9, 2023
ITEM NO.: 6 (Cont.) FILE NO.: Z-5817-L
7
Parks and Recreation: No comments received.
County Planning: No comment.
F. BUILDING CODES/LANDSCAPE:
Building Code: No comments received.
Landscape: No comments received.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comment.
Planning Division:
The request is in the River Mountain Planning District and the Highway 10 Design
Overlay District.
The Land Use Plan shows Suburban Office (SO) for the requested area. The
suburban office category shall provide for low intensity development of office or
office parks in close proximity to lower density residential areas to assure
compatibility. A Planned Zoning District is required. The application is to rezone
from R-2, Single Family Residential to PCD, Planned Commercial Development.
Surrounding the application area north of Cantrell Rd, the Land Use Plan shows
developed and undeveloped Residential Low Density (RL) area to the north.
Mixed Use (MX) with restaurant, office, and banking; then Commercial (C) with
drive thru restaurant and strip commercial to the east. South of Cantrell Rd is
Park/Open Space PK/OS along Taylor Loop Creek, developed RL and Transition
(T) with offices and a school.
Master Street Plan:
To the south is Cantrell Rd and is a Principal Arterial on Master Street Plan. To the
west is Rummel Rd which is a Local Street.
Function of Principal Arterials is to serve through traffic and to connect major traffic
generators or activity centers within urbanized areas. Right of way of 110 feet is
required unless otherwise stated. Sidewalks are required on both sides. A Local
public street which is abutted by non-residential or residential use which is more
intense than duplex or two-unit residential is considered a Commercial Street.
These streets have the same design standard as a Collector. Right-of-way is 60’.
February 9, 2023
ITEM NO.: 6 (Cont.) FILE NO.: Z-5817-L
8
Sidewalks are required on both sides. At the time of site development dedication
of additional ROW or improvements may be required.
Bicycle Plan:
The Master Bike Plan shows a proposed Class 1 Path along Cantrell Rd. Class I
Bike Paths are designated for the sole use of bicycles that is physically separated
from vehicular lanes.
Historic Preservation Plan:
There are no historic structures or districts in the area.
H. ANALYSIS:
The applicant proposes to rezone a 3.803-acre property from PD-O/R-2 to PCD
located at the Northeast corner of Cantrell Road and Rummel Road. The rezoning
is to allow for a future commercial retail development with a main retail structure,
and an auto service center structure.
The property is currently divided into three (3) tracts with a majority of the property
cleared and graded. Tract # 1 is a 0.58-acre R-2 zoned undeveloped tract which
is mostly wooded and is located on the west border of the site adjacent to Rummel
Road and north side of Cantrell Road. Tract # 2 is a PD-O zoned lot centrally
located on the north side of Cantrell Road with a gravel access drive. Tract # 3 is
located at the eastern edge of the overall site with a paved access connecting to
Cantrell Road to the south. The property is bordered to the east by commercially
zoned properties and mostly R-2 zoned properties to the north and west across
Rummel Road. To the south of the development across Cantrell Road is a mixture
of residential and commercial zoned properties.
The applicant is proposing a 28,026 square foot commercial retail structure to be
located within the northern portion of the property with a 6,620 square foot auto
service center structure in the east central portion of the development. Paved
parking and internal access drives will be located along the front and sides of each
building. The site plan indicates that internal drives will circle internal parking areas
in the south and east portions of the development and accommodate a drive-thru
window at the west end of the retail center building.
The applicant is requesting the following uses for the shopping center building:
• All O-1, O-2, and O-3 permitted uses and conditional uses.
• All C-1 permitted uses and conditional uses except the following:
ss. Secondhand store, used furniture or rummage shop.
February 9, 2023
ITEM NO.: 6 (Cont.) FILE NO.: Z-5817-L
9
tt. Shoe repair.
yy. Tool and equipment rental (inside display only).
a. Amusement, commercial (inside).
c. Appliance repair.
e. Cabinet or woodwork shop.
j. Convenience food store with gas pumps.
o. Furniture repair store.
v. Service station.
w. Theater (not drive-in).
x. Upholstery shop, furniture.
• Other commercial uses to be included.
a. Beverage Shop
b. Swimming pool sales and supply
c. Bakery and Confectionary Shop
d. Savings and Loan
e. Dry cleaners
f. Pharmacy
g. Medical clinic
i. Cigar, Tobacco, and candy store
The applicant notes that the hours of operation for development will be 7:00 am to
10:00 pm Monday through Saturday and 10:00 am to 8:00 pm on Sunday.
The development includes a main parking area centrally located with 151 spaces
to serve the main building and 28 parking spaces to serve the auto service center
at the southeast corner. The applicant also proposes an additional parking space
along the northeast perimeter of the development for delivery truck parking. The
applicant is propsoing179 parking spaces for this development. Staff believes the
overall parking layout will be sufficient to support the proposed use.
The applicant is proposing two (2) access drives to the site; one (1) centrally
located at the south perimeter and one (1) located near the southeast corner of the
development connecting to Cantrell Road. Each of the access drives include one
(1) entry lane and two (2) exit turn lanes which connect Cantrell Road to the internal
drives. Each of the drives will have a width of 36 feet.
Section 31-210 (e) (1) of the City’s Subdivision Ordinance for arterial streets
requires 625 feet of frontage for two (2) drives. The applicant has requested a
variance from the regulations to allow two (2) access drives from an arterial street
with a lot frontage of less than six hundred-twenty-five (625) feet in length. The
existing lot frontage is approximately 490 feet.
Section 31-210 (e) (1) of the City’s Subdivision Ordinance for arterial streets,
driveway spacing shall be three hundred (300) feet. Driveway spacing shall be
February 9, 2023
ITEM NO.: 6 (Cont.) FILE NO.: Z-5817-L
10
centerline to centerline or centerline to right of way of an intersecting collector
street or street of higher classification. Minimum spacing from the property line
shall be one hundred fifty (150) feet. The applicant has requested a variance from
the regulations to allow the two (2) access drives from Cantrell Road to be
separated by approximately 270 feet and the eastern most driveway to be located
approximately 65 feet from the east side property line.
The applicant is proposing three (3) dumpster areas located near the northeast
and northwest corners to the development with space for approximately eight (8)
dumpsters . The dumpster areas must be screened as per Section 36-523 of the
City’s Zoning Ordinance. The site plan additionally shows an enclosed tire storage
area adjacent to the dumpsters along the northeast perimeter of the site.
Section 36-346 of the City’s Zoning Ordinance (Highway 10 DOD) allows a
ground-mounted commercial development sign with a maximum height of 10 feet
and a maximum area of 100 square feet. All ground-mounted signs must be of a
monument type design. The applicant is requesting a variance to allow two (2)
ground -mounted signs of this development. The signs must comply with the
height and area standard of the DOD and be monument type signs.
All site lighting proposed must be low level and directed away from adjacent
properties.
Section 29-190(d) “Grading and drainage plan requirements“ is as follows: “Cut
or fills shall be limited to ten (10) feet in height or to fifteen (15) feet if architectural
stone is included to protect the vertical face. A series of smaller cuts or fills with
terraces, preserving portions of natural vegetation and providing areas for planting,
shall be used in situations where more than ten (10) feet of cut or fill is needed.”
The applicant is requesting to construct retaining walls along the north and east
property lines. The retaining walls will vary in height to a maximum height of
approximately 20 feet. The applicant is proposing to utilize no architectural stone
and no terraces with the proposed walls (cut and fill) . The applicant is requesting
a variance from the provisions of Section 29-190.
The applicant notes that the land use buffers along the north and east perimeters
will be significantly reduced to accommodate site grading requirements. Section
36-521 requires that a minimum of 70 percent of land use buffers be undisturbed.
The applicant notes that more than 30 percent of the required buffers will be
disturbed and has requested a variance from the regulations to allow 100 % of the
land use buffer requirement along the north perimeter of the site to be disturbed.
Staff is not supportive of the overall proposed site development plan as submitted
due to the following issues.
February 9, 2023
ITEM NO.: 6 (Cont.) FILE NO.: Z-5817-L
11
Staff believes an emergency access drive should be provided from Rummel
Road.
No vehicular access is available along the north perimeter of the main retail
structure to allow for deliveries or emergency vehicle access.
Staff cannot support the drive-thru area design/circulation at the west end
of the retail building, due to the fact that a specific use is not known for this
section of the building.
The C-4 auto related use is too intense for the development.
Staff does not support the intended retaining wall height along the north
property line as proposed.
I. STAFF RECOMMENDATION:
Staff recommends denial of the requested PCD zoning.
PLANNING COMMISSION ACTION: (FEBRUARY 9, 2023)
Jesse Griffin was present, representing the application. There was three (3) objectors
present. Staff presented the application with a recommendation of denial.
Jesse Griffin addressed the commission and requested that the item be deferred to the
March 9,2023 planning commission hearing agenda.
There was a motion to approve the applicants request for deferral. The motion passed
by a vote of 9 ayes, 0 nays, 1 recuse and 1 absent. The deferral was approved.
February 9, 2023
ITEM NO.: 7
NAME: Appeal of the Department of Planning and Development Staff’s Authority
LOCATION: Lots 33R and 34R, Grandview Addition
(5120/5200 N. Grandview Street)
APPELLANT:
Paula Aultz
c/o H. Baker Kurrus
43 N. Sherrill Road
Little Rock, AR 72202
REQUEST:
H. Baker Kurrus on behalf of Ms. Paula Aultz is appealing the Department of Planning
and Development Staff authority in authorizing a recombination of two (2) previously
platted lots; Lots 33R and 34R, Grandview Addition (5120/5200 N. Grandview Street).
The appellant contends that “…the Planning Director’s actions were outside the
scope of his authority, and that the matter should be handled through the normal
application process.” Correspondence submitted by the appellant is attached for
Planning Commission review.
The definition of “subdivision” according to Section 31-2 of the City’s Subdivision
Ordinance is as follows:
“Subdivision means all divisions of a tract or parcel of land in one (1)
or more lots, building sites, or other divisions for the purpose,
whether immediate or future, for sale or building development, and
shall include all divisions of land involving the need for new access, a
new street or a change in existing streets; provided, however, that the
following shall not be included within this definition, nor be subject to
the subdivision rules and regulations of this municipality:
(1) The combination or recombination of previously platted lots
where the total number of lots is not increased and the resultant
lots are equal to or exceed the standards or ordinance of the
municipality;
(2) The division of land into parcels greater than five (5) acres provided
each newly created lot or parcel has minimum lot frontage on legal
and physical access;
February 9, 2023
ITEM NO.: 7 (Cont.)
2
(3) The public acquisition by purchase or dedication of parcels of land
for the widening or opening of streets or other public
improvements.”
The Department of Planning and Development staff will present additional
information regarding the authority of staff in subdivision matters at the public hearing.
PLANNING COMMISSION ACTION: (FEBRUARY 9, 2023)
H. Baker Kurrus was present, representing the appeal. Bill Spivey, Bill Childers, and Mark
Stodola were present opposing the appeal. Staff presented the appeal description.
City Attorney Shawn Overton and Director of Planning Jamie Collins addressed the
Commission outlining the purpose of the appeal and history of the city processes
mentioned in the appeal.
Bill Spivey, Bill Childers, and Mark Stodola addressed the commission opposing the
appeal and presenting a history of the property mentioned in the appeal.
H. Baker Kurrus, Norman Hodge and Paula Aultz addressed the commission representing
the appeal and presented information regarding the appeal.
Bill Spivey, and H. Baker Kurrus addressed the commission with final statements
regarding the appeal.
There was a motion that “The Planning Staff’s action to allow the creation of Lot 34R was
within the Staff’s purview.” The vote was 4 ayes, 1 nay, 2 absent and 4 recusals /
abstentions.
PLANNING COMMISSION VOTE RECORD
DATE: February 9, 2023 4:OOPM
Minutes
Consent Agenda
A,B,C,D,E,2
RegularAgenda
MEMBER
1
3
4
5
6
7
BETTON, HAROLD
✓
✓
R
•
✓
✓
✓
✓
BROWN, JIMMY
✓
✓
✓
•
•
✓
R
✓
HART, TODD
✓
✓
✓
•
•
✓
✓
•
HAYNES, MARLON D.
✓
✓
✓
•
✓
D
✓
✓
HODGE, KAT
✓
✓
✓
•
•
✓
✓
Ab
LATTURE, PAUL
✓
✓
✓
•
✓
✓
✓
`/
McDONALD, ALICIA
✓
✓
R
•
•
✓
D
Ab
THOMAS, DIANA M.
✓
✓
✓
•
•
✓
✓
D
VICKERS, MICHAEL
✓
✓
✓
•
✓
✓
✓
D
VOGEL, ROBBY
✓
✓
•
•
✓
✓
✓
R
WHITAKER, PAMELA
D
D
✓
•
•
✓
✓
Ab
MEMBER
Meeting Adjourned 8:44 PM
✓AYE • NAYE A ABSENT Ab ABSTAIN R RECUSE
February 9, 2023
There being no further business before the Commission, the meeting was adjourned
at 8:44 p.m.
Date
Chairman Secretary